Manual de instrucciones Smeg P23LINP

15 de páginas No relevante
Descargar

Pasar a la página of 15

Summary
  • Smeg P23LINP - page 1

    INSTALLATION & USER INSTRUCTIONS All instructions must be handed to the user for safekeeping. M ODELS COVERED BY THESE INSTRUCTIONS P 2 3 L I N E A R - P 2 3 L I N P 2 3 C L A S S I C - P 2 3 C L L 2 3 L I N E A R - L 2 3 L I N L 2 3 C L A S S I C - L 2 3 C L L 3 0 F A B - L 3 0 F A B SMEG S.p.A. 42016 Guastalla (RE) I TALY W A L L M O U N T E ...

  • Smeg P23LINP - page 2

    • This applia nce is a high efficienc y, flueless catalytic flame effect gas fire. It provide s radiant and convecte d warmth both effi- cientl y and safel y utilising the latest type catalyti c converter and burner technol ogy. • The appli ance does not require a flue system of any type as the catal ytic converter cleans the flue products to p ...

  • Smeg P23LINP - page 3

    Destination Country Cat Inlet Pressure (mbar) Max Energy Input (kW) Min Energy Input (kW) High Burner Pressure (±1.5 mbar) Low Burner Pressure (±0.75 mbar) G20 G25 Gross Net Gross Net Hot Cold Hot Cold AT, CH, CZ, HR, ES, FI, GB, GR, IE, IT, NO, SE, SK, TR I 2H 20 - 2.60 2.35 1.50 1.35 13.7 13.6 4.3 4.4 DE, PL I 2E 20 - 2.60 2.35 1.50 1.35 13.7 1 ...

  • Smeg P23LINP - page 4

    Th is ap pl i a nc e ma y be i ns ta l l e d in an y ro o m in th e ho me ex c e p t ba t h r oo ms . If the appli- ance is to be fitted in a bedroom then an electronic carbon monoxide detector com- plying with the current edition of BSEN 50291 must be installed in the same room as the appliance . For maximum safety it is recomme nded that such dev ...

  • Smeg P23LINP - page 5

    R emove the outer packaging, remove any instructions or fixing kits. Read ALL these i nstructions before continuing to unpack or install this appliance. Lift off the remaining packaging components and remove the contents of the box. Check that the compo- nents suppl ied corr elate with the compon ent chec klist . Please dispose of all the packagi n ...

  • Smeg P23LINP - page 6

    If the appliance is to be mounted on a dry lined wall or a timber framed construction wall then efforts should be made to fix in at least two positions vertically, into o ne of the wooden studs, or supporting wooden mem- bers of the wall using tw o of the fixing screws provid- ed. If this is not achievable then the wall should be strength- ened usi ...

  • Smeg P23LINP - page 7

    Classic models : The control knob is located on the lower right hand side of the outer case. It is marked as s hown in figure 7; L inear models : The control knob is located on the lower right hand side of the outer case. It is marked as shown in figure 8; F ab models : The control knob is located on the lower right hand side of the outer case. It ...

  • Smeg P23LINP - page 8

    Please note that the Linear and Classic models are supplied with a tinted glass facia assembly, which dif- f er in appearance when viewed from the front, simi- larly the Fab model is supplied with a metal facia, however the method of attachment to the appliance, f or all frame designs, is the same. All models : Remove the facia panel from any prote ...

  • Smeg P23LINP - page 9

    Al l m o d el s : Fi r st l y, re mo v e th e dec o ra t iv e frame/glass facia assembly as described in section 8.3. Remove the inner glass panel, and disconnect the gas connection inside appliance. The gas con- nections to the gas valve can now be released. Detach the burner front cover plate by removal of the four retaining screws (as shown in f ...

  • Smeg P23LINP - page 10

    It is recommended that the catalysts are inspected for signs of damage and dirt during routine servicing procedures. The expect- ed life of the catalysts is in excess of 11,000 hours (10 years of normal use). After this time the catalysts should be replaced. If there are any deposits of dirt or soot on the catalyst they should be cleaned with a sof ...

  • Smeg P23LINP - page 11

    Fire sparks but pilot does not light No gas to fire, check isolators are open. Pipe work blockage, clean out. Air not fully purged, re purge supply or wait longer. Spark earthing to metal work, reset gap correctly. B locked pilot, clean out internally. Pilot lights but then goes out Severe restriction in gas supply: clear obstruction. Faulty thermo ...

  • Smeg P23LINP - page 12

    • The installation and Servicing of this fire MUST only be carried out by a competent person in accordance with local Codes and/or Regulations, Building Regulations and the manufacturer's instructions.Failure to comply with the above could lead to prosecution and invalidate the appliance warranty. In the event of gas leakage from the applian ...

  • Smeg P23LINP - page 13

    Clearances to combustible materials Combustible materials are defined as wood, fabrics, or other materials likely to combust if exposed to flame. Generally, any mate- rial, which is likely to discolour, melt or misshape when exposed to moderate heat, should be considered as a combustible mate- r ial or surface. Clearance to the sides of the applian ...

  • Smeg P23LINP - page 14

    Classic models : The control knob is located on the lower right hand side of the outer case. It is marked as shown in figure 2; Linear models : The control knob is located on the l ower right hand side of the outer case. It is marked as shown in figure 3; Fab models : The control knob is located on the lower right hand side of the outer case. It is ...

  • Smeg P23LINP - page 15

    The appliance should be checked on an annual basis to ensure it is working safely and that there is no excessive build up of soot. The frequency of service will depend on usage, but MUST be carried out at least once annually. Servicing must be carried out b y a competent person. The Installation instructions carry full servicing details for the use ...

Fabricante Smeg Categoría Fireplace

Los documentos del dispositivo Smeg P23LINP que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Smeg
- manuales de instrucciones P23LINP
- hojas de producto Smeg
- folletos informativos
- o etiquetas energéticas Smeg P23LINP
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Smeg P23LINP.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Smeg P23LINP, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Smeg P23LINP. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Smeg P23LINP.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Smeg P23LINP, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Smeg P23LINP. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Smeg P23LINP.

El manual de instrucciones completo de Smeg debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Smeg P23LINP - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Smeg P23LINP, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Smeg P23LINP que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Smeg P23LINP - que deben facilitarnos los primeros pasos durante el uso de Smeg P23LINP
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Smeg P23LINP
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Smeg P23LINP en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Smeg P23LINP?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Smeg P23LINP, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Smeg P23LINP probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)