Manual de instrucciones Reliance Water Heaters HE50 76N Series 100

40 de páginas 3.81 mb
Descargar

Pasar a la página of 40

Summary
  • Reliance Water Heaters HE50 76N Series 100 - page 1

    1 Instruction Manual PRINTED 0810 317775-000 KEEP THIS MANUAL IN THE POCKET ON HEA TER FOR FUTURE REFERENCE WHENEVER MAINTENANCE ADJUSTMENT OR SERVICE IS REQUIRED. POWER VENTED GAS MODELS W/HOT SURF ACE IGNITION MODEL HE 50 76N SERIES 1 00 ALL TECHNICAL AND W ARRANTY QUESTIONS: SHOULD BE DIRECTED T O THE LOCAL DEALER FROM WHOM THE W A TER HEA TER W ...

  • Reliance Water Heaters HE50 76N Series 100 - page 2

    2 SAFE INST ALLA TION, USE AND SERVICE The proper installation, use and servicing of this water heater is extremely important to your safety and the safety of others. Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all saf ...

  • Reliance Water Heaters HE50 76N Series 100 - page 3

    3 GENERAL SAFETY INFORMA TION ...

  • Reliance Water Heaters HE50 76N Series 100 - page 4

    4 GENERAL SAFETY INFORMA TION at le as t 1 8" (4 5. 7 cm ) ab ov e the f loo r. This will reduce, but not eliminate, the ri sk ...

  • Reliance Water Heaters HE50 76N Series 100 - page 5

    5 Thank Y ou for purchasing this water heater . Properly installed and maintained, it should give you years of trouble free service. Abbreviations Found In This Instruction Manual: • CSA -CanadianStandards Association • ANSI- AmericanNationalStandardsInstitute • NFP A -NationalFireProtection ...

  • Reliance Water Heaters HE50 76N Series 100 - page 6

    6 INST ALLA TION REQUIREMENTS FOR THE COMMONWEAL TH OF MASSACHUSETTS COMMONWEAL TH OF MASSACHUSETTS For all side wall terminated, horizontally vented power vent, direct vent, and power direct vent gas fueled water heaters installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or o ...

  • Reliance Water Heaters HE50 76N Series 100 - page 7

    7 TYPICAL INST ALLA TION * CAUTION HARNESS HAS 120 VAC. IN OPERATION. ** See “PLANNING THE VENT SYSTEM”, “CONDENSA TE” and “BLOWER ASSEMBL Y INST ALLA TION” for more information. *** The side recirculation loop connections may not be used as the primary water inlet and outlet connections. For your convenience, plugs are installed in the ...

  • Reliance Water Heaters HE50 76N Series 100 - page 8

    8 TYPICAL INST ALLA TION CONDENSA TE HOSE AND DRAIN P AN FIGURE 1 (continued). ...

  • Reliance Water Heaters HE50 76N Series 100 - page 9

    9 TYPICAL INST ALLA TION MIXING V AL VES DA NGER Wa ter temperatur e over 125° F (52° C) c an cause severe burns instantl y resulting in severe injury or death. Children, the elderly and the physically or mentally disabled are at highest risk for scald injury . Fe el water be fo re ba t hing or showering . Te mperature limiting devices such as mi ...

  • Reliance Water Heaters HE50 76N Series 100 - page 10

    10 ROUGH-IN-DIMENSIONS Rough-In-Dimensions T op/SideInletandOutlet:3/4”NPT GasInlet:1/2”NPT Capacity and Gas and Electrical Characteristics Allmodels-MaximumSupplyPressure:14inchesW .C.(3.48kPa) MinimumSupplyPressureNaturalGas:5.0inchesW .C.(1.24kPa) MinimumPressure? ...

  • Reliance Water Heaters HE50 76N Series 100 - page 11

    11 F ACTS TO CONSIDER ABOUT THE LOCA TION Carefully choose an indoor location for the new water heater , because the placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance. This water heater is not for use in manufactured (mobile) homes or outdoor installation. Wh ...

  • Reliance Water Heaters HE50 76N Series 100 - page 12

    12 in an alcove or closet, the entire oor must be covered by the panel. Failuretoheedthiswarningmayresultinarehazard. Minimum clearances between water heater and combustible construction are 0 inch at the sides and rear , 5.5” (14.0 cm)? ...

  • Reliance Water Heaters HE50 76N Series 100 - page 13

    13 Such a condition often will result in a yellow , luminous burner flame, causing sooting of the combustion chamber , burners and flue tubes and creates a risk of asphyxiation. Do not install the water heater in a conned space unless an adequate supply of air for combustion and ventilation is brought in to ...

  • Reliance Water Heaters HE50 76N Series 100 - page 14

    14 Figure 7. The water heater shall have clearances of at least 1 inch (25 mm) from the sides and back and 6 inches (150 mm) from the front of the appliance. The opening shall directly communicate with the outdoors or shall communicate through a vertical or horizontal duct to the outdoors or spaces that fre ...

  • Reliance Water Heaters HE50 76N Series 100 - page 15

    15 Thi s water heat er shou ld not b e con nec ted to any he ating sys tems or co mpo nent(s )u sedwi thano n- pot abl ewaterhe atinga ppli anc e. Al l pipin g co mpo nents c onn ec ted to thi s unit fo r spac e heat ing app lic atio ns sho uld be s uita ble fo r use w ith po tabl e water . T oxic c hemi ca ls, suc h as th ose ...

  • Reliance Water Heaters HE50 76N Series 100 - page 16

    16 THERMAL EXP ANSION As water is heated,it expands (thermal expansion). In a closed system the volume of water will grow when it is heated. As the volume of water grows there will be a corresponding increase in water pressure due to thermal expansion. Thermal expansion can cause premature tank failure (leakag ...

  • Reliance Water Heaters HE50 76N Series 100 - page 17

    17 discharge opening must not be blocked or reduced in size under any circumstances. Excessive length, over 30 feet (9.14 m), or  use of more than four elbows can cause restriction and reduce the discharge capacity of the valve. No valve or other obstruction is to be placed between the T emperature-Pressure Relief V al ...

  • Reliance Water Heaters HE50 76N Series 100 - page 18

    18 A  gas line of sufcient size must be run tothe water heater . Consult thecurrentedition ofNationalFuel GasCode(ANSI Z223.1/NFP A  54) or the Natural Gas and Propane Installation Code (CAN/CSA  B149.1)andyourgassupplierconcer ...

  • Reliance Water Heaters HE50 76N Series 100 - page 19

    19 Never use t his wate r heater u nles s it is c omp letely f ull of wate r . T o prevent d amage to t he t ank, t he t ank m ust be ll ed w ith wate r . Wate r must  ow fr om the hot water fau cet b efore t urn ing “O N ” gas to t he water heater. T oll? ...

  • Reliance Water Heaters HE50 76N Series 100 - page 20

    20 TERMINA TION CLEARANCES SIDEW ALL POWER VENT V X VEN T TERMINAL AIR SUPPL Y INLE TA RE A WHERE TERMINAL IS NO T PERMITTED v v A G V FIXED CLOSED FIXED CLOSED OPERABLE OPERABLE V C B B B B F B V V A J V H M X X V V K B E D L POWER VENT (using room air for combustion) EXTERIOR CLEARANCES FOR SIDE WA LL VENT TERMINA TION FIGURE 15. V ent terminal c ...

  • Reliance Water Heaters HE50 76N Series 100 - page 21

    21 PLANNING THE VENT SYSTEM Plan the route of the vent system from the discharge of the blower to the planned location of the vent terminal. Refer to V AA instruction on page 26 while planning the vent system. 1. Layout total vent system to use a min im um of vent pipe and elbows. 2. Thiswater heateris capableofventing ? ...

  • Reliance Water Heaters HE50 76N Series 100 - page 22

    22 The condensate trap may be primed by lling the CONDENSA TE U-ASSEMBL Y with tap water while the water heater is not operating. The system is fully primed when the water level reaches the adaptor connected into the T ee. In most installations the water heater will self-prime thecondensate trap during? ...

  • Reliance Water Heaters HE50 76N Series 100 - page 23

    23 CAUTION LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERA TION. VERIFY PROPER OPERA TION AFTER SERVICING. POWER VENT WIRING SCHEMA TIC - FIGURE 19. may be easier to mark both the inside and outside wall. Align holes by drilling a hole through center of the template from the insid ...

  • Reliance Water Heaters HE50 76N Series 100 - page 24

    24 INST ALLA TION OF VENT SYSTEM, SIDEW ALL With the route of the venting system and selection of materials completed, as discussed in the section of this manual titled PLANNING THE VENT SYSTEM, the through the wallvent terminal in place and the rst section  of piping, up to rst elbow , ...

  • Reliance Water Heaters HE50 76N Series 100 - page 25

    25 VENT A TTENUA TI ON ASSEMBL Y I N ST ALL A T I O N I NSTRUC T I ON S The V ent Attenuation Assembly (V AA) is designed to provide a reduction in fan noise created in the blower wheel. This installation of this V AA is optional. Review directions thoroughly prior to installing the new V AA. Please contact the manufac ...

  • Reliance Water Heaters HE50 76N Series 100 - page 26

    26 bar b, use a wir e tie o r hose c lam p ( not sup plie d with k it)  and secure. 6. T ake th e other e nd of th e fl exible t ubing a nd sli de it thr ough the h ose c lamp o n the jac ket top c over and inst all i t into one of the f our bar b f it ting s in vent pip e asse mbly # 2. 7. Once installed? ...

  • Reliance Water Heaters HE50 76N Series 100 - page 27

    27 VENT PIPE PREP ARA TION 1. INITIAL PREP ARA TION A. Make sure the solvent cement you are planning to use is designedforthespecicapplicationyouareattempting. B. Know the physical and chemical characteristics and limitations of the PVC and CPVC piping materials that you are about to use. C. Know the reputation of your manuf ...

  • Reliance Water Heaters HE50 76N Series 100 - page 28

    28 B. Deburring  Usea knife, plasticpipe deburring tool,or le toremove burrs fromthe  end of small diameter pipe. Be sure to remove all burrs from around the inside as well as the outside of the pipe.  A slight chamfer (bevel) of about  10°-15° shou ...

  • Reliance Water Heaters HE50 76N Series 100 - page 29

    29 FOR YOUR SAFETY READ BEFORE OPERA TING W ARNING: If you do not follow these instructions exactly , a re or explosion may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner . Do NOT try to light the burner by hand ...

  • Reliance Water Heaters HE50 76N Series 100 - page 30

    30 It is recommended that lower water temperatures be used to avoid the risk of scalding. It is further recommended, in all cases, that the water temperaturebe set for thelowest temperature whichsatises your hot water needs. This will also provide the most energy efcient operat ...

  • Reliance Water Heaters HE50 76N Series 100 - page 31

    31 FOR YOUR INFORMA TION ST ART UP CONDITIONS SMOKE/ODOR It is not uncommon to experience a small amount of smoke and odor during the initial start-up. This is due to burning of f of oil from metal parts, and will disappear in a short while. STRANGE SOUNDS Possible noises due to expansion and contraction of some metal parts during periods of heat-u ...

  • Reliance Water Heaters HE50 76N Series 100 - page 32

    32 VENTING SYSTEM INSPECTION At least once a year a visual inspection should be made of the venting system. Y ou should look for: 1. Obstructions which could cause improper venting. The combustion andventilationairowmustnotbeobstructed. 2. Damage or deterioration which could cause improper venting or leakage of combustion pr ...

  • Reliance Water Heaters HE50 76N Series 100 - page 33

    33 The anode rod is used to protect the tank from corrosion. Most hot water tanksareequipped withan anoderod. Thesubmergedrodsacrices itself to protect the tank. Instead of corroding tank, water ions attack and eat away the anode rod. This does not affect water ’s taste or ...

  • Reliance Water Heaters HE50 76N Series 100 - page 34

    34 LEAKAGE CHECKPOINTS Neveruse thiswaterheater unlessit iscompletelylled withwater .  T o prevent damage to the tank, the tank must be lled with water .  W atermustowfromthe hotwaterfaucetbeforeturning“ON” gas to the wa ...

  • Reliance Water Heaters HE50 76N Series 100 - page 35

    35 TROUBLESHOOTING GUIDELINES TROUBLE SHOOTING Pleasecheckguidelinesbelow .Foryoursafety ,waterheaterserviceshouldbeperformedonlybyaqualiedservicetechnician. ReadtheGENERAL SAFETYINFORMA TIONsectionrst. INTELLI-VENT TROUBLESHOOTING CHART - USER CONTROL PROBLEM SO ...

  • Reliance Water Heaters HE50 76N Series 100 - page 36

    36 TROUBLESHOOTING GUIDELINES TROUBLE SHOOTING Pleasecheckguidelinesbelow .Foryoursafety ,waterheaterserviceshouldbeperformedonlybyaqualiedservicetechnician. ReadtheGENERAL SAFETYINFORMA TIONsectionrst. INTELLI-VENT TROUBLESHOOTING CHART - USER CONTROL PROBLE MS ...

  • Reliance Water Heaters HE50 76N Series 100 - page 37

    37 TROUBLESHOOTING GUIDELINES TROUBLE SHOOTING Pleasecheckguidelinesbelow .Foryoursafety ,waterheaterserviceshouldbeperformedonlybyaqualiedservicetechnician. ReadtheGENERAL SAFETYINFORMA TIONsectionrst. INTELLI-VENT TROUBLESHOOTING CHART - USER CONTROL PROBLE MS ...

  • Reliance Water Heaters HE50 76N Series 100 - page 38

    38 Theseguidelinesshouldbeutilizedbyaqualiedserviceagent. TROUBLESHOOTING GUIDELINES TROUBLESHOOTING GUIDELINES ...

  • Reliance Water Heaters HE50 76N Series 100 - page 39

    39 Limited W arranty Reliance, the warrantor , extends the following LIMITED WARRANTY to the owner of this water heater . 1. THE T ANK If the glass-lined tank in this water heater shall prove upon examination by the warrantor to have leaked due to natural corrosion from potable water therein, during the rst THREE years after in ...

  • Reliance Water Heaters HE50 76N Series 100 - page 40

    www .reliancewaterheaters.com 500 T ennessee W altz Parkway Ashland City , TN 37015 T echnical Support 800-365-4054 Parts 800-821-2017 ...

Fabricante Reliance Water Heaters Categoría Water Heater

Los documentos del dispositivo Reliance Water Heaters HE50 76N Series 100 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Reliance Water Heaters
- manuales de instrucciones HE50 76N Series 100
- hojas de producto Reliance Water Heaters
- folletos informativos
- o etiquetas energéticas Reliance Water Heaters HE50 76N Series 100
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Reliance Water Heaters HE50 76N Series 100.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Reliance Water Heaters HE50 76N Series 100, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Reliance Water Heaters HE50 76N Series 100. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Reliance Water Heaters HE50 76N Series 100.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Reliance Water Heaters HE50 76N Series 100, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Reliance Water Heaters HE50 76N Series 100. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Reliance Water Heaters HE50 76N Series 100.

El manual de instrucciones completo de Reliance Water Heaters debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Reliance Water Heaters HE50 76N Series 100 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Reliance Water Heaters HE50 76N Series 100, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Reliance Water Heaters HE50 76N Series 100 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Reliance Water Heaters HE50 76N Series 100 - que deben facilitarnos los primeros pasos durante el uso de Reliance Water Heaters HE50 76N Series 100
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Reliance Water Heaters HE50 76N Series 100
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Reliance Water Heaters HE50 76N Series 100 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Reliance Water Heaters HE50 76N Series 100?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Reliance Water Heaters HE50 76N Series 100, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Reliance Water Heaters HE50 76N Series 100 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)