Manual de instrucciones Furuno 1835

48 de páginas 3.83 mb
Descargar

Pasar a la página of 48

Summary
  • Furuno 1835 - page 1

    Installation Manual MARINE RADAR MODEL1835/1935/1945 SAFETY INSTRUCTIONS .... .......................................................................... .............................. .i SYSTEM CONFIGURATION ................................ .......................................... .............................. ii EQUIPMENT LISTS ................ ...

  • Furuno 1835 - page 2

    ...

  • Furuno 1835 - page 3

    i SAFETY INSTRUCTIONS WARNING Radio Frequency Radiation Hazard Do not open the equipment unless totally familiar with electrical circuits and service manual. Only qualified personnel should work inside the equipment. Wear a safety belt and hard hat when working on the antenna unit. Serious injury or death can result if someone falls from the radar ...

  • Furuno 1835 - page 4

    ii SYSTEM CONFIGURA TIONS 12 - 24 VDC Display unit RDP-152 100/1 10/220/230 V AC for M1835 External buzzer Echo sounder GPS navigator AIS, etc. Rectifier PR-62 Remote display : Basic configuration Heading sensor MODEL 1835 Antenna unit RSB-0071-057 Echo sounder GPS navigator AIS, etc. ECONOMY RANGE TLL GAIN TRAILS OFF CENTER TARGET ALARM STBY T X A ...

  • Furuno 1835 - page 5

    iii EQUIPMENT LISTS S t andard supply Note: The name for MODEL1835, MODEL1935, MO DEL1945 is shortened to M1835, M1935, M1945 in this manual. Name T ype Code No. Qty Comment Display unit RDP-152 - 1 Antenna unit RSB-0071-057 - 1 Unit for M1835 XN10A-RSB-0070-064 Unit for M1935, 24 RPM XN10A-RSB-0073-064 Unit for M1935, 48 RPM XN12A-RSB-0070-059 Uni ...

  • Furuno 1835 - page 6

    iv Optional supply Name T ype Code No. Qty Comment Rectifier PR-62 - 1 For M1835 RU-3423 - For M1935/1945 External buzzer OP03-21 000-030-097 1 Cable assy . MJ-B24LPF0010-100+R 000-147 -880-12 1 For remote display , 10 m MJ-B24LPF0010-200+R 000-147-881-1 2 1 For remote display , 20 m MJ-B24LPF0010-300+R 000-147-882-1 2 1 For remote display , 30 m M ...

  • Furuno 1835 - page 7

    1-1 1. HOW TO INST ALL THE SYSTEM 1.1 Displ ay U nit Select a l ocati on for t he disp lay unit by fo llowi ng the inf ormation s hown below. • The unit is waterproof, but FURUNO recommends that you inst al l th e display unit in a cabinet. • Keep the unit away from direc t sunlight. • The temperatur e and hu midity must meet t he requir emen ...

  • Furuno 1835 - page 8

    1-2 How to install the display unit in a console Follow the procedure sho wn below to install the display unit in a console. 1. Prepare a hole in the location whose dime nsions are 274 (W) x 252 (H) mm. 2. Make four pilot holes. See the outline drawing at the b ack of this manual for additional infor- mation. 3. Set a flush mount sponge supplied as ...

  • Furuno 1835 - page 9

    1-3 1.2 Antenna Unit for MODEL1835 How to select the location for the antenna unit When you select an installation location for th e antenna unit, remember the following points. • Install the antenna unit on a so lid location, for example radar arch or on a mast on a plat form. (For sailboats, a mounting bracket is optionally available.) Y ou mus ...

  • Furuno 1835 - page 10

    1-4 How to install the antenna unit 1. Open the packing box of the antenna unit with great caution. 2. Loosen the four bolts at the base of the radome to remove the radome cover . Antenna unit The location where you install the antenna unit must be p arallel to the waterline. Make five holes in the installation location . See the outline drawing at ...

  • Furuno 1835 - page 11

    1-5 How to fasten the radome base to the pl atform Wiring an d pre paration 4. Make a hole of at leas t 20 milli meters in diamet er t hrough the dec k or bulkhe ad to r un the sig- nal cable. (T o prev ent electri cal inte rf erence, do not run the signa l cable near other el ectrical equipment. Do not run the cable in p arall el to power cables. ...

  • Furuno 1835 - page 12

    1-6 Signal cable, the side of antenna uni t RF unit to one of the screws of the cable clamping plate 9-pin connector: to J801 on MD-9208 4-pin connector: to J802 on MD-9208 13-pin connector: to J611 on IF-9214 J802 J801 J611 MD-9208 IF-9214 PTU-9335 Cable entr y ...

  • Furuno 1835 - page 13

    1-7 10. Att ach the EMC core suppli ed as shown below . How to attach EMC core 1 1.Att ach t he shi eld cov ers. Make sure the cabl e is not caught by t he cover . 12.Att ach the ra dome cover . Ali gn the triangle mark on radome cover with that on r adome base. How to attach the radome cover 13.Fasten the r adome bolt s. J806 J805 J803 J804 J802 J ...

  • Furuno 1835 - page 14

    1-8 How to install the optional mounting bracket The optional mounti ng bracket le ts you fasten the antenna uni t to a mast on a sailboat. Mounting bra cket kit Typ e: OP 03- 92 Code No.: 008-445-070 Assemble the mounting brac ket and fasten the mountin g bracket to a mast. Fasten the antenna unit to the bracket . How to assembl e and i nstall the ...

  • Furuno 1835 - page 15

    1-9 1.3 Anten na U nit for MOD EL1935 /194 5 How to select th e location for th e ante nna unit • The antenna unit is inst alled eit her on top of the wheelhouse or a plat form on the radar mas t. Insta ll the antenna uni t where ther e is a good complete view . Any obst ruction c auses bli nd sec- tors. For ex ample, a mast with a di ameter smal ...

  • Furuno 1835 - page 16

    1-10 Installation pr ocedure Refer to the out line dr awin g at the back of this manual for t he dimens ions . Make fiv e hole s in the platform. Four ho les to f asten the antenna u nit a nd one hol e for the si gnal cabl e. How to fasten the rad iat or to the radiator brac ket See the packing list at the back of this manual for the ins tal l atio ...

  • Furuno 1835 - page 17

    1-11 How to install the antenna unit You can install the antenna uni t by one of the two metho ds shown below. • Use the outsi de holes • Use the inside holes How to use ou tside ho le s of the an te nn a ho using Use the hex head bolts (suppli ed) to install the antenna unit as shown in the illu strati on bel ow. 1. Put the rubber mat (s uppli ...

  • Furuno 1835 - page 18

    1-12 3. Set four hex head bolts (M12x60, supplied) and seal wa shers (supplied) from the top of the antenna housing, as shown below . How to set the antenna unit chassis 4. Set the flat washers (M12, supplied), spring wa shers (supplied) and nuts (supplied ) to the hex head bolts. T ighten by turning the nuts. Do not tighten by turning the hex head ...

  • Furuno 1835 - page 19

    1-13 8. Apply the s ilicone sealant t o the ground te rminal and ground p oint a s shown below . How to apply the s ilicone seal ant t o the ground point and ground t erminal How to use the inside holes of the antenna h ou sing This method requi res r emoval of t he RF unit from the antenna unit to acces s the ins ide fix ing holes. Use four hex h ...

  • Furuno 1835 - page 20

    1-14 Antenna unit chas sis, upper chassi s separated 7. Set the corrosio n-proof r ubber mat (suppl ied) to the support plat fo rm. 8. Cut the rubber bushings in the fixing holes and put four bolts fr om the inside of the lower chas- sis. Fasten the lower chassis t o the support plat form with t he spring washers, flat washers and nuts (l ocal supp ...

  • Furuno 1835 - page 21

    1-15 How to connect the signal cable The signal cable runs from the display unit t o t he antenna unit. To red uce the electrical interfer- ence, do not run the signal cable near other electrical equipment. And do not run the cab le in par- allel to power cables. Put the cable through the hole and apply the sealing compound a round the hole for wat ...

  • Furuno 1835 - page 22

    1-16 5. Put the signal cable so that no more than 4 cm of the sheath is visible, as shown in the figure below . T ighten the fixing bolt s. How to fasten signal cable in ca ble gland 6. Loosen four screws in the figure shown below and op en the cover . Antenna unit chassis, cover opened 7. Put the signal cable through the cable p rotector . Antenna ...

  • Furuno 1835 - page 23

    1-17 8. Connect the signal cable to the R TB Board (03P9249). See the interconnec tion dia gram and the figur e shown be low . 9. Attach thr ee EMI cores to the signal cabl e as shown belo w . Antenna unit chassi s, cover opened 10.Fasten the s ignal cable with the cabl e clamp. 1 1.Undo th e st ay and close the cove r . Securely f ast en the scann ...

  • Furuno 1835 - page 24

    1-18 This page is intentionally blank. ...

  • Furuno 1835 - page 25

    2-1 2. CABLE CONNECTION 2.1 S t andard Connect ion Connect all cables at the rear o f the di splay unit. Display unit, r ear vi ew Antenna cable MJ-B24LPF0002-xxx+R or MJ-B24LPF0005-yyy+R CAUTION Ground terminal Connect ground wire between here and ship's ground. Ground the equipment to prevent interference. CAUTION NMEA1 NMEA2 HDG DJ-1 OPTION ...

  • Furuno 1835 - page 26

    2-2 2.2 Dat a Signal Port Connect external equipment(s) to th e por ts on the rear panel as shown below. The Model 1835/1935/194 5 can receive the following NMEA 0183 format senten ce from other equipment. • Position GNS>GGA>RMC> GLL • Course true VTG>RMC • Course magnetic VTG>RMC (true) • S p e e d o v e r g r o u n d V T G ...

  • Furuno 1835 - page 27

    3-1 3. HOW TO SET THE EQUIPMENT 3.1 How to Set the Langua ge At the first power appli catio n after instal l ation, select a language as follows. 1. Press /BRILL key t o turn on the power . "Now Initial izing" appears an d af ter a whi le the window bel ow appears . 2. Use the cursor pad to select a language requi red and pres s the ENT E ...

  • Furuno 1835 - page 28

    3-2 3.2 How to Set the Purpose Set the purpose of the radar. 1. Press t he MENU key. The main menu appears on the screen. 2. Press T or S on the cursor p ad to select F actory . The factory menu title bar appears in gray on the right of the screen. 3. While you press the CANCEL/HL OFF k ey , press the MENU key five times to activate the Factory men ...

  • Furuno 1835 - page 29

    3-3 3.3 How to Enter the Initial Settings After you set the purpose of the radar, enter the initial settings as follows. 1. On the main menu, press T or S to select Installation . 2. Press the ENTER key . The Installation menu becomes active and the cursor moves to the right column. 3. Press T or S to select an item from the Installation menu. 4. P ...

  • Furuno 1835 - page 30

    3-4 Antenna Rotation: "Rotate" (default setting) transmits the radar pulses with rotating the antenna. "Stop" transmits the radar pulses without rotating the antenna. Antenna Height: Set the height of the antenna above the water surface. The options are 5, 10, 15, 20, 30, 40 and 50 m. The default setting is 15 m. Near STC Level: ...

  • Furuno 1835 - page 31

    3-5 How to automa tica lly set the eq uipme nt The equipment automatic ally adj ust s the tuning, timing and vid eo. Note: Before you do this procedure, t ramsmit t he radar more than 10 minutes on a l ong rang e and check that Sector Bla nk is OFF. 1. Transmit on the maximum range. 2. Select Auto Inst all Setup from th e inst al lation menu and pr ...

  • Furuno 1835 - page 32

    3-6 Manual MBS Adjustment Reduce the main bang (black hole), which appears at the display center on short ranges, as fol- lows. 1. Transmit the radar on the shortest range. 2. Open the Installation menu and select MBS Adjust . 3. Press the ENTER key to show the setting window . 4. Press the cursor pad to reduce the main bang (between 0 and 25). 5. ...

  • Furuno 1835 - page 33

    4-1 4. OPTIONAL EQUIPMENT 4.1 A RP Kit ARP-1 1 The ARP kit provides automatic radar p lotter functions to this radar. Necessary parts Name: ARP kit T ype: ARP-1 1 Code no.: 008-523-050 For details, see the packing list attached to the kit. 1. Unscrew 12 screws and five connector nut s at the rear of the display unit. Rear panel of Display unit Remo ...

  • Furuno 1835 - page 34

    4-2 2. Lift the cover slowly and open i t as shown below . 3. Mate P107 o n the ARP boar d to J 214 on the 0 3P9474 board and fas ten the ARP board wi th four sc rews. 03P9474 J214 Cover Open this direction. T ake care not to damage this cable assembly. A RP board Comfirm that rubber gasket is set securely in the groove around the panel. ...

  • Furuno 1835 - page 35

    4-3 4. Reassemble the display unit. NMEA1 NMEA2 HDG DJ-1 12-24 VDC/ 8.0-3.8A 3 GND 1 + 2 - USB T orque 2.94 ± 0.29 Nm To r q u e 0.78 ± 0.08 Nm To r q u e 0.78 ± 0.08 Nm (12 pcs) OPTION ...

  • Furuno 1835 - page 36

    4-4 4.2 Connect ion of Buzze r an d/or Remote Displ ay You need the cables shown below to connec t the opt ional ext ernal buzzer and remote di splay. • T wo-way cable MJ-A10SPFW0001+R • MJ-A7SPF0007-050 C • MJ-B24LPF0010-x xx+R (xx x: 100, 200 or 300) External buzzer When a target enter s (exist s) in the guar d zone, the optional ex ternal ...

  • Furuno 1835 - page 37

    NAME OUTLINE Q'TY DESCRIPTION/CODE № PACKING L IST 03HD-X-9852 -1 RDP-152-1835-E/C、RDP-152-1935-E/C、RDP-152-1945-E/C 1/1 NAME OUTLINE Q'TY DESCRIPTION/CODE № ユニット UNIT 指示部 DISP LAY U NIT 1 ** RDP-152-1835/19**-E/C 000-014-616-00 予備品 SPARE PARTS 予備品 SPAR E PAR TS 1 SP03-12200 000-08 ...

  • Furuno 1835 - page 38

    %1&'01  6;2' %2 ⇛ޓޓ࿑ 176.+0' ฬޓޓ⒓ 0#/' ᢙ㊂ 36; ↪ㅜ㧛஻⠨ 4'/#4-5 ⇟ภ 01 ဳฬ㧛ⷙᩰ &'5%4+2 6+105   +056#.. #6+10 /#6'4+ #.5 Ꮏ੐᧚ᢱ⴫ (4: ...

  • Furuno 1835 - page 39

    %1&'01 6;2' ⇛ޓޓ࿑ 176.+0' ฬޓޓ⒓ 0#/' ᢙ㊂ 36; ↪ㅜ㧛஻⠨ 4'/#4-5 ⇟ภ 01 ဳฬ㧛ⷙᩰ &'5%4+2 6+105   +056#.. #6+10 /#6'4+ #.5 Ꮏ੐᧚ᢱ⴫ *&: /1&'. 㩃㨺㩖㩨㩣⚵ຠ/, %#$.'# ...

  • Furuno 1835 - page 40

    %1&'01 6;2' ⇛ޓޓ࿑ 176.+0' ฬޓޓ⒓ 0#/' ᢙ㊂ 36; ↪ㅜ㧛஻⠨ 4'/#4-5 ⇟ภ 01 ဳฬ㧛ⷙᩰ &'5%4+2 6+105   +056#.. #6+10 /#6'4+ #.5 Ꮏ੐᧚ᢱ⴫ *&: /1&'. 㩃㨺? ...

  • Furuno 1835 - page 41

    Y. Hatai D-1 ...

  • Furuno 1835 - page 42

    8/Jul/09 R.Esumi D-2 ...

  • Furuno 1835 - page 43

    5/Feb/09 R.Esumi D-3 ...

  • Furuno 1835 - page 44

    5/Feb/09 R.Esumi D-4 ...

  • Furuno 1835 - page 45

    1 2 3 WHT BLK クロ シロ 10A:12V 5A:24V 1 2 3 (+) (-) 5 6 IV-2sq. *1 12-24 VDC MJ-A3SPF0017-050ZC,5m,φ10 DPYC-1.5 100/110/ 220/230VAC 1φ,50/60Hz *1 MJ-A3SPF RECTIFIER 整流器 PR-62 *2 *4 2 4 3 A 1 B C DRAWN CHECKED APPROVED DWG.No. TITLE NAME 名称 INTERCONN ECTION DIAGR AM 相互結線図 REF.No. SCALE MASS kg T.YAMASAKI MODEL 1835 船舶? ...

  • Furuno 1835 - page 46

    1 2 3 WHT BLK クロ シロ 10A:12V 5A:24V (+) (-) IV-2sq. *1 12-24 VDC MJ-A3SPF0017-050ZC,5m,φ10 MJ-A3SPF *4 2 4 3 A 1 B C DRAWN CHECKED APPROVED DWG.No. TITLE NAME 名称 REF.No. SCALE MASS kg T.YAMASAKI 注記 *1)造船所手配。 *2)オプション。 *3)シールドは両ユニットで完全に接 地すること。 NOTE * ...

  • Furuno 1835 - page 47

    ...

  • Furuno 1835 - page 48

    The paper used in this manual is elemental chlorine free. ・FURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, Nishinomiya, 662-8580, JAPAN Telephone : +81-(0)798-65-2111 Fax : +81-(0)798-65-4200 A : FEB 2009 . Printed in Japan All rights reserved. B1 : NOV . 19, 2009 Pub. No. IME-35790-B1 *00017025111* *00017025111* ( TATA ) MODEL1835/1935/1 ...

Fabricante Furuno Categoría Marine RADAR

Los documentos del dispositivo Furuno 1835 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Furuno
- manuales de instrucciones 1835
- hojas de producto Furuno
- folletos informativos
- o etiquetas energéticas Furuno 1835
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Furuno 1835.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Furuno 1835, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Furuno 1835. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Furuno 1835.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Furuno 1835, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Furuno 1835. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Furuno 1835.

El manual de instrucciones completo de Furuno debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Furuno 1835 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Furuno 1835, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Furuno 1835 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Furuno 1835 - que deben facilitarnos los primeros pasos durante el uso de Furuno 1835
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Furuno 1835
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Furuno 1835 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Furuno 1835?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Furuno 1835, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Furuno 1835 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen