    2761 Getting Started and Operating Instructions 470.620.022 Printed in Germany 2/1998 Subject to technical modifications ...

  • Soehnle 2761 - page 2

    _ Getting started 1 Set up the weighing platform at the place requir ed Use the water level and the adjustable feet to ensure that the scale is positioned horizontally . Fit the indicator or mount on the wall using the bracket provided. Connect the device to the mains The scale is ready for use The order in which the scales can be connected Space f ...

  • Soehnle 2761 - page 3

    On - Off Switch on (only when the scales are not loaded) After the test routine, the main display is set to zero. The scales are r eady for use. Switching between the scales Higher resolution (hold down the key) Zero setting Gross weight Data-transmission (printer/EDP) Switching between kg and lb Enter organisational data Component weighing Ta r e ...

  • Soehnle 2761 - page 4

    An acoustic signal confirms that the entry is correct Incorrect entries ar e indicated by means of five acoustic signals in swift sucession. Please check that your entry is correct. If necessary , cancel the command sequence by pressing the ”CI” key . Loading values Loading the value which is in the secon- dary display or which has been entered ...

  • Soehnle 2761 - page 5

    _ Display symbols main display secondary display 4 Zero message Standstill indication Active range in the case of multi-range scales. Percentage display Empty message Set points activated Gross weighing Net weighing T ar e display When battery is used (accessories): charge level Status switching and checking T otals memory Active scale Components w ...

  • Soehnle 2761 - page 6

    If the tare weight is unknown Determine the tare of the empty container Scales are r eady to perform net weighing If necessary , clear the tare after unloading the scale If the tare weight is known Place the filled container on the scale. Enter the tare weight in kg using the numeric keyboard. Confirm your entry by pressing the ”T” function key ...

  • Soehnle 2761 - page 7

    _ T otalling weights 6 T ar e the container if necessary . Place the items to be weighed on the scale. T ransfer the weight value to the totals memory . T ake the items take weighed of f the scale. Clear the tare if necessary If necessary , enter a new tare. Place the next items to be weighed on the scale. T ransfer the weight value to the totals m ...

  • Soehnle 2761 - page 8

    _ Weighing using the r emoval method _ *see component weighing 7 Place the filled container on the scale. If the tare is known , enter it manually if necessary and tare the weight. If it is important to determine the weight of the remainder: T ransfer the weight value to the totals memory . Press function key ”T”. The overall weight appears as ...

  • Soehnle 2761 - page 9

    _ Components weighing 8 T ar e the container if necessary Place the items to be weighed on the scale. T ransfer the weight value to the component weighing memory . The K-mode is indicated by an arrow . Place the next items to be weighed on the scale. T ransfer the weight value to the commission memory , etc. Place the next items to be weighed on th ...

  • Soehnle 2761 - page 10

    _ Switching and checking in the weighing mode 9 Set points (limit values) can only be set in weighing and counting mode. 3 memories for limit values are available for each connected scale: Entry must be additive, i.e. the weight of first limit value should be added to the second. Limit values affect the net weight. Loading memory Enter the value fo ...

  • Soehnle 2761 - page 11

    _ Switching and checking in the counting mode 10 Loading memory Enter number of pieces for set point with the numeric keyboard. Press the ”Ld” command key , followed by the number of the memory . Confirm your entry by pressing the function key . Memories 2 and 3 are enter ed and displayed in the same way . Recalling of stored values Press the ? ...

  • Soehnle 2761 - page 12

    _ Counting 11 Switch the scale to counting mode. Determining the refer ence weight T ar e the empty container if necessary . Place the number of items requested by the scale or enter the refer ence number of items requir ed by the numerical key board, take over with key , place entered number of items on the scale and press the ” ” function key ...

  • Soehnle 2761 - page 13

    _ T otalling quantities Determine the number of pieces. T ransfer this to the totals memory (in the secondary display) Remove the items from the scale. Clear the tare if necessary . Determine a new tare if necessary . Place the next quantity on the scale. T ransfer it to the totals memory , etc. Known quantities can be entered manually using the nu ...

  • Soehnle 2761 - page 14

    _ Removal method 13 Unknown number of pieces and item weight Determine the number of pieces(without tare) T o determine the r emaining number of pieces: transfer the number of pieces to the totals memory . Set the display to zero by pr essing the ”T” funktion key . The removal of items is indicated by a minus sign. Press the ”+” function ke ...

  • Soehnle 2761 - page 15

    _ Printing Key functions Single print Print - add to totals memory Print totals and clear memory Print - add to component weighing memory Print totals and clear memory Entering organisational data A 40- digit number can be assigned to each memory of the three organisational data memories. Enter the data using the numeric keyboard. Press the ”Ld? ...

  • Soehnle 2761 - page 16

    Activating user modification Press the ”i” key and ”On/Of f” at the same time. User modification functions Calibration step selection, forwards Calibration step selection, backwards Moving the tens column forward within a program step, fr om left to right Moving pre-assigned values forwar d Confirm and transfer the value of the main indicat ...

  • Soehnle 2761 - page 17

    Always column 00 Positioning on the right side 00XX B XX Gross weight 15 G XXXXX,XX <Unit> 01XX D XX Date 8 XX.XX.XX 02XX d XX Date 1x 8 for pressing tke key just once 03XX E XX Orga-data 1 No. 1 XXX... max. 39 pos. 04XX e XX Titel Org. 1 blank 05XX F XX Orga-data 2 No. 2 XXX... max. 39 pos. 06XX f XX Titel Org. 2 blank 07XX G XX Orga-data 3 ...

  • Soehnle 2761 - page 18

    Indicator An acoustic signal confirms that entry was correct Incorrect entries ar e indicated by 5 acoustic signals in swift succession. The scale sets the value zero automatically when it is switched on. If the scales are outside the set tolerance range, -0- is displayed. Underload: only the bottom horizontal lines appear on the display . Overload ...

  • Soehnle 2761 - page 19

    18 _ T echnical information • The housing is made from pr essure-moulded, powder -coated aluminium (RAL 9006) • Dimensions 258 x 193 x 73 mm • Protection type IP 65, dust pr oof and splash-proof • Operated by means of a tactile keypad with acoustic acknowledgement • Mains operation with power supply unit, 230 V 50-60Hz, approx. 20V A • ...

Fabricante Soehnle Categoría Scale

Los documentos del dispositivo Soehnle 2761 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Soehnle
- manuales de instrucciones 2761
- hojas de producto Soehnle
- folletos informativos
- o etiquetas energéticas Soehnle 2761
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Soehnle 2761.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Soehnle 2761, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Soehnle 2761. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Soehnle 2761.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Soehnle 2761, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Soehnle 2761. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Soehnle 2761.

El manual de instrucciones completo de Soehnle debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Soehnle 2761 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Soehnle 2761, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Soehnle 2761 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Soehnle 2761 - que deben facilitarnos los primeros pasos durante el uso de Soehnle 2761
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Soehnle 2761
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Soehnle 2761 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Soehnle 2761?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Soehnle 2761, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Soehnle 2761 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)