  • Vulcan-Hart GRC85 ML-052307 - page 1

    VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791 INSTALLATION & OPERATION MANUAL GRD AND GRC SERIES GAS FRYERS MODELS GRD25 ML-052513 GRD35 ML-052080 GRD45 ML-052081 GRD65 ML-052082 GRD85 ML-052306 GRC35 ML-052083 GRC45 ML-052084 GRC65 ML-052085 GRC85 ML-052307 GRD35F ML-126732 GRD45F ML-126735 GRD65F ML-126738 ...

  • Vulcan-Hart GRC85 ML-052307 - page 2

    – 2 – IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBT ...

  • Vulcan-Hart GRC85 ML-052307 - page 3

    – 3 – TABLE OF CONTENTS GENERAL ............................................................................................................................................. 5 SPECIFICATIONS ......................................................................................................................... 5 OPTIONS AND FEATURES .......... ...

  • Vulcan-Hart GRC85 ML-052307 - page 4

    – 4 – TABLE OF CONTENTS (Cont.) GRC SERIES ..................................................................................................................................... 2 1 CONTROLS .................................................................................................................................. 21 PROGRAMMING .......... ...

  • Vulcan-Hart GRC85 ML-052307 - page 5

    – 5 – INSTALLATION, OPERATION AND CARE OF MODELS GRD AND GRC SERIES GAS FRYERS PLEASE KEEP THIS MANUAL FOR FUTURE USE GENERAL Vulcan GRD and GRC Series Gas Fryers are produced with quality workmanship and material. Proper installation, usage and maintenance of your fryer will result in many years of satisfactory performance. It is suggested tha ...

  • Vulcan-Hart GRC85 ML-052307 - page 6

    – 6 – OPTIONS AND FEATURES • Stainless Steel Tank (Standard) • Basket Lift with Timer (GRD and GRC series) • Tri-, Twin- or Single-Basket (GRD and GRC series) • Manual Pilot or Electronic Ignition (GRD and GRC series) • Filter-Ready (Stand-alone fryers only) • KleenScreen Filtration System (F models only) BATTERY CONFIGURATIONS • ...

  • Vulcan-Hart GRC85 ML-052307 - page 7

    – 7 – 3 Cabinets in Battery Filter Filter Filter Fryer Fryer Fryer AB C Fryer Dump Fryer A BC Fryer Fryer Dump AB C Filter A B C Dump Fryer Fryer 4 Cabinets in Battery (For 35, 45 and Electric 50 Only) AB C D Filter Fryer Fryer Fryer Dump AB C D Filter Fryer Dump Fryer Fryer ABC D Filter Fryer Fryer Dump Fryer AB C D Filter Dump Fryer Fryer Fry ...

  • Vulcan-Hart GRC85 ML-052307 - page 8

    – 8 – Sizes Heat Lamp Tops 35 & 45 Opt. Drain Pan Perforated Std. N/A 65 & 85 Opt. Std. Opt. FIELD-INSTALLED ACCESSORIES FACTORY-INSTALLED OPTIONS • Casters • Basket Lift • Twin Baskets • Battery Configuration • Tri-Baskets (65 and 85 models only) • Battery Interplumbing (F models only) • Single Baskets • Electronic Igni ...

  • Vulcan-Hart GRC85 ML-052307 - page 9

    – 9 – INSTALLATION Before installing the fryer, verify that the type of gas (natural or propane) agrees with the specifications on the fryer data plate, which is located on the inside of the door panel. Ensure the fryer is configured for the proper elevation. UNPACKING This fryer was carefully inspected before leaving the factory. The transport ...

  • Vulcan-Hart GRC85 ML-052307 - page 10

    – 10 – LOCATION The equipment area must be kept free and clear of combustible substances. Minimum clearance from combustible construction is 6" (15 cm) from the sides and 6" (15 cm) from the back of the fryer. Minimum clearance from noncombustible construction is 0" from the sides and 0" from the back. At least 16" (41 ...

  • Vulcan-Hart GRC85 ML-052307 - page 11

    – 11 – ASSEMBLY When installed, the fryer must be restrained to prevent tipping in to avoid the splashing of hot liquid. The means of restraint may be the manner of installation, such as connection to a battery of appliances or installing the fryer in an alcove, or by separate means, such as adequate ties. Fryers Mounted on Legs (Non-Batteried ...

  • Vulcan-Hart GRC85 ML-052307 - page 12

    – 12 – GAS CONNECTIONS CAUTION: All gas supply connections and any pipe joint compound must be resistant to the action of propane gases. The gas inlet is located on the lower right rear of the fryer. Codes require that a gas shutoff valve be installed in the gas line ahead of the fryer. The gas supply line must be at least the equivalent of 1 / ...

  • Vulcan-Hart GRC85 ML-052307 - page 13

    – 13 – LEVELING FRYER 1. Place a spirit level on top of the fryer after gas connections have been made. 2. Adjust the legs to ensure that the fryer is level front-to-back and side-to side in the final installed position. FLUE CONNECTIONS The fryer must be located under a hood with adequate connection to an exhaust duct. The hood must extend 6&q ...

  • Vulcan-Hart GRC85 ML-052307 - page 14

    – 14 – Fig. 4 OPERATION WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. WARNING: SPILLING HOT FRYING COMPOUND CAN CAUSE SEVERE BURNS. DO NOT MOVE FRYER WITHOUT DRAINING ALL FRYING COMPOUND FROM THE TANK. BEFORE FIRST USE • Clean the protective metal oils from all surface parts and the tan ...

  • Vulcan-Hart GRC85 ML-052307 - page 15

    – 15 – LIGHTING INSTRUCTIONS FOR MANUAL PILOT IGNITION (Fig. 6) CAUTION: Before turning the burners on, the fry tank must be filled with liquid or melted shortening. Fig. 6 1. Turn thermostat knob (located behind the door panel) to OFF. 2. Push gas valve extension arm in and turn arm to OFF. Wait 5 minutes for unburned gas to vent. 3. Push gas ...

  • Vulcan-Hart GRC85 ML-052307 - page 16

    – 16 – STARTUP WITH ELECTRONIC IGNITER CAUTION: Before turning the burners on, the fry tank must be filled with liquid or melted shortening. 1. Plug the power cord into an appropriate grounded receptacle and turn the main gas valve on. 2. Fill the fry tank with shortening. If using solid shortening, the fryer must be equipped with a melt cycle. ...

  • Vulcan-Hart GRC85 ML-052307 - page 17

    – 17 – CONTROL DESCRIPTION Power switch; for turning the fryer on or off. For cleaning purposes when the fryer is filled with water. Tem- perature is maintained at approxmiately 192°F (89°C). For entering and exiting the program mode. For scrolling through program parameters. Raises and lowers left fry basket (optional). Starts and stops the ...

  • Vulcan-Hart GRC85 ML-052307 - page 18

    – 18 – PARAMETER SELECT DISPLAY SCROLL Left Timer Pr e ss or to en te r t im e. LED is lit above the left b asket icon. The time value is displayed in window. P re ss an d scroll to next item. Right Time r Pr e ss or to en te r t im e. LED is lit abo ve the right basket icon. The time value is displayed in window. P re ss an d scroll to next it ...

  • Vulcan-Hart GRC85 ML-052307 - page 19

    – 19 – Melt Options (GRD Series) When using solid shortening in the fryer, the CY S (solid shortening) option must be used. Solid shortening must be gently warmed to a liquid state before heating to frying temperatures. Melting solid shortening without using this option will damage the fry tank and scorch the shortening. The controller has thre ...

  • Vulcan-Hart GRC85 ML-052307 - page 20

    – 20 – USING THE FRYER (After Startup) Models Without Basket Lift Option 1. Load the fry basket(s); do not overfill. See Recommended Basket Capacities on page 30. 2. Carefully lower basket(s) into shortening. 3. Press to start the left timer. Press to start the right timer. 4. When the timer times out, a beeper sounds. Press to silence the left ...

  • Vulcan-Hart GRC85 ML-052307 - page 21

    – 21 – GRC SERIES CONTROLS GRC Series Fryers have a microprocessor (computer) thermostat and timer. Control Guide ...

  • Vulcan-Hart GRC85 ML-052307 - page 22

    – 22 – PARAMETER STEPS LEFT DISPLAY RIGHT DISPLAY Press SELECT OPTIONS Press DEGREES F or C F or C Press to select Fahrenheit or Celsius. DEGREES F or C F or C Press when complete. PROGRAM Press SELECT OPTIONS Press SET PASS NEW PASS Press to select NO PASS. NO PASS NEW PASS Press when complete. PROGRAM Press SELECT OPTIONS Press SET PASS NEW P ...

  • Vulcan-Hart GRC85 ML-052307 - page 23

    – 23 – PARAMETER STEPS LEFT DISPLAY RIGHT DISPLAY Press SELECT OPTIONS Press ENGLISH (Factory Default) LANGUAGE Press to select a language. ENGLISH/ESPANOL FRANCAIS/DEUTSCH HOLLAND Press when complete. PROGRAM Press SELECT OPTIONS Press NO MELT/LIQUID/SOLID Press to select melt options. NO MELT/LIQUID/SOLID Press when complete. PROGRAM Press SE ...

  • Vulcan-Hart GRC85 ML-052307 - page 24

    – 24 – Melt Options (GRC Series) When using solid shortening in the fryer, the SOLID melt option must be used. Solid shortening must be gently warmed to a liquid state before heating to frying temperatures. Melting solid shortening without using this option will damage the fry tank and scorch the shortening. The controller has three options for ...

  • Vulcan-Hart GRC85 ML-052307 - page 25

    – 25 – TEMPERATURE AND TIME PROGRAMMING Temperature 1. Press to enter program mode. PROGRAM is displayed in the window. 2. Press to enter temperature mode. 000°F and TEMP are displayed in the window. 3. Press through to enter desired fry temperature. The fry temperature is displayed in the window. 4. Press to exit the temperature mode. Press a ...

  • Vulcan-Hart GRC85 ML-052307 - page 26

    – 26 – Timers through : 1. Press and enter the program mode. PROGRAM is displayed in the window. 2. Press . The LED's on timers through are lit and SELECT PRODUCT is displayed in the window. 3. To select a timer, press one of the lit timer numbers; CK# 00:00 and TIME are displayed in the window. 4. Enter the desired time using keys through ...

  • Vulcan-Hart GRC85 ML-052307 - page 27

    – 27 – Setting Advanced Time Features 1. Press and enter the program mode. 2. Press for timers through , or press for timers through . The LEDs are lit on the timers available for programming, and SELECT PRODUCT is displayed in the window. 3. Select a timer; the programmed time is displayed in the window. A. Duty Time : 1) Press either arrow on ...

  • Vulcan-Hart GRC85 ML-052307 - page 28

    – 28 – Time Programming Quick Chart Press to enter the program mode Press for timers to Press for timers to Select a Timer Press t o continue Set HOLD Time Select COMP or STRAIGHT Press Press Set DUTY Time Press Exit Program Enter Time Using to ...

  • Vulcan-Hart GRC85 ML-052307 - page 29

    – 29 – USING THE FRYER (After Startup) Models Without Basket Lift Option 1. Load the fry basket(s), do not overfill. See Recommended Basket Capacities on page 30. 2. Carefully lower basket(s) into shortening. 3. Press the desired number to start the timer. Timers through are for the left basket and through are for the right basket. 4. When the ...

  • Vulcan-Hart GRC85 ML-052307 - page 30

    – 30 – FRYING GUIDELINES (All Models) • Heat shortening to set temperature. • Fry pieces of product that are about the same size together. • Drain or wipe dry raw or wet foods to minimize splatter when lowering into the hot shortening. • Keep shortening between the MIN and MAX lines. Shortening will expand when heated; do not fill the f ...

  • Vulcan-Hart GRC85 ML-052307 - page 31

    – 31 – DAILY FILTERING WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. Filtering Guidelines (All Models) • Stand alone fryers are available in filter-ready and non-filter-ready versions. • Battery interplumbing is available only on fryers equipped with KleenScreen. • A cold fryer will ...

  • Vulcan-Hart GRC85 ML-052307 - page 32

    – 32 – Battery Interplumbing (Only Available on KleenScreen Models) A battery of fryers equipped with optional interplumbing connects the fry tanks to a common drain. Each tank has an individual drain valve. Only one tank can be filtered at a time. Instructions for the KleenScreen filtering system are covered in a separate manual. Follow the in ...

  • Vulcan-Hart GRC85 ML-052307 - page 33

    – 33 – CLEANING WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. DAILY • Clean all exterior surfaces of your fryer at least once daily. • Use a damp cloth with warm water and a mild soap or detergent. • Rinse thoroughly, then polish with a soft, dry cloth. • Keep the fryer exterior c ...

  • Vulcan-Hart GRC85 ML-052307 - page 34

    – 34 – 10. Drain the tank. 11. Rinse the tank thoroughly with clear, hot water (all traces of cleaner must be removed). 12. Dry the tank thoroughly. 13. Close the drain valve and add shortening. 14. Shortening level should be between the MIN and MAX lines. Shortening will expand when heated; do not fill the fry tank past the MAX line. The fryer ...

  • Vulcan-Hart GRC85 ML-052307 - page 35

    – 35 – TROUBLESHOOTING GUIDE SYMPTOM POSSIBLE CAUSES No power when switch is turned on . Tripped ex ternal breaker; external fuse blown. Verify fryer is plugged in and/or check external circuit br eakers and/or fuse. Problem with power swi tch; call service. Problem wit h high li mit; call service. Fryer will not heat. Gas supply not on or part ...

  • Vulcan-Hart GRC85 ML-052307 - page 36

    – 36 – FORM 31214 Rev. B (07-03) PRINTED IN U.S.A. ALARMS AND ERROR MESSAGES (GRD and GRC Series) Pilot Out - If the pilot is out, the control displays the following message: GRD Models - FIrE OUt GRC Models - PILOT OUT If no action is taken after 90 seconds, an alarm sounds continuously, the heat demand is disabled and any running cooking cycl ...

Fabricante Vulcan-Hart Categoría Fryer

Los documentos del dispositivo Vulcan-Hart GRC85 ML-052307 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Vulcan-Hart
- manuales de instrucciones GRC85 ML-052307
- hojas de producto Vulcan-Hart
- folletos informativos
- o etiquetas energéticas Vulcan-Hart GRC85 ML-052307
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Vulcan-Hart GRC85 ML-052307.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Vulcan-Hart GRC85 ML-052307, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Vulcan-Hart GRC85 ML-052307. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Vulcan-Hart GRC85 ML-052307.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Vulcan-Hart GRC85 ML-052307, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Vulcan-Hart GRC85 ML-052307. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Vulcan-Hart GRC85 ML-052307.

El manual de instrucciones completo de Vulcan-Hart debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Vulcan-Hart GRC85 ML-052307 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Vulcan-Hart GRC85 ML-052307, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Vulcan-Hart GRC85 ML-052307 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Vulcan-Hart GRC85 ML-052307 - que deben facilitarnos los primeros pasos durante el uso de Vulcan-Hart GRC85 ML-052307
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Vulcan-Hart GRC85 ML-052307
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Vulcan-Hart GRC85 ML-052307 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Vulcan-Hart GRC85 ML-052307?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Vulcan-Hart GRC85 ML-052307, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Vulcan-Hart GRC85 ML-052307 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)