Manual de instrucciones Lincoln Electric IM420-D

35 de páginas 2.7 mb
Descargar

Pasar a la página of 35

Summary
  • Lincoln Electric IM420-D - page 1

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • OPER A T OR’S MANU AL IM420-D February, 2010 Safety Depends on You Lincoln arc welding and cutting equipment i ...

  • Lincoln Electric IM420-D - page 2

    FOR ENGINE pow ered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. _______________________________________________ ...

  • Lincoln Electric IM420-D - page 3

    ARC R A Y S can bur n. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4. b . Use suitable clothing made from durable flame-resistant material to protect your skin and tha ...

  • Lincoln Electric IM420-D - page 4

    FOR ELECTRIC ALL Y pow ered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8 . b . Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations. 8.c. Ground the equipment in accordance with the U.S. National Electri ...

  • Lincoln Electric IM420-D - page 5

    PRÉC A UTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1. Protegez-vous contre la secousse électrique: a. Les circuits à l’élec ...

  • Lincoln Electric IM420-D - page 6

    ix ix Thank Y ou for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. ...

  • Lincoln Electric IM420-D - page 7

    x x T ABLE OF CONTENTS Page Installation .......................................................................................................................Section A Technical Specifications .......................................................................................................A-1 Safety Precautions . ........................... ...

  • Lincoln Electric IM420-D - page 8

    A -1 INS T ALLA TION IDEALARC® DC-1000 A -1 60% Duty Cycle 215/108 86 215/124/108 124/94 113 TECHNICAL SPECIFICA TIONS – DC-1000 Volts at Rated Amperes 44 44 44 Auxiliary Power See the OPERATION section for Auxiliary Power information by model Amps 1000 1140 1250 Maximum Open Circuit Voltage 75V for 60 HZ models 72V for 50/60 HZ models Duty Cycl ...

  • Lincoln Electric IM420-D - page 9

    A-2 INS T ALLA TION IDEALARC® DC-1000 A-2 A permanent lifting eye is located at the top of the machine and is positioned so that it acts as nearly as possible through the center of gravity. This lift eye fits under the case of the second machine without interference when stacking. ST ACKING Two DC-1000’s may be stacked by observing the following ...

  • Lincoln Electric IM420-D - page 10

    A-3 INS T ALLA TION IDEALARC® DC-1000 A-3 RECONNECT PROCEDURE Multiple voltage machines are shipped connected to the highest input voltage listed on the machine’s rating plate. Before installing the machine, check that the Reconnect Panel in the Input Box Assembly is con- nected for the proper voltage. Failure to follow these instructions can ca ...

  • Lincoln Electric IM420-D - page 11

    A-4 INS T ALLA TION IDEALARC® DC-1000 A-4 FIGURE 2 FIGURE 3 ...

  • Lincoln Electric IM420-D - page 12

    A-5 INS T ALLA TION IDEALARC® DC-1000 A-5 OUTPUT CONNECTIONS Output Studs The output leads are connected to the output termi- nals. The output terminals are located on the lower case front and labeled “+” and “-”. There are 1000 amp rated “+” terminals on the right side, one 500 amp rated “+” terminal near the center and “-” te ...

  • Lincoln Electric IM420-D - page 13

    B-1 OPER A TION IDEALARC® DC-1000 B-1 PRODUCT DESCRIPTION The DC-1000 is an SCR-contr olled three phase DC power source. It is designed with a single range potentiometer control for submerged arc or open arc automatic and semiautomatic welding. It can be used for air carbon arc cutting with carbon rods up to and including 5/8” (15.9mm) dia. The ...

  • Lincoln Electric IM420-D - page 14

    B-2 INS T ALLA TION IDEALARC® DC-1000 B-2 Remote Output Control - (Optional) The K775 Remote Output Control consists of a control box with 28 ft. (8.4m) of four conductor cable. This connects to terminals 75, 76, 77 on the terminal strip, and the case grounding screw so marked with the symbol on the machine. These terminals are made available by o ...

  • Lincoln Electric IM420-D - page 15

    B-3 INS T ALLA TION IDEALARC® DC-1000 B-3 3. N A - 5 - Set the DC-1000 mode switch to the proc ess bein g us ed - CV (I) Inner shie ld or C V(S) Sub Arc. Set the DC-1000 machine/remote switch in the remote position. Set the OCV control four volts higher than the welding voltage and the inch speed at 1/2 the welding wire feed speed for the initial ...

  • Lincoln Electric IM420-D - page 16

    D-1 MAINTENANCE D-1 The control board is designed with adequate protec- tion so that no damage will occur if the remote control l ea d s a r e s h o r te d to g e th e r o r ar e g r o u nd e d t o th e case. The machine will automatically shut down if such faults do occur. An 8-amp fuse located on the machine control panel protects the 115 volt au ...

  • Lincoln Electric IM420-D - page 17

    E-1 TR OUBLESHOO TING E-1 IDEALARC® DC-1000 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. C A UTION This Troubleshooting Guide is provided to help you locate and ...

  • Lincoln Electric IM420-D - page 18

    E-2 TR OUBLESHOO TING E-2 IDEALARC® DC-1000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. C A UTION ...

  • Lincoln Electric IM420-D - page 19

    E-3 TR OUBLESHOO TING E-3 IDEALARC® DC-1000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. C A UTION ...

  • Lincoln Electric IM420-D - page 20

    E-4 TR OUBLESHOO TING E-4 IDEALARC® DC-1000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. C A UTION ...

  • Lincoln Electric IM420-D - page 21

    E-5 TR OUBLESHOO TING E-5 IDEALARC® DC-1000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. C A UTION ...

  • Lincoln Electric IM420-D - page 22

    E-6 TR OUBLESHOO TING E-6 IDEALARC® DC-1000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. C A UTION ...

  • Lincoln Electric IM420-D - page 23

    E-7 TR OUBLESHOO TING E-7 IDEALARC® DC-1000 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. C A UTION MACHINE HAS OUTPUT (Jumper 2-4) BUT TRIPS OFF IMMEDIATELY CHEC ...

  • Lincoln Electric IM420-D - page 24

    F-1 DIA GR AMS F-1 IDEALARC® DC-1000 CONNECTION OF DC-1000 WITH NL OPTION KIT TO LAF-3 (Obsolete) N.A. On all DC-1000 and DC-1500 units with codes above 8234 extend lead 67 and connect it to the electrode cable going to the automatic equip- ment. N.B. On DC-1500 units below code 8234 this is 67 and the LAF-3 #67 lead can be connected either to the ...

  • Lincoln Electric IM420-D - page 25

    F-2 DIA GR AMS F-2 IDEALARC® DC-1000 CONNECTION OF DC-1000 WITH NL OPTI ON KIT TO L T -3 or L T -34 (Obsolete) N.A. On all DC-1000 and DC-1500’s above Code 8234 extend lead 67 and connect it to the electrode cable going to the automatic equipment. N.B. On DC-1500 units below code 8234 this is #67 and the LT-3 or LT-34 #67 lead can be connected e ...

  • Lincoln Electric IM420-D - page 26

    F-3 DIA GR AMS F-3 IDEALARC® DC-1000 CONNECTION OF DC-1000 to NA-5 N.A. Welding cables must be of proper capacity for the cur- rent and duty cycle of immediate and future applica- tions. N.B. Extend lead 21 using #14 or larger insulated wire phys- ically suitable for the installation. An S16586-[ ] remote voltage sensing work lead is available for ...

  • Lincoln Electric IM420-D - page 27

    F-4 DIA GR AMS F-4 IDEALARC® DC-1000 CONNECTION OF DC-1000 TO LN-7 CONNECTION OF DC-1000 TO LN-9 N.A. Welding cables must be of proper capacity for the current and duty cycle of immediate and future applications. N.B. Extend lead 21 using #14 or larger insulated wire physically suit- able for the installation. An S16586-[ ] remote voltage sensing ...

  • Lincoln Electric IM420-D - page 28

    F-5 DIA GR AMS F-5 IDEALARC® DC-1000 DC-1000 WIRING DIAGRAM FOR CODES 9919 - 9925, 10293, 1 1305, 1 1330, 1 1331, 1 1332, 1 1333, 1 1334 NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If ...

  • Lincoln Electric IM420-D - page 29

    F-6 DIA GR AMS F-6 IDEALARC® DC-1000 NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment cod ...

  • Lincoln Electric IM420-D - page 30

    NO TES IDEALARC® DC-1000 ...

  • Lincoln Electric IM420-D - page 31

    NO TES IDEALARC® DC-1000 ...

  • Lincoln Electric IM420-D - page 32

    NO TES IDEALARC® DC-1000 ...

  • Lincoln Electric IM420-D - page 33

    W ARNING A VISO DE PREC A UCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INS TR UCTION FOR THIS EQUIPMENT AND THE CONSUMABLES T O BE USED AND FOLL O W Y OUR EMPL O YER’S SAFETY PRA CTICES. SE RECOMIEND A LEER Y ENTENDER LAS INS TRUCCIONES DEL F ABRIC ...

  • Lincoln Electric IM420-D - page 34

    W ARNING A VISO DE PREC A UCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREEND A AS INS TR UÇÕES DO F ABRIC ANTE P ARA ES TE EQUIP AMENT O E AS P ARTES DE USO , E SIGA AS PRÁTIC AS DE SE GURANÇA DO EMPRE GADOR. • Kee p yo ur h ead out of f umes . • Use ven tila tion or exha us ...

  • Lincoln Electric IM420-D - page 35

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • ...

Fabricante Lincoln Electric Categoría Welder

Los documentos del dispositivo Lincoln Electric IM420-D que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Lincoln Electric
- manuales de instrucciones IM420-D
- hojas de producto Lincoln Electric
- folletos informativos
- o etiquetas energéticas Lincoln Electric IM420-D
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Lincoln Electric IM420-D.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Lincoln Electric IM420-D, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Lincoln Electric IM420-D. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Lincoln Electric IM420-D.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Lincoln Electric IM420-D, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Lincoln Electric IM420-D. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Lincoln Electric IM420-D.

El manual de instrucciones completo de Lincoln Electric debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Lincoln Electric IM420-D - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Lincoln Electric IM420-D, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Lincoln Electric IM420-D que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Lincoln Electric IM420-D - que deben facilitarnos los primeros pasos durante el uso de Lincoln Electric IM420-D
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Lincoln Electric IM420-D
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Lincoln Electric IM420-D en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Lincoln Electric IM420-D?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Lincoln Electric IM420-D, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Lincoln Electric IM420-D probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)