    PM559 - Issue 1 (June 201 1) Y eoman CL Milner Brick Inset Convector Stove MODELS: YMMB Instructions for Use, Installation and Servicing For use in GB & IE (Great Britain and Republic of Ireland). IMPORTANT This appliance will become hot whilst in operation, it is therefore recommended that a suitable guard should be used for the protection of ...

  • Yeoman YMMB - page 2

    COVERING THE FOLLOWING MODELS: YMMB 2 COMMISSIONING 23 MAINTENANCE & SERVICING 24 Annual Service 24 Removal of Log Guard 25 Removal of Baffle 25 Removal of Grate 25 Removal of Fire Bricks 25 Fitting a New Door Glass 25 Fitting a New Door Seal 26 Adjusting The Door Catch 27 SPARE PARTS 28 SERVICE RECORDS 30 EC DECLARATION OF CONFORMITY 31 APPLIA ...

  • Yeoman YMMB - page 3

    3 APPLIANCE COMMISSIONING CHECKLIST To assist us in any guarantee claim please complete the following information. In the unlikely event of a problem, contact your installer or retailer for assistance: Retailer appliance was purchased from Name: ........................................................................................................ ...

  • Yeoman YMMB - page 4

    4 USER INSTRUCTIONS 1. GENERAL POINTS 1.1 Before installation and/or use of this appliance please read these instructions carefully to ensure that all requirements are fully understood. The appliance must be fitted by a registered installer*, or approved by your local building control officer. 1.2 All local regulations, including those referring to ...

  • Yeoman YMMB - page 5

    5 USER INSTRUCTIONS AIRWASH AND PRIMARY AIR CONTROLS 3 PR9025 Op en C l o s e Op en C l o s e Airwash Control Primary Air Control SECONDARY AIR CONTROLS 4 PR9026 Secondary Air Control In - Closed Out - Open DOOR HANDLE 1.13 Use a protected gloved hand to operate. 1.14 Rotate clockwise and pull to open. Warning: Do not force the handle as damage may ...

  • Yeoman YMMB - page 6

    6 USER INSTRUCTIONS 3. RECOMMENDED FUELS 3.1 Wood Logs: Burn only seasoned timber with a moisture content of less than 20%. To ensure this allow cut wood to dry for 12 to 18 months. Wood Length 6 Appliance Wood Length CL Milner Brick 250mm Poor quality timber: — Causes low combustion efficiency. — Produces harmful condensation. — Reduces effe ...

  • Yeoman YMMB - page 7

    7 USER INSTRUCTIONS 5.5 When in use, burning the appliance at a high temperature for a short period also reduces tars and creosotes. WARNING: DO NOT OPERATE THE APPLIANCE WITH THE PRIMARY AIR CONTROL OPEN FOR LONG PERIODS OF TIME AS THIS COULD CAUSE OVER- FIRING AND MAY CAUSE PERMANENT DAMAGE. 5.6 Burning Solid fuel : — Set air contr ols (see dia ...

  • Yeoman YMMB - page 8

    8 USER INSTRUCTIONS 6. BURNING TIPS 6.1 Fuel Quality (Wood) Use wood with a moisture content of less than 20%. Seasoned logs have the bark beginning to lift and peel away and cracks radiating from the centre. They feel lighter than fresh cut wood of a similar size and sound hollow when struck against each other. Logs should not feel damp or have mo ...

  • Yeoman YMMB - page 9

    9 7. ASH REMOVAL Do not allow ash to build up in the appliance as it will not burn properly and may cause damage. 7.1 Wood — Open doors and using gloves remove ashpan with the tool provided (see Diagram 10). — Remove ash and place into a Yeoman Ash Caddy (Yeoman Part No. 4227) or other suitable container. Do not place hot ash in any container m ...

  • Yeoman YMMB - page 10

    10 13. CHIMNEY SWEEPING 13.1 To maintain safe and efficient use of the appliance, the chimney/flue must be inspected and swept at least once a year by a qualified chimney sweep**. If the appliance is used continuously throughout the year, or it is used to burn wood or smokeless fuel, more frequent sweeping is recommended. The best time to have the ...

  • Yeoman YMMB - page 11

    11 16.3 Glass cracking Do not over tighten the screws on the glass clamp when replacing the glass. This causes stress and the intense temperature changes can cause the glass to crack. For replacement glass contact your local Yeoman retailer. 16.4 Appliance is producing tar This can be identified by: — A very strong pungent smell shortly after the ...

  • Yeoman YMMB - page 12

    12 TECHNICAL SPECIFICATION CL MILNER BRICK • PrimaryAir (under grate air for full Multi-fuel use). • Airwash(for wood burning/clean glass). • Adjustablesecondary air (to ensure complete burning of flue gases). • Riddlinggrate system for clean de-ashing. ? ...

  • Yeoman YMMB - page 13

    13 SITE REQUIREMENTS CL INSET DIMENSIONS PR9036 369 379 593 577 281 520 243 540 103 282 183 104 156 ...

  • Yeoman YMMB - page 14

    14 1. FLUE OR CHIMNEY 1.1 The flue or chimney system must be in good condition. It must be inspected by a competent person and passed for use with the appliance before installation. Products of combustion entering the room can cause serious health risks. 1.2 The following must be checked: — The construction of the masonry chimneys, flue block chi ...

  • Yeoman YMMB - page 15

    15 3.1 The appliance must stand on a non-combustible constructional hearth which is at least 125mm thick with the minimum dimensions as shown in diagram. SITE REQUIREMENTS 3. MINIMUM DIMENSIONS - HEARTH 3.2 If this appliance can be installed in an elevated setting it is recommended to increase the 225mm hearth depth to safely contain any falling lo ...

  • Yeoman YMMB - page 16

    16 5. FIRE SURROUND CLEARANCES If the appliance is to be fitted with a fire surround, use the minimum clearances shown in the diagram below between any point of the appliance and any combustible material. Yeoman produce a selection of surrounds and details can be obtained from your local supplier. 150 mm 300mm 150 mm PR9144 5.1 We recommend you obt ...

  • Yeoman YMMB - page 17

    17 2.7 Ventilation requirements in the UK are as shown in the table below: A) Traditionally Built Homes  •Where the leakage is greater than 5m 3 /hour/m 2 .  •Ventilation normally required = 550mm 2 per kW output over 5kW Output (kw) 4 5 6 7 8 9 10 A Additional ventilation mm 2 None None 550 1100 1650 2 ...

  • Yeoman YMMB - page 18

    18 2.11 Extractor fans or cooker hoods must not be placed in the same room or space as this can cause the appliance to emit fumes into the room. 2.12 Increase air supply provisions where a room contains multiple appliances. 2.13 If any checks reveal problems do not proceed with the fitting of the appliance until they have been rectified. 3. FITTING ...

  • Yeoman YMMB - page 19

    19 LEGAL REQUIREMENTS Before installation and/or use of this appliance please read these instructions carefully to ensure that all requirements are fully understood. The appliance must be fitted by a registered installer * , or approved by your local building control officer. It is very important to understand the requirements of the national Build ...

  • Yeoman YMMB - page 20

    20 INSTALLATION INSTRUCTIONS 2. REMOVAL OF THE DOOR 2.1 To remove the door: — Using a 5mm A/F Hey Key remove the door by opening, removing the 4 bolts and lifting the door free of the appliance body. PR7084 4 Bolts 3. REMOVAL OF THE LOG GUARD 3.1 To remove the log guard: — Lift log guard clear of the supporting brackets. — Rotate to clear the ...

  • Yeoman YMMB - page 21

    21 INSTALLATION INSTRUCTIONS 4.4 To remove the baffle: — Open door. — Lift the front edge of the baffle to clear the support bars. — Pull the baffle forward to disengage the rear edge from the location above the secondary air inlet holes. — Rotate the baffle and remove through the door opening. — Replace in reverse order. 4.5 It is import ...

  • Yeoman YMMB - page 22

    22 INSTALLATION INSTRUCTIONS 6. REMOVAL OF CLEANBURN CHAMBER 10 PR9045 Cap head screws 6.1 Remove the 4 M6 x 25 cap head screws using 5mm hexagonal key. 6.2 Lift chamber, rotate forward and remove from stove. 6.3 Check rope seal is in good condition (see Diagram 11). If necessary, replace using Yeoman 10 x 2 insulation tape (Yeoman Part No. 4953). ...

  • Yeoman YMMB - page 23

    23 COMMISSIONING 1.1 To commission: — Replace the baffle and log guard. — Check the door alignment and catch operation and adjust if required (see Maintenance & Servicing, Section 8 ). — Check the soundness of door seals, castings and joints. — Check seal of the stove to the wall. — Check the operation of the air controls. 1.2 Now car ...

  • Yeoman YMMB - page 24

    24 MAINTENANCE and SERVICING For a complete list of spare parts and accessories contact your Yeoman retailer or call 01392 474011 1. ANNUAL SERVICE 1.1 Before the start of the heating season strip, inspect and clean the appliance as detailed: — Allow appliance to cool. — Remove all internal parts; baffle, log guard, grate system and ashpan (s e ...

  • Yeoman YMMB - page 25

    25 2. REMOVAL OF THE LOG GUARD 2.1 To remove the log guard: — Lift log guard clear of the supporting brackets. — Rotate to clear the sides of the door opening. Do not use appliance without the log guard in position. 3. FITTING AND REMOVAL OF BAFFLE 3.1 See Installation Instructions , Section 4. 3.2 It is important to remove and clean the baffle ...

  • Yeoman YMMB - page 26

    26 PR8739 Glass rope seal B Black face — Place the glass into position in the door. — Place the glass clamp into position. — Re-fix with the clean fixing screws. — Tighten the screws evenly until the clamp holds the glass. 6.2 Fitting the door is the reverse of the process detailed in Installation Section 2, Page 20. The door may require so ...

  • Yeoman YMMB - page 27

    27 8. ADJUSTING DOOR CATCH & HINGES 8.1 To maintain the safe use of your appliance, you may need to adjust the door hinges to ensure the door closes safely and correctly. 8.2 To adjust the door hinge plate assembly : — Open door and lift free of hinge plate. — Lay the door face down on a soft, flat surface, to protect the paintwork and glas ...

  • Yeoman YMMB - page 28

    28 SPARE PARTS R ef . No. Product Code Dra wing No. (if different) Descr iption 1 CA7660 CANOPY 2 ME600486 MESH 3 STMB-MEC8609 MEC8609 AIR W ASH DUCT ASSEMBL Y 4 RA502311 CLAMP 5 M08200STUD M08 x 200 STUD 6 RA502305 BAFFLE 7 ME600493 CA TCH CLAMP 8 ME600521 LA TCH SCREW 9 RA502310 SECONDAR Y AIR CONTR OL 10 ME600395 SP A CER 11 MEC8617 ASH P AN ASS ...

  • Yeoman YMMB - page 29

    29 R ef . No. Product Code Dra wing No. (if different) Descr iption 1 CA7638 OUTER DOOR 2 - MEC600455 DOOR HANDLE STOP RING 3 MEC8619 DOOR HANDLE ASSEMBL Y 4 F A500025 T ORSION SPRING 5 F A9508 F A500016 SPRING 6.1 O/D X 0.61 DIA WIRE X 22.2 LG 6 CA7635 DOOR HANDLE CAM 7 MEC8636 HINGE PLA TE ASSEMBL Y 8 CE7732 DOOR GLASS 9 ME600392 AIR CONTROL HAND ...

  • Yeoman YMMB - page 30

    SERVICE RECORDS 30 1ST SERVICE Date of Service:........................................................................... Next Service Due:....................................................................... Signed:........................................................................................ Retailer's Stamp/HETAS Registration N ...

  • Yeoman YMMB - page 31

    31 ...

  • Yeoman YMMB - page 32

    Stovax Ltd, Falcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LF Tel: (01392) 474011 Fax: (01392) 219932 E-mail: info@stovax.com www.stovax.com A division of Stovax ...

Fabricante Yeoman Categoría Stove

Los documentos del dispositivo Yeoman YMMB que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Yeoman
- manuales de instrucciones YMMB
- hojas de producto Yeoman
- folletos informativos
- o etiquetas energéticas Yeoman YMMB
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Yeoman YMMB.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Yeoman YMMB, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Yeoman YMMB. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Yeoman YMMB.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Yeoman YMMB, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Yeoman YMMB. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Yeoman YMMB.

El manual de instrucciones completo de Yeoman debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Yeoman YMMB - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Yeoman YMMB, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Yeoman YMMB que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Yeoman YMMB - que deben facilitarnos los primeros pasos durante el uso de Yeoman YMMB
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Yeoman YMMB
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Yeoman YMMB en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Yeoman YMMB?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Yeoman YMMB, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Yeoman YMMB probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)