Manual de instrucciones Invacare 50EX

28 de páginas 0.34 mb
Descargar

Pasar a la página of 28

Summary
  • Invacare 50EX - page 1

    Venture 20EX, 20 PSIG Device Venture 50EX, 50 PSIG Device Venture Pack 211EX, 20 PSIG Shoulder Bag System w/M6 Cylinder Venture Pack 212EX, 20 PSIG Shoulder Bag System w/M9 Cylinder DEMAND OXYGEN DELIVERY DEVICE AND SYSTEM Owner's Operator and Maintenance Manual DEALER: THIS MANUAL MUST BE GIVEN TO THE USER OF THIS DEMAND OXYGEN DELIVERY DEVIC ...

  • Invacare 50EX - page 2

    2 VENTURE PART NO. 1093845 WARNING CAUTION Caution: Federal law restricts this device to sale by or on order of a physician, or any other practitioner licensed by the law of the State in which he practices to use or order the use of this device. WARNING DO NOT install, maintain or operate this equipment without first reading and understand ...

  • Invacare 50EX - page 3

    3 PART NO. 1093845 VENTURE SAFETY SUMMARY ............................................. 4 UNPACKING/HANDLING ..................................... 8 INTRODUCTION ................................................ 10 Invacare Venture Demand Oxygen Delivery Device ...................................................................................... ...

  • Invacare 50EX - page 4

    4 VENTURE PART NO. 1093845 SAFETY SUMMARY WARNING This device should ONLY be used under the supervision of a physician. Verify your oxygen flowrate with your physician when you begin using your Demand Oxygen Delivery System. If you have any questions about the oxygen delivery system or its use, call your Home Health Care Dealer or Service Repres ...

  • Invacare 50EX - page 5

    5 PART NO. 1093845 VENTURE SAFETY SUMMARY WARNING (CONTINUED) the supplier and/or physician should be contacted IMMEDIATELY. No adjustments should be made to the flowrate unless prescribed by a physician. DO NOT attempt to alter the switches in the battery compartment. These switches are preset by your Home Health Care Dealer and control the bre ...

  • Invacare 50EX - page 6

    6 VENTURE PART NO. 1093845 WARNING (CONTINUED) DO NOT wear the Demand Oxygen Delivery Device under any clothing. OTHER PRECAUTIONS: Never attempt to lubricate the oxygen delivery system. DO NOT insert any object (except suitable AC/DC Adapter) in external power jack of Demand Oxygen Delivery Device. This may cause an electrical shock which could ...

  • Invacare 50EX - page 7

    7 PART NO. 1093845 VENTURE WARNING (CONTINUED) DO NOT use a humidifier with the Demand Oxygen Delivery Device. DO NOT expose the Demand Oxygen Delivery Device or system to water or any other liquids. RADIO FREQUENCY INTERFERENCE Most electronic equipment is influenced by Radio Frequency Interference (RFI). CAUTION should be exercised with regard ...

  • Invacare 50EX - page 8

    8 VENTURE PART NO. 1093845 UNPACKING / HANDLING UNPACKING 1 . Check for any obvious damage to the carton or its contents. (If damage is evident, notify your local Invacare Home Health Care Dealer/Carrier.) 2 . Remove all the loose packing from the carton. 3 . Carefully remove all the components from the carton. The following is a listing of item ...

  • Invacare 50EX - page 9

    9 PART NO. 1093845 VENTURE HANDLING PROCEDURES NOTE: Unless the Venture Demand Oxygen Delivery Device is to be used immediately, retain boxes, containers and packing materials for use in returning or storing the equipment until usage is required. INSPECTION 1 . Examine exterior of the equipment for nicks, dents, scratches or other damages. Inspe ...

  • Invacare 50EX - page 10

    10 VENTURE PART NO. 1093845 INVACARE VENTURE DEMAND OXYGEN DELIVERY DEVICE Ordinary oxygen supply units deliver oxygen continuously. The normal breathing pattern is to inhale about one-third of the time, and exhale two-thirds of the time. This means that continuous flow units may be inefficient during user exhalation. In contrast, the Venture De ...

  • Invacare 50EX - page 11

    11 PART NO. 1093845 VENTURE FEATURES VENTURE DEMAND OXYGEN DELIVERY DEVICE COMPONENTS AND DEFINITION OF TERMS (FIGURE 1) ON/OFF Buttons - Determines flow selection method. The ON button turns Power ON for normal pulse operation ( ) a n d the OFF button disengages the electronics for continuous flow operation ( ) . NOTE: The OFF button does NOT s ...

  • Invacare 50EX - page 12

    12 VENTURE PART NO. 1093845 Oxygen INLET Fitting FIGURE 1 - VENTURE DODD FEATURES FEATURES ç Oxygen OUTLET Fitting Pulse LED (GREEN) Attention LED (YELLOW) Battery LED (RED) Low O 2 LED (GREEN) ê ê êê è External Power Input Jack ON(Pulse ModeOperation) OFF (Continuous Mode Operation) é NOTE: Battery Compartment located on bottom back of V ...

  • Invacare 50EX - page 13

    13 PART NO. 1093845 VENTURE FEATURES VENTURE DODD SYSTEM COMPONENTS AND DEFINITION OF TERMS (FIGURE 2) Cylinder - Lightweight aluminum cylinder provided. Regulator - Provides flowrate control of oxygen delivery with compressed gas cylinders. DISS Fitting - Connection point for direct connect to oxygen source. Barb Fitting - Connection point for ...

  • Invacare 50EX - page 14

    14 VENTURE PART NO. 1093845 SPECIFICATIONS OPERATING VOLTAGES EXTERNAL AC/DC POWER Output: 12 + 3 VDC, 100 mA ADAPTER: Connector: 5.5mm OD x 2.1mm ID x 12.0mm No. 2 Connector ALARMS Low Battery (Two [2] levels) Cannula Disconnect (Breath not sensed) Device Malfunction Low / No Gas Indicator INDICATORS/SYMBOLS: O 2 LED: Pulse Delivery LED: Cannul ...

  • Invacare 50EX - page 15

    15 PART NO. 1093845 VENTURE SPECIFICATIONS ENVIRONMENTAL Operating Temperature: 40 ° to 104 ° F (5 ° to 40 ° C) Storage Temperature: - 40 ° to 158 ° F (-40 ° to 70 ° C) DEVICE DIMENSIONS Length: 5.4 -i nches (13.7cm) Thickness: 1.6-inches (4.0cm) Width: 3.6-inches (9.1cm) Weight: 16.0 ozs. (454gm) ...

  • Invacare 50EX - page 16

    16 VENTURE PART NO. 1093845 THE USE OF OXYGEN The type of oxygen administrating equipment to be used, as well as the flowrate and time of usage, must be prescribed by a physician. Your physician should verify your Venture DODD flowrate prescription. WARNING If at anytime the attendant or the end user concludes that an insufficient amount of oxyg ...

  • Invacare 50EX - page 17

    17 PART NO. 1093845 VENTURE OPERATION 3 . If using an oxygen cylinder, check that the regulator is properly attached before opening the cylinder valve. 4 . Connect the Venture DODD to the regulator by performing one (1) of the following: A. If using an Oxygen Cylinder and Regulator: On a 20 psig regulator, connect the tubing (supplied with the V ...

  • Invacare 50EX - page 18

    18 VENTURE PART NO. 1093845 6 . Set the prescribed flow rate on the oxygen source by performing one (1) of the following: A. If using an Oxygen Cylinder and Regulator: OPEN cylinder valve and adjust regulator to prescribed flow rate. B. If using a Liquid Oxygen Reservoir: Set flow control knob on reservoir to prescribed flowrate. 7 . Press the O ...

  • Invacare 50EX - page 19

    19 PART NO. 1093845 VENTURE NOTE: Whenever the pulse mode is used, the battery is monitored. If the SECOND BATT. LED illuminates, either replace the battery or switch to continuous mode if oxygen supply is adequate. When in continuous mode, the battery is NOT used. NOTE: When in the continuous flow mode, the oxygen supply will be used considerab ...

  • Invacare 50EX - page 20

    20 VENTURE PART NO. 1093845 PROLONGING THE LIFE OF YOUR BATTERY The Venture DODD battery is powered by a single D-cell battery. The Alkaline battery type is recommended for longest life. NOTE: The Alkaline battery should last for approximately 80 hours with normal use, but will last even longer if you follow this procedure: 1 . Use the battery t ...

  • Invacare 50EX - page 21

    21 PART NO. 1093845 VENTURE CARE OF YOUR VENTURE DEMAND OXYGEN DELIVERY DEVICE AND SYSTEM CLEANING THE OUTER CASE WARNING DO NOT submerge in water to clean. DO NOT open outer case. If outer case is removed by anyone EXCEPT an Invacare Dealer the warranty will be voided. CAUTION Use no oil. Never apply waxes, polishes, or other similar compounds ...

  • Invacare 50EX - page 22

    22 VENTURE PART NO. 1093845 M6 Aluminum Cylinder, 164L Capacity M9 Aluminum Cylinder, 248L Capacity Piston Regulator, 0.5-6 L/Min., 20 psig, CGA 870 Shoulder Bag, Hunter Green (Dual size for Cylinder diameters of 3 and 4-inches) Venture Device Pouch 12-inch Connection Tubing Barb Fitting, 1/4-28 UNF 7-Foot (2.1m) Nasal Cannula AC/DC Adapter Vent ...

  • Invacare 50EX - page 23

    23 PART NO. 1093845 VENTURE TROUBLESHOOTING This is normal operation. Turn unit OFF, check cylinder pressure is above refill limit (500 psig) and post valve is open, check regulator is set to correct flowrate. If problem still exists, call your Home Health Care Dealer or Service Representative IMMEDIATELY and go to continuous mode if oxygen supp ...

  • Invacare 50EX - page 24

    24 VENTURE PART NO. 1093845 TROUBLESHOOTING PROBLEM PO SSIBLE CAUSE SOLUTIONS Oxygen NOT being delivered. Oxygen supply exhausted. Oxygen supply NOT turned ON. Cannula kinked or crushed. Regulator knob NOT turned ON. Internal Problem. Connector jack not fully inserted into unit. Wall outlet bad or no power. Check contents gauge on oxygen source. ...

  • Invacare 50EX - page 25

    25 PART NO. 1093845 VENTURE TROUBLESHOOTING PROBLEM PO SSIBLE CAUSE SOLUTIONS External input will not power device (Cont.). "Low" battery light comes on too soon after battery replacement. External power adapter plug does not go into jack in unit. Unit pulses at times other than inhalation. Continuous flow out of cannula when in pulse ...

  • Invacare 50EX - page 26

    26 VENTURE PART NO. 1093845 OXYGEN CONSERVED AND BATTERY USE TIME BASED ON BREATH RATE i.e. 77% Oxygen conservation over Continuous Flow achieved with Venture DODD in Variable Breath Mode @ 20 BPM Rate. Oxygen supply lasts 4.3-times longer. Venture DODD responds to individual breath rates. Therefore, use times stated are only approximates. Actua ...

  • Invacare 50EX - page 27

    27 PART NO. 1093845 VENTURE PLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4, 1975. This warranty is extended only to the original purchaser/user of our products. This warranty gives you specific legal rights and you may also have other legal rights which vary from state ...

  • Invacare 50EX - page 28

    CORPORATIONS CONTROL, AND SUCH EVALUATION WILL BE SOLELY DETERMINED BY INVACARE. THE WARRANTY SHALL NOT APPLY TO PROBLEMS ARISING FROM NORMAL WEAR OR FAILURE TO ADHERE TO THE FOLLOWING INSTRUCTIONS. THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IN LIEU OF ANY OTHER WARRANTIES WHATSOEVER, WHETHER EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRAN ...

Fabricante Invacare Categoría Oxygen Equipment

Los documentos del dispositivo Invacare 50EX que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Invacare
- manuales de instrucciones 50EX
- hojas de producto Invacare
- folletos informativos
- o etiquetas energéticas Invacare 50EX
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Invacare 50EX.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Invacare 50EX, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Invacare 50EX. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Invacare 50EX.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Invacare 50EX, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Invacare 50EX. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Invacare 50EX.

El manual de instrucciones completo de Invacare debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Invacare 50EX - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Invacare 50EX, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Invacare 50EX que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Invacare 50EX - que deben facilitarnos los primeros pasos durante el uso de Invacare 50EX
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Invacare 50EX
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Invacare 50EX en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Invacare 50EX?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Invacare 50EX, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Invacare 50EX probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen