GE 7500 SERIES - page 1
49-7419-1 11-01 JR Air Con di t i o n ers Safety Instr uctions . . . . . . . . . . .2 Operating Instr uctions Controls—Dip Switches . . . . . .3–5 Controls—T erminal Connections . . . . . . . . . . . . . .6, 7 On/Off Switch . . . . . . . . . . . . . . .8 V entilation Control . . . . . . . . . . .8 Care and Cleaning Air Filters . . . . . . . . ...
-
GE 7500 SERIES - page 2
Customer Service T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions IMPORT ANT SAFETY INFORMA TION. READ ALL INSTRUCTIONS BEFORE USING. W ARNING! For your safety , the information in this manual must be followed to minimize the risk of fire, electric shock, or to prevent property damage, personal injury , or loss of ...
-
GE 7500 SERIES - page 3
Safety Instructions Operating Instructions Care and Cleaning T roubleshooting T ips Customer Service 3 Controls–dip switches. GEAppliances.com The dip switch controls are located behind the front case panel, through an opening on the front of the unit. T o access the dip switches, remove the front case panel by removing the filter , taking out th ...
-
GE 7500 SERIES - page 4
Consumer Support T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions 4 Controls–dip switches. Freeze Sentinel (Requires room air sensor kit–RA VRMS) When this switch is enabled (UP) , it turns OFF the freeze sentinel protection feature. With the switch disabled (DOWN) , the freeze sentinel is activated which auto ...
-
GE 7500 SERIES - page 5
5 Safety Instructions Operating Instructions Care and Cleaning T roubleshooting T ips Consumer Support GEAppliances.com T emperature Limiting (Requires room air sensor kit–RA VRMS) T emperature limiting can reduce energy costs by limiting the lowest temperature that can be set for cooling and the highest temperature that can be set for heating. T ...
-
GE 7500 SERIES - page 6
6 Consumer Support T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions Controls—terminal connections. Controls–T erminal Connections The terminal connections are located behind the front case panel through an opening on the front of the unit. T o access the terminal connections, remove the front panel by removing ...
-
GE 7500 SERIES - page 7
Remote Thermostat The unit will be controlled by a remote thermostat. IMPORT ANT : The Zoneline thermostat connections provide 24V AC only . If using a digital/electronic wall thermostat, you must set it to the 24V AC setting. See the Installation Instructions for the wall thermostat. CAUTION: Damage to a wall thermostat or to the Zoneline electron ...
-
GE 7500 SERIES - page 8
8 Consumer Support T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions Other features of your Zoneline. About Heat Pumps (on some models) Heat pumps can reduce operating costs by exchanging heat from the outside air—even when the outside temperature is below freezing— and releasing that heat indoors. T o get the ...
-
GE 7500 SERIES - page 9
Indoor/Outdoor Coils The exhaust coils on the Zoneline should be checked regularly . If they are clogged with dirt or soot, they may be professionally steam cleaned by your GE service center . Y ou will need to remove the unit from the case to inspect the coils because the dirt build-up occurs on the exhaust side. 9 Safety Instructions Operating In ...
-
GE 7500 SERIES - page 10
BEFORE YOU BEGIN Installation Zoneline Air Instructions Conditioners Read these instr uctions completely and carefully . • IMPORT ANT – Save these instructions for local inspector’ s use. • IMPORT ANT – Obser ve all governing codes and ordinances. • Note to Installer – Be sure to leave these instructions with the owner . • Note to O ...
-
GE 7500 SERIES - page 11
11 Installation Instructions ELECTRICAL REQUIREMENTS 230/208 VOL T ELECTRICAL SUPPL Y T andem 15 Amp 230/208 volt receptacle configuration Perpendicular 20 Amp Large T andem 30 Amp • Use ONLY the wiring size recommended for single outlet branch circuit. • Use ONLY the the type and size fuse or HACR circuit breaker indicated on the unit’ s rat ...
-
GE 7500 SERIES - page 12
REMOVE JUNCTION BOX COVER • Remove the junction box cover by taking out the front two screws. 1 Junction box Installation Instructions 12 DIRECT CONNECT APPLICA TIONS W ARNING: FOR 265 VOL T DIRECT CONNECT APPLICA TIONS ONL Y Connection of a 265V AC product to a branch circuit MUST be done by direct connection in accordance with the National Elec ...
-
GE 7500 SERIES - page 13
13 Installation Instructions DIRECT CONNECT APPLICA TIONS MAKE WIRE LEAD CONNECTIONS INSIDE THE JUNCTION BOX 1. Make all wire connections by using appropriate UL-listed electrical connectors and techniques. 2. Be sure that all wire leads are inside the junction box and not pinched between the box and the unit. The green insulated ground wire from t ...
-
GE 7500 SERIES - page 14
Installation Instructions 14 ZONELINE COMPONENTS Case Zoneline unit Front Case Panel REQUIRED ACCESSORIES (Check the “Essential Elements” label on the unit.) Architectural Louver RA V AL1 W all Plenum RA VWP6 - 6 ″ D x 19 3 ⁄ 4 ″ W x 32 ″ H RA VWP8 - 8 ″ D x 19 3 ⁄ 4 ″ W x 32 ″ H RA VWP12 - 12 ″ D x 19 3 ⁄ 4 ″ W x 32 ″ H ...
-
GE 7500 SERIES - page 15
Installation Instructions 15 TYPICAL UTILITY CLOSET AND DIMENSIONS (FOR REFERENCE ONL Y) ...
-
GE 7500 SERIES - page 16
Installation Instructions 16 UTILITY CLOSET CONNECTION LOCA TIONS IMPOR T ANT : Plan and locate plenum, wall plug, drain and thermostat carefully to avoid interference. Hard-to-reach locations will make installation and service difficult! Reference Dimensions A Thermostat cable: 9 1 ⁄ 2 ′ long B Power cord: 60 ″ long C Case width and depth: 2 ...
-
GE 7500 SERIES - page 17
Installation Instructions 17 RETURN AIR GRILLE INST ALLA TION OPTIONS The room return air grille may be installed toward the front or either side of the unit. Improper return air arrangements will cause per formance problems. There are three indoor Return Air Grille Installation options. Choose the option that best suits your installation requireme ...
-
GE 7500 SERIES - page 18
BUILD AND INST ALL THE ZONELINE BASE PLA TFORM 1. Construct a 23 1 ⁄ 4 ″ min. x 23 1 ⁄ 4 ″ min. square platform. NOTE: The platform must have a load-bearing capacity of 175 lbs. minimum. 1 Installation Instructions 18 W ALL PLENUM AND ARCHITECTURAL LOUVER INST ALLA TION • Install the appr opriate wall plenum through the exterior wall in a ...
-
GE 7500 SERIES - page 19
INST ALL THE DRAIN An exter nal or an inter nal drain must be attached to the drain connector . Exter nal Drain Attach a 90° PVC elbow to the unit’ s female 3/4 ″ NPT drain connector . Use the other end of the elbow to run a 3/4 ″ Sch.40 PVC pipe through the knockout holes of both the wall plenum and the architectural louver to the outside. ...
-
GE 7500 SERIES - page 20
INST ALL AND CONNECT THE CASE 1. Remove the front case panel and pull the unit out of the case. Place the empty case onto the platform in the closet with the outdoor side facing the wall plenum opening. Align the case to the plenum opening and attach with six screws. 2. Adjust all four leveling legs until the case is level. 3. Using field-supplied ...
-
GE 7500 SERIES - page 21
...
-
GE 7500 SERIES - page 22
Installation Instructions SER VICING W ARNING: Before servicing, switch power off at the ser vice panel and lock the area to prevent power from being switched on accidentally . When the area cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. NOTE: W e strongly recommend that any ser vicing be per form ...
-
GE 7500 SERIES - page 23
Safety Instructions Operating Instructions Care and Cleaning T roubleshooting T ips Consumer Support Before Y ou Call For Service… GEAppliances.com T roubleshooting T ips Problem Possible Causes What T o Do Zoneline does The unit is • Make sure the Zoneline plug is pushed completely not start unplugged. into the outlet. The fuse is blown/circui ...
-
GE 7500 SERIES - page 24
Consumer Support T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions 24 Normal Operating Sounds Y ou may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency . Y ou may hear re ...
-
GE 7500 SERIES - page 25
25 General Electric Company W ar ranty Registration Depar tment P .O. Box 32150 Louisville, KY 40232-2150 Please place in envelope and mail to: ✁ Cut here ...
-
GE 7500 SERIES - page 26
26 Consumer Pr oduct Ownership Registration Important Mail T oday! General Electric Company Louisville, Kentucky GEAppliances.com First Name Mr . ■ ■ Ms. ■ ■ Mrs. ■ ■ Miss ■ ■ Street Address City State Date Placed In Use Month Day Y ear Zip Code Apt. # Last Name Phone Number _ _ Consumer Pr oduct Ownership Registration Dear Customer ...
-
GE 7500 SERIES - page 27
Safety Instructions Operating Instructions Care and Cleaning T roubleshooting T ips Consumer Support 27 V ertical Zoneline W arranty . For The Period Of: GE Will Replace: One Y ear Any part of the Zoneline which fails due to a defect in materials or workmanship. During this From the date of the full one-year warranty , GE will also provide, free of ...
-
GE 7500 SERIES - page 28
Printed in China Consumer Support. GE Appliances W ebsite GEAppliances.com Have a question or need assistance with your appliance? T r y the GE Appliances W ebsite 24 hours a day , any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals, order parts, catalogs, or even schedule service on-line. Y ou ca ...
¿Tienes una pregunta acerca de GE 7500 SERIES?
Utiliza el formulario que se encuentra abajo
Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con GE 7500 SERIES, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con GE 7500 SERIES probablemente compartirá una forma de solucionarlo.