    GAS-FIRED VENTED GAS-FIRED VENTED GAS-FIRED VENTED GAS-FIRED VENTED GAS-FIRED VENTED W W W W W ALL FURNACE ALL FURNACE ALL FURNACE ALL FURNACE ALL FURNACE INST ALLA TION AND OPERA TING INSTRUCTIONS P/N 84502 / REV . 1 1/04 NA TURAL W251F , W351F , W501F L. P . W252F , W352F , W502F G A S W255F , W355F , W505F GA S W256F , W356F , W506F W ARNING: Op ...

  • Louisville Tin and Stove W506 - page 2

    READ CAREFULL Y BEFORE INST ALLING UNIT These installation instructions are a general guide, and do not supersede applicable local codes and ordinances. Before planning or making the installation, be sure it complies with all phases of the local heating codes. Or , in the absence of local codes, with the latest edition of the National Fuel Gas Code ...

  • Louisville Tin and Stove W506 - page 3

    1” 11” 2” SAFETY RULES A) The wall furnace should be located near the center of the house for best heat distribution. B) Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies. C) Children and adults should be alerted to the hazards of high surface temperature and should stay away to avo ...

  • Louisville Tin and Stove W506 - page 4

    COMBUSTION AND VENTILA TION AIR When installed, this gas appliance must be provided with fresh air for combustion, ventilation, and dilution of hot flue gases. The minimum required volume of the area where the appliance is installed should be 50 cubic feet per 1,000 btu/hr . If installed in an area of the home that is considered an unconfined space ...

  • Louisville Tin and Stove W506 - page 5

    VENTING This appliance must be properly connected to a venting system. Consult local ordinances governing venting. Install only UL listed type BW 4” oval gas vent. When the vent enters the attic, a listed type B-1 round flue pipe may be used. See Figure 2, Page 7. V ent pipe must connect to the wall furnace header plate with a “B” vent base p ...

  • Louisville Tin and Stove W506 - page 6

    ROUGH-IN INSTRUCTIONS NOTE: Maximum wall thickness for a dual wall (W501, W502, W505, W506) installation is 5-3/8”. STEP 1. Attach the base plate (purchased with the vent pipe) to the header plate using two No. 8 sheet-metal screws through the pre-punched holes. The heater may not vent properly without a base plate to anchor and seal the vent sys ...

  • Louisville Tin and Stove W506 - page 7

    ROUGH-IN INSTRUCTIONS NOTE: For proper combustion, make sure units are level, front to back and side to side. FIGURE 5A - DR Y W ALL FIGURE 5B - PLASTER W ALL FIGURE 1 ROUGH-IN DIMENSIONS Dry-W all B-W T ype V ent Front Panel Screw Plaster Ground Plaster B-W T ype V ent Screw Front Panel Plaster Ground STEP 4. Remove double ceiling plate between st ...

  • Louisville Tin and Stove W506 - page 8

    B-W VENT FIGURE 3 Casing “Z Bracket Front Panel Front Panel Door FIGURE 5C INST ALLA TION STEP 6. T o place furnace into position, grasp furnace and lift so furnace flue vent and header plate vent opening engage. Do not use burner or gas control to lift heater . Lift furnace upward and swing bottom into wall opening until legs rest on floor plate ...

  • Louisville Tin and Stove W506 - page 9

    CAUTION: Label all wires prior to disconnection when servicing controls. W iring errors can cause improper and dangerous operation. V erify proper operation after servicing. WIRING INSTRUCTIONS – GRA VITY W ALL FURNACE W ARNING: Failure to locate the thermostat properly or to wire the furnace correctly may result in continuous operation, control ...

  • Louisville Tin and Stove W506 - page 10

    A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these in- structions exactly . B . BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor . WHA T TO DO IF YOU SMELL GAS: • Do not try to light any ...

  • Louisville Tin and Stove W506 - page 11

    LIGHTING INSTRUCTIONS MODEL: W251F , W252F / W351F , W352F / W501F , W502F FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may r esult causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, fo ...

  • Louisville Tin and Stove W506 - page 12

    PILOT ADJUSTMENT Locate the pilot adjustment screw on the valve. The pilot flame should surround at least the top 3/8” of the powerpile (pilot generator) or thermocouple (see below). The pilot is unregulated so it will be operating at inlet line pressure (Max. 7” w .c. for natural gas and 1 1” w .c. for propane). T o decrease the pilot flame, ...

  • Louisville Tin and Stove W506 - page 13

    Page 13 MODEL WFF81-C OPTIONAL F AN KIT INST ALL A TION INSTR UCTIONS NO TE: This fan kit is to be installed after installation of wall furnace and with the wall furnace front panel in place. STEP 1 . This appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the latest editi ...

  • Louisville Tin and Stove W506 - page 14

    Ground WHITE BLACK L2 White 1 15 V AC L1 Black 1 15 V AC BLACK F AN SWITCH BLACK BLACK BLACK MOTO R WHITE GREEN GROUND WIRE L2 White L1 Black 1 15 V AC 60 HZ - Less than 12 Amps. If any of the original wire as supplied with this appliance must be replaced, it must be replaced with type thermoplastic 105 degree C wire or its equivalent. WFF81-C WIRI ...

  • Louisville Tin and Stove W506 - page 15

    TROUBLE SHOOTING CHAR T for qualified serviceman - MAIN BURNER SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION Flame too lar ge 1. Defective operator section of gas valve. 1. Replace complete valve. 2. Burner orifice too large. 2. Check with local gas company for proper orifice size and replace. 3. If installed above 2,000 ft. 3. Refer to orifice chart, ...

  • Louisville Tin and Stove W506 - page 16

    SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION Burner won’t 1. Pilot flame too lar ge or too small. 1. Re-adjust pilot flame using adjustment on turn on combination control valve. 2. Dirt in pilot orifice. 2. Clean pilot orifice with air or solvent, do not ream. 3. Defective automatic pilot section in 3. Replace entire combination control valve. combi ...

  • Louisville Tin and Stove W506 - page 17

    SINGLE W ALL FURNACE Model Numbers Nat. L.P . W251F W252F W351F W352F W255F W256F W355F W356F DUAL W ALL FURNACE Model Numbers Nat. L.P . W501F W502F W505F W506F NOTICE: When ordering any component in the Burner Assembly , specify either Honeywell or Robertshaw components. REV . 08/02 Page 17 Prices and specifications subject to change without noti ...

  • Louisville Tin and Stove W506 - page 18

    HOW TO PROPERL Y ORDER P A R TS: In addition to part description and part number, please give model number , serial number , and type of gas used. This information can be found on the rating plate that is attached to heater . Mr . Contractor , we only sell parts through our wholesalers, but the prices listed are for your convenience. For prompt par ...

  • Louisville Tin and Stove W506 - page 19

    IMPOR T ANT SAFETY BULLETIN ON YOUR GAS CONTROL AND PILOT LIGHT SYSTEM FOR HEA TING EQUIPMENT WHA T YOU DON’T KNOW CAN HURT YOU. Y our pilot light system has been designed for safe and reliable operation. Although safety mechanisms are built-in, the potential for hazard exists. This information is intended to help you avoid these hazards. YOUR GA ...

  • Louisville Tin and Stove W506 - page 20

    T ABLE A W arranty for gas appliance heat exchangers only . Product W arranty Period Cozy Gas Fired Floor Furnace 10 Y ears Cozy Gas Fired W all Furnace 10 Y ears Cozy Gas Fired V ented Console Heater 10 Y ears Cozy Gas Fired Direct V ent Heater 10 Y ears Cozy Gas Fired Counterflow Furnace 10 Y ears Cozy Gas Fired Counterflow Direct V ent Furnace 1 ...

Fabricante Louisville Tin and Stove Categoría Furnace

Los documentos del dispositivo Louisville Tin and Stove W506 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Louisville Tin and Stove
- manuales de instrucciones W506
- hojas de producto Louisville Tin and Stove
- folletos informativos
- o etiquetas energéticas Louisville Tin and Stove W506
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Louisville Tin and Stove W506.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Louisville Tin and Stove W506, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Louisville Tin and Stove W506. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Louisville Tin and Stove W506.

El manual de instrucciones del dispositivo Louisville Tin and Stove W506, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Louisville Tin and Stove W506. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Louisville Tin and Stove W506.

El manual de instrucciones completo de Louisville Tin and Stove debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Louisville Tin and Stove W506 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Louisville Tin and Stove W506, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Louisville Tin and Stove W506 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Louisville Tin and Stove W506 - que deben facilitarnos los primeros pasos durante el uso de Louisville Tin and Stove W506
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Louisville Tin and Stove W506
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Louisville Tin and Stove W506 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Louisville Tin and Stove W506?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Louisville Tin and Stove W506, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Louisville Tin and Stove W506 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)