    1 ENVIROFIRE PELLET STOVE EF-3 BAYi OWNERS TECHNICAL MANUAL SHERWOOD INDUSTRIES LTD. 6782 OLDFIELD ROAD VICTORIA, BRITISH COLUMBIA V8M-2A3 MODELS FS, FPI and BIH ...

  • Sherwood EF-3 BAYI - page 2

    ENVIROFIRE INSTALLATION MANUAL TABLE OF CONTENTS INTRODUCTION Important Sa fety Data ........................................................... 3 Pellet Q uality ........................................................................ 4 Warnings and Re commendatio ns......................................... 5 Automatic Safe ty Feat ures .......... ...

  • Sherwood EF-3 BAYI - page 3

    IMPORTANT SAFETY DATA Please read this entire manual befo re installation and use of this pellet fuel bu rning room heater. Failure to follo w these instructions could result in prop erty damage, bodily injury or even death. CAUTION: DO NOT CONNECT OT ANY AIR DISTRIBUTION DUCT OR SYSTEM; DO NOT BURN GARBAGE OR FLAMA BLE FLUIDS SUCH AS GASOLINE, NAP ...

  • Sherwood EF-3 BAYI - page 4

    PELLET QUALITY IS IMPORTANT, PLEASE READ THE FOLLOWING PAGE Your pellet stove has been designed to burn wood pellets only. Since there are many manufacturers of wood pellets it is important to select pellets that are free of dirt or any impurities. The Pellet Fuel Industries (P.F.I.) has established standards for wood pellet manufactures. We recomm ...

  • Sherwood EF-3 BAYI - page 5

    WARNINGS AND RECOMMENDATIONS A. Do not abuse the glass by striking or slamming the door shut. B. Do not attempt to operate the stove with broken glass. C. Do not attempt to open the door and clean the glass while the unit is in operation. If you must clean the glass, use a soft cotton cloth and mild window cleaner. D. Do not use abrasive cleaners t ...

  • Sherwood EF-3 BAYI - page 6

    HOW TO START AND OPERATE YOUR PELLET APPLIANCE 1. Check and fill hopper with pellets. 2. Switch on power by pushing the start up switch once only. CONVECTION BLOWER SPEED CONTROL 3. Turn the Dial A Fire knob to the 12 o’clock position. (Lower grade pellets may need a higher setting on the feed rate). NOTE: unit will take longer to light if the ho ...

  • Sherwood EF-3 BAYI - page 7

    SLIDER/DAMPER INSTALLATION /OPERATION INSTRUCTIONS This is used to regulate the airflow through the pellet stove. INSTALLATION 1. Remove the slider rod (short rod with knob and nuts) and the two nuts from their package and open the left side panel. 2. Remove the knob and outer nut from the knob. Push the rod through the hole in the slider. Place th ...

  • Sherwood EF-3 BAYI - page 8

    AREAS FOR ROUTINE INSPECTION The following should be inspected perio dically to ensure that the a ppliance is operating at it s optimum and giving you excellent heat value: 2-3 DAYS/WEEKLY SEASONALLY or 2 TONS OF FUEL Burn Pot and Liner Exhaust Vent and Fresh Air Intake Tube Ash Pan Blower Mechanisms Inside Firebox Heat exchanger tubes Behind Fireb ...

  • Sherwood EF-3 BAYI - page 9

    DOOR GLASS (It is recommended that your dealer replace the glass if broken.) The door glass is made of 5 mm thick, high tempe rature PYROCERAMIC The center panel is 229 mm x 33 0 mm. To replace the glass, unscrew and remove the four glas s retain ers. Remove the glass and any broken pieces. High temperature fiberglass tape shoul d be used arou nd t ...

  • Sherwood EF-3 BAYI - page 10

    ELECTRICAL COMPONENT FUNCTIONS The following is a list of electrical components and their functi ons on the ENVIROFIRE EF-IIIi Bay pellet stove. 1. CONVECTION FAN CONTROL LER This controller is responsib le for varying the speed of the convection blower. The stove does have a fan control over-ride. Should the convection blower be set on low and dia ...

  • Sherwood EF-3 BAYI - page 11

    11. 160 ° F (71 ° C) TEMPERATURE SENSOR When this sensor (located on the left side firewall) reache s 160 ° F (71 ° C), the convection blow er will go to high, cooling the unit. 12. 140 ° F (60 ° C) N/O TEMPERATURE SENSOR (SHUT-DOWN SENSOR) This sensor (mounted on the exhaust bl ower housing) has t wo functions: - Should the fire go out, this ...

  • Sherwood EF-3 BAYI - page 12

    DECIDING WHERE TO LOCATE YOUR PELLET APPLIANCE 1. Check clearance s to combustibles. 2. Do not obtain combustion air from an attic, gara ge or any unventilated space. Combustion air may be obtained from a ventilated crawlspace. 3. Do not install the stove in a bedroom. 4. You can vent the stove through an exterior wall behind the unit or connect it ...

  • Sherwood EF-3 BAYI - page 13

    REMOVING YOUR NEW STOVE FROM IT’S PALLET To remove your new stove from its pallet , open the left and right side panels. There are two wood screws that are holding the bottom of the stove to the pallet. Remove the screws. Close the sid e panels. See PAGE 18 how to install the pedestal. INSERT MODEL FREE STAND MODEL REMOVE SCREW HERE FIREPLACE DIM ...

  • Sherwood EF-3 BAYI - page 14

    MASONRY FIREPLACE INSERT INSTALLATION, MODEL FPI The Fireplace Insert model includes surround f ace plates and a pedestal. When installing this unit, ensure that the pedestal is removed from its box and installed on the bottom of the unit. (Surround assembly instructions are in this manual). CLEARANCE TO COMBUSTIBLES: Side wall .................... ...

  • Sherwood EF-3 BAYI - page 15

    ASSEMBLING THE FACE PLATE FOR THE FPI AND BIH MODELS 1. To attach the pedestal, place the unit on its back, making sure not to damage the wiring, then bolt the pedestal onto the unit. Back off the screws on the base, install the pedestal over the screws. Lock in place using t he keyholes, tighten the screws. 2. Assemble the three faceplates to the ...

  • Sherwood EF-3 BAYI - page 16

    RECOMMENDED FRAMING FOR BUILT IN HEATER When installing model BIH it is recommended that you use the dimensions shown in the diagram below. These type of clearances will make it easy and readily accessible for service. BUILT IN HEATER CLEARANCES TO COMBUSTIBLES This unit includes a 3” (75 mm) pedestal and surrounding faceplates. The part of the u ...

  • Sherwood EF-3 BAYI - page 17

    FREESTANDING INSTALLATION, MODELS FS CLEARANCES TO COMBUSTIBLES (FREESTANDING) - Side wall to unit A- 6 INCHES (150 mm) - Back wall to unit B- 1 INCH (25 mm) - Corner to unit C- 1 INCH (25 mm) - Mantle (Hearth Mount) 8 INCHES ( - Combustible flooring underneath the unit and extending 6 INCHES (150 mm) to the sides and front must be protected by a n ...

  • Sherwood EF-3 BAYI - page 18

    MODEL FS (FREESTANDING) INSTALLATION PEDESTAL INSTALLATION : Model FS comes with a p edestal that has to be attached prior to installation: - Remove the pedestal from the box - Remove the ENVIROFIRE heater form the box. - Place the unit on its back, making sure not to damage the wiring. - Back off the screws on the base, install the pedestal over t ...

  • Sherwood EF-3 BAYI - page 19

    HORIZONTAL EXHAUST THROUGH THE WALL 1. NOTE: Use only listed type “PL” or “L” pellet venting prod ucts . Failure to use listed components may cause damage or personal injury or death. 2. Choose a location for your stove that meets the requirements stated in this manual and allows installation with the least amount of interference to house f ...

  • Sherwood EF-3 BAYI - page 20

    THROUGH WALL INSTALLATION 1” 20 ...

  • Sherwood EF-3 BAYI - page 21

    FREESTANDING INSIDE VERTICAL INSTALLATION 1. Choose a stove location that is ideal. See the section Deciding Where to Locate Your Pellet Appliance. 2. Place a non-combustible hearth pad where necessary. 3. Place the unit on the hearth pad and space it in a manner so when the pellet vent is installed vertically, it will be 3” (76 mm) away from a c ...

  • Sherwood EF-3 BAYI - page 22

    FREESTANDING OUTSIDE VERTICAL INSTALLATION To accomplish the above titled installation, follow steps 1 through 8 in the previous section and then finish it by performing the following. 9. Install a tee with clean out on the outside of the house. 10. Install PL vent upward from the tee. Make sure that you install support brackets t o keep the vent s ...

  • Sherwood EF-3 BAYI - page 23

    MOBILE HOME INSTALLATION - Secure the heater to the floor using the two bolt holes supplied in the pedestal. - CAUTION: THE STUCTURAL INT EGRITY OF THE MANUFACTURED HOME FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED. - Ensure the unit is electrically grounded to the chassis of your home (permanently). - Do not install in a room people sleep in. ...

  • Sherwood EF-3 BAYI - page 24

    TROUBLESHOOTING DO NOT: - Hold the start-up switch down, this is a momentary contact switch and can be damaged if held down too long. - Service the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly. Only qualified technicians should deal with possible internal electrical failures. - Remo ...

  • Sherwood EF-3 BAYI - page 25

    4. The convection blower will not function normally - Check all the connections between the contro ller, switch, and the convection blower against the wiring diagram. - If the convection motor will not run, apply 230V AC to the motor directly. If the m otor runs, replace the fan controller. If the motor does not run, the convection blower has faile ...

  • Sherwood EF-3 BAYI - page 26

    placing a jumper across the pins. If the auger now cycles very quickly, test the dial-a-fire potentiometer. If the auger did not cycle then replace the timing control module. - To test the dial-a-fire potentiometer. The potentiometer should have a range of 68K to approximately 850 K ( ± 10%), if the range is not close then replace the potentiomete ...

  • Sherwood EF-3 BAYI - page 27

    WIRING DIAGRAM 27 ...

  • Sherwood EF-3 BAYI - page 28

    WARRANTY Sherwood Industries Ltd. gives a five y ear limited warr anty on all steel manufa ctured parts. A one year warra nty is provided on all ele ctrical components. The above limited warranties are extended only to the original purchas er. There is no warranty on the following parts: - Glass window - Fiberglass rope baskets - Refractory materia ...

Fabricante Sherwood Categoría Stove

Los documentos del dispositivo Sherwood EF-3 BAYI que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Sherwood
- manuales de instrucciones EF-3 BAYI
- hojas de producto Sherwood
- folletos informativos
- o etiquetas energéticas Sherwood EF-3 BAYI
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Sherwood EF-3 BAYI.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Sherwood EF-3 BAYI, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Sherwood EF-3 BAYI. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Sherwood EF-3 BAYI.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Sherwood EF-3 BAYI, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Sherwood EF-3 BAYI. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Sherwood EF-3 BAYI.

El manual de instrucciones completo de Sherwood debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Sherwood EF-3 BAYI - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Sherwood EF-3 BAYI, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Sherwood EF-3 BAYI que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Sherwood EF-3 BAYI - que deben facilitarnos los primeros pasos durante el uso de Sherwood EF-3 BAYI
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Sherwood EF-3 BAYI
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Sherwood EF-3 BAYI en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Sherwood EF-3 BAYI?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Sherwood EF-3 BAYI, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Sherwood EF-3 BAYI probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)