    OBX -IC2024S -120/60 O wner ’ s Manual Installation and Operation Rugged Water Resistan t Inverter / Charger ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 2

    OutBack Po wer S yst ems OutBack Po wer Sy stems is a leader in advanced ener gy conv ersion technology . Our products include true sine wave in ver ter/chargers, maximum po wer point charge c ontrollers , system communica tion components, as w ell as breaker panels , breakers , accessories, and assembled sy stems. Con tact Information T elepho ne: ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 3

    1 T ABLE OF C ONTENTS Welcome to the OutBack Extreme Rugged Water Resistant Inverter/Charger ............................................ 2 P arts I ncluded................................................................................................................................................................ ........................3 Unit Di ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 4

    2 W elcome to the OutBack Extreme Rugged W ater Resistant Inv er ter/Char ger The OutBack Extreme Rugged Water Resistant Inverter/Charger (hereafter called the Inverter) provides 120 Vac, 60 Hz, true-sine wave power, from a 24 Vdc battery source. It is designed for rugged operational environments in an unprotected, uncontrolled climate. This equipm ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 5

    3 P ar ts Included Standard with the OutBack Extreme Rugged Wat er Resistant Inverter/Charger , Model OBX-IC2024S-120/60 : • OneOwner ’ sManual • OneDCCov er(DCC) • Onered(positive)andoneblack(negativ e)batteryterminalcap Additional parts, included when purchasing the complete sy stem OB ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 6

    4 R EA D F IR S T ! SA VE THESE INSTRUCTIONS Read all instructions and cautionary markings on the Inverter, the batteries and all appropriate sections of this installation and user manual as well as other component manuals before using the system. Be cautious around electricity, electrical components, and batteries. Shocks, burns, injury, and even ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 7

    5 Designthebatteryenclosuretopreventaccumulationandconcentrationofhydrogengasin“pockets”at the top of the enclosure. Vent the battery compartment from the highest point to the outside. A sloped lid can also be used to direct the ow of hydrogen to the vent opening. CA UTION To reduce risk of injury ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 8

    6 MOUNTING TheInverterweighs57.5lbs(26.08kg)andmustbesecuredwithappr opriatefastenerstoastur dy • mounting sur face capable of supporting its weight. Depending on application, it may be easier for two people to install the unit due to the Inv er ter’ s weight. If internally mounted (protecte ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 9

    7 The equipment ground on each is marked with this symbol: Box lug for grounding the Inverter chassis SY STEM PRO TEC TION Electrical systems are designed to protect you, the wires, the components, and the devices served by the system. Each Inverter must be par t of a permanently grounded electrical system (see below). Gr ounding • protects pe ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 10

    8 WIRE C ONNEC TIONS DC Wiring TheInverterusesDCbrassbatteryterminalswith8Mx1.00stainlesssteelthreadedstuds.Youcanaccess the terminals by removing the four screws that attach the DC cover plate, and pulling it o. Red terminal=battery positive Battery terminal covers Black terminal = batter ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 11

    9 12 V/200 amp-hours - 12 V/200 amp-hours - 12 V/200 amp-hours - V oltage remains at 12 V 200 Ah + 200 Ah + 200 Ah + 200 Ah = 800 Ah 12 V/200 amp-hours 12 V/200 amp-hours 12 V/200 amp-hours 12 V/200 amp-hours 12 V + 12 V + 12 V + 12 V = 48 V Amp-hours remain at 200 T wostringsofbatteriesinseriesareconnectedinparallel. ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 12

    10 6 V Batter y Wiring Examples f or a 24-volt system - DC DISCONNECT (FUSE OR CIRCUIT BREAKER) - - - - SERIES: 200 amp-hours - - DC DISCONNECT (FUSE OR CIRCUIT BREAKER) - - - - - - - SERIES STRING 1 SERIES STRING 2 SERIES STRING 2 CONNECTS TO INVERTER’ S NEGA TIVE TERMINAL SERIES STRING 1 CONNECTS TO INVERTER’S POSITIVE TERMINAL SERIES/P ARALL ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 13

    11 12 V Batter y Wiring Examples f or a 24-volt system - DC DISCONNECT (FUSE OR CIRCUIT BREAKER) - - SERIES: 200 amp-hours - - - - SERIES STRING 1 CONNECTS TO INVERTER’S POSITIVE TERMINAL DC DISCONNECT (FUSE OR CIRCUIT BREAKER) SERIES STRING 2 SERIES/P ARALLEL: 400 amp -hours SERIES STRING 1 - 12 V/200 amp-hours 12 V/200 amp-hours 12 V/200 amp-ho ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 14

    12 A C Wiring A C OUT SOCKET • — Maxicon circular molded watertight connector supplies power to the loads using the pr ovided A C cable and plug. A C IN SOCKET • — Maxicon circular molded watertight connector supplies incoming AC from the grid or a generat or to the Inverter . This AC is used t o run loads and recharge batteries. MA T ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 15

    13 Follow these steps to wire the Inverter to your system: Open all DC breakers or remove any fuses before connecting wiring. 1. Open all AC breakers or remove any fuses before connecting wiring. 2. With all power o, connect the AC IN Maxicon plug wires to the AC source. The AC input wires should 3. have a (maximum) 30-amp AC breaker to provide ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 16

    14 POWERING UP Once all connections are established, it is safe to turn the power on, in the following order: Connect DC power , by closing the DC breaker or c onnecting the fuse. The MA TE will pow er up . • The Inv erter will energize and begin delivering 120 v olts to the output immediately . ( The on/o function is controlled by the MA T ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 17

    15 THE MA TE2 SYSTEM C ONTROLLER AND DISPLA Y The MATE serves several functions: Allows y ou to monitor the Inverter through a series of con venient display scr eens. These display • the status messages, and allow y ou to take both DC (voltage) and A C (voltage and current) meter readings . Enables you to tr oubleshoot problems with the Invert ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 18

    16 < OFF > —turns o all Inverters connected to the MATE < SRCH > —the Inverter begins search mode if the AC load connected is smaller than allowed by the programming of the search function. This function is not normally required to be used with the OBX-IC2024S-120/60 Inverter. < ON > —turns on all Inverters connected to t ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 19

    17 The AC INPUT C ONTROL screen is called up, allowing the user • to connect or disconnect the Inverter to an AC input source . AC INPUT CONTROL currently: USE DROP USE OK < USE > enables the Inverter to connect to an AC input source. < DROP > disconnects the AC input source but will allow it to be reconnected if the “low battery ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 20

    18 PRESS THREE TIMES: The CHARGER CONTROL scr een appears. This allows the • operation of the Inverter ’ s battery charger to be preset f or an available A C source . CHARGER CONTROL currently: AUTO OFF AUT O ON OK < OFF > disables all charger functions in the Inverter. < AUTO >enablesautomaticbatterycharging,silen ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 21

    19 MAIN-------------------------------- 12:00:30P SUM ST A TUS SETUP ADV The user can press the <SUM> soft key to display the Summary screen. FX T otal 25.2V Inverting 0.000kW AC Loads 0.000kW Buying $ 0.000kW SUM Soft Key MAIN-------------------------- 1:35:04p SUM ST A TUS SETUP ADV S ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 22

    20 SETUP SCREENS The Setup screens allow you to change several settings, to make your system run more smoothly. You can program the amperage size of the AC source, to keep the Inverter from overdrawing a generator. You can program the Summary screen to pop up automatically like a computer screensaver. In advanced systems, you can order the MATE to ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 23

    21 SETUP/MA TE/SUMMARY --------- summary control BACK T YPE DELA Y ROLL MAIN-------------------------------- 12:00:30P SUM ST A TUS SETUP ADV SETUP/MA TE/PAGE1-------------- mate code rev 4.1.6 choose category CLOCK CNT GLOW PG2 SETUP------------------------------ choose category: FX MA TE SUMMAR Y SETUP SCREENS SETUP/MA TE/PAGE2-------------- choo ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 24

    22 SETUP/MA TE/SUMMARY ---------- summary control BACK T YPE DELA Y ROLL After selecting FX Only and exiting the SETUP/MATE/SUM/ TYPE screen, the SUMMARY screen will automatically appear whenever the MATE has been inactive for the < DELAY > set point (very much like a screensaver on a computer monitor). If“None”wasselected,the ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 25

    23 SETUP/MA TE/SUMMARY/T YPE-- sum screen 19 minutes delay time BACK INC DEC SETUP/MA TE/PAGE2-------------- choose category: PG1 SUMRY COM MAIN SETUP/MA TE/SUMMARY ---------- summary control BACK T YPE DELA Y ROLL SETUP/MA TE/SUMMARY/T YPE-- sum screen 19 minutes delay time BACK INC DEC Sum screen delay time in SUMMARY mode shows how long it takes ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 26

    24 •< REPOLL >forcestheMATEto“rediscover”alltheOutBack devices it is connected to. This must be used any time an OutBack device is moved or added to a HUB. •< PC > and < DEBUG > are not normally used with the OBX-IC2024S-120/60 Inverter. The MATE has found the HUB and will automatically go ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 27

    25 Press < STATUS > on the Main menu to access the STATUS menu. STATUS contains all the meters and mode displays for OutBack products connected to the MATE. The STATUS menu is divided rst by product and then into menu categories, such as meter, modes, and statuses. The < FX > soft key is used to access the Inverter’s status menus. ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 28

    26 ST A TUS/FX/PAGE1--------------- choose category MODES METER BA T T PG2 ST A TUS/FX/PAGE2--------------- choose category PG1 ERROR WARN PG3 ST A TUS/FX/PAGE3--------------- choose category PG2 DISCON SELL MAIN MODES • : not recommended f or use with the OBX-IC2024S-120/60 Inv erter -- do not selec t this option METER • : displays in ve ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 29

    27 METER Screens The METER screens displays current, voltage and wattage measurements, Inverter status, and the version of Inverter software, in this order: initial screen, beginning with • charge/inv ert/oat /etc: shows the unit’ s operating mode (see table to the right) – inv – : kilowatts being taken from the batteries while inv er ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 30

    28 ST A TUS/FX/MODE-------------P00 battery 27 .8 vdc actual DOWN ST A TUS PORT ST A TUS/FX/METER-------------P00 absorb 28.8 vdc setpoint DOWN UP TOP PORT ST A TUS/FX/MODE-------------P00 battery 27 .8 vdc temp compensated DOWN UP TOP PORT ST A TUS/FX/BA T T ---------------P00 absorb 00.0 hrs time remaining DOWN UP TOP PORT ST A TUS/FX/BA T T ---- ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 31

    29 ST A TUS/FX/PAGE2------------------- choose category: PG1 ERROR W ARN PG3 ERROR Screens Allscreensreadstatusas“No”undernormalconditions.Iftheunitshutsoduetoaspeciederrorcondition,that screenwillchangeto“Yes”. • low ac output voltage : load too ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 32

    30 ST A TUS/FX/WARN-------------P00 acin freq No too low DOWN UP T OP PORT ST A TUS/FX/WARN-------------P00 acin freq No too high DOWN ST A TUS PORT ST A TUS/FX/WARN--------------P00 acin voltage No too high DOWN UP T OP POR T ST A TUS/FX/WARN-------------P00 acin input No current exceeds max DOWN UP T OP PORT ST A TUS/FX/WARN-------------P00 acin ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 33

    31 ST A TUS/FX/DISCON-----------P00 acin freq No too high DOWN ST A TUS PORT ST A TUS/FX/DISCON-----------P00 acin voltage No > max DOWN UP T OP PORT ST A TUS/FX/DISCON----------P00 acin freq No too low DOWN UP T OP PORT ST A TUS/FX/DISCON-----------P00 acin voltage No < min DOWN UP T OP PORT ST A TUS/FX/PAGE2---------------- choose category: ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 34

    32 INST ALLA TION DRA WING A 30A input breaker (maximum) must be • used with the AC sourc e A 30A breaker (maximum) must be used to • protect the output circuit A single Inverter can continuously power • up to 2.0 kW of loads depending on the ambient temperatur e. ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 35

    33 INST ALLA TION CHECK LIST ITEM YES NO Manual read and reviewed? System mount ed with the recommended number and siz ed fasteners? System installed ac cording to r equired codes and r egulations? System inspected? System g rounded? Inverter output connected to load circuit with 30 A C amp maximum over current prot ection? Inverter AC sourc es pro ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 36

    34 OBX -IC2024S-120/60 Inverter/Charger Specications Nominal DC Input Voltage Range 24 Vdc Nominal AC Voltage / Frequency 120 Vac / 60 Hz ContinuousPowerRatingat25°CAmbient 2000 VA ContinuousACRMSOutputat25°C 16.7Aac Idle Power - Full AC Output ≈ 20 watts Idle Power - Search Mode 6 watts Typical Eciency 92 ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 37

    35 AC Input Operating Voltage Range Note : This is the rec ommended AC input voltage r ange to be supplied to the Inver ter . V oltages outside of this range will not be accepted b y the Inverter. OBX-IC2024S-120/60 Inverter 80–150Vac(Vac=voltsAC) AC Input Frequency Range Note : If the AC input sourc e is out of the range ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 38

    36 INVERTER DEF A UL T V AL UES (subjec t to change with upgrades) 24 VDC System DEFAULT MINIMUM MAXIMUM Float Voltage 27.4Vdc 24 Vdc 30 Vdc Absorb Voltage 29.4Vdc 26 Vdc 32 Vdc EQ Voltage 28.8V 28Vdc 34 Vdc ReFloat 25Vdc 22 Vdc 26 Vdc LBCO 21 Vdc 18Vdc 24 Vdc Absorb Time 2.0 hours 0.0 hours 24.0 hours EQ Time 1.0 hours 0.0 hours ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 39

    37 Maintenance F ollowing exposure t o salt water , rinse all exposed surfaces to prevent corr osion. Recoat the DC lugs • and other exposed conductors with dielectric grease. P eriodically check that the battery cable lugs are tight and secure accor ding to the recommended • torquesettingsonpage8. Brush o excessiv e dust f ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 40

    38 1- Y ear Limited W arranty OutBack Extreme Inverter/Chargers OutBackPowerSystems,Inc.(“OutBack”)providesaoneyear(1)limitedwarranty(“Warranty”)against defectsinmaterialsandworkmanshipforitsOutBackExtremeInverter/Charger(“Product”)ifinstalledin aperm ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 41

    39 After receiving the RMA number, pack the Product(s) authorized for return, along with a copy of the original purchase invoice and warranty certicate, in the original Product shipping container(s) or packaging providing equivalent protection and mark the outside clearly with the RMA number. The sender must prepay all shipping charges, and insu ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 42

    40 OUTBA CK EX TREME INVERTER/CHARGER LIMITED W ARRANTY REGISTR A TION Complete this form and return it to: OutBack P ower Systems Inc. 19009 62nd Ave . NE • Arlington, W A 98223 EXTREME LIMITED W ARRANTY REGISTR A TION Equipment Owner: Name/Rank : _________________________________________________________________ Organization/Branch of Ser vice: ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 43

    41 ...

  • Outback Power Systems OBX-IC2024S-120/60 - page 44

    Corpora te Headquarters 1900962ndAv enueNE Arlington, W A98223USA Phone:(+1)360.435.6030 www.outbackpower .com 900-0046-01-00REVA European Sales Oce Barcelona, España Phone:+34.93.654.9568 ...

Fabricante Outback Power Systems Categoría Battery Charger

Los documentos del dispositivo Outback Power Systems OBX-IC2024S-120/60 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Outback Power Systems
- manuales de instrucciones OBX-IC2024S-120/60
- hojas de producto Outback Power Systems
- folletos informativos
- o etiquetas energéticas Outback Power Systems OBX-IC2024S-120/60
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Outback Power Systems OBX-IC2024S-120/60.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Outback Power Systems OBX-IC2024S-120/60, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Outback Power Systems OBX-IC2024S-120/60. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Outback Power Systems OBX-IC2024S-120/60.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Outback Power Systems OBX-IC2024S-120/60, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Outback Power Systems OBX-IC2024S-120/60. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Outback Power Systems OBX-IC2024S-120/60.

El manual de instrucciones completo de Outback Power Systems debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Outback Power Systems OBX-IC2024S-120/60 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Outback Power Systems OBX-IC2024S-120/60, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Outback Power Systems OBX-IC2024S-120/60 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Outback Power Systems OBX-IC2024S-120/60 - que deben facilitarnos los primeros pasos durante el uso de Outback Power Systems OBX-IC2024S-120/60
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Outback Power Systems OBX-IC2024S-120/60
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Outback Power Systems OBX-IC2024S-120/60 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Outback Power Systems OBX-IC2024S-120/60?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Outback Power Systems OBX-IC2024S-120/60, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Outback Power Systems OBX-IC2024S-120/60 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)