Manual de instrucciones Sigma IB600

25 de páginas 1.7 mb
Descargar

Pasar a la página of 25

Summary
  • Sigma IB600 - page 1

    G8860_4 Installation Manual NZ.doc IB1100, IB850, IB600 Installation Manual NEW ZEALAND EDITION Important: The appliance shall be insta lled in accordance with; • This installation instruction booklet • Local gas fitting regulations • Municipal building codes • Electrical wiring regulations • AS 5601 / AG 601—2000, Gas installations / N ...

  • Sigma IB600 - page 2

    G8860 _4 Installation Manual NZ 2 Note: THERE ARE FOUR MAIN THINGS TO CONSIDER BEFORE INSTALLATION • Cavity Dimensions & Clearances • Coupling of Flue to Fire • Coupling of Gas Lines to Fire • Fixing the Fire to the Cavity The sequences you choose to do these tasks will vary on your individual scenario. Please read these instructions fu ...

  • Sigma IB600 - page 3

    G8860 _4 Installation Manual NZ 3 Contents: S e c t i o n : • Product Description 1.0 • Creating the Cavity 2.0 • Ventilating the Cavity 3.0 • C a v i t y B a s e 4.0 • H e a r t h 5.0 • Raised Installations Up a Wall 6.0 • W a l l L i n i n g s 7.0 • Mantle Clearance 8.0 • Television Clearance 8.1 • Corner Installations 9.0 • ...

  • Sigma IB600 - page 4

    G8860 _4 Installation Manual NZ 4 565 580 615 270 130 40 = = 587 795 690 555 650 550 510 Masonary Onl y 165 350 1.0 Product Description: The Escea IB1100, IB850 and IB600 gas fires are des igned to be built into a cavity. These appliances are flued conventio nally via Ø100mm flue system. The user will control their fire with the Radi o Frequency ( ...

  • Sigma IB600 - page 5

    G8860 _4 Installation Manual NZ 5 C A B 2.0 Creating the Cavity: The dimensioned drawing below shows the size of the opening that must be created to keep combustible materials at the r equired distance from the heater. Note: It is not necessary to line the side, top or ba ck o f the cavity. 2.1 Where possible, it is recommended that ca vity is made ...

  • Sigma IB600 - page 6

    G8860 _4 Installation Manual NZ 6 300 200 100 1 5 0 effect on the gas fireplace. This may result in nuisance shut down and give an E3 error code on the handheld remote. IMPORTANT: For the power flue installation, a singl e Ø120mm hole, covered with a suitable louvre plate, centrally located at the base of the cavity is required. 3.1 It is also hig ...

  • Sigma IB600 - page 7

    G8860 _4 Installation Manual NZ 7 8.0 Mantle Clearance: Please refer to the diagram on the previous page. Mantles or prot ruding ledges mounted above the heater that are made from combustible materials, must not extend outside of the dimensions shown. 8.1 Television Clearances: The following are the recommended minimum clearanc es for the location ...

  • Sigma IB600 - page 8

    G8860 _4 Installation Manual NZ 8 1260mm 2380mm 11 9 0 m m 560mm 596mm 596m m 1683mm 9.3 IB1100 minimum corner install dimensions: 10.0 Pow er Supply: Whilst the cavity is being created considerati on should be given to appropriate location of a standard 3 pin, EARTHED 240V power outlet. This must be within 0.5 m of the rear left hand corner of the ...

  • Sigma IB600 - page 9

    G8860 _4 Installation Manual NZ 9 DESIGN EXAMPLE ONL Y LONG SECTION THROUGH FLUE ENCLOSURE Scale: 1:10 Angle fixing bracket supplied with flue kit . 100 150 25 25 Seal - De ck T ight or simil ar 5 0 0 mm c l e a r a n c e t o n e a r e s t p a r t o f r o o f Gap between flue sh ield and any timber Trimmers shown diagra mma tic GENERAL CONSTRUCTION ...

  • Sigma IB600 - page 10

    G8860 _4 Installation Manual NZ 10 FROM NZS 5261:2003, please ensure compliance to all other relevant sections of this code. 2.6.13 FLUE TERMINALS 2.6.13.1 Location The termination point of a flue shall be located in relation to any associated building and to neighbouring structures so that wind from any direction is not likely to create a do wndra ...

  • Sigma IB600 - page 11

    G8860 _4 Installation Manual NZ 11 12.3 IB1100: The IB1100 Outer Skin Kit has 4 possible ent ry points for solid gas pipe, on the four corners of the kit. Each is sealed by a ‘kno ck-out’. Remove only the knock-out which you require, and place the supplied rubber plug into the hole. You will need to make a small cut into the rubber plug to allo ...

  • Sigma IB600 - page 12

    G8860 _4 Installation Manual NZ 12 13.2 Attach the Rear to the Sides and Base: The rear panel fits inside the Side and Base panels, make sure the flanges on the Side and Base panels are on the outside. The two holes on the Rear panel go towards the bottom. 13.3 Attach the Top-Rear: Attach the top-rear panel to the Sides and Rear panels, with the fl ...

  • Sigma IB600 - page 13

    G8860 _4 Installation Manual NZ 13 15.0 Insert the Flue Supp ort Bracket (IB1100 Only): Place the Flue Support Bracket in line with the flue hole on the Top-Rear panel. The Flue should be ready to pass through the hole in the OSK and mate with the Gas Fire Spigot. The Flue Liner should rest on top of the Flue Support Bracket and self locate. 16.0 P ...

  • Sigma IB600 - page 14

    G8860 _4 Installation Manual NZ 14 Step 2: Lift out glass and place it carefully aside. 18.0 Connecting Flue to Heater: This is a 7 step process and is performed after the heater has been pushed into position in the cavity and before fascia panels have been fitted. 1) Remove glass as shown above. 2) Remove the log set and its associat ed packaging ...

  • Sigma IB600 - page 15

    G8860 _4 Installation Manual NZ 15 It should now be possible to reach up from inside of the heater and connect the flue to the heater’s flue spigot as per sections 18.1 and 18. 2. This junction should be made fast with both sealant and a fixing screw. 18.1 18.2 Note: If installing a flue system into a framed ti mber wall the outer liner should no ...

  • Sigma IB600 - page 16

    G8860 _4 Installation Manual NZ 16 20.0 Fixing the Heater to the Base and Wall: There are several ways that the heat er can be fixed against movement: It is a requirement that this heater be securely fa stened to the wall and base. Note: It is important that the outer fascia is used during this process to ensure that the heater is located in the ap ...

  • Sigma IB600 - page 17

    G8860 _4 Installation Manual NZ 17 22.0 IB850 & IB60- Locating the Log Set After Replacing the Fire Box: 1) Remove packaging from around log sets 2) Place rear log (long rectangular one) into pos ition by inserting it in behind retainer brackets at rear of fire box. 3) Place the front log sets into position ov er the top of the main burners. Us ...

  • Sigma IB600 - page 18

    G8860 _4 Installation Manual NZ 18 IB850 Log & Template Position 4) Line up some of the coals that have been supplied with this appliance, along the burner holes in front of the logs. 5) Scatter the remaining coals around to fill the empty spaces left over. ...

  • Sigma IB600 - page 19

    G8860 _4 Installation Manual NZ 19 22.1 IB1100- Locating the Log Set Afte r Replacing the Fire Box: 1) Remove packaging from around log sets 2) Place 2 x rear logs (long rectangular ones) in to position by inserting in behind retainer brackets at rear of fire box. 3) Place front three log sets into position ov er the top of the main burners. Use th ...

  • Sigma IB600 - page 20

    G8860 _4 Installation Manual NZ 20 22.2 Log Replacement: The fire unit should never be used with broken logs . Turn off the fire and allow the unit to cool before removing the glass to carefully remo ve the logs. If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in ...

  • Sigma IB600 - page 21

    G8860 _4 Installation Manual NZ 21 pressures listed on the table below then rea ssess installation pipe size or upstream regulator settings. Replace inlet test point screw. 3) Remove the operating pressure test point screw. Connect manomet er tube and measure pressure with heater running on full (all bur ners running) and with all the other gas app ...

  • Sigma IB600 - page 22

    G8860 _4 Installation Manual NZ 22 25.0 Fitting the Fascia Panels: To avoid scratches or knocks to the fascia panels of this heater they must be fitted at th e complete conclusion of the installation process. It may be necessary to use the outer fascia to initially locate the heater but then remove it again so that there is no chance of damage. Not ...

  • Sigma IB600 - page 23

    G8860 _4 Installation Manual NZ 23 25.1 When installing a 4 sided fascia ensure that the clips that the outer fascia screw into are at the bottom of the slot on whic h they are attached as shown below. The outer fascia should be pushed down onto the top lip so that it is as low as possible and the screw holes in the fascia line up with the lowered ...

  • Sigma IB600 - page 24

    G8860 _4 Installation Manual NZ 24 27.0 Normal Operating Sounds and Smells; Note: Each time the fire is lit from cold the glass may fog up with condensation. This is normal and the condensation will disappear within a few minut es once the glass heats up. 27.1 Sounds It is possible that you will hear some sounds fr om your gas appliance. This is pe ...

  • Sigma IB600 - page 25

    G8860 _4 Installation Manual NZ 25 28.0 Installation Check List: 1 Ensure there is adequate ventilation in the cavity. 2 Ensure the spark electrodes are correctly positioned. 3 Operating pressure checked wi th heater running on full (all burners operating) and all other gas appliances in the house s w i t c h e d o n . 4 Flue Draw checked, 5 minute ...

Fabricante Sigma Categoría Indoor Fireplace

Los documentos del dispositivo Sigma IB600 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Sigma
- manuales de instrucciones IB600
- hojas de producto Sigma
- folletos informativos
- o etiquetas energéticas Sigma IB600
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Sigma IB600.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Sigma IB600, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Sigma IB600. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Sigma IB600.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Sigma IB600, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Sigma IB600. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Sigma IB600.

El manual de instrucciones completo de Sigma debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Sigma IB600 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Sigma IB600, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Sigma IB600 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Sigma IB600 - que deben facilitarnos los primeros pasos durante el uso de Sigma IB600
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Sigma IB600
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Sigma IB600 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Sigma IB600?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Sigma IB600, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Sigma IB600 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)