    036- 21528-001- A-0303 FOR DISTRIBUTION USE ONL Y - NOT TO BE USED A T POINT OF RET AIL SALE ® CHAMPIONÆ PLUS SINGLE PACKAGE HEAT PUMPS B1HP024 THRU 0 48 2 THRU 4 NOMINAL TONS 13 SEER FACTORY MOUNTED TXV DESCRIPTION These package d heat pump s are desi gned for outdoor instal lation. O nly utilit y and d uct connec tions ar e required at the poi ...

  • York B1HP024 THRU 048 - page 2

    036-215 28-001- A-0303 2 Unitary Products G roup CONDENSA TE P AN A non-corrosiv e, long-lasting, wate r-tight pan is posi- tioned bel ow the evapo rator coil to collect and drain all conde nsate; less collectio n of st agnate con densate wi ll build-u p. The cond ensate pan c onforms to A SHRAE 62-89 s tandards (Ven tilation for Acceptabl e Indoor ...

  • York B1HP024 THRU 048 - page 3

    0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 3 PROTECTED COMPRESSOR The compr ess or is i nternal ly prote cted agai nst high pressu re and temp erature. Th is is accomp lished b y the simulta neous ope ration of high pre ssure rel ief valve and a tempe rature sen sor which pr otects the c ompres- sor, if undesir able operati ng ...

  • York B1HP024 THRU 048 - page 4

    036-215 28-001-A-0303 4 Unitary Products G roup RECT ANGLE TO ROUND ADAPTE RS Kit inc ludes one s upply a nd one retur n air rect angle to round d uct adapte r. Adapters a re prefo rmed and design ed to fit over current duc t openings o n the base unit . Transition is from 15" s quare to 1 4" round. ROOF CURBS NRCA a pproved cu rbs prov i ...

  • York B1HP024 THRU 048 - page 5

    0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 5 SEER = Seasonal Ene rgy Efficiency Ratio - the total cool ing output in B TU's during a normal ann ual usage pe riod for c ooling divi d ed by the total el ectric power inpu t in watt-hours during the same period. COP = Coefficient of Perform ance - the total h eating capacity p ...

  • York B1HP024 THRU 048 - page 6

    036-215 28-001-A-0303 6 Unitary Products G roup T ABLE 3: COOLING CAP ACITIES - 2 TON (BHP0 24) TEMPERA T URE AIR ON OUTDOOR COIL TEMPERA TURE OF AIR O N INDOOR COIL 800 CF M 900 C FM WB ∞ FW B ∞ F 72 67 6 2 57 72 67 62 57 85 ∞ F NET CA P . MBH 29.1 26.0 23. 8 23.4 29.7 26.6 24.3 23 .9 POWER I NPUT kW 1.93 1.91 1.8 8 1.87 1.95 1.93 1.91 1.9 0 ...

  • York B1HP024 THRU 048 - page 7

    0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 7 T ABLE 4: COOLING C AP ACITIES - 2-1/2 T ON (BHP030) TEMPERA T URE AIR ON OUTDOOR COIL TEMPERA TURE OF AIR ON INDOOR COIL 1000 CFM 1 1 25 CFM WB ∞ FW B ∞ F 72 67 62 57 72 67 62 57 85 ∞ F NET CA P . MBH 34.1 31.5 28.4 29.9 35.4 32.7 29.5 31.0 POWER I NPUT kW 2.52 2.48 2.44 2.43 ...

  • York B1HP024 THRU 048 - page 8

    036-215 28-001-A-0303 8 Unitary Products G roup T ABLE 5: COOLING CAP ACITIES - 3 TON (BHP0 36) TEMPERA T URE AIR ON OUTDOOR COIL TEMPERA TURE OF AIR ON INDOOR COIL 1050 CFM 1200 CFM WB ∞ FW B ∞ F 72 67 62 57 72 67 62 57 85 ∞ F N E T C A P . M B H 4 1 . 13 7 . 53 4 . 53 4 . 34 2 . 43 8 . 63 5 . 53 5 . 3 POWER I NPUT kW 2.89 2.81 2.73 2.73 3.0 ...

  • York B1HP024 THRU 048 - page 9

    0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 9 T ABLE 6: COOLING C AP ACITIES - 3-1/2 T ON (BHP042) TEMPERA T URE AIR ON OUTDOOR COIL TEMPERA TURE OF AIR ON INDOOR COIL 1300 CFM 1400 CFM WB ∞ FW B ∞ F 72 67 62 57 72 67 62 57 85 ∞ F NET CA P . MBH 48.8 44.5 40.5 40.6 49.2 44.9 40.8 41.0 POWER I NPUT kW 3.37 3.32 3.21 3.20 3. ...

  • York B1HP024 THRU 048 - page 10

    036-215 28-001-A-0303 10 Unitary Products G roup T ABLE 7: COOLING CAP ACITIES - 4 TON (BHP0 48) TEMPERA T URE AIR ON OUTDOOR COIL TEMPERA TURE OF AIR ON INDOOR COIL 1500 CFM 1600 CFM WB ∞ FW B ∞ F 72 67 62 57 72 67 62 57 85 ∞ F N E T C A P . M B H 5 4 . 35 0 . 44 5 . 74 8 . 25 4 . 95 1 . 04 6 . 34 8 . 8 POWER I NPUT kW 3.97 3.85 3.75 3.74 4. ...

  • York B1HP024 THRU 048 - page 11

    0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 11 T ABLE 8: HEA TING CAP ACITI ES - 2 TON (BHP024) CFM RETURN AIR ∞ F CAP 1 & KW OUTDOOR AIR TE MPERA TURE, ∞ F (72% RH) -10 0 10 20 30 40 50 60 600 55 MBH 10.216 1 1.748 13.601 1 5.843 18.55 4 21.83 4 25.801 30. 601 KW 1 .214 1.307 1 .401 1.494 1.588 1.681 1.7 75 1.868 70 MBH ...

  • York B1HP024 THRU 048 - page 12

    036-215 28-001-A-0303 12 Unitary Products G roup T ABLE 10: HE A TING CAP ACITIES - 3 TON (BHP036) CFM RETURN AIR ∞ F CAP 1 & KW OUTDOOR AIR TEM PERA TURE, ∞ F (72% RH) -10 0 10 20 30 40 50 60 900 55 MBH 10.597 12.792 15.4 48 18.660 22.54 5 27.244 32.92 9 39.804 KW 1.791 1. 898 2.00 5 2.1 12 2 .219 2.3 26 2.433 2 .540 70 MBH 9.420 1 1 .615 ...

  • York B1HP024 THRU 048 - page 13

    0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 13 T ABLE 12: HE A TING CAP ACITIES - 4 TON (BHP0 48) CFM RETURN AIR ∞ F CAP 1 & KW OUTDOOR AIR TEM PERA TURE, ∞ F (72% RH) -10 0 10 20 30 40 50 60 1200 55 MBH 13.911 17. 096 21.021 25. 859 31.82 1 39.1 70 48.226 5 9.388 KW 2.342 2. 568 2.79 5 3.022 3.249 3.4 76 3.703 3 .930 70 ...

  • York B1HP024 THRU 048 - page 14

    036-215 28-001-A-0303 14 Unitary Products G roup NOTE: Above da ta includes allowances for a dry i ndoor coil a nd no fil ters. For add itional pr essure dr ops, refer to the ì Additi on al Static Pressure Resistanceî table. T ABLE 13: SI DE & BOTTOM SUPPLY AIR BLOWE R PERFORMANCE (208/230/460 VOLT 1 ) MODEL NO. BHP MOTOR SPEED SETTING UNIT A ...

  • York B1HP024 THRU 048 - page 15

    0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 15 FIGURE 2 - FIELD W IRING DIAGRAM R G W R C Y Y W2 C W1 O O G THERMOST A T UNIT TERMINAL STRIP * ** ** = Minimum wire size of 18 AWG wire should be used for all field installed 24 volt wire. * = Only required on units with supplemental electric heat. PROGRAMMABLE THERMOST A T ONL Y 2 ...

  • York B1HP024 THRU 048 - page 16

    036-215 28-001-A-0303 16 Unitary Products G roup T ABLE 15: ELECTRICAL DA T A (BASIC UNIT) MODEL BHP POWER SUPPL Y V O LTA G E LIMIT A TIONS 1 COMPRESSOR OUTDOOR FA N MOTOR, FLA SUPPL Y AIR BLOWER MOTOR, FLA MINIMUM CIRCUIT AMP ACITY MAX FUSE SIZE, AMPS 2 MAX. HACR BREAKER SIZE, AMPS UNIT POWER F ACTOR TRANSFORMER SIZE (V A) MIN. MAX. RLA LRA 024 2 ...

  • York B1HP024 THRU 048 - page 17

    0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 17 * KW listed is for 240 volts, use T a ble 15 for 208 or 23 0 volts. ** KW listed is fo r 480 volts, use T able 1 5 for 460 volts. T ABLE 16: ELE CTRICAL DA T A (13 SEER HEA T PUMP / ELECTRIC HEA T) MODEL BHP POWER SUPPL Y COMP RESSOR COND FA N MOT OR FLA SUPPL Y AIR BLOWER MOTOR FLA ...

  • York B1HP024 THRU 048 - page 18

    036-215 28-001-A-0303 18 Unitary Products G roup T ABLE 17: APPLICA TION DA T A MODEL BHP 024 030 036 042 048 MINIMU M AIR FL OW (CFM) COOLING 8 00 1 000 1050 1 300 1500 HEA TIN G 800 1000 1050 1 400 1400 MAXIMUM AIR FLOW (CFM) COOLING 9 00 1 1 25 1200 1400 1 600 HEA TIN G 900 1 125 1200 1500 1 600 MINIMUM OPERA TING TE MPERA TURE IN COOLING MODE ( ...

  • York B1HP024 THRU 048 - page 19

    0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 19 FIGURE 5 - UNIT DIME NSIONS ...

  • York B1HP024 THRU 048 - page 20

    036-215 28-001-A-0303 20 Unitary Products G roup FIGURE 6 - TYPICAL A PPLICA TIONS ...

  • York B1HP024 THRU 048 - page 21

    0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 21 FIGURE 7 - ROOF CURB DIME NSIONS ...

  • York B1HP024 THRU 048 - page 22

    036-215 28-001-A-0303 22 Unitary Products G roup FIGURE 8 - TYPICAL W IRING DIAGRAM (208/230-1-60 POWER SUPPLY) ...

  • York B1HP024 THRU 048 - page 23

    0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 23 FIGURE 9 - TYP ICAL WIRING DIAGRAM (230-3-60 PO WER SUPPLY) ...

  • York B1HP024 THRU 048 - page 24

    036-215 28-001-A-0303 24 Unitary Products G roup FIGURE 10 - TYPICAL W IRING DIAGRAM (460-3-60 POWER SUPPLY) ...

  • York B1HP024 THRU 048 - page 25

    0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 25 MECHANICAL SP ECIFICATIONS GENERAL DESC RIPTION Units sh all be fac tory-assem bled, si ngle pac kaged, Heat Pu mps, design ed for outdoo r mounted installa- tion. Units shall have minimu m SEER rating s of 13.0. They shal l have b uilt in, equal size, fiel d convert ible duct con n ...

  • York B1HP024 THRU 048 - page 26

    036-215 28-001-A-0303 26 Unitary Products G roup B. Shall have i nternal is olation and sou nd muffling to minim i ze v ibration and noise, a nd be extern ally iso- lated on a dedicated , indep enden t mountin g. 2. Coils: A. Evaporator a nd condense r coi ls sh all have alumi- num pla te fins mechan ically bonded to seamless inter nally-enh anced ...

  • York B1HP024 THRU 048 - page 27

    0 3 6 - 2 1 5 2 8 - 0 0 1 - A - 0 3 0 3 Unitary Products G roup 27 ...

  • York B1HP024 THRU 048 - page 28

    Subject to change without notice. Printed i n U.S.A. CD: 6-215 28 036-215 28-001-A-0303 Copyri ght © by U nita ry Products Group 2003. All rights reserv ed. Supersed es: Nothing Unit ary 5005 Norma n Product s Y ork OK Group Drive 73069 This product was manufactured in a plant whose quality system is certified/registered as being in conformity wit ...

Fabricante York Categoría Heat Pump

Los documentos del dispositivo York B1HP024 THRU 048 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos York
- manuales de instrucciones B1HP024 THRU 048
- hojas de producto York
- folletos informativos
- o etiquetas energéticas York B1HP024 THRU 048
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones York B1HP024 THRU 048.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje York B1HP024 THRU 048, instrucciones de servicio, instrucciones cortas o instrucciones de usuario York B1HP024 THRU 048. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto York B1HP024 THRU 048.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo York B1HP024 THRU 048, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar York B1HP024 THRU 048. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de York B1HP024 THRU 048.

El manual de instrucciones completo de York debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual York B1HP024 THRU 048 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice York B1HP024 THRU 048, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de York B1HP024 THRU 048 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo York B1HP024 THRU 048 - que deben facilitarnos los primeros pasos durante el uso de York B1HP024 THRU 048
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con York B1HP024 THRU 048
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de York B1HP024 THRU 048 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de York B1HP024 THRU 048?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con York B1HP024 THRU 048, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con York B1HP024 THRU 048 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)