    990 - 1852 C , 10 /2005 User Manual English APC Smart - UPS ® SC 250/450 VA 110/120/230 Vac 1U Rack - Mount/Tower Uninterruptible Power Supply ...

  • APC SC450RMI1U - page 2

    ...

  • APC SC450RMI1U - page 3

    1 Introduction The APC Uninterruptible Power Supply (UPS) is designed to prevent blackouts, brow n outs, sags, and surges from re aching your equipment. The uninterruptible power supply (UPS) filters small uti l- ity line fluctuations and isolates your equipment from large disturbances by internally disconnecting from the utility line. The UPS prov ...

  • APC SC450RMI1U - page 4

    2 Rack - Mounting Œ • Ž • Two - post rack - mounting : Utilize the bracket holes that are of f set 6 .25”. • Secure clip - nuts to the rack, and attach brackets with provided screws. ‘ ...

  • APC SC450RMI1U - page 5

    3 ’ “ Tower Configuration Attention: Connect the battery before tower setup by referring to applicable steps in Rack - Mounting. ...

  • APC SC450RMI1U - page 6

    4 Wall Mounting Attention: Connect the battery before mounting by referring to applicable steps in Rack - Mounting. To avoid a safety hazard, do not mount the unit on the wall with the bezel facing downwards, or with the display panel at the bottom. Œ • Note: Whenever possible, a ttach two screws into wall studs. If stud mounting is not poss i b ...

  • APC SC450RMI1U - page 7

    5 2: S TART UP Connect Equipment t o the UPS Rear Panels 110/120 V: 230 V: Note: A laser printer draws significantly more power than other types of equipment and may ove r- load the UPS. Connect the UPS to the Network (if Applicable) Serial Port Telephone/ Network Surge Suppre s sion P orts Use only interface kits a p proved by APC. Use only the su ...

  • APC SC450RMI1U - page 8

    6 3: O PERATION Front Display Panel 110/120 V 230 V I NDICATOR D ESCRIPTION On L ine The UPS is supplying utility power to the connected equipment. On Ba t tery The UPS is supplying battery power to the connected eq uipment. Ove r load The connected loads are drawing more than the UPS power rating. Replace Ba t tery The battery must be replaced. F ...

  • APC SC450RMI1U - page 9

    7 4: U SER C ONFIGURABLE I TEMS N OTE : S ETTINGS ARE ADJUSTED THROUGH P OWER C HUTE SOFTWARE F UNCTION F ACTORY D E FAULT U SER S E LECTABLE C HOICES D ESCRIPTION Automatic Self - Test Every 14 days (336 hours) Every 7 days (168 hours), Every 14 days (336 hours), On Startup Only, No Self - Test Set the inte r val at which the UPS will execute a s ...

  • APC SC450RMI1U - page 10

    8 N OTE : S ETTINGS ARE ADJUSTED THROUGH P OWER C HUTE SOFTWARE F UNCTION F ACTORY D E FAULT U SER S E LECTABLE C HOICES D ESCRIPTION Low Battery War n ing 2 minutes PowerChute Business Edition sof t ware provides automatic, una t- tended shutdown when approx i- mately 2 mi n utes of battery ope r- ated runtime r e- mains. 2, 5, 7, 10 mi n utes (Ti ...

  • APC SC450RMI1U - page 11

    9 5: S TORAGE AND M AINTENANCE Storage Store the UPS covered in a cool, dry loc ation, with the ba t tery fully charged. At - 15 to +30 ° C (+5 to +86 ° F), charge the UPS ba t tery every six months. At +30 to +45 ° C (+86 to +113 ° F), charge the UPS ba t tery every three months. Battery Replacement The UPS battery life differs based on usage ...

  • APC SC450RMI1U - page 12

    10 6: T ROUBLESHOOTING , S HIPPING , AND S ERVICE Use the chart below to solve minor UPS installation and operat ion problems. Refer to www.apc.com with co m plex UPS problems, and for battery runtime charts. P ROBLEM AND / OR P OSSIBLE C AUSE S OLUTION UPS WILL NOT TURN ON UPS not connected to utility power supply. Check that the power cord from t ...

  • APC SC450RMI1U - page 13

    11 P ROBLEM AND / OR P OSSIBLE C AUSE S OLUTION THE OVERLOAD LED IS ILLUMINATED AND THE UPS EMITS A SU S TAINED ALARM TONE The UPS is overloaded. The connected equipment is dra w- ing more VA than the UPS can sustain. The connected equipment exceeds the specified “maximum load.” The alarm remains on until the overload is removed. Disconnect non ...

  • APC SC450RMI1U - page 14

    12 Shipping and S ervice Prepare the UPS for shipping: Shutdown and disconnect any equipment attached to the UPS. Shut down the UPS, and di s connect the UPS from the utility power outlet. Disconnect the battery. If the UPS requires service do not return it to the dealer. Fo llow these steps: 1. Review the problems discussed in Troubleshooting to e ...

  • APC SC450RMI1U - page 15

    13 7: R EGULATORY AND W ARRANTY I NFORMATION 110/120 V models This equipment has been tested and found to comply with the limits for a Class A digital device, pu r- suant to part 15 of the FCC Rules. These l imits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial enviro n ment. ...

  • APC SC450RMI1U - page 16

    14 Limited Warranty American Power Conversion (APC) warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is l imited to repairing or replacing, at its own sole o p tion, any such defective products. To obtain service under warranty you must ...

Fabricante APC Categoría Uninterruptible power supply (

Los documentos del dispositivo APC SC450RMI1U que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos APC
- manuales de instrucciones SC450RMI1U
- hojas de producto APC
- folletos informativos
- o etiquetas energéticas APC SC450RMI1U
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones APC SC450RMI1U.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje APC SC450RMI1U, instrucciones de servicio, instrucciones cortas o instrucciones de usuario APC SC450RMI1U. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto APC SC450RMI1U.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo APC SC450RMI1U, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar APC SC450RMI1U. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de APC SC450RMI1U.

El manual de instrucciones completo de APC debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual APC SC450RMI1U - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice APC SC450RMI1U, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de APC SC450RMI1U que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo APC SC450RMI1U - que deben facilitarnos los primeros pasos durante el uso de APC SC450RMI1U
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con APC SC450RMI1U
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de APC SC450RMI1U en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de APC SC450RMI1U?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con APC SC450RMI1U, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con APC SC450RMI1U probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)