    Save this manual for future reference. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, per- sonal injury, or loss of life. FOR YOUR SAFETY — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO I ...

  • Desa CGB35N - page 2

    2 100351 CONTENTS SECTION PAGE Safety Information ......................................................................... 3 Product Identification .................................................................... 5 Local Codes ................................................................................... 6 Unpacking ...................... ...

  • Desa CGB35N - page 3

    3 100351 SAFETY INFORMA TION WARNING ICON G 001 W ARNINGS IMPORTANT: Read this owner’s manual carefully and completely be- fore trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning. WARNING ICON G 001 DANGER C ...

  • Desa CGB35N - page 4

    4 100351 SAFETY INFORMA TION Continued WARNING ICON G 001 W ARNINGS Continued 6. Provide the following minimum heater clearances from combustibles (as viewed from the front of heater): Front: 48 inches Back: 6 inches Top: 53 inches Right Side: 12 inches Left Side: 6 inches 7. Do not run heater • where flammable liquids or vapors are used or store ...

  • Desa CGB35N - page 5

    5 100351 Control Knob Ignitor Button Draft Hood Outlet for Venting System Figure 2 - Vented Natural Gas Heater, Rear View Figure 1 - Vented Natural Gas Heater Control Valve Lower Front Access Panel PRODUCT IDENTIFICA TION ...

  • Desa CGB35N - page 6

    6 100351 Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of the following: • National Fuel Gas Code ANSI Z223.1, also known as NFPA 54 * • National Electrical Code ANSI/NFPA 70 * *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National ...

  • Desa CGB35N - page 7

    7 100351 INST ALLING HEA TER Continued LOCATING HEATER WARNING ICON G 001 W ARNING Maintain the minimum clearances shown in Figure 3, below. If you can, provide greater clearances. WARNING ICON G 001 W ARNING Never install the heater • in a mobile home or a recreational vehicle. • where curtains, furniture, clothing, or other flam- mable object ...

  • Desa CGB35N - page 8

    8 100351 Note: Venting/chimney materials are not supplied with heater. VENTING HEATER INST ALLING HEA TER Continued WARNING ICON G 001 W ARNING This heater has a vent safety shut-off system. This system shuts off the heater gas supply if you do not vent heater properly or the venting system is blocked. Do not operate heater if not properly vented. ...

  • Desa CGB35N - page 9

    9 100351 INST ALLING HEA TER Continued VENTING HEATER (continued) WARNING ICON G 001 W ARNING Do not vent heater in any of the following ways (see Figure 4). Heater must be vented to the out- doors. Never vent heater to another room or inside a building. The vertical section of vent pipe must extend at least two feet above the highest point of any ...

  • Desa CGB35N - page 10

    10 100351 VENTING HEATER (continued) INST ALLING HEA TER Continued Proper Size Vent To safely vent heater, the vent connector pipe must be the same diameter as the draft hood outlet on the rear of the heater. Pipe that is too small can cause flue gas to spill from the heater. Fasten vent connector to the draft hood outlet with a sheet metal screw. ...

  • Desa CGB35N - page 11

    11 100351 INST ALLING HEA TER Continued CONNECTING TO GAS SUPPLY WARNING ICON G 001 W ARNING A qualified service person must connect heater to gas supply. Follow all local codes. WARNING ICON G 001 W ARNING Never connect heater to private (non-utility) gas wells. This gas is commonly known as well-head gas. IMPORTANT: Check gas line pressure at gas ...

  • Desa CGB35N - page 12

    12 100351 Figure 7 - Gas Connection * An A.G.A. design-certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design-certified manual shutoff valve from your dealer. See Accessories , page 35. ** For purposes of input adjustment. Installation must include a manual sh ...

  • Desa CGB35N - page 13

    13 100351 INST ALLING HEA TER Continued CHECKING GAS CONNECTIONS Pressure Testing Gas Supply Piping System Test Pressures In Excess of 1/2 PSIG 1. Disconnect heater and its individual manual shutoff valve from gas supply pipe. Pressures in excess of 1/2 PSIG will damage heater regulator. 2. Cap off open end of gas pipe where manual shutoff valve wa ...

  • Desa CGB35N - page 14

    14 100351 INST ALLING HEA TER Continued INSTALLING GLASS PANEL 1. Locate the glass panel package inside the back of the heater. WARNING ICON G 001 CAUTION Before installing glass panels, inspect the edges. If you notice any chips or cracks, do not install. If the surface on either side is deeply scratched, do not install. If these conditions exist, ...

  • Desa CGB35N - page 15

    15 100351 INST ALLING HEA TER Continued 2 1 Glass Panel Lower Glass Retaining Channel Figure 11 - Inserting Top Edge of Glass Panel into Upper Glass Retaining Channel 2 1 Glass Panel Lower Glass Retaining Channel Upper Glass Retaining Channel Lower Front Access Area Figure 12 - Inserting Glass into Lower Retaining Channel 7. Lower glass into lower ...

  • Desa CGB35N - page 16

    16 100351 FRESH AIR FOR COMBUSTION AND VENTILA TION WARNING ICON G 001 W ARNING This heater must have fresh air for proper operation. If not, poor fuel combustion and improper venting of flue gases will result. Carbon monoxide poisoning from backed-up flue gases could occur. Read the following instructions to insure proper fresh air for this and ot ...

  • Desa CGB35N - page 17

    17 100351 FRESH AIR FOR COMBUSTION AND VENTILA TION Continued Typical Water Heater Match Draft Hood Vent Pipe Heater Match Draft Hood Opening Vent Pipe Figure 13 - Checking for Draft Spillage No Draft Hood Spillage: This shows there is enough fresh air in area for appliances. Turn off all exhaust fans and appliances if desired. DETERMINING FRESH-AI ...

  • Desa CGB35N - page 18

    18 100351 FRESH AIR FOR COMBUSTION AND VENTILA TION Continued Figure 14 - Ventilation Air from Outdoors IMPORT ANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controlled power vent. Chimney or Gas Vent Outlet Air Ventilated Attic Outlet Air Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic D ...

  • Desa CGB35N - page 19

    19 100351 FRESH AIR FOR COMBUSTION AND VENTILA TION Continued Figure 15 - Ventilation Air from Inside Building Example 2: Locating Heater in Confined (Closed) Area NOTICE A confined area has an air volume of less than 50 cubic feet for each 1000 BTU/Hr input rating of all appliances in the area (cubic feet equals length x width x height of area). I ...

  • Desa CGB35N - page 20

    20 100351 OPERA TING HEA TER PILOT HIGH LOW DEPRESS FOR OFF Figure 16 - Control Knob and Ignitor Button Control Knob FOR YOUR SAFETY READ BEFORE LIGHTING NOTICE If operating heater for the first time, a slight odor will occur. This odor will go away after a few hours of operation. WARNING ICON G 001 W ARNING Heater and venting system surfaces are v ...

  • Desa CGB35N - page 21

    21 100351 5. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information at the top of page 20. If you don’t smell gas, go to the next step. 6. Turn control knob clockwise Clockwise to the PILOT position. Fully depress control knob for five seconds. Not ...

  • Desa CGB35N - page 22

    22 100351 MANUAL LIGHTING PROCEDURE 1. Remove lower front access panel on heater. 2. Locate pilot. Pilot is attached to the front of burner. 3. Follow steps 1 through 6 under Lighting Instructions , pages 20 and 21. 4. With control knob depressed, strike match. Hold match to pilot until pilot lights. 5. Follow steps 8 through 11 under Lighting Inst ...

  • Desa CGB35N - page 23

    23 100351 INSPECTING PILOT AND BURNER FLAME Check pilot flame pattern and burner flame pattern often. PILOT FLAME PATTERN Figure 18 shows a correct pilot flame pattern. Figure 19 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will prevent the thermocouple from getting hot, causing the heater ...

  • Desa CGB35N - page 24

    24 100351 INSPECTING PILOT AND BURNER FLAME Continued Sharp Blue Flame High Yellow Flame Flame Lifting Off of Burner Figure 21 - Incorrect Burner Flame Patterns If burner flame pattern is incorrect, as shown in Figure 20 • turn heater off (see To Turn Off Gas to Appliance , page 22) • see Troubleshooting , pages 26 through 29. Figure 20 - Corre ...

  • Desa CGB35N - page 25

    25 100351 WARNING ICON G 001 W ARNING Turn off heater and let cool before cleaning or servicing. WARNING ICON G 001 W ARNING Keep heater clear and free from combustible materials, gasoline, and other flammable vapors and liquids. WARNING ICON G 001 CAUTION You must keep control areas, burner, and circulating air passageways of heater clean. Inspect ...

  • Desa CGB35N - page 26

    26 100351 TROUBLE- SHOOTING Note: All troubleshooting items are listed in order of operation. WARNING ICON G 001 W ARNING Turn off and unplug heater and let cool before servicing. Unless you need gas supply for testing, shut off manual shutoff valve before servicing. Only a qualified service person should service and repair heater and venting syste ...

  • Desa CGB35N - page 27

    27 100351 TROUBLE- SHOOTING Continued Continued OBSERVED PROBLEM Pilot lights but flame goes out when control knob is released. Burner does not light after pilot is lit. Delayed ignition of burner. POSSIBLE CAUSE 1. Manual shutoff valve not fully open. 2. Control knob not fully pressed in. 3 . Control knob not pressed in long enough. 4. Safety inte ...

  • Desa CGB35N - page 28

    28 100351 TROUBLE- SHOOTING Continued OBSERVED PROBLEM Burner backfiring during combustion. Yellow flame during burner combustion. Slight smoke or odor during initial operation. Burner fails to re- spond to thermostat. Heater produces a whistling noise when burner is lit. POSSIBLE CAUSE 1 . Burner orifice is clogged or damaged. 2. Burner damaged. 3 ...

  • Desa CGB35N - page 29

    29 100351 TROUBLE- SHOOTING Continued If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s phone. Follow the gas supplier ’ s instructions. • If you cannot reach your gas supplie ...

  • Desa CGB35N - page 30

    30 100351 SER VICE PROCEDURES Removing Control Valve and Burner Tube 1. Shut off gas supply to heater. 2. Remove lower front access panel on heater. 3. Disconnect burner tube from orifice holder (see Figure 22). 4. Remove pilot gas line from control valve (see Figure 22). 5. Disconnect wire connec- tors from thermocouple interrupter (see Figure 22) ...

  • Desa CGB35N - page 31

    31 100351 SER VICE PROCEDURES Continued Removing Burner 1. Shut off gas supply to heater. 2. Remove lower front access panel on heater. 3. Disconnect burner tube from orifice holder (see Figure 23). 4. Remove orifice holder from burner (see Figure 23). 5. Remove pilot burner bracket nuts and remove pilot assembly (see Figure 23). 6. Move burner to ...

  • Desa CGB35N - page 32

    32 100351 SER VICE PROCEDURES Continued Changing Burner Orifice 1. Shut off gas supply to heater. 2. Remove lower front access panel on heater. 3. Disconnect burner tube from orifice holder (see Figure 24). 4. Remove orifice holder from burner (see Figure 24). 5. Use socket or open-end wrench to remove the old orifice from the orifice holder. 6. Cl ...

  • Desa CGB35N - page 33

    33 100351 TECHNICAL SER VICE You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-323- 5190. 35,000 BTU/Hr 50,000 BTU/Hr Model Model BTU 35,000 50,000 Type Gas Natural Only Natural Only Ignition Piezo Piezo Pressure Regulator Setting 3.5" W ...

  • Desa CGB35N - page 34

    34 100351 Note: Use only original replacement parts. This will protect your warranty cover- age for parts replaced under warranty. Parts Under Warranty Contact your nearest dealer or call DESA International’s Technical Service De- partment at 1-800-323-5190. When calling DESA International, have ready • your name • your address • model numb ...

  • Desa CGB35N - page 35

    35 100351 ACCESSORIES BLOWER KIT - PART NUMBER GA6010 For all models. Provides better heat distribution. Makes heater more efficient. Complete installation and operating instructions provided with blower. Purchase these heater accessories from your local dealer. If they can not supply these accessories, either contact your nearest Parts Central (se ...

  • Desa CGB35N - page 36

    36 100351 ILLUSTRA TED P ARTS LIST Burner Assembly 3 4 8 10 11 1 2 5 6 7 9 12 13 14 15 16 17 18 19 28 27 7 35 Model 6 50 Model 11 24-2 20 21 23 26 22 17 16 4 24 24-1 24-3 24-4 25 7 ...

  • Desa CGB35N - page 37

    37 100351 P ARTS LIST Burner Assembly This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Ordering Replacement Parts on page 34 of this manual. KEY PART NUMBER FOR NO. CGB50N CGB35N DESCRIPTION QTY. 1 100206-02 100206-01 Combustion Chamber 1 2 098324-02 098324-02 Control Knob 1 3 09715 ...

  • Desa CGB35N - page 38

    38 100351 ILLUSTRA TED P ARTS LIST Cabinet Assembly This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Ordering Replacement Parts on page 34 of this manual. 1 2 3 4 5 6 6 7 8 11 6 10 9 PART NUMBER FOR KEY NO. CGB50N CGB35N DESCRIPTION QTY. 1 100202-02 100202-01 Lower Front Panel 1 2 0 ...

  • Desa CGB35N - page 39

    39 100351 NOTES _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ _________________________________________________________________ ____ ...

  • Desa CGB35N - page 40

    40 100351 LIMITED WARRANTY COMFORT GLOW VENTED NATURAL GAS HEATERS LIMITED ONE YEAR WARRANTY This DESA product is warranted to the original purchaser to be free from defect in material and workmanship under normal use and maintenance for a period of one year from the date of installation whether or not actual use begins on that date. It is the resp ...

Fabricante Desa Categoría Electric Heater

Los documentos del dispositivo Desa CGB35N que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Desa
- manuales de instrucciones CGB35N
- hojas de producto Desa
- folletos informativos
- o etiquetas energéticas Desa CGB35N
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Desa CGB35N.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Desa CGB35N, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Desa CGB35N. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Desa CGB35N.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Desa CGB35N, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Desa CGB35N. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Desa CGB35N.

El manual de instrucciones completo de Desa debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Desa CGB35N - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Desa CGB35N, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Desa CGB35N que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Desa CGB35N - que deben facilitarnos los primeros pasos durante el uso de Desa CGB35N
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Desa CGB35N
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Desa CGB35N en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Desa CGB35N?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Desa CGB35N, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Desa CGB35N probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)