  • Iomega px12-350r - page 1

    IOMEGA ® STORCENTER ™ px12-350r STORAGE PROVISIONING AND RAID MIGRA TION CONFIGURA TION GUIDE WHITE PAPER JUNE 2010 INTRODUCTION 1 AUDIENCE 1 TERMINOLOGY 1 STORAGE PROVISIONING 3 Listing Storage Pools 4 Managing Storage Pools 6 Adding Storage Pools 7 Adding folders 12 Adding iSCSI drives 14 RAID MIGRA TION 15 RAID migration by adding more drives ...

  • Iomega px12-350r - page 2

    IOMEGA STORAGE PROVISIONING AND RAID MIGRA TION CONFIGURA TION GUIDE 1 INTRODUCTION The Iomega ® StorC enter ™ px12-350r network storage array offers versatile storage provisioning, advanced protocol capabilities, expandability and affordability in an easy-to-use product ideal for small business, workgroups and departments. Based on enterprise-c ...

  • Iomega px12-350r - page 3

    IOMEGA STORAGE PROVISIONING AND RAID MIGRA TION CONFIGURA TION GUIDE 2 RAID 0: this RAID level distributes data across multiple disks in a way that gives improved speed at any given instance. If one disk fails, however , all the data on the array will be lost, as there is neither parity nor mirroring. RAID 0 is non-redundant. A RAID 0 array require ...

  • Iomega px12-350r - page 4

    IOMEGA STORAGE PROVISIONING AND RAID MIGRA TION CONFIGURA TION GUIDE 3 LUN: Logical Unit Number . Identifying number of a SCSI or iSCSI object that processes SCSI commands. The LUN is the last part of the SCSI address for a SCSI object. The LUN is an ID for the logical unit, but the term is often used to refer to the logical unit itself. Storage Po ...

  • Iomega px12-350r - page 5

    IOMEGA STORAGE PROVISIONING AND RAID MIGRA TION CONFIGURA TION GUIDE 4 Listing Storage Pools 1. T o view Storage Pools, go to Settings > Storage Pools. 2. The Iomega px12-350r supports up to 12 SA T A disks. The drives and their layout inside the device enclosure are shown in a graphical representation. Each drive is numbered. Figure 1 Storage P ...

  • Iomega px12-350r - page 6

    IOMEGA STORAGE PROVISIONING AND RAID MIGRA TION CONFIGURA TION GUIDE 5 White Paper 4. Each hard drive contains a small amount of on-disk write cache. Using the write cache can help improve write performance in some cases. However , data integrity may be at risk when the device loses power in the middle of I/O, yet cached data has not been committed ...

  • Iomega px12-350r - page 7

    IOMEGA STORAGE PROVISIONING AND RAID MIGRA TION CONFIGURA TION GUIDE 6 White Paper Managing Storage Pools The StorC enter px12-350r is ordered and shipped with four drives. By default, one Storage Pool is created using all four drives in the RAID 5 protection mode as shown below . Additional drives can be ordered in expansion packs but will not be ...

  • Iomega px12-350r - page 8

    IOMEGA STORAGE PROVISIONING AND RAID MIGRA TION CONFIGURA TION GUIDE 7 White Paper Adding Storage Pools F or illustration purpose, the default initial Storage Pool is removed so that all twelve drives are available for Storage Pool creation to demonstrate the flexible provisioning options. 1. Go to Settings > Storage Pools and click the icon to ...

  • Iomega px12-350r - page 9

    IOMEGA STORAGE PROVISIONING AND RAID MIGRA TION CONFIGURA TION GUIDE 8 White Paper 3. Choose a RAID level for the Protection type. On the Iomega px12-350r , the following data protection types are available in the Protection selection box. Figure 8 Choose data protection type t Double Parity (RAID 6) – the pool must contain at least 4 drives. t P ...

  • Iomega px12-350r - page 10

    IOMEGA STORAGE PROVISIONING AND RAID MIGRA TION CONFIGURA TION GUIDE 9 White Paper Level RAID 0 RAID 1 RAID 10 Description Striped set without parity or Striping. Provides improved performance and additional storage but no redundancy or fault tolerance. Because there is no redundancy , this level is not actually a Redundant Array of Inexpensive Dis ...

  • Iomega px12-350r - page 11

    IOMEGA STORAGE PROVISIONING AND RAID MIGRA TION CONFIGURA TION GUIDE Level RAID 5 RAID 6 Description Striped set with distributed parity or interleave parity . Distributed parity requires all drives but one to be present to operate; drive failure requires replacement, but the array is not destroyed by a single drive failure. Upon drive failure, any ...

  • Iomega px12-350r - page 12

    IOMEGA STORAGE PROVISIONING AND RAID MIGRA TION CONFIGURA TION GUIDE 11 White Paper 4. There could be three checkboxes associated with Storage Pool creation. t By default, C reate commonly used folders is checked to automatically create the Backups folder , Pictures folder , and Documents folder in the Storage Pool. If the checkbox is unchecked, no ...

  • Iomega px12-350r - page 13

    IOMEGA STORAGE PROVISIONING AND RAID MIGRA TION CONFIGURA TION GUIDE 12 White Paper 6. Repeat the steps to create more Storage Pools. Figure 10 C reate more Storage Pools Adding folders After the Storage Pools finish RAID construction, you can add folders as shared storage for multiprotocol access. Each folder is a directory in the file system that ...

  • Iomega px12-350r - page 14

    IOMEGA STORAGE PROVISIONING AND RAID MIGRA TION CONFIGURA TION GUIDE 13 White Paper 2. Select F older as Shared Storage T ype, enter a name for the folder , and select which Storage Pool to create the folder in. Figure 12 C reate a folder 3. By default the Enable security box is checked to allow you to specify access controls to the folder . Securi ...

  • Iomega px12-350r - page 15

    IOMEGA STORAGE PROVISIONING AND RAID MIGRA TION CONFIGURA TION GUIDE 14 White Paper Adding iSCSI drives The iSCSI service must be enabled before iSCSI drives can be created. Refer to the C onfiguring iSCSI on the Iomega StorC enter Pro ix4-200r NAS Server (http://download.iomega.com/com/nas/pdfs/iscsi_200r_wp_0909.pdf ) white paper about how to con ...

  • Iomega px12-350r - page 16

    IOMEGA STORAGE PROVISIONING AND RAID MIGRA TION CONFIGURA TION GUIDE 15 White Paper 5. After the drive is created, it is listed in the Shared Storage table without information about Used/Available. Figure 15 List iSCSI drives RAID MIGRA TION Storage pools with certain RAID types can be migrated by adding additional drives while data is online. Afte ...

  • Iomega px12-350r - page 17

    IOMEGA STORAGE PROVISIONING AND RAID MIGRA TION CONFIGURA TION GUIDE 16 White Paper RAID migration by adding more drives The procedures for migrating RAID 5 and RAID 6 Storage Pools by adding new drives are the same. In this paper , RAID 5 migration procedure is described. 1. Go to Settings > Storage Pools and click to migrate a RAID 5 Storage P ...

  • Iomega px12-350r - page 18

    IOMEGA STORAGE PROVISIONING AND RAID MIGRA TION CONFIGURA TION GUIDE 17 White Paper 3. Leave the protection type as Parity (RAID 5) and click Apply . The Storage Pool is shown as being reconstructed. Figure 18 Storage pool reconstruction Storage pools with certain RAID types can also be migrated to certain other RAID types by adding additional driv ...

  • Iomega px12-350r - page 19

    IOMEGA STORAGE PROVISIONING AND RAID MIGRA TION CONFIGURA TION GUIDE 18 White Paper 3. Change the data protection type from Mirror (RAID 10) to Parity (RAID 5) and click Apply . The Storage Pool will be reconstructed into the new RAID type. Figure 19 RAID 1 migration to RAID 5 RAID 5 migration to RAID 6 1. Go to Settings > Storage Pools and clic ...

  • Iomega px12-350r - page 20

    IOMEGA STORAGE PROVISIONING AND RAID MIGRA TION CONFIGURA TION GUIDE CONCLUSION The Iomega StorC enter px12-350r network storage array is a high-performance, easy-to-use, and highly reliable storage device, specifically designed to meet the storage challenges that small- and medium-sized businesses face daily . The Iomega px12-350r allows flexible ...

Fabricante Iomega Categoría Server

Los documentos del dispositivo Iomega px12-350r que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Iomega
- manuales de instrucciones px12-350r
- hojas de producto Iomega
- folletos informativos
- o etiquetas energéticas Iomega px12-350r
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Iomega px12-350r.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Iomega px12-350r, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Iomega px12-350r. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Iomega px12-350r.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Iomega px12-350r, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Iomega px12-350r. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Iomega px12-350r.

El manual de instrucciones completo de Iomega debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Iomega px12-350r - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Iomega px12-350r, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Iomega px12-350r que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Iomega px12-350r - que deben facilitarnos los primeros pasos durante el uso de Iomega px12-350r
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Iomega px12-350r
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Iomega px12-350r en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Iomega px12-350r?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Iomega px12-350r, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Iomega px12-350r probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)