Manual de instrucciones Linak MEDLINE MJB

24 de páginas 0.23 mb
Descargar

Pasar a la página of 24

Summary
  • Linak MEDLINE MJB - page 1

    T o learn more about LINAK please visit: WWW .LINAK.COM MJB - Gateway USER MANUAL ...

  • Linak MEDLINE MJB - page 2

    2 ...

  • Linak MEDLINE MJB - page 3

    Contents Preface .............................................................................................................................. .................................... 4 Important information .............................................................................................................................. .......... 5 Safet ...

  • Linak MEDLINE MJB - page 4

    Pr eface We ar e delighted that you have chosen a product fr om LINAK ® . LINAK systems are high-tech pr oducts based on many years of experience in the manufacture and development of actuators, electric contr ol boxes, controls and chargers. This User Manual will tell you how to install, use and maintain your LINAK equipment. We ar e sure that yo ...

  • Linak MEDLINE MJB - page 5

    5 Safety instructions Safe use of the system is possible only when the operating instructions are r ead completely and the instructions contained are strictly observed. Failure to comply with instructions marked with the”NOTE” symbol may r esult in serious damage to the system or one of its components. Persons who do not have the necessary expe ...

  • Linak MEDLINE MJB - page 6

    Residual risk Some of the products contains softwar e based components. LINAK has made various possible efforts to assur e that the software is fr ee of errors and that the software has been developed accor ding to the rules of IEC 60601-1-4 (software in Medical pr oducts). That involves Risk Analysis which shows a small residual risk for unwanted/ ...

  • Linak MEDLINE MJB - page 7

    7 Before installation, r e-installation, or troubleshooting • Stop the application • Switch off the power supply and pull out the mains plug. • Relieve the application of any loads, which may be released during the work. Before start-up • Make sure that the system has been installed as instructed in the User Manual. • Make sure that the v ...

  • Linak MEDLINE MJB - page 8

    8 Repairs In order to avoid the risk of malfunction, all r epairs must only be carried out by authorised LINAK workshops or repair ers, as special tools must be used and special gaskets must be fi tted. Products under warranty must also be r etur ned to authorised LINAK workshops. W ar ning! If any of the LINAK products ar e opened, there will be ...

  • Linak MEDLINE MJB - page 9

    9 Misc. on the MJB system W arranty and service life The LINAK warranty covers manufacturing defects in the pr oducts, starting from the date of manufacture. Ther e is 18 months’ warranty for MEDLINE and CARELINE products. The warranty is limited to the value of the LINAK pr oduct. LINAK’ s guarantee is only valid so far as the products have be ...

  • Linak MEDLINE MJB - page 10

    10 MJB - GA TEW A Y variant, 504-01 & 504-02 : The MJB is a simple gateway interface, which can connect the bed to the infrastructure of the hospital or nursing homes. The Gateway can be used in combination with an Out of Bed Sensor , which makes it possible to indicate if the patient leaves the bed. The Gateway can also be used as a service/nu ...

  • Linak MEDLINE MJB - page 11

    11 Features: • Add-on value for hospital & care bed • Compact and functional design which allows easy mounting • 2 connections, Port1 OpenBus™ connection / Port 5 Gateway • Colour: Light grey RAL 7035 • Protection class IPX6 • Connection to OpenBus™ control box via modular plug cable, 6 wir es • Modular plug to Open end, see p ...

  • Linak MEDLINE MJB - page 12

    12 Relay 1 CB power mode Alarm level Relay state Mains unplugged, CB is in power down or the OpenBus™ is not running (Clock/ data is missing) Alarm NC* On mains or battery at “wake up” Bed Alarm** NC No Alarm NO Relay 2 CB power mode Alarm level Relay state Mains unplugged or CB is in power down No Alarm NC On mains or battery at “wake up ...

  • Linak MEDLINE MJB - page 13

    13 Precautions: • Always use locking mechanism and O-ring • Sockets not used must be fi tted with blind plugs to ensure IP Degr ee • When using the modular plug with open end, is it up to the customer to maintain the IP degree. • If the MJB – Gateway is used as open loop, there is a risk of not sending an alarm, when no mains are connect ...

  • Linak MEDLINE MJB - page 14

    14 Cable ordering nos.: Modular plug – open end: 0964140-3000 Please note, the slit is placed on the opposite side of the modular plug. This is to ensure that the cable is only being used for the Gateway MJB. ...

  • Linak MEDLINE MJB - page 15

    15 IP Protection Cleaning instrucions IPX0 Clean with a damp cloth IPX1 Clean with a damp cloth IPX2 Clean with a damp cloth IPX3 Clean with a damp cloth IPX4 Clean with a damp cloth IPX5 W ash with a brush and water , but not water under pressur e IPX6 X W ash with a brush and water . The water can be under pressur e, but the system must not be ho ...

  • Linak MEDLINE MJB - page 16

    16 W ar ning! The systems must not be sprayed directly with a high-pr essure cleaner . W ar ning! Interconnecting cables must r emain plugged in during cleaning to prevent the ingress of water . Precaution! When cleaned, water must never be sprayed upwar ds from underneath the bed, because it may enter the cable outlet. Envir onmental conditions: E ...

  • Linak MEDLINE MJB - page 17

    17 Modular plug with wide slit T o be used with LINAK products. Can be connected to all ports in the MJB, both ports with narrow and wide slit. Modular plug with narr ow slit T o be used with 3 rd party products. Can only be connected to ports in the MJB with narrow slit. This is to pr event 3 rd party products to interfere with the OpenBus TM conn ...

  • Linak MEDLINE MJB - page 18

    18 T ype B equipment, as per EN 60601-1 Protection against contact/foreign matter (first character) and water (second character) as per EN60529 Class 2 equipment For indoor use Double insulated transformer Protective earth Alter nating Curr ent Direct curr ent Attention, consult accompanying documents Key to symbols Lock function Release function C ...

  • Linak MEDLINE MJB - page 19

    19 Demko approval Fimko approval Australian approval mark Australian approval mark Recognised - Component Mark Canadian Recognised - Component Mark Recognised Component Mark for Canada and the United States T -Mark RW-Tüv approval Tüv .Produkt Service TÜVRheinland ETL C-ETL LGA UL Listing Mark C-UL Listing Mark C-UL US Listing Mark UL Listing Ma ...

  • Linak MEDLINE MJB - page 20

    20 MJB MJB - Modular Junction Box DRA WING APPENDIX MJB ...

  • Linak MEDLINE MJB - page 21

    21 LINAK APPLICA TION POLICY The purpose of the application policy is to defi ne areas of r esponsibilities in relation to applying a LINAK product defi ned as har dware, softwar e, technical advice, etc. related to an existing or new customer application. LINAK products as defi ned above ar e applicable for a wide range of applications within t ...

  • Linak MEDLINE MJB - page 22

    22 ...

  • Linak MEDLINE MJB - page 23

    23 ...

  • Linak MEDLINE MJB - page 24

    Copyright © LINAK 2010.10 MA-M9-02-348 LINAK A/S reserve the right to make technical alterations T erms of use The user is responsible for determining the suitability of LINAK products for specifi c application. LINAK takes great care in providing accurate and up-to-date information on its products. However , due to continuous development in orde ...

Fabricante Linak Categoría Network Router

Los documentos del dispositivo Linak MEDLINE MJB que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Linak
- manuales de instrucciones MEDLINE MJB
- hojas de producto Linak
- folletos informativos
- o etiquetas energéticas Linak MEDLINE MJB
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Linak MEDLINE MJB.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Linak MEDLINE MJB, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Linak MEDLINE MJB. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Linak MEDLINE MJB.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Linak MEDLINE MJB, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Linak MEDLINE MJB. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Linak MEDLINE MJB.

El manual de instrucciones completo de Linak debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Linak MEDLINE MJB - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Linak MEDLINE MJB, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Linak MEDLINE MJB que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Linak MEDLINE MJB - que deben facilitarnos los primeros pasos durante el uso de Linak MEDLINE MJB
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Linak MEDLINE MJB
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Linak MEDLINE MJB en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Linak MEDLINE MJB?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Linak MEDLINE MJB, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Linak MEDLINE MJB probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)