Manual de instrucciones Omnitron Systems Technology A10

25 de páginas 0.54 mb
Descargar

Pasar a la página of 25

Summary
  • Omnitron Systems Technology A10 - page 1

    SCAN A10 INSTRUCTIONS FOR INSTALLATION AND USE Te s t e d & Li s t e d b y B e av er t o n O r e gon U S A O MN I - Te s t La b ora t ori e s , I n c . Save these instructions February 2003 KROG IVERSEN & CO. A/S - 5492 VISSENBJERG - DENMARK Table of Contents: ...

  • Omnitron Systems Technology A10 - page 2

    2 1. INTRODUCTION.................................. ............................................. ................................. ............................................. 3 Safety and environment al testing. ..................... ......................................................................... .... .................................. ...

  • Omnitron Systems Technology A10 - page 3

    3 We welcome you as a new owner of a SCAN A10 wood-burning stove. In purchasing a SCAN stove you have joined the growing ranks of concerned in dividuals whose selection of energy systems reflects both a conce rn for the environment and aest hetics. The SCAN stove is one of th e finest home wood stoves in the world over. This manual will explain the ...

  • Omnitron Systems Technology A10 - page 4

    4 SAFETY PRECAUTIONS KEEP THE START DEVI CE CLOSED DURING FIRING I N THIS STOVE. THE START DEVICE MAY BE OPENED FOR A MAXIMUM OF 5 MINUTES DURING START-UP. USE A METAL CONTAINER WI TH A TIGHT FITTING LID TO DISPOSE OF ASHES. NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR SI MILAR LIQUIDS TO START OR “FRESHEN ...

  • Omnitron Systems Technology A10 - page 5

    5 2. INSTALLATION Precaution If your SCAN A10 stove is not properly installed, operated and main tained, a house fire may result. For your safety, follow all installation, ope ration and maintenance directions. Contact your local building officials about restrictions and installation requirements in your area. Pre Installation Check List: Before yo ...

  • Omnitron Systems Technology A10 - page 6

    6 NOTE: The clearances expressed in inches are those approved for installation in the United States. The clearances in expressed in millimeters are those approved for installations in Canada. Different test standards for the respective co untries may result in differences in the clearan ce requirements. The Floor One of the main necessary precautio ...

  • Omnitron Systems Technology A10 - page 7

    7 Corner installation Floor protection for Corner Installation A B C D USA 16" 4” 69 5/8” 98 ½” Canada 457 1840 2602 In a rear vent installation the floor protection must also extend under th e stovepipe a minimum of 2” (50mm) beyond eithe r side of the pipe. Ceiling H eight: Do not install in an alcove or confined space and do not in ...

  • Omnitron Systems Technology A10 - page 8

    8 Combustible Wall Cl earance for Top Vent Installation If the stove is to be placed at side and back walls of combustible materials the following clearances must be kept Parallel installation Corner install ation Parallel installation Connector pipe A B C D USA Single wall 13” 9.5” 21” 11” Canada Single wall 406 317 533 279 Corner installa ...

  • Omnitron Systems Technology A10 - page 9

    9 Combustible Wall Cl earance for Rear Vent Installation If the stove is to be placed at side and back walls of combustible materials the following clearances must be kept: Refer to the manufac turer’s instructions concerning installation of lis ted single wall connector pipe, wall thimble and chimney Alcove Installation Requirements: Whenever th ...

  • Omnitron Systems Technology A10 - page 10

    10 Mobile Ho me Installation : US only In addition to standard installation the following requirements are mandatory for installation in a mobile home. The stove must be permanently bolted to the floor of the mobile home using the floor screws provided. Note: If the composition of the manufactured (m obile) home floor is of light particleboard cons ...

  • Omnitron Systems Technology A10 - page 11

    11 Outside air requirements Required for mobile home and in certain localities (Check with buildin g officials) Outside air must not be drawn from an enclosed space (garage or o ther unventilated spaces) When using o utside air, find a location where the chimney and outside air hole do not interfere with str uctural m embers of the hom e. Connect a ...

  • Omnitron Systems Technology A10 - page 12

    12 Chimney Installa tion: Do not connect this unit to a chimney flue servi ng another appliance. Do not connect to any air distribution duct or system . The SCAN A10 stove is listed for in stallation as a ve rtically top or rear vented stove using a listed class A (UL103HT) for Canada (CAN/ULC-S629) fa ctory built chimney exiting through the ceilin ...

  • Omnitron Systems Technology A10 - page 13

    13 Chimney Conn ection The chimney connector is ether a sin gle or doubl e walled pipe, depending on the type of installation, used to conne ct the stove to the chimney. For use with the SCAN woodstoves the c himney connector MUST b e 6” in diameter, with a mi nimum thickness of 24 gauge black steel or 26 gauge blued steel. Aluminium and galvaniz ...

  • Omnitron Systems Technology A10 - page 14

    14 Rear Vent Installation For venting into a masonry or a bac k standing steel chimney through the top vent the top horizontal portion of a single wall connector pipe ca n be located not closer than 18” below a combustib le ceiling. From the factory the stove is pre pared for top moun ting of the flue collar, but all SCAN stoves have an optional ...

  • Omnitron Systems Technology A10 - page 15

    15 Combustible Wall Chi mney Connector Pass-Throughs. Method A. 12” (304.8 mm) Cleara nce to Combustible Wall Member : Using a minimum thickne ss 3.5” (89 mm) brick and a 5/8” (15.9 mm) minimum w all th ickness clay line r, construct a wall pa ss-through. The clay liner must conform to ASTM C315 (Standard Specification for Clay Fire Linings) ...

  • Omnitron Systems Technology A10 - page 16

    16 NOTES: 1. Connectors to a masonry chimney, ex cepting method B, shall extend in one continuous section through the wa ll pass-th rough sy stem and the chimney wall, to but not past the inner flue liner face. 2. A chimney connector shall not pass through an attic or roof space, closet or similar concealed space, or a floor, or ceiling. Chimney he ...

  • Omnitron Systems Technology A10 - page 17

    17 3. INSTRUCTIONS FOR USE Ash Drawer The ash drawer located behind the fuel door is designed to make cleaning easier by c ontaining the ashes in a removable drawer Ash Grate Above the ash drawer, locat ed in the floor of the firebox is a rotating ash grate to facilitate transferring ashes from the fireb ox into the ash drawer. To operate this grat ...

  • Omnitron Systems Technology A10 - page 18

    18 Ceramic Packing Cord These stoves are equipped with a ceramic packing co rd to ensure the tightness of the doors and the glasses. This packin g cord is a wearing part an d must be changed from time to time. Please con sult your authorized dealer in this case. Protected Wall Reduced Clearances Local codes in some areas will allow reduced clearanc ...

  • Omnitron Systems Technology A10 - page 19

    19 Starting a Fire: Do not elevate the fire. Build fire directly on the hearth inside the stove; do not build fire above or in front of the log retainer. To start a fire: Pull the start device and air intake control to fully open. In addition, to help with the start-up, you may also leave the fuel doo r slightly ajar. Use a sm all amount of fire st ...

  • Omnitron Systems Technology A10 - page 20

    20 Removing Baffle for Cleaning Be sure the fire is out and the stove is cold befor e removing baffle plate. Be cautions with handling the plates becau se the plates are made of a delicate material; which easily broke if not handle with care. Removal of the lower plate: lift the plate (pos 1) u p from the supporting pi ns (pos 4) and take the pins ...

  • Omnitron Systems Technology A10 - page 21

    21 Air Tube removal: Remove the screw (pos.1) on the left air tube collar (pos.3). Slide the air tube (pos.2) to the right, swing it down and remove it. Replacement Part List SCAN A10 Caution: Use only original SCAN A10 replacement part. Do not use subs titute materials. Replacement part Part # Glass panel for the door 57811011 Gasket for the glass ...

  • Omnitron Systems Technology A10 - page 22

    22 Creosote Formation and the Need for Removal When wood is burned slowly it produces tar and other organic vapors, wh ich combine with expelled moisture to form creosote. The creos ote vapors condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote res idue accum ulates in the flue lining. When ignited this creoso ...

  • Omnitron Systems Technology A10 - page 23

    23 6. TROUBLESHOOTING Smoke: - Insufficient chimney draught! - Check if the chimney has the right dimension. - Check if the smoke pipe or chimney is blocked. - Check if the chimney has the right height compared to the surroundings . - Wood with excessive moisture content. The wood burns too fast: - Are the air valves adjusted correctly according to ...

  • Omnitron Systems Technology A10 - page 24

    24 7. WARRANTY CONDITIONS FOR SCAN WOOD BURNING PRODUCTS All SCAN wood stoves, in serts and fireplaces are subject to a s trict quality control, before they are shipped to the customer and end user. However, s hould an error occur, we back all SCAN wood burning stoves, inserts, and fireplaces with an extensive five y ears limited wa rranty. The war ...

  • Omnitron Systems Technology A10 - page 25

    25 8. EPA Sticker ...

Fabricante Omnitron Systems Technology Categoría Stove

Los documentos del dispositivo Omnitron Systems Technology A10 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Omnitron Systems Technology
- manuales de instrucciones A10
- hojas de producto Omnitron Systems Technology
- folletos informativos
- o etiquetas energéticas Omnitron Systems Technology A10
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Omnitron Systems Technology A10.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Omnitron Systems Technology A10, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Omnitron Systems Technology A10. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Omnitron Systems Technology A10.

El manual de instrucciones del dispositivo Omnitron Systems Technology A10, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Omnitron Systems Technology A10. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Omnitron Systems Technology A10.

El manual de instrucciones completo de Omnitron Systems Technology debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Omnitron Systems Technology A10 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Omnitron Systems Technology A10, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Omnitron Systems Technology A10 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Omnitron Systems Technology A10 - que deben facilitarnos los primeros pasos durante el uso de Omnitron Systems Technology A10
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Omnitron Systems Technology A10
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Omnitron Systems Technology A10 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Omnitron Systems Technology A10?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Omnitron Systems Technology A10, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Omnitron Systems Technology A10 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)