    Use, Care, and Installation Guide www .zephyronline.com Model number: Serial Number: FEB09.0201 © Zephyr Corporation Milano W all ZMI-M90AS ZMI-M90AG ...

  • Zephyr ZMI-M90AS - page 2

    www .zephyronline.com ...

  • Zephyr ZMI-M90AS - page 3

    1 SAFETY NOTICE ................................................................. 2-3 LIST OF MA TERIALS ....................................................... 4 INST ALLA TION Ducting Calculation Sheet ....................................... 5 Mounting Height & Clearance ................................ 6 Ducting Options ..................... ...

  • Zephyr ZMI-M90AS - page 4

    Important Safety Notice READ AND SA VE THESE INSTRUCTIONS 2 www .zephyronline.com W ARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS F AN WITH ANY SOLID-ST A TE CONTROL DEVICE. W ARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSER VE THE FOLLOWING: a. Use this unit only in the manner intended by the man ...

  • Zephyr ZMI-M90AS - page 5

    Important Safety Notice 3 W ARNING TO REDUCE THE RISK OF FIRE, USE ONL Y MET AL DUCTWORK. CAUTION T o reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. OPERA TION Always leave safety grilles and fi lters in place. Without these components, operat ...

  • Zephyr ZMI-M90AS - page 6

    List of Materials 4 www .zephyronline.com (3) Wire Nuts (3) M4 x 1-1/2” (2) M4 x 1” (4) 3/16” x 8 (4) M3.5 x 8 P ARTS NOT SUPPLIED - Ducting, conduit and all installation tools - Cable connector (if required by local codes) - Duct cover extension accessory - Z1C-00MI - Recirculating kit accessory - ZRC-0040 HARDW ARE P ACKAGE CONTENTS MODELS: ...

  • Zephyr ZMI-M90AS - page 7

    5 Duct pieces To t a l Equivalent number length x used = 3- 1/ 4” x 10” Rect., straight 1 Ft. x ( ) = Ft. 8” Round, straight 1 Ft. x ( ) = Ft. 3- 1/ 4” x 10” Rect. 90 0 elb ow 15 Ft. x ( ) = Ft. 3- 1/ 4” x 10” Rect. 45 0 elb ow 9 Ft. x ( ) = Ft. 3- 1/ 4” x 10” Rect. 90 0 flat elb ow 24 Ft. x ( ) = Ft. 3- 1/ 4” x 10” Rect. wall ...

  • Zephyr ZMI-M90AS - page 8

    Installation – Mounting Height & Clearance 6 www .zephyronline.com DUCTING A minimum of 6” round duct must be used to maintain maximum air fl ow ef fi ciency . Always use rigid type metal ducts only . Flexible ducts could restrict air fl ow by up to 50%. Use calculation worksheet to compute total duct work (Page 5). AL WA YS, when possib ...

  • Zephyr ZMI-M90AS - page 9

    7 W ARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only . Fasten all connections with sheet metal screws and tape all joints w/ certi fi ed Silver T ...

  • Zephyr ZMI-M90AS - page 10

    8 www .zephyronline.com Installation – Hood Speci fi cations 23 15/16” min. ducted - 26 1/2” min. recirc. - 30” max. - 49” 10 1/2” elec. k/o 4” 8 1/2” 35 7/16” 14” 20 1/2” 6” Ø top of hood front of hood side of hood ...

  • Zephyr ZMI-M90AS - page 11

    9 1. Measure from range top to hood bottom and mark line A. (28” minimum from range top) . 2. Plum and mark center line. 3. Mark mounting height line B. (15-3/8” from line A) 4. Mark mounting spread from C/L. (8-7/8”) 5. Fasten (2) M4 x 1-1/2” screws into studs on line B but do not tighten all the way . Note: Wood blocking may need to be ad ...

  • Zephyr ZMI-M90AS - page 12

    10 www .zephyronline.com (blower housing) Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and fi ltered by a set of optional charcoal fi lters. The air is ...

  • Zephyr ZMI-M90AS - page 13

    11 Lights On/Dim/Off 15 Min Delay Off Display (speed level, delay off, filter clean/change) Adjust 6 Speed Levels Blower On/Off 1. Blower On/Off By pressing the blower is switched on and off. When switched on, the blower starts up on speed level 3. 2. Speed Selection The 6 speed levels are selected by pressing to decrease and to increase speed leve ...

  • Zephyr ZMI-M90AS - page 14

    Features & Controls – Charcoal Filter Change Reminder 12 www .zephyronline.com Charcoal Filter Change Reminder (charcoal filter , if installed) When your hood is installed as a recirculating unit, it is fitted with a set of charcoal filters to purify exhaust and fumes from cooking, then re-circulates the air within the home. These charcoal fi ...

  • Zephyr ZMI-M90AS - page 15

    Features & Controls – Metal Mesh Filter Clean Reminder 13 Metal Filter Clean Reminder (metal mesh filter) Whether your hood is installed as an exhaust or purifying unit, a set if metal mesh filters are fitted by the factory , These metal mesh filters are intended to filter out residue from cooking. They need not be replaced on a regular basis ...

  • Zephyr ZMI-M90AS - page 16

    14 www .zephyronline.com SURF ACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratch and damage surface. For heavier soil use liquid degreaser . After cleaning it is recommended that you use non-abrasive stainless steel polish/clean ...

  • Zephyr ZMI-M90AS - page 17

    Maintenance - Lights 15 of the REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. T ouching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 deg ...

  • Zephyr ZMI-M90AS - page 18

    16 www .zephyronline.com T roubleshooting TROUBLESHOOTING PROCEDURES FOR MILANO W ALL Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly . 2. Check the pow ...

  • Zephyr ZMI-M90AS - page 19

    List of Parts & Accessories 17 DESCRIPTION P ART# Replacement Parts Light Bulb GU-10 50W (each) Z0B-0020 Metal Mesh Filter (each) 5020001 1 Optional Accessories Recirculating Kit ZRC-0040 Replacement Charcoal Filter Z0F-C002 Duct Cover Extension Z1C-00MI T o order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8 ...

  • Zephyr ZMI-M90AS - page 20

    1-888-880-8368 STAPLE YOUR RECEIPT HERE TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be fre ...

Fabricante Zephyr Categoría Ventilation Hood

Los documentos del dispositivo Zephyr ZMI-M90AS que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Zephyr
- manuales de instrucciones ZMI-M90AS
- hojas de producto Zephyr
- folletos informativos
- o etiquetas energéticas Zephyr ZMI-M90AS
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Zephyr ZMI-M90AS.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Zephyr ZMI-M90AS, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Zephyr ZMI-M90AS. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Zephyr ZMI-M90AS.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Zephyr ZMI-M90AS, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Zephyr ZMI-M90AS. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Zephyr ZMI-M90AS.

El manual de instrucciones completo de Zephyr debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Zephyr ZMI-M90AS - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Zephyr ZMI-M90AS, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Zephyr ZMI-M90AS que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Zephyr ZMI-M90AS - que deben facilitarnos los primeros pasos durante el uso de Zephyr ZMI-M90AS
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Zephyr ZMI-M90AS
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Zephyr ZMI-M90AS en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Zephyr ZMI-M90AS?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Zephyr ZMI-M90AS, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Zephyr ZMI-M90AS probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)