Manual de instrucciones Graco 3A2587H

32 de páginas 5.91 mb
Descargar

Pasar a la página of 32

Summary
  • Graco 3A2587H - page 1

    3A2587H Operation - Repair - Parts Electric Hand-Held Paint Sprayers - For portable spray applications of ar chitectural paints and coatings only - - Not approved for use in expl osive atmosphere locations - All Models: Maximum Working Pressure 2000 psi (14 MPa, 138 bar) IMPORTANT SAFETY INSTRUCTIONS Read all warnings and in structions in this manu ...

  • Graco 3A2587H - page 2

    Table of Contents 2 3A2587H Table of Contents Important User Information . . . . . . . . . . . . . . . . . . 2 Before using your sprayer re ad this Operation Manual for complete instruction s on proper use and safety warnings. . . . . . . . . . . . . . . . . . . . 2 Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Compon ...

  • Graco 3A2587H - page 3

    Warnings 3A2587H 3 Warnings The following warnings are fo r the setup, use, maintenanc e, and repair of this equipment. The exclamation point symbol alerts you to a general warn ing and the hazard sy mbols refer to procedure-specific risks. Wh en these sym- bols appear in the body of this manual or on war ning labels, refer back to these Warnings. ...

  • Graco 3A2587H - page 4

    Warnings 4 3A2587H FIRE AND EXPLOSION HAZARD Flammable fu mes, such a s solvent an d paint fume s, in work area can ignite or explode. To help prevent fire and expl osion: • Sprayer generates sparks. Do not spray or flush with flammable liqui ds. • Use only water-b ased or oil-based (min eral spirit -type) materials with a flash point greater t ...

  • Graco 3A2587H - page 5

    Warnings 3A2587H 5 EQUIPMENT MI SUSE HAZARD Misuse can cause death or serious injury. • Always wear appropriate gloves, eye pr otection, and a respirator or mask when pa inting. • Do not operate or spray near child ren. Keep children away from equipment at all times. • Do not overreach or stan d on an unstable support. Keep effective footing ...

  • Graco 3A2587H - page 6

    Component Identification 6 3A2587H Component Identification *NOTE: Spray tip filter is reve rse-threaded. Tur n left (or count er-clockwise ) to tighten, turn right (or clockwise) to loosen. H C *B F A K D M N J E R P ti18911a G L S T A Spray Tip/Guard Assembly *B Spray Tip Filter (Reverse Threaded) C Air Vent Valve D Flexibl e Suction Tube E Pump ...

  • Graco 3A2587H - page 7

    Using Electrical Cords 3A2587H 7 Using Electrical Cords Grounding and Electrical Requirements This 120 Vac sprayer requ ires a 120 Vac, 60 Hz, 15A circuit with a g rounding receptacle. Never use an outlet th at is not grounded or an adapter. Do not use the sprayer if the electrical cord has a da m- aged ground prong. Power Cord Extension Cord Requi ...

  • Graco 3A2587H - page 8

    Common Procedures 8 3A2587H Common Procedures Trigger Lock Prime/Spray Valve Follow the Pressure Relief Procedure whenever you see this symbol. Pressure Relief Procedure 1. Engage trigger lock. 2. Put prime/spray valve UP to release pressure . Always engage the trigger lo ck when you stop spraying to prevent th e sprayer fr om being trig gered acci ...

  • Graco 3A2587H - page 9

    Common Procedures 3A2587H 9 Reversible Spray Tip In the event that particles or debris clog the spray tip, this sprayer is designed with a reve rsible spray tip that can be used to qu ickly and easily clear th e particles and resume sp raying as qui ckly as po ssible. • Always point the reversible spray tip forward when spraying . • When partic ...

  • Graco 3A2587H - page 10

    Overheating Protection 10 3A2587H Overheating Protection The motor has a built-in fea ture to protect itself from overuse. If the moto r stops , the thermal switch has tripped. Do not return sprayer to store. The motor will operate normally after co oling for 20-30 minu tes. For best results, do not sp ray mo re than one cup of water through the ti ...

  • Graco 3A2587H - page 11

    Starting a New Job (o r Refilling the Materia l Cup) 3A2587H 11 Starting a New Job (or Refilling the Material Cup) 1. Engage trigge r lock and p ut prime/spra y valve UP to release pressure . 2. Install material cup lin er, fill with ma terial, and thread on to sprayer. 3. To fill sprayer with fluid, disengage trigger lock and trigger sprayer for 1 ...

  • Graco 3A2587H - page 12

    Choosing the Correct Tip 12 3A2587H Choosing the Correct Tip Understanding Tip Number The last three digits of tip number (i.e.: X XX515 ) con- tains information about hole size a nd fan width on sur- face when gun is held 12 in. (30.5 cm) from surface being sprayed. Example: For a 10 - 12 in. (254 - 305 mm ) fan width and a 0.015 in (0.38 mm) hole ...

  • Graco 3A2587H - page 13

    Install Spray Tip/Guard Assembly (i f not installed) 3A2587H 13 Install Spray Tip/Guard Assembly (if not installed) 1. Engage trigger lock and put prime/spray valve UP to release pressure. 2. Install spray tip filter to spray tip/guard assembly. NOTE: Spray tip filter is reverse-threaded. Turn left (or counter-clockwise) to install. Turn right (or ...

  • Graco 3A2587H - page 14

    Unclogging Spray Ti p/Guard Assembly 14 3A2587H Aiming Sprayer Aim spray tip of sprayer at bottom edge of previous stroke, overlapping each stroke by half. Spray Pattern Quality A good spray pattern is evenly distributed as it hits the sur- face. Adjust pressure control knob so pressure is just high enough to spray without “tails”. If tails per ...

  • Graco 3A2587H - page 15

    Shutdown and Cleaning 3A2587H 15 Shutdown and Cleaning The motor has a built-in featur e to protect itself from overuse. If the motor stops, the thermal switch has tripped. Do not return sprayer to store. The motor will operate normally after cooling for 20-3 0 minutes. For best results, do not spray more than one cup of water through the tip while ...

  • Graco 3A2587H - page 16

    Shutdown and Cleaning 16 3A2587H 8. Disconnect trigger lock and trigger sprayer for approxi- mately 15 seconds. Engage trigger lock. 9. Discard contaminated fluid and refill with appropriate flushing fluid. 10. Disengage trigger lock, reverse spray tip to UNCLOG position, and pull trigger for 5 seconds to prime sprayer. 11. Put prime/spray valve DO ...

  • Graco 3A2587H - page 17

    Storage 3A2587H 17 Cleaning Sprayer Exterior • Wipe paint off outside of sprayer using a soft cloth moistened with water o r flushing fluid. Do NOT submerge the spr ayer. Do NOT use solv ents with a flash point greater than 100° F (38° C). Storage 1. Lift valve UP to the pr ime position. Remove material cup and flexible suc tion tube. 2. Remove ...

  • Graco 3A2587H - page 18

    Replacement Parts 18 3A2587H Replacement Parts Models 16N658, 16N6 59, 16N673, 17C810 ti19438c 3 51 52 53 23 22 21 20 1 2 54 55 17 16 15 14 13 12 11 19 18 5 6 7 8 9 10 24 25 32 34 50 31 58 30 29 28 27 26 37 33 36 35 40 41 59 32 38 47 42 43 44 45 49 48 45 44 7 60 34 61 ti19438a 23 23 ...

  • Graco 3A2587H - page 19

    Replacement Parts 3A2587H 19 Parts List - Models 16N658, 16N659, 16N673, 17C810 Ref. If you have this model sprayer (model number is the same as the part number, which is below the handle) Order Part Number: Description 1 All models 243103 Pump Armor (32 oz) 2 All models 16M816 Startup/Storage Kit 3 Model 16N673, 17C810 24F078 Storage Case (Not inc ...

  • Graco 3A2587H - page 20

    Replacement Parts 20 3A2587H Parts List - Models 16N658, 16N659, 16N673, 17C810 (Continued) Ref. If you have this model sprayer (model number is the same as the part number, which is below the handle) Order Part Number: Description 28 All models 16M864 Reciprocator Assembl y Kit (includes parts 20, 2 8, 44, 55) 29 All mod els 115263 Motor Mount Scr ...

  • Graco 3A2587H - page 21

    Inlet Valve Fitting Removal/Service 3A2587H 21 Inlet Valve Fitting Removal/Service 1. Engage trigger lock and pull prime/spray valve UP to release pressure. 2. Remove material cup, flexible suction tube, and unplug. 3. Hold sprayer upside-down and use wrench to loosen and remove inlet valve fitting, inlet valve, and spring. NOTE: Make sure the spri ...

  • Graco 3A2587H - page 22

    Outlet Valve Fitting Rep air 22 3A2587H Outlet Valve Fitting Repair NOTE: Before doing any repair to pump, perform Flushing Sprayer procedur e, page 15. Removal 1. Engage t rigger loc k and pull prime/spray valve UP to release pressure. 2. Unplug sp rayer. 3. Remove outlet valve fitting access plug. 4. Use tool (supplied) to loosen an d remove outl ...

  • Graco 3A2587H - page 23

    General Service 3A2587H 23 General Service See manual 3A1884 (available at www.graco.com) for complete instructions on properly servicing your spraye r. If you have opened the sprayer clamshell and do not have access to manual 3A1884, follow the instructions below to reduce the risk of errors when assembling the sprayer clamshell. Wiring Align swit ...

  • Graco 3A2587H - page 24

    Troubleshooting 24 3A2587H Troubleshooting Check everything in this Troubleshooting Table before you bring the sprayer to an authorized service center. This equipment stays pressuriz ed until pressure is manually relieved. To help prevent serious injury from pressurized fluid, such as skin injectio n, splashing fluid and moving parts, follow the Pr ...

  • Graco 3A2587H - page 25

    Troubleshooti ng 3A2587H 25 Spray Pattern Diagnostics Sprayer sprays with poor results Spray tip is partially clogged See Unclogging Spray Tip/Guard Assembly , page 14. Spray tip is not in correct position Rotate spray tip to SPRAY position. Incorrect spray tip for application of material. See Reversible Sp ray Tip Selection Chart, page 12. Spray t ...

  • Graco 3A2587H - page 26

    Troubleshooting 26 3A2587H Spray pattern is too narrow: Sprayer is too close to target surface. Move sprayer away from surface 10 in. (25 cm) Incorrect spray tip for application of mater ial. See Reversible Spray Tip Selection Chart, page 12. Spray tip is worn or damaged. Replace spray tip. See Install Spray Tip/Guard Assembly , page 13. Spray patt ...

  • Graco 3A2587H - page 27

    Troubleshooti ng 3A2587H 27 Troubleshooting Leaks Problem Cause Solution Sprayer is leaking fluid at Points A Spray/tip guard assembly is loose. Tighten spray/tip gua rd assembly. O-ring inside needle assembly is worn out. Replace o-ring (108 195). Sprayer is leaking fluid at Point B O-ring on rear of needle assembly is worn out. Replace o-ring (10 ...

  • Graco 3A2587H - page 28

    Technica l Data 28 3A2587H Technical Data Hand-Held Sprayer ( Models: 16N673, 16N659) U.S. Metric Adjustable Pressure Range 1000 - 2000 psi 7 - 14 MPa, 69 - 138 bar Maximum Amperage 4 Amps 4 Amps Weight 6.04 lb 2.74 kg Dimensions: Length 12.75 in. 32.4 cm Width 5.5 in. 14.0 cm Height 10 .75 in. 27.3 cm Storage Temperature Range  32° to 113° ...

  • Graco 3A2587H - page 29

    Technical Data 3A2587H 29 Hand-Held Sprayer (Model: 16 N658) U.S. Metric Fixed Pressure 1300 psi 9.9 MPa, 89.6 bar Maximum Amperage 4 Amps 4 Amps Weight 6.86 lb (15 ft cord) 3.11 kg (4.6 m cord) Dimensions: Length 12.75 in. 32.4 cm Width 5.5 in. 14.0 cm Height 10. 75 in. 27.3 cm Storage Temperature Range  32° to 113° F 0° to 45° C Operati ...

  • Graco 3A2587H - page 30

    Preferred Material Settings Log 30 3A2587H Preferred Material Settings Log Date Item Sprayed Material Sprayed Spray Tip Pressure Se tting (Mark Dial) 03/24/2011 Crown molding Water-based XWD 515 EXAMPLE ...

  • Graco 3A2587H - page 31

    Notes 3A2587H 31 Notes ...

  • Graco 3A2587H - page 32

    All written and visual data contained in this document r eflects the latest product info rmation available at the time of publica tion. Graco reserves the right to make changes at any time without not ice. For patent information, see www.gr aco.com/patents. Original instructions. This manual contains English. MM 3A2587 Graco Headquarters: Minne apo ...

Fabricante Graco Categoría Paint Sprayer

Los documentos del dispositivo Graco 3A2587H que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Graco
- manuales de instrucciones 3A2587H
- hojas de producto Graco
- folletos informativos
- o etiquetas energéticas Graco 3A2587H
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Graco 3A2587H.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Graco 3A2587H, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Graco 3A2587H. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Graco 3A2587H.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Graco 3A2587H, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Graco 3A2587H. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Graco 3A2587H.

El manual de instrucciones completo de Graco debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Graco 3A2587H - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Graco 3A2587H, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Graco 3A2587H que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Graco 3A2587H - que deben facilitarnos los primeros pasos durante el uso de Graco 3A2587H
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Graco 3A2587H
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Graco 3A2587H en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Graco 3A2587H?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Graco 3A2587H, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Graco 3A2587H probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)