Manual de instrucciones Continental BCDV48P

28 de páginas 2.43 mb
Descargar

Pasar a la página of 28

Summary
  • Continental BCDV48P - page 1

    W415-0327 / B / 12.07.07 1 W415-0327 / B / 12.07.07 $10.00 ...

  • Continental BCDV48P - page 2

    W415-0327 / B / 12.07.07 2 Framing Minimum Mantel and Enclosure Clearances Nailing T ab Installation 19-20 FINISHING Log Placement Charcoal Embers V ermiculite Glowing Embers Logo Placement Louvre Installation 21 OPTIONAL BLO WER INST ALLA TION 21 OPTIONAL F AN INST ALLA TION / GD36 THERMOST A TIC SENSOR CONTROL 22 OPERA TION / MAINTENANCE Operatin ...

  • Continental BCDV48P - page 3

    W415-0327 / B / 12.07.07 3 CONDITIONS AND LIMIT A TIONS WOLF STEEL LTD. warrants its products against manufacturing defects to the original purchaser only -- i.e., the individual or l egal entity (registered customer) whose name appears on the warranty registration card filed with WOLF STEEL Ltd. -- provided that the purchase was made through an au ...

  • Continental BCDV48P - page 4

    W415-0327 / B / 12.07.07 4 THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. In absence of local codes, install the BCDV48 to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes. Installation practices vary from region to region and it is important ...

  • Continental BCDV48P - page 5

    W415-0327 / B / 12.07.07 5 FIGURE 1 INST ALLA TION O VERVIEW FIGURE 2 ...

  • Continental BCDV48P - page 6

    W415-0327 / B / 12.07.07 6 Use only Wolf Steel, Simpson Dura-V ent, Selkirk Direct T emp or American Metal Amerivent venting components.Minimum and maximum vent lengths, for both horizontal and vertical installations, and air terminal locations for either system are set out in this manual and must be adhered to. For Simpson Dura-V ent, Selkirk Dire ...

  • Continental BCDV48P - page 7

    W415-0327 / B / 12.07.07 7 MINIMUM AIR TERMINAL L OCA TION CLEARANCES FIGURE 3 ...

  • Continental BCDV48P - page 8

    W415-0327 / B / 12.07.07 8 FIGURE 5 SPECIAL VENT INST ALLA TIONS NO TE: When ter minating v er tically , the restrictor plate W500- 0205 must be installed. R efer to Restricting V er tical V ents. PERISCOPE TERMINA TION TYPICAL MINIMUM AND MAXIMUM VENT LENGTHS FIGURES 4 a-b Use only GD401 periscope kit to locate the air termination above grade. The ...

  • Continental BCDV48P - page 9

    W415-0327 / B / 12.07.07 9 VER TICAL TERMINA TION HORIZONT AL TERMINA TION vertical rise is equal to or greater than the horizontal run horizontal run + v erti- cal rise to maximum of 40 feet vertical rise is equal to or greater than the horizontal run horizontal run + v erti- cal rise to maximum of 40 feet vertical rise is less than horizontal run ...

  • Continental BCDV48P - page 10

    W415-0327 / B / 12.07.07 10 ELBOW VENT LENGTH V ALUES DEFINITIONS HORIZONT AL TERMINA TION REQUIRED VERTICAL RISE IN FEET (V T ) CALCULA TED HORIZONT AL VENT RUN PLUS OFF- SETS IN FEET (H T ) FIGURE 6 45º FIGURE 7 90° H 1 H 2 when (H T ) < (V T ) Simple venting confi guration (only one 45º and 90° elbow) for the following symbols used in th ...

  • Continental BCDV48P - page 11

    W415-0327 / B / 12.07.07 11 V 1 HORIZONT AL TERMINA TION See graph to determine the required vertical rise V T for the required hori- zontal run H T . For vent confi gurations requiring more than one 45º and 90° elbow the following formulas apply: Formula 1: H T < 4.2 V T Formula 2: H T + V T < 24.75 feet FIGURE 8 REQUIRED VERTICAL RISE IN ...

  • Continental BCDV48P - page 12

    W415-0327 / B / 12.07.07 12 VERTICAL TERMIN A TION Example 3: V 1 = 5 ft V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 = 3 ft H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03 (one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.4 H T = H R + H O = 5.5 + 5.4 = 10.9 ft H T + V T = 10.9 + 15 = 25.9 ft Formula 1: H T < V ...

  • Continental BCDV48P - page 13

    W415-0327 / B / 12.07.07 13 H 1 VERTICAL TERMIN A TION For vent confi gurations requiring more than one 45º and one 90° elbow , the following formulas apply: F or mula 1: H T < 3V T F or mula 2: H T + V T < 40 feet Example 4: when (H T ) > (V T ) Simple venting confi gurations See graph to determine the required vertical rise V T for t ...

  • Continental BCDV48P - page 14

    W415-0327 / B / 12.07.07 14 FIGURE 16 This application occurs when venting through a roof. Installation kits for various roof pitches are available from your Continental® dealer . See Accessories to order the specifi c kit required. 1. Determine the air terminal location, cut and frame 12 3 / 4 " x 12 3 / 4 " openings in the ceiling and ...

  • Continental BCDV48P - page 15

    W415-0327 / B / 12.07.07 15 FIGURE 25 4. Insert the vent pipe assembly through the fi restop maintaining the required clearance to combustibles. Holding the air terminal (lettering in an upright, readable position), secure to the exterior wall and make weather tight by sealing with caulking (not sup- plied). 5. Apply a heavy bead of the high tempe ...

  • Continental BCDV48P - page 16

    W415-0327 / B / 12.07.07 16 FIGURE 31 RESTRICTOR PLA TE TOP OF THE FIREBOX FLUE COLLAR The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use Wolf Steel vent spacers or equivalent every 3 feet and either side of each elbow to maintain the minimum 1¼" clearance between the outer and inner vent p ...

  • Continental BCDV48P - page 17

    W415-0327 / B / 12.07.07 17 Proceed once the vent installation is complete. NOTE: All gas connections must be contained within the fi replace when complete. 1. Move the fi replace into position and secure to the fl oor through the 1/4" holes located at either side of the base. 2. The fi replace is designed to accept 3/8" gas supply li ...

  • Continental BCDV48P - page 18

    W415-0327 / B / 12.07.07 18 MINIMUM MANTEL AND ENCLOSURE CLEARANCES Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the clearance needed. Curtains, above the fi replace, must not be positioned lower than the 2" distance re- quired for the 2" combustible mantel. These same requir ements ...

  • Continental BCDV48P - page 19

    W415-0327 / B / 12.07.07 19 NAILING TA B FIGURE 39 1) Attach the nailing tabs to the corner posts using the 2 sheet metal screws supplied. Secure through the centre of the top and bottom slots in the nailing tab and then through the existing holes in the corner posts. If there are no existing holes, follow these instructions: Position the nailing t ...

  • Continental BCDV48P - page 20

    W415-0327 / B / 12.07.07 20 B A Randomly place the charcoal embers along the front and sides of the log support tray in a realistic manner . Fine dust found in the bottom of the bag should not be used. Sprinkle vermiculite around the charcoal embers. Note: Both char coal embers and vermiculite ar e not to be placed on the burner . 4. Place the smal ...

  • Continental BCDV48P - page 21

    W415-0327 / B / 12.07.07 21 FIGURE 50 FIGURE 45 INST ALLA TION TO BE DONE BY A QUALIFIED INST ALLER and must be electrically connected and grounded in accord- ance with local codes. In the absence of local codes, use the current CSA C22.1 C ANADIAN ELEC - TRICAL CODE in Canada or the ANSI/NFP A 70 NA TIONAL ELECTRICAL CODE in the United States If t ...

  • Continental BCDV48P - page 22

    W415-0327 / B / 12.07.07 22 When lit for the fi rst time, the fi replace will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur again. After extended periods of non-operation s ...

  • Continental BCDV48P - page 23

    W415-0327 / B / 12.07.07 23 VENTURI CO VER Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow . Air shutters have been factory set open according to the chart below: These settings are for the maximum horizontal vent run.- Adjust- ment may be required depending on fuel type, vent confi ...

  • Continental BCDV48P - page 24

    W415-0327 / B / 12.07.07 24 1 W357-0001 PIEZO IGNITER 2 W680-0004 THERMOPILE 3 W680-0005 THERMOCOUPLE ** 4 W010-0796 NA TURAL GAS PILOT ASSEMBL Y 4 W010-0797 PROP ANE GAS PILOT ASSEMBL Y 5* W573-0008 HIGH TEMPERA TURE SEALANT 6* W660-0005 ON/OFF TOGGLE SWITCH 7 W455-0070 NA TURAL GAS PILOT INJECTOR - #62 7 W455-0068 PROP ANE GAS PILOT INJECT OR - # ...

  • Continental BCDV48P - page 25

    W415-0327 / B / 12.07.07 25 ...

  • Continental BCDV48P - page 26

    W415-0327 / B / 12.07.07 26 TR OUBLE SHOO TING GUIDE Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button igniter . - check if the push button igniter needs tightening. - replace the wire if the wire insulation is broken or frayed. - replace the electrode if the ceramic insulator is crac ...

  • Continental BCDV48P - page 27

    W415-0327 / B / 12.07.07 27 SYMPT OM PROBLEM TEST SOLUTION Flames are consist- ently too large or too small. Carboning oc- curs. - check pressure readings: Inlet pressure can be checked by turning screw (A) counter-clockwise 2 or 3 turns and then placing pressure gauge tubing over the test point. Gauge should read 7" (minimum 4.5") water ...

  • Continental BCDV48P - page 28

    W415-0327 / B / 12.07.07 28 NO TES ...

Fabricante Continental Categoría Indoor Fireplace

Los documentos del dispositivo Continental BCDV48P que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Continental
- manuales de instrucciones BCDV48P
- hojas de producto Continental
- folletos informativos
- o etiquetas energéticas Continental BCDV48P
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Continental BCDV48P.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Continental BCDV48P, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Continental BCDV48P. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Continental BCDV48P.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Continental BCDV48P, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Continental BCDV48P. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Continental BCDV48P.

El manual de instrucciones completo de Continental debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Continental BCDV48P - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Continental BCDV48P, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Continental BCDV48P que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Continental BCDV48P - que deben facilitarnos los primeros pasos durante el uso de Continental BCDV48P
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Continental BCDV48P
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Continental BCDV48P en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Continental BCDV48P?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Continental BCDV48P, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Continental BCDV48P probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen