  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 1

    T r ansition Netw orks CPSMC08xx-100 8-Slot P ointSystem™ Chassis User’ s Guide revision B CPSMC0800-100 A C -powered CPSMC0810-100 DC -po wered ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 2

    2 CPSMC08xx-100 PointSystem™ Chassis 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 Compliance Information CISPR22/EN55022 Class A + EN55024 CE Mark FCC Regulations T his equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. T hese limits a ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 3

    3 CPSMC08xx-100 PointSystem™ Chassis T able of Contents 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.2 Unpacking the CPSMC08xx-100 Equipment . . . . . . . . . . . . . . . . .5 2 Slide-in-Modules . ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 4

    4 CPSMC08xx-100 PointSystem™ Chassis introduction 1 Intr oduction 1.1 Description T he T ransition Netw orks PointSy stem™ CPSMC08xx-100 is a 19-inch, rac k- mountable chassis for selected T ransition Networks media conv erter slide-in- modules. T he chassis allows the netw ork administrator to connect v arious copper and fiber -optic network m ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 5

    5 CPSMC08xx-100 PointSystem™ Chassis introduction 1.2 Unpacking the CPSMC08xx-100 Equipment Use the following list to verify the shipment: Item P art Number 8-Slot chassis with A C power supply CPSMC0800-100 8-Slot chassis with DC po wer supply CPSMC0810-100 PointSy stem™ chassis face plates (5) CPSFP-200 P ower Cord (varies b y country) F ocal ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 6

    6 CPSMC08xx-100 PointSystem ™ Chassis slide-in-modules 2 Slide-in-Modules 2.1 Media Converter Slide-in-Modules T ransition Networks media con verter slide-in-modules, installed in slots at the front of the chassis, allo w the network administrator to connect various copper and fiber - optic network media ov er protocols that include Ethernet, F a ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 7

    7 CPSMC08xx-100 PointSystem ™ Chassis slide-in-modules 2.1.3 Installing the Media Converter Slide-in-Modules CA UTION: W ear a grounding device and observe electrostatic disc harge precautions when installing the media con verter slide-in-module(s) into the chassis. F ailure to observ e this caution could result in damage to, and subsequent failu ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 8

    8 CPSMC08xx-100 PointSystem ™ Chassis slide-in-modules 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 2.2.4 Replacing the Media Converter Slide-in-Modules CA UTION: W ear a grounding device and observe electrostatic discharge precautions when replacing media con verter slide-in-module(s). F ailure to observ e this ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 9

    9 CPSMC08xx-100 PointSystem ™ Chassis slide-in-modules 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 2.2 Management Modules Optional network management is provided b y SNMP software embedded in T ransition Networks P ointSystem ™ management module(s) that can be installed in the CPSMC08xx-100 chassis. T ransitio ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 10

    10 CPSMC08xx-100 PointSystem ™ Chassis slide-in-modules 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 2.2.2 Installing the Management Modules CA UTION: W ear a grounding device and observe electrostatic disc harge precautions when installing the management module(s) in the CPSMC08xx-100 chassis. F ailure to observ ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 11

    11 CPSMC08xx-100 PointSystem ™ Chassis slide-in-modules 2.2.3 Replacing the Management Modules CA UTION: W ear a grounding device and observe electrostatic discharge precautions when replacing media con verter slide-in-module(s). F ailure to obser ve this caution could result in damage to, and subsequent failure of, the management module(s). NO T ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 12

    12 CPSMC08xx-100 PointSystem ™ Chassis po wer supply 3 P ow ering the CPSMC08xx-100 T he CPSMC08xx-100 chassis can be powered through an AC or DC power supply . An optional auxiliary power supply , with instant fail over protection, is also a vailable. NO TE: The CPSMC08xx-100 c hassis does not hav e an ON/OFF switc h. • P ower up the chassis b ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 13

    13 CPSMC08xx-100 PointSystem ™ Chassis po wer supply 3.1.2 DC P ow er Supply • T his product is intended to be used in a restricted access location. Proper earthing (grounding) is required to ensure safe operation. Grounding terminals are provided (section 4.1.3) for proper grounding of the device as per customer installation requirements and l ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 14

    14 CPSMC08xx-100 PointSystem ™ Chassis po wer supply 3.2 Auxiliar y P ow er Supply T he CPSMC08xx-100 chassis can also be supplied with auxiliary power from an external power conv erter , which is connected to the c hassis through the auxiliary power inlet, located on the bac k panel. (Both and A C and a DC external power converter are a vailable ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 15

    15 CPSMC08xx-100 PointSystem ™ Chassis po wer supply 3.2.2 DC Auxiliar y P ow er Supply • T his product is intended to be used in a restricted access location. Proper earthing (grounding) is required to ensure safe operation. Grounding terminals are provided (section 4.1.3) for proper grounding of the device as per customer installation require ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 16

    16 CPSMC08xx-100 PointSystem ™ Chassis chassis 4 CPSMC08xx-100 Chassis 4.1 Installing the CPSMC08xx-100 Chassis T he CPSMC08xx-100 can be installed in a standard 19-inch rac k or on a table, shelf, or other stable surface. CA UTION: Install the chassis so that the air flow ar ound it is not restricted. 4.1.1 T able-T op Installation T he CPSMC08x ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 17

    17 CPSMC08xx-100 PointSystem ™ Chassis chassis T o install the CPSMC08xx-100 chassis into a standard 19-inc h rack: 1. Determine the preferred alignment of the c hassis in the rac k. NO TE: Installation bracket mounting screws are provided. Rac k mount screws and clip nuts are NO T provided. 2. Locate six (6) installation brac ket mounting screws ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 18

    18 CPSMC08xx-100 PointSystem ™ Chassis chassis 4.1.3 Grounding Lugs T he CPSMC08xx-100 comes equipped with grounding lugs, whic h are provided for a grounding conductor wire terminated with a two-hole, compr ession-type, grounding connector . T he grounding wire -- which must be a copper conductor -- is not included with the chassis and must be p ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 19

    19 CPSMC08xx-100 PointSystem ™ Chassis chassis 4.2 Cascade Option T he management module cascade option allows the network administr ator to connect up to eight (8) CPSMC08xx-100 chassis into one manageable stac k, providing a single management source for up to 55 installed media con verter devices. T o create the cascade option, the CPSMM-200 Du ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 20

    20 CPSMC08xx-100 PointSystem ™ Chassis chassis T o cascade two or more CPSMC08xx-100 chassis: 1. Locate one (1) T ransition Networks management module cascade cable (with RJ-45 connectors installed at both ends) (P/N 6026) for each set of tw o (2) chassis to be cascaded. NO TE: T ransition Networks management module cascade cables are one (1) met ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 21

    21 CPSMC08xx-100 PointSystem ™ Chassis chassis 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 4.3 Connecting the Slide-in-Modules to the Network Once the CPSMC08xx-100 chassis has been installed, the media con verter slide-in- modules ma y be connected to the network. CA UTION: Connect input/output network cables O ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 22

    22 CPSMC08xx-100 PointSystem ™ Chassis network mgmt. 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 5 Netw ork Management T he CPSMM100 firmware and the F ocalPoint™ application are described in the Foc alPoint™ 2.0 Management Application and CPSMM100 Firmware user’ s guide (P/N 33293). T his manual is includ ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 23

    23 CPSMC08xx-100 PointSystem ™ Chassis network mgmt. 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 DB-9 Serial Port T he DB-9 serial port allows the network administr ator to configure and manage the CPSMC08xx-100 chassis using the SNMP Command-Line Interface (CLI) at an attached terminal or terminal emulator . Us ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 24

    24 CPSMC08xx-100 PointSystem ™ Chassis troubleshooting 6 T r oubleshooting 1. Are ANY of the POWER LEDs on an y of the slide-in-modules illuminated; AND/OR are the fans oper ating? YES • T he chassis is recei ving power . Proceed to the next step. NO • Ensure all power supply cables for proper connection. • Ensure the AC receptacle on the w ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 25

    25 CPSMC08xx-100 PointSystem ™ Chassis 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 T echnical Specifications F or use with T ransition Networks Model CPSMC08xx-100 or equiv alent. Dimensions 17 x 10.4 x 1.8 inches (432 x 264 x 46 mm) Shipping W eight 8 lbs. (3.6 kg) A C P ow er Supply P ower Input: 100-240 V , 5 ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 26

    26 CPSMC08xx-100 PointSystem ™ Chassis 24 hour T echnical Support: 1-800-260-1312 -- International: 00-1-952-941-7600 Cable Specifications Null Modem Cable T he Null Modem Cable is used for connecting a terminal or terminal emulator to the management module’ s DB-9 connector to access the command-line interface. T he table below shows the pin a ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 27

    27 CPSMC08xx-100 PointSystem ™ Chassis CO AX Cable Coaxial cable media is used for circuits suc h as DS3, E1 and 10Base-2 Ethernet. T he impedance of the coaxial cable is determined by the interface type, for example: • 75 ohm for DS3. • 50 ohm for 10Base-2 Ethernet. Special attention should be giv en to the grounding requirements of coaxial ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 28

    28 CPSMC08xx-100 PointSystem ™ Chassis Contact Us Technical Support T echnical support is a vailable 24 hours a da y . United States: 1-800-260-1312 International: 00-1-952-941-7600 Transition Now Chat liv e via the W eb with a T ransition Networks T echnical Support Specialist. Log onto www .transition.com and click the T ransition No w link. We ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 29

    29 CPSMC08xx-100 PointSystem ™ Chassis W arr anty Limited Lifetime Warranty Effectiv e for products shipped May 1, 1999 and after . Every T ransition Networks' labeled product purc hased after May 1, 1999 will be free from defects in material and workmanship for its lifetime. T his warr anty covers the original user only and is not transfera ...

  • Transition Networks POINTSYSTEM CPSMC0800-100 - page 30

    30 CPSMC08xx-100 PointSystem ™ Chassis Before making any non-w arranty repair , T ransition Networks requires a $200.00 charge plus actual shipping costs to and from the customer . If the repair is greater than $200.00, an estimate is issued to the customer for authorization of repair . If no authorization is obtained, or the product is deemed no ...

Fabricante Transition Networks Categoría Switch

Los documentos del dispositivo Transition Networks POINTSYSTEM CPSMC0800-100 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Transition Networks
- manuales de instrucciones POINTSYSTEM CPSMC0800-100
- hojas de producto Transition Networks
- folletos informativos
- o etiquetas energéticas Transition Networks POINTSYSTEM CPSMC0800-100
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Transition Networks POINTSYSTEM CPSMC0800-100.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Transition Networks POINTSYSTEM CPSMC0800-100, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Transition Networks POINTSYSTEM CPSMC0800-100. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Transition Networks POINTSYSTEM CPSMC0800-100.

El manual de instrucciones del dispositivo Transition Networks POINTSYSTEM CPSMC0800-100, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Transition Networks POINTSYSTEM CPSMC0800-100. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Transition Networks POINTSYSTEM CPSMC0800-100.

El manual de instrucciones completo de Transition Networks debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Transition Networks POINTSYSTEM CPSMC0800-100 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Transition Networks POINTSYSTEM CPSMC0800-100, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Transition Networks POINTSYSTEM CPSMC0800-100 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Transition Networks POINTSYSTEM CPSMC0800-100 - que deben facilitarnos los primeros pasos durante el uso de Transition Networks POINTSYSTEM CPSMC0800-100
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Transition Networks POINTSYSTEM CPSMC0800-100
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Transition Networks POINTSYSTEM CPSMC0800-100 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Transition Networks POINTSYSTEM CPSMC0800-100?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Transition Networks POINTSYSTEM CPSMC0800-100, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Transition Networks POINTSYSTEM CPSMC0800-100 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)