  • Chicago Electric 66619 - page 1

    800 RA TED W A TTS/900 MAXIMUM W A TTS PORT ABLE GENERA T OR Model 66619 OPERA TION AND SER VICE INSTRUCTIONS DANGER Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell. NEVER use inside a home or garage, EVEN IF doors and windows are open. Only use OUTSIDE and far ...

  • Chicago Electric 66619 - page 2

    Page 2 For technical questions, please call 1-800-444-3353. SKU 66619 CONTENTS IMPORT ANT SAFETY INFORMA TION ................................. 3 AC APPLICA TIONS ................................. 7 GENERA TOR PRECAUTIONS ........... 7 SET UP: .............................................. 7 OPERA TION: ..................................... 8 SERVI ...

  • Chicago Electric 66619 - page 3

    Page 3 For technical questions, please call 1-800-444-3353. SKU 66619 SA VE THIS MANUAL Keep this manual for the safety warnings and precautions, assembly , operating, inspection, maintenance and cleaning procedures. Write the product’ s serial number in the back of the manual (or month and year of purchase if product has no number). Keep this ma ...

  • Chicago Electric 66619 - page 4

    Page 4 For technical questions, please call 1-800-444-3353. SKU 66619 OPERA TING PRECAUTIONS 1. CARBON MONOXIDE HAZARD Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell. NEVER use inside a home or garage, EVEN IF doors and windows are open. Only use OUTSIDE and fa ...

  • Chicago Electric 66619 - page 5

    Page 5 For technical questions, please call 1-800-444-3353. SKU 66619 Keep the equipment, Engine, and 18. surrounding area clean at all times. Use the equipment, accessories, etc., in 19. accordance with these instructions and in the manner intended for the particular type of equipment, taking into account the working conditions and the work to be ...

  • Chicago Electric 66619 - page 6

    Page 6 For technical questions, please call 1-800-444-3353. SKU 66619   or other sources of ignition around the equipment, especially when refuelling.   ...

  • Chicago Electric 66619 - page 7

    Page 7 For technical questions, please call 1-800-444-3353. SKU 66619 AC APPLICA TIONS Before connecting an appliance or 1. power cord to the generator: Make sure that it is in good working order . Faulty appliances or power cords can create a potential for electrical shock. If an appliance begins to operate 2. abnormally , becomes sluggish or stop ...

  • Chicago Electric 66619 - page 8

    Page 8 For technical questions, please call 1-800-444-3353. SKU 66619 REV 09c Connect the Generator only to a 5. load or electrical system (120 V~) that is compatible with the electrical characteristics and rated capacities of the Generator . ? ...

  • Chicago Electric 66619 - page 9

    Page 9 For technical questions, please call 1-800-444-3353. SKU 66619 THIS UNIT CAN POWER THE FOLLOWING ITEMS ITEM RUNNING W A TTS ST ART -UP W A TTS T en 75 Watt Light Bulbs 750 1/4HP Compressor 600 900 1/6HP Motor 500 800  400 600 Mini Refrigerator 400 700 15 Amp Battery Charger 380 String T rimmer 350 500 T able/Box ...

  • Chicago Electric 66619 - page 10

    Page 10 For technical questions, please call 1-800-444-3353. SKU 66619 FIGURE C FUEL T ANK CAP (76) STRAINER (74) 3. Remove the Fuel T ank Cap (76) and check the fuel level. (See Figure C.) W ARNING! TO PREVENT SERIOUS INJUR Y FROM FIRE:   ventilat ...

  • Chicago Electric 66619 - page 11

    Page 1 1 For technical questions, please call 1-800-444-3353. SKU 66619 in the “RUN” position when starting a warm Engine. (See Figure E.) FIGURE F “ON” POWER SWITCH 3. Then turn the Engine Power Switch to its “ON” position. (See Figure F .) FIGURE G RECOIL ST ARTER HANDLE (42) 4. Grasp the Recoil Starter Handle (42) and pull slowly unt ...

  • Chicago Electric 66619 - page 12

    Page 12 For technical questions, please call 1-800-444-3353. SKU 66619 Equipment Operation Load And Circuit Breaker: The total combined load through the 1. outlet on the Generator must not exceed the rated maximum power (800 watts) of the unit. FIGURE I RESET OFF CIRCUIT BREAKER 2. Always reduce the load if the AC Circuit Breaker turns off. Once th ...

  • Chicago Electric 66619 - page 13

    Page 13 For technical questions, please call 1-800-444-3353. SKU 66619 REV 09c, 09g, 09k FIGURE L “OFF” POWER SWITCH 3. T urn of f the Generator ’ s Power Switch to stop the Engine. (See Figure L.) FIGURE M “OFF” FUEL SWITCH (80) 4. T urn the Fuel Switch (80) to its “OFF” position. (See Figure M.) Allow the Generator to completely coo ...

  • Chicago Electric 66619 - page 14

    Page 14 For technical questions, please call 1-800-444-3353. SKU 66619 SPECIFICA TIONS Engine T ype   Horizontal Shaft. Engine Starter T ype Recoil Starter Engine Power Rating 2.0 H.P . Displacement 63cc Required Fuel Mixture (50:1) ...

  • Chicago Electric 66619 - page 15

    Page 15 For technical questions, please call 1-800-444-3353. SKU 66619 Spark Plug Maintenance: Disconnect Spark Plug Wire from end 1. of plug. Clean out debris from around Spark Plug. Using the spark plug wrench provided, 2. remove the Spark Plug. Inspect the Spark Plug: 3. If the electrode is oily , clean it using a clean, dry rag. If the electrod ...

  • Chicago Electric 66619 - page 16

    Page 16 For technical questions, please call 1-800-444-3353. SKU 66619 Storage W ait for the Engine to cool, then clean 1. the Engine with a clean cloth. When the equipment is to remain idle for 2. longer than 20 days, prepare the Engine for storage as follows: Empty the Fuel T ank and drain all fuel a. lines. Clean out area around Spark Plug. b. R ...

  • Chicago Electric 66619 - page 17

    Page 17 For technical questions, please call 1-800-444-3353. SKU 66619 TROUBLESHOOTING - ENGINE Problem Possible Causes Probable Solutions Engine will not start FUEL RELA TED: Improper gasoline/2 cycle oil mix. 1. No fuel in tank or fuel valve closed. 2. Choke not in start position, especially 3. with cold engine. Low quality or deteriorated, old 4 ...

  • Chicago Electric 66619 - page 18

    Page 18 For technical questions, please call 1-800-444-3353. SKU 66619 TROUBLESHOOTING - ENGINE Problem Possible Causes Probable Solutions Engine misres Spark plug wire loose. 1. Incorrect spark plug gap or damaged 2. spark plug. Defective spark plug wire. 3. Old or low quality gasoline. 4. Incorrect compression. 5. Check wire connections. 1. ? ...

  • Chicago Electric 66619 - page 19

    Page 19 For technical questions, please call 1-800-444-3353. SKU 66619 TROUBLESHOOTING - GENERA TOR UNIT ? ...

  • Chicago Electric 66619 - page 20

    Page 20 For technical questions, please call 1-800-444-3353. SKU 66619 P ARTS LIST Part Description Qty . 1 Left Crankcase 1 2 Right Crankcase 2 3 Bearing (6004) 2 4 Hole Circlip (#42) 1 5 Oil Seal (20 x 30 x 7) 2 6 Pin (10 x 7 x 14) 2 7 Stud (AM6 x 50) 2 8 Flange Nut (M6) 4 9 Flange Bolt (M6 x 45) 4 10 Stud (AM6 x 100) 2 11 Oil Seal (6 x 12 x 7) 1 ...

  • Chicago Electric 66619 - page 21

    Page 21 For technical questions, please call 1-800-444-3353. SKU 66619 ASSEMBL Y DIAGRAM ...

  • Chicago Electric 66619 - page 22

    Page 22 For technical questions, please call 1-800-444-3353. SKU 66619 ASSEMBL Y DIAGRAM - CONTINUED ...

  • Chicago Electric 66619 - page 23

    Page 23 For technical questions, please call 1-800-444-3353. SKU 66619 WIRING DIAGRAM ...

  • Chicago Electric 66619 - page 24

    Page 24 For technical questions, please call 1-800-444-3353. SKU 66619 LIMITED 1 YEAR / 90 DA Y W ARRANTY Harbor Freight T ools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that for a period of ninety days from date of purchase that the engine/motor , the belts ...

  • Chicago Electric 66619 - page 25

    Page 25 For technical questions, please call 1-800-444-3353. SKU 66619 Harbor Freight T ools Emission Control Defects W arranty Provisions Length of Coverage 1.           quent purchase ...

Fabricante Chicago Electric Categoría Portable Generator

Los documentos del dispositivo Chicago Electric 66619 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Chicago Electric
- manuales de instrucciones 66619
- hojas de producto Chicago Electric
- folletos informativos
- o etiquetas energéticas Chicago Electric 66619
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Chicago Electric 66619.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Chicago Electric 66619, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Chicago Electric 66619. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Chicago Electric 66619.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Chicago Electric 66619, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Chicago Electric 66619. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Chicago Electric 66619.

El manual de instrucciones completo de Chicago Electric debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Chicago Electric 66619 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Chicago Electric 66619, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Chicago Electric 66619 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Chicago Electric 66619 - que deben facilitarnos los primeros pasos durante el uso de Chicago Electric 66619
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Chicago Electric 66619
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Chicago Electric 66619 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Chicago Electric 66619?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Chicago Electric 66619, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Chicago Electric 66619 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen