Service Manual L22-303 Rev 0 (01/07 ) IMPORTANT FOR FU TURE REFERENCE Please complete this information and retain t his manual for the life of the equi pment: Model #: ___________ _____________ ___ Serial #: ___________ _____________ ___ Date Purchased: ___________ _________ ENGLISH I8 Water Cooker C omputer Covering (P/N PP11375) This manual detai ...
-
Pitco Frialator L22-303 - page 2
I8 W ater Cooker Computer Service Pitco P/N PP11375 2 L22-303 Rev 0 (01/ 07) Table of Contents 1.0 Key Locations and F unctions: 4 1.1 To turn the app liance ON: 4 1.2 To turn the app liance OFF: 4 1.3 To start a cook : 4 1.4 To cancel a cook : 4 1.5 To Check Actual and Set Tem peratures: 4 1.6 To view the curre nt Cook , Shake and Hold t imer s et ...
-
Pitco Frialator L22-303 - page 3
I8 W ater Cooker Computer Service Pitco P/N PP11375 L22-303 Rev 0 (01/ 07) 3 4.6 Recovery Test Va lue: 11 4.7 More Service Men u Options 11 4.7.1 Low Read y Level Adjustm ent: 11 4.7.2 High Ready Leve l Adjustm ent: 11 4.7.3 Low Dead Band Adjustm ent: 12 4.7.4 High Dead Ban d Adjustm ent: 1 2 4.7.5 Control Tem perature Average S etting: 12 4.7.6 Di ...
-
Pitco Frialator L22-303 - page 4
I8 W ater Cooker Computer Service Pitco P/N PP11375 4 L22-303 Rev 0 (01/ 07) 4 0 9 1 2 3 4 5 6 7 8 1.0 Key Locations and Functions: Program Key Temperature Key Clock K ey Product Ke ys 8 Digit D isplay P roduct Keys 1.1 To tu rn the appliance ON: If power is app lied to the appl iance(plugged i n) and the contro l is off , the displa y will be blan ...
-
Pitco Frialator L22-303 - page 5
I8 W ater Cooker Computer Service Pitco P/N PP11375 L22-303 Rev 0 (01/ 07) 5 4 4 To view the set tem perature, pr ess the therm ometer k ey twice. The contro l will mom entarily display [ SET x xx’F ] (where x xx is the set t em perature), and then return to n orm al operation and dis play either [ RE ADY ], or [ ACT xxx’F ]. 1.6 To view the cu ...
-
Pitco Frialator L22-303 - page 6
I8 W ater Cooker Computer Service Pitco P/N PP11375 6 L22-303 Rev 0 (01/ 07) 0 To deactivate the c ook tim er on a product k ey, enter in a co ok time of zero for this k ey. 2.2.2 Shake Tim e Shake Tim e is an alarm that sounds while a co ok tim er is running to prom pt an opera tor to shake the product in the bask et. T he default value for shake ...
-
Pitco Frialator L22-303 - page 7
I8 W ater Cooker Computer Service Pitco P/N PP11375 L22-303 Rev 0 (01/ 07) 7 1 2 3 4 3.1 Fahrenheit or Cel cius Temper ature Displa y: This control wil l display tem peratures in Fahre nheit(ºF).or C elsius(ºC) de grees. The default setting is degre es Fahrenhe it(ºF). W ith the control displa y showing [ SELECT ], press product k ey 1. The d is ...
-
Pitco Frialator L22-303 - page 8
I8 W ater Cooker Computer Service Pitco P/N PP11375 8 L22-303 Rev 0 (01/ 07) 7 1 6 8 6 5 3.5 Control or Tim er Mode Settin g: This control can operate in one of two basic m odes, Contro l or Tim er mode. T he default mode setting is Contro l mode, and is t he setting f or norm al operation. In this m ode, the cook tim ers are active and th e heat c ...
-
Pitco Frialator L22-303 - page 9
I8 W ater Cooker Computer Service Pitco P/N PP11375 L22-303 Rev 0 (01/ 07) 9 2 3 4 4.2 Cancel Delay Setting: This setting controls t he length of tim e(in seconds) necessar y for a k ey press to cance l an active cook timer . A setting of zero disables this cance l dela y setting and a cook tim er cancels as soon as a product k ey is pressed. A can ...
-
Pitco Frialator L22-303 - page 10
I8 W ater Cooker Computer Service Pitco P/N PP11375 10 L22-303 Rev 0 (01/07) 5 1 2 3 4 5 7 8 connector pin. Co ntroller inputs can be verifie d by the ON or OFF state of the ke y indicator above the appro priate product k ey. W ith the control displa y showing [ SERVIC E ], press product k ey 5 to ent er into the diagnostics m enu. T he control dis ...
-
Pitco Frialator L22-303 - page 11
I8 W ater Cooker Computer Service Pitco P/N PP11375 L22-303 Rev 0 (01/ 07) 11 7 8 1 2 4.6 Recovery Test Value: This control records the heat up t ime f or the appliance. A poorly running appliance will have an increased recov ery tim e. Select this m enu option to view t he last record ed recovery tim e for this appliance. The rec over y time is th ...
-
Pitco Frialator L22-303 - page 12
I8 W ater Cooker Computer Service Pitco P/N PP11375 12 L22-303 Rev 0 (01/07) 3 4 5 6 4.7.3 Low Dead Ban d Adjustment: This setting adjus ts the vat tem perature lim it below the set tem perature, w here the he at demand output will be ON to ap ply heat to t he vat. At vat t emperatures below this value, heat will be app lied to the vat. F or exam p ...
-
Pitco Frialator L22-303 - page 13
I8 W ater Cooker Computer Service Pitco P/N PP11375 L22-303 Rev 0 (01/ 07) 13 7 8 service menu op tions below, or pres s the pro gram key three times to return to norm al operation(disp lay shows either [ R E ADY ], [ A CT xxx’F ], or [ FILLING ]). 4.7.7 Minimum Fill T ime Setting: This setting adjus ts the m inimum length of time the heat c ontr ...
-
Pitco Frialator L22-303 - page 14
I8 W ater Cooker Computer Service Pitco P/N PP11375 14 L22-303 Rev 0 (01/07) 5.2 High Temp erature Alarm: [ HIGH TM P ]. This alarm will occur if the vat tem perature exc eeds the se t temperature value by 35 ° F. If a high vat tem perature a larm occ urs, all heating and co oking functio ns are suspended. 5.3 Drain Valve Alarm: [ DRAINING ] an d ...
-
Pitco Frialator L22-303 - page 15
I8 W ater Cooker Computer Service Pitco P/N PP11375 L22-303 Rev 0 (01/ 07) 15 12 9 6 11 10 8 5 7 4 3 2 1 11 8 5 2 12 963 10 7 4 1 J1 6.0 Electrical Connections(J1): J1 Connection Type Nominal Notes: 1 24VAC IN P W R 24VAC 24VAC +20% / -1 5% 50/60Hz 2 24VAC COM P W R 0VAC AC RET URN 3 PROBE + 4 PROBE - THERMISTO R PROBE Resistance var ies with vat t ...
-
Pitco Frialator L22-303 - page 16
I8 W ater Cooker Computer Service Pitco P/N PP11375 16 L22-303 Rev 0 (01/07) 7.0 Probe Resistance Chart: NOTE: The resistance of eith er probe lead m easured to the frame of the applianc e should read as an open o n a meter(r esistance > = 1Mohm ). Pr obe Te m p ( ° F) Pr o be Te m p ( ° C) Re s i st an ce ( O h m s) Pr obe Te m p ( ° F) Pr o ...
-
Pitco Frialator L22-303 - page 17
I8 W ater Cooker Computer Service Pitco P/N PP11375 L22-303 Rev 0 (01/ 07) 17 8.0 Physical Dimensions: 0 9 1 2 3 4 5 6 7 8 ...
-
Pitco Frialator L22-303 - page 18
I8 W ater Cooker Computer Service Pitco P/N PP11375 18 L22-303 Rev 0 (01/07) NOTES: ____________ ____________ ___________ ____________ ________ ____________ ________ _ ____________ ____________ ___________ ____________ ________ ____________ ________ _ ____________ ____________ ___________ ____________ ________ ____________ ________ _ ____________ _ ...
-
Pitco Frialator L22-303 - page 19
I8 W ater Cooker Computer Service Pitco P/N PP11375 L22-303 Rev 0 (01/ 07) 19 NOTES; ____________ ____________ ___________ ____________ ________ ____________ ________ _ ____________ ____________ ___________ ____________ ________ ____________ ________ _ ____________ _____________ __________ ____________ ________ ____________ ________ _ ____________ ...
-
Pitco Frialator L22-303 - page 20
L22-303 Rev 0 (01/07 ) In the event of pr oblems with or questions about your order, p lease contact the Pitco Fri alator factor y at (800)258-3708 U S and Cana da only or (603)225-6684 W or ldwide. www.pitco.com In the event of pr oblems with or questions about your equipm ent, please contact the Pitco Fri alator Aut horized Service and Parts( ASA ...
¿Tienes una pregunta acerca de Pitco Frialator L22-303?
Utiliza el formulario que se encuentra abajo
Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Pitco Frialator L22-303, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Pitco Frialator L22-303 probablemente compartirá una forma de solucionarlo.