-
Taylor 1525 - page 1
by 1525 1 W eatherGuide ™ Syst em with Remote Sensor Instruction Man ual ...
-
Taylor 1525 - page 2
W elcome t o the T a ylor ® W eat herGuide Syst em. Simple, r eliable, accurate…it allows y ou to monitor indoor or outdoor locations from one room. T he base unit reads indo or conditio ns, while the remote sens or wir elessl y re ports outd oor we ather co nditio ns back to th e base unit for an all-in-one w eather displa y . Plan your work da ...
-
Taylor 1525 - page 3
T o Po wer your W eatherGuide ™ Y our W eatherGuide™ base unit is power ed by 2 AAA batteries (not included). Remov e the batter y compar tment cover on the back of t he unit. Install 2 AAA batteries. Replace the battery compar tment cover . Im porta nt: P ow er t he ba se uni t bef or e ins tall ing b att erie s in th e re - mo te sen sor , or ...
-
Taylor 1525 - page 4
T r ansmission successful 4 If the t ransmis sion is su ccessfu l, the r emote sensor readings and a icon will appear on the base u nit. If dashes a re still di spla yed on the receiver unit, press the Tx bu tton again. Rep lac e the remo te’ s ba tter y co mpa r t- ment cov er . The remote will aut omatically transmit readings to the base unit. ...
-
Taylor 1525 - page 5
K eyhole T able Stand 5 How to Display y our WeatherGuide™ T able top – use the T able Stand on the back of the base and r emote sensor units W all – u se the k eyh ole o n the b ack of t he ba se an d re mot e sens or un its . Base Unit Remote Sensor Base unit location – Pl ace th e unit i ndo ors in a w el l-v ent ilat ed lo cati on a wa ...
-
Taylor 1525 - page 6
How to Set the Cl ock Manuall y T o man ually set the clock: Y our W eatherGuide™ has a 12 hour clock function. T o set the clock: 1. P ress a nd hold the “S et” butt on lo- cated o n the back of the ba se unit. The h our digi ts wil l flash. 2. Pr ess “+C/F” to change the hours. Pr ess “S ET” to ent er . 3. P res s “+C/F ” to cha ...
-
Taylor 1525 - page 7
How to Read Y our W eatherGuide™ The base unit displa ys indoor conditions from its location. The remote unit will trans mit weather readings fr om its location back to the base unit. Alt erna tely , the remo te se nso r’ s probe cord may be use d. Plug t he probe cor d into the rubber plug on the remote sensor . Allow the end to hang where y o ...
-
Taylor 1525 - page 8
Auto Scro ll feature – the base unit can be set to a utomatic ally scr oll thr ough r ead- ing s. T o ac tiv ate Au to Scrol l, press th e “Channel” button on the back of the base unit u ntil the a uto scr oll sym bol app ears on the LCD . The base unit w ill autom atically disp lay base a nd remot e readi ngs fo r 10 seconds each. T emperatu ...
-
Taylor 1525 - page 9
T o View Mini mum/ Max imum te m- perature / indoor h umidity readings Y our W eatherGuide™ will store the last r eco rde d hig h and l ow te mpe rat ur es an d in- door h umidi ty ov er a 24 hour p eriod. The 24 hour period starts when the batteries ar e inst alled . 1. Press the “Min/Max” button once to see the hig hest t empe rature/i ndoo ...
-
Taylor 1525 - page 10
T emperatur e T rend Indicator s Y our W eathe rGuide™ will indicate if temperatu res ar e rising, falling, or steady . ind icat es Ris ing T e mpe rat ures readin gs (temperatures ha v e gone up more than 2 degrees in an hour) indicates Steady T emperature readings ind icat es F all ing T e mpe rat ures ( tem per a - tur es ha v e gone d own mor ...
-
Taylor 1525 - page 11
11 11 Backlight F eature The base unit has a backlight for easy vie wing of the screen. Press the “Light” button to turn the backlight on for 3 seconds. Press LIGHT for a 3 second backlight T o Switch Betw een °F and °C Pr ess the “+C/F ” butto n to swit ch betw een Fah renhe it an d Cels ius t emp era ture di s- pla ys. Low Battery Indic ...
-
Taylor 1525 - page 12
12 T roubl e-Shooting Disconnected Signals If th e rec eive r unit do es not r ecei ve a tr ansmi ssion f rom a r emo te chan - nel f or 1 hour , th e displ ay w ill sho w dash es. T o co rr ect thi s pro blem: 1. Check that the remote i s properly positioned, within the appr o- pri ate tr ans mis sio n ran ge . T ransmi ssi ons a re vast ly affe c ...
-
Taylor 1525 - page 13
13 T ransmission Collision Signals f rom othe r household de vices, such as do orbells, home s ecurity systems and entry controls, ma y interfere. This is normal and does not affect the general performance of thi s product. The transmission will resume once the interf erence recedes. Note: This equipment has been tested and found to compl y with th ...
-
Taylor 1525 - page 14
14 Pr ecautions 1. The rec eiver i s inte nde d for in doo r use o nly . I t is no t sea led against moisture and could be dam aged if used outdoors. 2. Do not immerse the unit in water . If you spill liquid on it, dr y im- mediately with a soft, lint-free cloth. 3. Do not clean the unit with abrasiv e or corrosiv e materials. This ma y scratch pla ...
-
Taylor 1525 - page 15
Specifications Range of temperature measur ement: Receiver unit (indoor onl y): 14°F to 158°F (-10°C to 70°C) Remote unit: -40°F to 158°F (-40°C to 70°C) Indoor Humidity: 20% - 99% RH Resolution: 0.1 degree for temperature, 1% for humidity T emperatur e/Indoor Humidity trends – rising, falling or steady Minimum/Maximum dail y temperature/ ...
-
Taylor 1525 - page 16
One Y ear W arranty This pr oduct is warranted ag ainst defects in materia ls or workmanship for one (1) y ear from date of original pur chase . It does not cover damages or wear r esulting from accident, misuse , abuse, commer cial use, or unauthorized adjustment and/or repair . Should this product re- quire service (or replacement at our option) ...
¿Tienes una pregunta acerca de Taylor 1525?
Utiliza el formulario que se encuentra abajo
Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Taylor 1525, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Taylor 1525 probablemente compartirá una forma de solucionarlo.