    Intel in Communications Building Fault-tolerant SS7 Systems Using the Intel ® NetStructur e™ SIU520 SS7 Signaling Gateway Application Note ...

  • Intel SIU520 SS7 - page 2

    Building Fault-tolerant SS7 Systems Using the Intel ® NetStructure™ SIU520 SS7 Signaling Gateway Application Note T able of Contents Abstract 1 Introduction 1 Overview of SIU Operation 2 Circuit-switched API Operation 2 T ransaction-based API Operation 3 Management Interface 3 Potential Points of Failure 3 Failure of SS7 Links 4 Failure of Route ...

  • Intel SIU520 SS7 - page 3

    Application Note Building Fault-tolerant SS7 Systems Using the Intel ® NetStructure™ SIU520 SS7 Signaling Gateway T able of Figur es Figure 1 Structure of the Intel ® NetStructur e™ SIU520 SS7 Signaling Gateway 2 Figure 2 Integrating the SIU520 3 Figure 3 SIU Connected to Adjacent Node with T wo Links in Link Set 4 Figure 4 SIU520 Connected t ...

  • Intel SIU520 SS7 - page 4

    Abstract In order to achieve five-nines (99.999%) r eliability and a high degree of fault tolerance in an SS7 envir onment using Intel ® NetStructure™ SIU520 signaling gateways, an SS7 end point spread over two signaling interface units (SIUs) and multiple application servers can be configured and deployed. Splitting the pr otocol processing fun ...

  • Intel SIU520 SS7 - page 5

    Overview of SIU Operation The Intel NetStructure SIU520 SS7 signaling gateway is an SS7 network access product that pr ovides a resilient interface to SS7 networks via a TCP/IP local area net- work (LAN). As shown in Figure 1, SIU520 softwar e includes SS7 protocol layers, as well as a configuration and management module. The SIU520 supports multip ...

  • Intel SIU520 SS7 - page 6

    T ransaction-based API Operation TCAP-based applications can be distributed on multiple application hosts using two differ ent methods which are explained in details further in this document (see “Failure of Applications”, pg. 15). These methods imply running TC-user application parts (such as GSM-MAP , INAP , or IS-41) on each application host ...

  • Intel SIU520 SS7 - page 7

    Failure of SS7 Links Problem — With a single link to the adjacent signaling point, service is disrupted if the link goes down for some reason (i.e., layer 1 alarm, congestion). Solution — Link resiliency is achieved by using multiple links between a local point code and an adjacent point code. By definition, such links are said to belong to the ...

  • Intel SIU520 SS7 - page 8

    Failure of Routes Problem — With a single route to a destination point code (DPC), service can be disrupted if all the links of the link set used to reach that signaling node fail. Route failover is a standard MTP3 operation which does not requir e any specific action from the user application. Solution — T o eliminate this single point of fail ...

  • Intel SIU520 SS7 - page 9

    Failure of Power Supply Problem — Ensuring that the unit survives the loss of one power supply and making it possible to replace a failed power supply without affecting the availability of the system. Solution — The Intel NetStructure SIU520 SS7 signaling gateway can be optionally configured with a r edundant and hot swappable power supply . De ...

  • Intel SIU520 SS7 - page 10

    partner SIU across the inter -SIU link set and sent out to the adjacent signaling point by the partner unit. The inter - SIU link set also provides the capability of message retrieval and r etransmission when a changeover operation occurs between the two units. ■ For circuit-switched applications, the cir cuit groups ar e configured on both units ...

  • Intel SIU520 SS7 - page 11

    In case (A), since the F-links all exist in the same link set, messages may be sent from the adjacent SSP/SCP to either SIUA or SIUB. If an SIU receives a message fr om the SS7 network for a circuit or transaction that it does not control, this r eceive message is passed automatically to the other SIU for processing via the TCP/IP LAN. Connection t ...

  • Intel SIU520 SS7 - page 12

    T able 1 compares the advantages and disadvantages of these methods. T able 1. Comparison of a Straight Link Configuration vs. a Crossed Link Configuration Comparison Subject Straight Configuration Crossed Configuration Load sharing -+ STP A can only load share traffic Each STP can load share between the two SIUs, for SIUA and vice-versa optimizing ...

  • Intel SIU520 SS7 - page 13

    Dual SIU Architectur e for Circuit-Switched Applications Within the SIU environment, circuits ar e configured in groups, each gr oup equating to all the circuits multiplexed onto a single E-1 or T -1 PCM trunk. The SIU provides the SS7 cir cuit control and the application platform (or host) terminates the physical channels, typically with a voice p ...

  • Intel SIU520 SS7 - page 14

    If all the links between the controlling SIU and the adjacent signaling point fail, all transmit traffic is automatically routed to the adjacent signaling point through the inter -SIU link set as shown in Figure 11. The application should continue to use the SIU as before, directing all outgoing cir cuit requests to SIUA. If the controlling SIU fai ...

  • Intel SIU520 SS7 - page 15

    The circuit gr oup control will then appear as shown in Figure 12. The user application software should r eset all idle circuits following a transfer , and reset all r emaining circuits as they become idle. When the failed unit recovers, contr ol of the circuits may be transferred back by the application. Circuit gr oup control is transferr ed by t ...

  • Intel SIU520 SS7 - page 16

    Dual SIU Architectur e for T ransaction-based Applications There ar e two ways of architecting a dual-r esilient SIU520-based system for processing TCAP transactions. ■ Running the SS7 stack up to SCCP on the SIUs ■ Running the SS7 stack up to TCAP on the SIUs In the first case, TCAP and potential layers sitting on top of TCAP run on the applic ...

  • Intel SIU520 SS7 - page 17

    In the second case, each unit controls half of the total available transactions. (The Intel NetStructure SIU520 SS7 signaling gateway supports up to 16,384 transac- tions. A dual-resilient system can consequently handle up to 32,768 simultaneous transactions.) Each transaction is processed for its entir e duration by the SIU that processed the firs ...

  • Intel SIU520 SS7 - page 18

    Failure of IP Subnetwork Problem — Should one subnetwork go down due to a network component failure, the hosts connected to the SIU over the other subnetworks will remain active and attempt to preserve half of the total system capacity . Solution — There ar e two Ethernet ports on the SIU520. This allows splitting the IP connections between the ...

  • Intel SIU520 SS7 - page 19

    TCAP Resiliency Based on DTS/DTC Option Alternatively , it is possible to distribute SCCP traffic to multiple application hosts using the distributed transac- tion server/distributed transaction client (DTS/DTC) soft- ware option, as shown on Part B of Figur e 13. In this architectur e, TCAP and potential application parts run on each application h ...

  • Intel SIU520 SS7 - page 20

    Configuring a Dual SIU Pair T o create a dual-r esilient configuration for the Intel NetStructure SIU520 SS7 signaling gateway , modifications are r equired to both the system configuration (done using the man machine interface [MMI]) and the protocol configuration (in the config.txt parameter file). This may be done remotely and trans- ferred to t ...

  • Intel SIU520 SS7 - page 21

    The inter -SIU signaling link set can be configur ed to use any signaling processor on any signaling car d and may be carried on any of the available interfaces on the signaling card. If V .11 interfaces are used to carry the SS7 signaling between the SIU and the network (this is typically the case in North America), it is possible that there will ...

  • Intel SIU520 SS7 - page 22

    using the MTP_LINK command, assigning incrementing <link_ref> and <slc> values as normal. The <bpos> and <blink> parameters define which SS7 processor (there ar e three on each signaling car d) manages each link. If a V .11 port is being used, <blink> must be either 1 or 2. For a link using a PCM port, the physical loc ...

  • Intel SIU520 SS7 - page 23

    For an SIU pair connected to a mated STP pair , carrying the inter -SIU link over the second E-1 port of the first signaling card the configuration (Figur e 20) would be: For SIUA MTP_CONFIG 0 0 0x0000 MTP_LINKSET 0 300 1 0x8000 300 0x8 MTP_LINKSET 1 400 1 0x0000 300 0x8 MTP_LINK 0 0 0 0 1 1 1 1 0 0x4006 MTP_LINK 1 1 0 0 1 2 1 2 16 0x0006 MTP_ROUTE ...

  • Intel SIU520 SS7 - page 24

    Communicating with Both SIUA and SIUB The user application exchanges information with the SIU via API messages (MSG). In a dual SIU environment, each time the user application sends a message to the SIU, this should be directed to either SIUA or SIUB using a library function GCT_set_instance . In the receive direction, the application can determine ...

  • Intel SIU520 SS7 - page 25

    conc_id on the host ( conc_id is set when the RSI link was started, optionally by rsicmd ). This message will only be received by the application if the RSI link is con- figured with the conc_id set to the application’ s module ID. At the same time, the affected SIU (if it can), will issue an API_MSG_SIU_ST A TUS message with status value 30 (dec ...

  • Intel SIU520 SS7 - page 26

    Recovery of the Failed Unit The host application is informed of recovery of the communication to the SIU with the same method used for notification of the failure. The RSI_MSG_LINK_ ST A TUS message in this case contains a status value of 1 (link to SIU recover ed). The host nominated to receive management indications (normally host 0) will also re ...

  • Intel SIU520 SS7 - page 27

    Appendix A: Frequently Asked Questions Q: How can I tell if an SIU fails? A: The status of the communication between the host and the SIU is indicated by RSI_MSG_ST A TUS messages. Q: What happens if an SS7 message for a circuit or transaction is received by an SIU that does not control that cir cuit or transaction? A: The message is automatically ...

  • Intel SIU520 SS7 - page 28

    T o learn more, visit our site on the World Wide Web at http://www .intel.com . 1515 Route T en Parsippany , NJ 07054 Phone: 1-973-993-3000 INFORMA TION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL ® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT , EXCEPT ...

Fabricante Intel Categoría Switch

Los documentos del dispositivo Intel SIU520 SS7 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Intel
- manuales de instrucciones SIU520 SS7
- hojas de producto Intel
- folletos informativos
- o etiquetas energéticas Intel SIU520 SS7
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Intel SIU520 SS7.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Intel SIU520 SS7, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Intel SIU520 SS7. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Intel SIU520 SS7.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Intel SIU520 SS7, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Intel SIU520 SS7. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Intel SIU520 SS7.

El manual de instrucciones completo de Intel debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Intel SIU520 SS7 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Intel SIU520 SS7, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Intel SIU520 SS7 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Intel SIU520 SS7 - que deben facilitarnos los primeros pasos durante el uso de Intel SIU520 SS7
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Intel SIU520 SS7
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Intel SIU520 SS7 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Intel SIU520 SS7?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Intel SIU520 SS7, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Intel SIU520 SS7 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)