Part No. D24024-023-1 Generator Instruction manual T o learn more about Porter -Cable visit our website at: http://www .porter -cable.com The Model and Serial No. plate is located on the frame. Record these numbers in the spaces below and retain for futur e refer ence. Model No. T ype Serial No. ESP AÑOL: PÁGINA 21 FRANÇAIS: P AGE 41 IMPORT ANT ...
-
Porter-Cable H451CS - page 2
2 — ENG This product is equipped with a spark arr esting muffler . If the product will be used ar ound flammable materials, or on land covered with materials such as agricultural cr ops, forest, brush, grass, or other similar items, then an approved spark arr ester must be installed and is legally requir ed in the state of California. It is a vio ...
-
Porter-Cable H451CS - page 3
3 — ENG W ARRANTY Porter -Cable Corporation 4825 Highway 45 North P .O. Box 2468 Jackson, TN 38302-2468 1-888-559-8550 PORTER-CABLE CORPORA TION warrants to the original purchaser that each new electric generator and service part is free fr om defects in material and workmanship, and agrees to r epair or replace under this warranty any defective ...
-
Porter-Cable H451CS - page 4
4 — ENG Attempting to connect generator directly to the electrical system of any building structure. Back feeding electricity through a building’ s electrical system to the outside utility feed lines could endan- ger repair persons attempting to r e- store service. Attempting to connect to the incom- ing utility service could result in elec- tr ...
-
Porter-Cable H451CS - page 5
5 — ENG READ AND UNDERST AND ALL WARNINGS BEFORE A TTEMPTING TO OPERA TE GENERA TOR. Use of worn, damaged, under- sized or ungrounded extension cords. Placing generator on or against highly conductive surface, such as a steel walkway or metal roof. Improper connection of items to generator . Operation of unit when damaged, or with guards or panel ...
-
Porter-Cable H451CS - page 6
6 — ENG READ AND UNDERST AND ALL WARNINGS BEFORE A TTEMPTING TO OPERA TE GENERA TOR. RISK OF FIRE Inadequate ventilation for generator Use care in filling the tank to avoid spilling fuel. Make sure fuel cap is secured tightly and check engine for fuel leaks before starting engine. Move generator away from r efueling area or any spillage before st ...
-
Porter-Cable H451CS - page 7
7 — ENG READ AND UNDERST AND ALL WARNINGS BEFORE A TTEMPTING TO OPERA TE GENERA TOR. RISK OF BREA THING - INHALA TION HAZARD Operate generator in clean, dry , well ventilated area. Never operate unit in enclosed areas such as garages, basements, storage, sheds, or in any location occupied by humans or animals. Keep chil- dren, pets and others awa ...
-
Porter-Cable H451CS - page 8
8 — ENG READ AND UNDERST AND ALL WARNINGS BEFORE A TTEMPTING TO OPERA TE GENERA TOR. • Review and understand all of the operating instructions and warnings in this manual. • Become familiar with the oper- ation and controls of the gen- erator . Know how to shut it off quickly . • Equip area of operation with a fire extinguisher certified to ...
-
Porter-Cable H451CS - page 9
9 — ENG RISK FROM LIFTING HAZARD HOW TO PREVENT IT WHA T COULD HAPPEN The generator is too heavy to be lifted by one person. Obtain assis- tance from others befor e you try to move it. Serious injury can result fr om attempt- ing to lift too heavy an object. Lifting a very heavy object. READ AND UNDERST AND ALL WARNINGS BEFORE A TTEMPTING TO OPER ...
-
Porter-Cable H451CS - page 10
10 — ENG Extension Cord Wir e Gauge Chart Amperage *Up to 20 amp draw Up to 30 amp draw Cord Length 0 to 100 ft. 0 to 100 ft. Wire Gauge Size 12 ga. 10 ga. *NOTE: When amperage exceeds 20 amps; a 12 gauge extension cord should not be used for long dis- tances. Extension Cords When using an appliance or tool at a considerable dis- tance from the g ...
-
Porter-Cable H451CS - page 11
11 — ENG OPERA TION KNOW YOUR GENERA TOR Read this General Manual and Safety Rules before operation of your Generator . Compare the illustration in your parts manual with your generator to familiarize yourself with the location of various controls and ad- justments. Save all manuals for future r eferences. GENERA TOR CAP ACITY IMPORT ANT : Exceed ...
-
Porter-Cable H451CS - page 12
12 — ENG Never fill fuel tank indoors. Never fill fuel tank when engine is running or hot. Do not smoke when filling fuel tank. Never run engine indoors or in enclosed, poor ventilated areas, engine exhaust contains car- bon monoxide, an odorless and deadly gas. 3. Make sure generator is gr ounded in accordance with local requir ements. 4. All el ...
-
Porter-Cable H451CS - page 13
13 — ENG TO ST ART THE ENGINE Never run engine indoors or in enclosed, poor ventilated areas, engine exhaust contains carbon monoxide, an odorless and deadly gas. 1. Open the fuel shut-off valve on tank and engine. 2. Move the choke control located on the engine to "CHOKE" position. NOTE: No choke is requir ed on warm engines. Make sure ...
-
Porter-Cable H451CS - page 14
14 — ENG MAINTENANCE GENERAL RECOMMENDA TIONS The warranty of the generator does not cover items that have been subjected to operator abuse or negli- gence. T o receive full value from the warranty , operator must maintain the generator as instructed in this manu- al. ENGINE MAINTENANCE Refer to the Engine Operator's manual for service and m ...
-
Porter-Cable H451CS - page 15
15 — ENG STORAGE If you are going to stor e your generator for more than 30 days, use the following information as a guide to prepar e the generator for storage. Never store generator with fuel in the tank in- doors or in enclosed, poorly ventilated areas, where fumes can r each an open flame, spark or pilot light as on a furnace, water heater , ...
-
Porter-Cable H451CS - page 16
16 — ENG Never exceed the rated capacity of your generator . Serious damage to the generator or appliance could result fr om an overload. 1. Starting and running wattage requir ements should always be calculated when matching a generators wattage capacity to the appliance or tool. 2. There ar e two types of electrical appliances that can be power ...
-
Porter-Cable H451CS - page 17
17 — ENG ST AR TING W A TT AGE REQUIREMENTS 1. Some appliances and tools will list on the motor name plate the starting and running voltage and amperage requir ements. Use the following formula to convert voltage and amperage to wattage: V olts X Amp = W atts 120 volts x 10 amps = 1200 watts 2. T o determine the approximate starting wattage requi ...
-
Porter-Cable H451CS - page 18
18 — ENG HOUSEHOLD W A TT AGE CALCULA TOR W A TT AGE CALCULA TIONS APPLIANCE OR LOAD DEVICE* REFRIGERA TOR/ FREEZER 800 SMALL REFRIGERA TOR AIR COND.(ROOM) SUMP PUMP 1/2 HP 600 TELEVISION CAUTION !! HOT PLA TE MICROWA VE SP ACE HEA TER 2400 1000 3 2 LIGHTING 60 WA TT BULBS 75 WA TT BULBS 100 WA TT BULBS 300 WA TT BULBS ELECTRIC LOAD GRAND TOT AL ...
-
Porter-Cable H451CS - page 19
19 — ENG PROBLEM CAUSE CORRECTION TROUBLESHOOTING GUIDE Engine will not start No electrical output Repeated circuit breaker tripping Generator overheating 1. Low on fuel or oil. 2. Ignition switch in "Of f" position. 3. Faulty spark plug. 4. Choke in wr ong position. 5. Fuel shut-of f valve in closed position. 6. Unit loaded during star ...
-
Porter-Cable H451CS - page 20
Porter -Cable Corporation 4825 Highway 45 North P .O. Box 2468 Jackson, TN 38302-2468 1-888-559-8550 AL WA YS REFER TO THE MANUALS SUPPLIED WITH THIS UNIT Generator Quick Facts CALL 1-888-559-8550 TO FIND A LOCAL AUTHORIZED SERVICE CENTER NEAR YOU FOR REP AIRS AND SERVICE P ART PURCHASES ENGINE GAS ENGINE OIL WA T T A G E WIRING BA TTERY VOL T REG. ...
¿Tienes una pregunta acerca de Porter-Cable H451CS?
Utiliza el formulario que se encuentra abajo
Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Porter-Cable H451CS, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Porter-Cable H451CS probablemente compartirá una forma de solucionarlo.