Manual de instrucciones SRS Labs SR785

14 de páginas 0.3 mb
Descargar

Pasar a la página of 14

Summary
  • SRS Labs SR785 - page 1

    SR785 T wo Channel Dynamic Signal Analyzer SRS STANFORD RESEARCH SYSTEMS ...

  • SRS Labs SR785 - page 2

    SR785 T wo Channel Dynamic Signal Analyzer $11,950 (U.S. list) Features ● FFT , Correlation and Order T racking Measurements ● ANSI Standard 1/1, 1/3, 1/12 Octave Analysis ● Swept-Sine Mode (145 dB dynamic range) ● 20-pole/20-zero Curve Fit and Synthesis ● Time/Histogram Mode ● Windows95 ¨ DataViewer ● Output to SDF ¨ , MA T ¨ , UF ...

  • SRS Labs SR785 - page 3

    F ast Responsive Mark er • Find Max/Min or track peaks • THD, THD + N • Band, sideband, harmonic power • Waterfall • Frequency and damping • Peak find • Absolute and relative • Statistics Input Channels • Dual ADCs provide 102.4 kHz bandwidth on both channels simultaneously. • -50 dBV max full scale input sensitivity • Built-i ...

  • SRS Labs SR785 - page 4

    SR785 T wo Channel Dynamic Signal Analyzer FFT Spectrum Analysis The SR785 Two Channel Dynamic Signal Analyzer is a precision, full-featured signal analyzer that offers state-of-the-art performance and a wide selection of features at a price that's less than half that of competitive analyzers. Building on its predecessor, the SR780, the SR785 ...

  • SRS Labs SR785 - page 5

    View order maps or track individual orders with the SR785. Run-up and run-down measurements in both polar and bode formats are available. time record, 1000 averages take exactly 4 seconds, during which the SR785 still operates at its maximum display rate. For impact testing, the average preview feature allows each time record or spectrum to be acce ...

  • SRS Labs SR785 - page 6

    provided to monitor variations of RPM as a function of time. And a complete selection of time and RPM triggering modes is included allowing you to make virtually any rotating machinery measurement. Swept-Sine Measurements Network analysis using FFT mode produces fast results but suffers from limited dynamic range and frequency resolution. Swept-sin ...

  • SRS Labs SR785 - page 7

    Top display shows the burst noise source. Bottom display shows an arbitrary waveform downloaded to the SR785 via the IEEE-488 interface. Top display shows a histogram of time data. Bottom display shows the cumulative density function. user-defined thresholds are measured with high frequency resolution, while small changes are measured using wider f ...

  • SRS Labs SR785 - page 8

    Two 2k deep waterfall buffers ensure you’ll never miss important waterfall data. The SR785 doesn’t limit you to a few preselected measurements. With user math you can create an infinite variety of measurements. Wa t e r f a l l Waterfall plots are a convenient way of viewing a time history of your data. Each successive measurement record is plo ...

  • SRS Labs SR785 - page 9

    Output The SR785's built-in 3.5" 1.44 MB disk drive, GPIB and RS-232 computer interfaces and Centronics printer port combine to allow almost unlimited flexibility in saving, printing, plotting or exporting your measurement data. Displays and setups can be printed or plotted to disk, GPIB, RS-232 or Centronics port in PCX, GIF, PCL (LaserJ ...

  • SRS Labs SR785 - page 10

    The SRS DataViewer Windows utility enables you to view SR785 data files graphically and save them in different formats. DataViewer The SRS DataViewer is a Windows 95 program that allows you to quickly upload SR785 files into a graphical environment, perform simple editing and cut and paste into other applications. You can add pointers and text, cha ...

  • SRS Labs SR785 - page 11

    SR785 Specifications Specifications apply after 30 minutes of warm-up and within two hours of last auto-offset. All specifications are with 400 line FFT resolution and anti-alias filters enabled unless stated otherwise. Measurement Groups Standard Groups FFT analysis, Correlation, Time Histogram, Swept Sine Optional Group Order Tracking Frequency R ...

  • SRS Labs SR785 - page 12

    Flatness <0.25 dB pk-pk (typical), <1.0 dB pk-pk (max), 5000 rms averages Pink Noise Source Bandwidth DC to 102.4 kHz Flatness <2.0 dB pk-pk, 20 Hz - 20 kHz (measured using averaged 1/3 octave analysis) Chirp Source Time Record Continuous or Burst Output Sine sweep across the FFT span Flatness ±0.25 dB, 1.0 Vpk Swept Sine Source Auto Func ...

  • SRS Labs SR785 - page 13

    SR785 Features Instrument Modes FFT, Time/Histogram, Correlation, Octave, Swept-Sine, Order Tracking Frequency Domain Measurements Frequency Response, Linear Spectrum, Cross Spectrum, Power Spectrum, Coherence, Power Spectral Density Time Domain Measurements Time Record, Cross Correlation, Auto Correlation, Orbit Amplitude Domain Measurements Histo ...

  • SRS Labs SR785 - page 14

    1290 D Reamwood Avenue ¥ Sunnyvale, CA 94089 Telephone (408)744-9040 ¥ FAX: (408)744-9049 Email: info@srsys.com ¥ WWW: www.srsys.com Printed in USA ©1998 Stanford Research Systems, Inc. All specifications and prices subject to change (1/98) All trademarks are the property of their respective owners. SRS STANFORD RESEARCH SYSTEMS Ordering Inform ...

Fabricante SRS Labs Categoría Stereo System

Los documentos del dispositivo SRS Labs SR785 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos SRS Labs
- manuales de instrucciones SR785
- hojas de producto SRS Labs
- folletos informativos
- o etiquetas energéticas SRS Labs SR785
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones SRS Labs SR785.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje SRS Labs SR785, instrucciones de servicio, instrucciones cortas o instrucciones de usuario SRS Labs SR785. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto SRS Labs SR785.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo SRS Labs SR785, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar SRS Labs SR785. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de SRS Labs SR785.

El manual de instrucciones completo de SRS Labs debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual SRS Labs SR785 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice SRS Labs SR785, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de SRS Labs SR785 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo SRS Labs SR785 - que deben facilitarnos los primeros pasos durante el uso de SRS Labs SR785
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con SRS Labs SR785
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de SRS Labs SR785 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de SRS Labs SR785?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con SRS Labs SR785, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con SRS Labs SR785 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)