    USSC 1 CAUTION: READ ALL INSTRUCTIONS CARE- FULLY BEFORE STARTING THE INSTALLATION OR OPERATING THE HEATER IMPROPER INSTALLATION MAY VOID YOUR WARRANTY DO NOT USE THIS HEATER IN A MOBILE HOME OR TRAILER 851523 C R US UNITED STATES STOVE COMPANY 227 Industrial Park Road P.O.Box 151 South Pittsburg, TN 37380 (423) 837-2100 Owner’s Manual 4027 & ...

  • United States Stove 4027 - page 2

    2 USSC SAFETY PRECAUTIONS PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW HEATING APPLIANCE. FAIL- URE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. THIS HEATING APPLIANCE SHOULD BE INSTALLED ONLY BY AN EXPERIENCED COAL HEATER INSTALLER. IF THIS HEATING APPLIANCE IS NOT PROPERLY INSTALLED, A ...

  • United States Stove 4027 - page 3

    USSC 3 Before Assembly, inspect the heater thoroghly for missing parts or shipping damage. If any damage or missing parts are detected, report it to your heater dealer. DO NOT INSTALL OR USE A DAMAGED OR INCOMPLETE HEATER Shaker Handle Assembly: 1. First, remove the two(2) bolts from the left side of the unit where the shaker handle is to be mounte ...

  • United States Stove 4027 - page 4

    4 USSC FIGURE 1 - MASONRY CHIMNEY REQUIREMENTS FLUE MINIMUM 1/2" AIR SPACE FOUNDATION CHIMNEY WALL 4" NOMINAL 5/8" FIRECLAY OR STAINLESS STEAL FLUE LINER If the heater is to be connected to a masonry chimney, the heater should not be installed until it is determined that the chimney is safe for use. Before installing the heater, have ...

  • United States Stove 4027 - page 5

    USSC 5 FIGURE 4- CHIMNEY HEIGHT REQUIREMENTS A Chimney must be the required height above the roof or other obstruction for safety and for proper draft op- eration. The requirement is that the chimney must be at least 3 feet higher than the highest point where it passes through the roof and at least 2 feet higher than the high- est part of the roof ...

  • United States Stove 4027 - page 6

    6 USSC Figure 5 shows how to connect the chimney connector of a heater to a masonry chimney through a combustible wall. There are five allowable ways that a chimney connector can be connected to a masonry chimney by passing through a combustible wall. NFPA Standard 211 allows the following wall pass-through systems. MASONRY CHIMNEY CONSTRUCTED TO N ...

  • United States Stove 4027 - page 7

    USSC 7 CHIMNEY FLUE MINIMUM CHIMNEY CLEARANCE TO BRICK AND COMBUSTIBLES IS 2 IN. MINIMUM CLEARANCES 12 IN. OF BRICK ALL AROUND CHINEY CONNECTOR TO HEATER FIRE CLAY LINER (5/8" MIN. WALL THICKNESS) MIN. 3-1/2" THICK BRICK MASONRY WALL MASONRY CHIMNEY CONSTRUCTED TO NFPA 211 MINIMUM 12 IN. TO COMBUSTIBLES PART A, FIGURE 5 (FIGURE 5 CONTIUED ...

  • United States Stove 4027 - page 8

    8 USSC PART E - (Figure 5) In addition to the methods shown by A, B, C, and D of Figure 5, a listed factory-built wall pass-through system may be purchased and installed according to the instructions packaged with it to provide a safe method of passing chimney connector through a combustible wall for a connection to a masonry chimney. If the chimne ...

  • United States Stove 4027 - page 9

    USSC 9 METAL PREFABRICATED CHIMNEY REQUIREMENTS Any metal prefabricated chimney that this heater is connected to must be a Listed High Temperature Type 103-HT Factory- Built Residential Type and Building Heating Appliance Chimney. Its interior size should be no smaller than 6 inches in diameter or no larger than 8 inches in diameter. An undersized ...

  • United States Stove 4027 - page 10

    10 USSC COMBUSTIBLE CEILING JOIST SPECIFIED CLEARANCE INSULATION SHEILD LISTED CHIMNEY TO HEATER CEILING SUPPORT CHIMNEY CONNECTOR ROOF FLASHING STORM COLLAR CHIMNEY CAP (WITH SPARK ARRESTER IF DESIRED OR WHERE REQUIRED BY LAW.) MAINTAIN 2 INCH CLEARANCE LISTED CHIMNEY CEILING CEILING SUPPORT CHIMNEY CONNECTOR TO HEATER WALL FLOOR PROTECTOR FIGURE ...

  • United States Stove 4027 - page 11

    USSC 11 SECTION LISTED CHIMNEY PIPE TO HEATER TRIM COLLAR ON INSIDE WALL CHIMNEY CONNECTOR LISTED CHIMNEY INSULATED "T" WALL SUPPORT WALL SPACER ON OUTSIDE WALL 2" CLEARANCE (BETWEEN WALL AND CHIMNEY) COMBUSTIBLE OUTSIDE WALL CHIMNEY CAP (WITH SPARK ARRESTER IF DESIRED OR WHERE REQUIRED BY LAW.) ROOF FLASHING STORM COLLAR MAINTAIN 2 ...

  • United States Stove 4027 - page 12

    12 USSC HEATER INSTALLATION CAUTION: FOR YOUR SAFETY, THE INSTALLATION OF THIS HEATER MUST COMPLY WITH LOCAL CODES AND REGULATIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT INSPECTION TO ASSURE PROPER COMPLIANCE WITH LOCAL CODES AND REGULATIONS. MINIMUM CLEARANCES TO COMBUSTIBLE WALL AND CEILINGS CAUTION: MOST WALLS AND CEILINGS CONTAIN WOOD ...

  • United States Stove 4027 - page 13

    USSC 13 FIGURE 9 - PLAN VIEWS SHOWING FLOOR PROTECTOR'S MINIMUM SIZE (DIMENSIONS IN INCHES) Masonry, or other non-combustible products, attached directly to a combustible surface without an air space offer very little protection and cannot be considered a clearance reducer unless specified materials have been tested and listed for direct attac ...

  • United States Stove 4027 - page 14

    14 USSC 6. Place the crimped end of the first chimney pipe or elbow into the heater's flue collar and mark it through each of the holes in the heater's flue collar. 7. Remove the pipe or elbow from the flue collar and drill 1/8 - inch diameter holes at the points marked. 8. Apply the furnace to the inside surface of the heater's flue ...

  • United States Stove 4027 - page 15

    USSC 15 OPERATING INSTRUCTIONS Burning Coal in your 4027/ASA7 Your Wondercoal is capable of burning both bituminous and Anthracite coal. Anthracite is the best coal fuel because its long even burn time, high heat output, and cleanliness make it a good choice for the home. However, keep in mind it is a much more difficult fuel to use and requires mo ...

  • United States Stove 4027 - page 16

    16 USSC CAUTION! ASHES SHOULD NEVER BE ALLOWED TO ACCUMULATE ABOVE THE TOP OF THE ASH PAN. ASHES IN CONTACT WITH THE BOTTOM OF THE GRATES ACT AS AN INSULATOR, INTENSIFYING THE HEAT ON THE GRATES AND COULD CAUSE THEIR WARPAGE. WITH AN EXCESSIVE ASH BUILDUP, PRIMARY COMBUSTION AIR IS RESTRICTED, THUS THE UNIT’S OUTPUT COULD BE REDUCED. GRATES DAMAG ...

  • United States Stove 4027 - page 17

    USSC 17 OPERATING INSTRUCTIONS continued... Before opening the loading door, open the pipe damper and the ash door first. Whenever a loading door is opened, it always should be cracked slightly to allow oxygen to enter and burn any combus- tion gases that are present before fully opening. Failure to do this could result in sudden ignition of the un ...

  • United States Stove 4027 - page 18

    18 USSC 1 2 3 4 56 7 89 10 12 11 13 16 19 14 15 18 20 17 15 16 26 25 24 20 21 22 23 4027 & ASA7 Repair Parts ...

  • United States Stove 4027 - page 19

    USSC 19 MODEL 4027 & ASA7 - PARTS LIST KEY PART NO. DESCRITION QTY. 1 40422 Cast Iron Legs 4 • 83507 3/8-16 x 1-1/4 Bolt 4 2 25096 Flue Collar 1 • 83431 Weld Tab 3 • 83045A Washer 3/8 i.d._7/8 o.d. 3 • 83432 5/16-18 x 1-1/2 Hex Bolt 3 3 25080B Door Latch 2 • 83508 5/16- 18 x 3/4 Bolt 2 • 83338 5/16- 18 Lock Nut 2 4 69338B S h a k e ...

  • United States Stove 4027 - page 20

    20 USSC THIS MANUAL WILL HELP YOU OBTAIN EFFICIENT, DEPEND- ABLE SERVICE FROM YOUR HOTBLAST FURNACE, AND EN- ABLE YOU TO ORDER REPAIR PARTS CORRECTLY. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFER- ENCE. WHEN WRITING, ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER. WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE ...

Fabricante United States Stove Categoría Air Conditioner

Los documentos del dispositivo United States Stove 4027 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos United States Stove
- manuales de instrucciones 4027
- hojas de producto United States Stove
- folletos informativos
- o etiquetas energéticas United States Stove 4027
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones United States Stove 4027.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje United States Stove 4027, instrucciones de servicio, instrucciones cortas o instrucciones de usuario United States Stove 4027. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto United States Stove 4027.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo United States Stove 4027, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar United States Stove 4027. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de United States Stove 4027.

El manual de instrucciones completo de United States Stove debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual United States Stove 4027 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice United States Stove 4027, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de United States Stove 4027 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo United States Stove 4027 - que deben facilitarnos los primeros pasos durante el uso de United States Stove 4027
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con United States Stove 4027
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de United States Stove 4027 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de United States Stove 4027?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con United States Stove 4027, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con United States Stove 4027 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)