Manual de instrucciones Honeywell L404A-D

10 de páginas 0.89 mb
Descargar

Pasar a la página of 10

Summary
  • Honeywell L404A-D - page 1

    I I i i I I Honeywell L404A D F L604A L M Pressuretrol@ Controllers IA04 and L604 PressuretrofFJ Con trollers are li7J evoltage pressure controllers thatprovide oper ating control automatic limit protection ormanual reset limit protection for pressure systems of up to 300 psi 21 1 kglcm2 or 2068 kpa Ii Can be used with steam air non combustible gas ...

  • Honeywell L404A-D - page 2

    04A D F L604A L M JECIFICATIONS ORDERING INFORMATION TRADELINE@ MODELS TRADELINE@ models are selected and packaged to provide ease of stocking ease of handling and maximum replacement value Specifications of TRADELlNE@ con trols are the same as those of standard models except as noted below TRADELINE@ MODELS A V All ABLE L604A Pressuretrol@ Control ...

  • Honeywell L404A-D - page 3

    L404A D F L604A L M SPECIFICATIONS I I I Switching Midscale Subtractive Differential a Maximum Surge Action on Pressure Rise Operating Ranges a Adjustable Pressure Model to Setpoint psi kglem2 kPa psi kgfcm2 kPa psi kglem2 kPa L404A spst breaks 2to 15b c 14to1 0 14 to 103 2to6 14 to 41 14to4 35 345 circuit 5 to 50 35 to 3 5 34 to 345 4 to 12 28 to ...

  • Honeywell L404A-D - page 4

    404A D F L604A L M JPECIFICA nONS DIMENSIONS See Fig 1 See Fig 2 for mounting s trap siphon loop WEIGHT 2 me 0 91 kg FINISH Gray APPROVALS Underwriters Laboratories Inc listed IA04 A B C D F L604A L M only file no MP466 v01 l0 guide no MBPR Canadian Standards Association certified LA04A B C D F L604A L only file no LR1620 guide noAOO E O REPLACEMEN ...

  • Honeywell L404A-D - page 5

    l404A D F l604A l M INSTALLATION Installation WHEN INSTALLING TIllS PRODUCT 1 Read these instructions carefully Failure to follow them could damage the product or cause a hazardous condition 2 Check the ratings given in the instructions and on the prod ct to make sure the product is suitable for your application 3 Installer must be a tramed expenen ...

  • Honeywell L404A-D - page 6

    L404A D F L604A L M INSTALLATION Mounting on a Boiler If it is not convenient to mount the controller alongside the pressure gauge install a steam trap siphon loop in the fitting provided by the boiler manufactUrer If there is no fitting mount the steam trap at a location recommended by the boiler manufacturer Screw the controller directly to the s ...

  • Honeywell L404A-D - page 7

    Fig 6 l404 with a low voltage relay LOW VOLTAGE RELAY 24 VOLT THERMOSTAT L1 HOT POWER 1 SUPPLY a L2 LOAD PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED M8940 Fig 7 l404F l604A Oump r installed used as a high limit with an alarm circuit SPOT CONTROUER LOW UMfT Ll HOT POWER SUP PLY 12 FlAME SAFEGUARD CONTROL MOTOR OR OTHER LOAD PROVIDe ...

  • Honeywell L404A-D - page 8

    04A D F L604A L M ETTING AND CHECKOUT Setting and Checkout SETIING In all models the differential is subtractive from the main scale set point The upper operating point is deter mined by the main scale set point while the lower operat ing point is determined by the main scale setting less the differential setting The L404F and L604A with jumper ins ...

  • Honeywell L404A-D - page 9

    Boiler Installation If the controller is being used on a boiler installation test it as follows 1 Note the boiler pressure by checking the boiler pres sure gauge To perform this testproperly the boiler should have a pressure reading near the middle of the controller s main scale range 2 Turn the main scale adjusting screw Fig 11 until the m rlnscal ...

  • Honeywell L404A-D - page 10

    Q4A D F L604A L M RVICE INFORMATION Service Information CALmRATION The controller was carefully calibrated during manufac turing and should not require recalibration Most calibra tion errors are caused by improper leveling The controller should be level when the pointer on the leveling indicator is directly over the index mark Fig 11 In some cases ...

Fabricante Honeywell Categoría Sleep Apnea Machine

Los documentos del dispositivo Honeywell L404A-D que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Honeywell
- manuales de instrucciones L404A-D
- hojas de producto Honeywell
- folletos informativos
- o etiquetas energéticas Honeywell L404A-D
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Honeywell L404A-D.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Honeywell L404A-D, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Honeywell L404A-D. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Honeywell L404A-D.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Honeywell L404A-D, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Honeywell L404A-D. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Honeywell L404A-D.

El manual de instrucciones completo de Honeywell debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Honeywell L404A-D - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Honeywell L404A-D, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Honeywell L404A-D que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Honeywell L404A-D - que deben facilitarnos los primeros pasos durante el uso de Honeywell L404A-D
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Honeywell L404A-D
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Honeywell L404A-D en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Honeywell L404A-D?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Honeywell L404A-D, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Honeywell L404A-D probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen