    Manufactu rer reser ves the rig ht to dis continue , or chan ge at a ny time, spec ificat ions or des igns without notice an d withou t inc urring obligations. PC 111 Catalo g No. 533-80003 Pr inted in U.S.A. For m 38A -9SI Pg 1 5-01 Replac es: 38A-8 SI Book 1 4 Ta b 3 a 2 a Installation, Star t-Up and Ser v ice Instr u ctions CONTENTS Pa ge SAFETY ...

  • Carrier 38AKS009 - page 2

    2 Table 1A — P hysical Da ta — 50/60 Hz (English) LEGE ND NEMA — National Electrical M anuf acturing Assoc iation *Unit is factory supplied w ith holding charge only . †Storage capacity of condenser coil with coil 8 0% full of liquid R-22 at 124 F . NO TE: Unit 38AKS012 has one step o f unloading. Full load is 100% capac ity , and one step ...

  • Carrier 38AKS009 - page 3

    3 Table 1B — P hysical D ata — 50/6 0 Hz (SI) LEGE ND NEMA — National Electrical M anuf acturing Assoc iation *Unit is factory supplied w ith holding charge only . †Storage capacity of condens er coil with coil 8 0% full of liquid R-2 2 at 51 C. NO TES: 1. Unit 38AKS012 has one step of unloading. Full load is 100% capacity , and one step of ...

  • Carrier 38AKS009 - page 4

    4 CONSIDER SYSTEM REQUIR EMENTS • Consult local bu ilding codes and NEC for s pecial instal- lation requirem ents. • Allow sufficient space for airflow clearan ce, wiring, refriger ant pipi ng, and u nit ser vicing . See Fig. 2. • Locate unit so that co ndenser airflow is unrestricted o n all sides and abov e. Refer to Fig. 2. • Unit may be ...

  • Carrier 38AKS009 - page 5

    5 UNIT 38 DIM. A DIM. B DIM. C DIM. D DIM . E DIM. F AK007 1 ′ -6 1 / 2 ″ [470.0] 1 ′ -2 3 / 4 ″ [375.0] — — 1 ′ -2 1 / 4 ″ [362 ] 1 ′ -4 5 / 16 ″ [415 ] 2 ′ -9 5 / 16 ″ [846.5] AK008 1 ′ -8 ″ [508.0] 1 ′ -6 1 / 2 ″ [470.0] — — 1 ′ -3 ″ [381 ] 2 ′ - 5 / 16 ″ [613 ] 3 ′ -5 7 / 16 ″ [1052.5] AK012 1 ′ ...

  • Carrier 38AKS009 - page 6

    6 FIL TER DRIER AND MOIS TURE INDICA TOR — The fil- ter drier is factory installed. M oisture indicator is field-supplied and should be installed just after liquid line shutof f valve. Do not use a r eceiver; there is none provided with unit and one should not be used. NOTE: Unit is shipped with R-22 holding charge. System pressure must be reliev ...

  • Carrier 38AKS009 - page 7

    7 Table 5 — E lectrical Data LEGEND NO TES: 1. In compliance with NEC requirem ents f or multimotor and combi- nation load equipment (ref er to NEC Ar ticles 430 and 440) , the ov erc urrent protective de vice f or the unit shall be fuse or HACR breaker . 2. Unbalanc ed 3- Phas e Suppl y V oltage Nev er operate a motor where a phase imbalan ce in ...

  • Carrier 38AKS009 - page 8

    8 FI E L D CO N T R O L WI R I NG — Install a Carri er-approved accessor y thermostat a ssembly ac cording to install ation instructi ons included with t he access ory . L ocate the rmostat assembly on a solid wall i n the conditioned spa ce to sense ave r- age temperatur e in accorda nce with therm ostat ins tallation instructions. Route thermos ...

  • Carrier 38AKS009 - page 9

    9 ST ART -UP Preliminary Chec ks 1. Field electrical power source must agree with unit name- plate rating. 2. Check that all internal wiring conne ctions are tight and that all barriers, covers, and pane ls are in place. Ensure no electrical wir es are in contact wit h refrigerant tubing. 3. Ensure all service valves are open. On 38AKS units, be su ...

  • Carrier 38AKS009 - page 10

    10 Compressor Overload — This overload interrupts power to t he compress or when either the current or internal motor winding temperature be comes excessive, and automati- cally res ets when t he inte rnal tem perature drops t o a safe l evel. This overload may require up to 60 minutes (or longer) to reset. If the internal overload is suspected o ...

  • Carrier 38AKS009 - page 11

    11 Oil Char g e (T ables 1A and 1 B) 38 A KS U NI T S — Allow unit to run for about 20 minutes. Stop unit and che ck compressor oil level . Add oil only if neces- sary to bring oil into view in sight glass. Use on ly Ca rr ier- appr oved compr ess or oil. Approved oils are: Suniso 3GS WF32-150 38 A K UN I T S — The 38AK units do not have a sigh ...

  • Carrier 38AKS009 - page 12

    12 Capacity Contr ol — Unit 38AKS012 Onl y — A suction pressure-actuated unl oader controls 2 cylinders and provides capacity control. Unloaders are fac tory set (see T able 1A or 1B), but may be field adjusted as follows: CONTROL SET POINT (cylinder l oad point) is adjustabl e from 0 to 85 psig (586 kPa). T o adjust, turn control set point adj ...

  • Carrier 38AKS009 - page 13

    13 TROUBLESHOO TING GUIDE NO TE: See Fig. 15 f or component arrangements. SYMPTOM CA U SE REME D Y Compressor does not run — Contactor open P ower off . Restore power . Fuses blo wn. Replace with correct fuses after finding cause and correcting. T ransformer open/shor t ed. Replace transformer if primar y windings are receiving power and no outpu ...

  • Carrier 38AKS009 - page 14

    Manufactu rer reser ves the rig ht to dis continue , or chan ge at a ny time, spec ificati ons or des igns without notice an d wit hout inc urring obligations. PC 111 Catalo g No. 533-80003 Pr inted in U.S.A. For m 38 A-9SI Pg 14 5-01 Replac es: 38A -8SI Book 1 4 Ta b 3 a 2 a Copyright 20 01 Car rier Cor po ration C— Contactor , Compressor CAP ? ...

  • Carrier 38AKS009 - page 15

    ST ART -UP CHECKLIST I. Preliminary Inf ormation OUTDOOR: MO DEL NO . _________ ______________ ________ SERIAL NO . _____________ ______________ _________ INDOOR: AIR HANDLER MANUF ACTURER ________ _____________________ ______________ ______________ _________ MODEL NO ._____ ______________ ______________ _ SERIAL NO . ______ _____________________ _ ...

  • Carrier 38AKS009 - page 16

    Manufactu rer reser ves the rig ht to dis continue , or chan ge at a ny time, spec ificati ons or des igns without notice an d wit hout inc urring obligations. PC 111 Catalog No. 533-80003 Printe d in U.S.A. Form 38A-9S I Pg CL -2 5-0 1 Replaces: 3 8A-8 SI Book 1 4 Ta b 3 a 2 a Copyright 20 01 Car rier Cor po ration - - - - - - - - - - - - - - - - ...

Fabricante Carrier Categoría Clothes Dryer

Los documentos del dispositivo Carrier 38AKS009 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Carrier
- manuales de instrucciones 38AKS009
- hojas de producto Carrier
- folletos informativos
- o etiquetas energéticas Carrier 38AKS009
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Carrier 38AKS009.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Carrier 38AKS009, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Carrier 38AKS009. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Carrier 38AKS009.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Carrier 38AKS009, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Carrier 38AKS009. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Carrier 38AKS009.

El manual de instrucciones completo de Carrier debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Carrier 38AKS009 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Carrier 38AKS009, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Carrier 38AKS009 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Carrier 38AKS009 - que deben facilitarnos los primeros pasos durante el uso de Carrier 38AKS009
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Carrier 38AKS009
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Carrier 38AKS009 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Carrier 38AKS009?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Carrier 38AKS009, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Carrier 38AKS009 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)