    1 PLACE THESE INSTRUCTIONS ADJACENT TO HEA TER AND NOTIFY OWNER T O KEEP FOR FUTURE REFERENCE. PRINTED 0409 315931-000 RUF 100 199 SERIES 100 AND 101 COMMERCIAL GAS W A TER HEA TER GAS-FIRED POWER BURNER FOR DOMESTIC HOT W A TER Thank you for buying this energy efcient water heater . We appreciate your condence in our products. CAUTION TEXT P ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 2

    2 These designs comply with the current version of the American National Standard for Gas Water Heaters, Volume III, ANSI Z21.10.3 / CSA 4.3 as an automatic circulating tank water heater , and automatic storage water heaters. Detailed installation diagrams are found in this manual. These diagrams will serve to provide the installer with a reference ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 3

    3 DANGER THIS W A TER HEA TER IS EQUIPPED WITH AN ADJUST ABLE THERMOST A T TO CONTROL W A TER TEMPERA TURE. HOT W A TER TEMPERA TURES REQUIRED FOR AUTOMA TIC DISHWASHER AND LAUNDRY USE CAN CAUSE SCALD BURNS RESUL TING IN SERIOUS PERSONAL INJURY AND/OR DEA TH. THE TEMPERA TURE A T WHICH INJURY OCCURS V ARIES WITH THE PERSON’S AGE AND THE TIME OF T ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 4

    4 temperature be set for the lowest temperature which satises your hot water needs. This will also provide the most energy efcient operation of the water heater and minimize scale formation. SETTING THE W A TER HEA TER TEMPERA TURE A T 120°F/49°C WILL REDUCE THE RISK OF SCALDS. Some states require settings at specic lower temperatures. F ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 5

    5 LOCA TING THE HEA TER W ARNING THERE IS A RISK IN USING FUEL BURNING APPLIANCES SUCH AS GAS WA TER HEA TERS IN ROOMS, GARAGES OR OTHER AREAS WHERE GASOLINE, OTHER FLAMMABLE LIQUIDS OR ENGINE DRIVEN EQUIPMENT OR VEHICLES ARE STORED, OPERA TED OR REP AIRED. FLAMMABLE V APORS ARE HEA VY AND TRA VEL ALONG THE FLOOR AND MA Y BE IGNITED BY THE HEA TER? ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 6

    6 If the conned space is within a building of tight construction, air for combustion and ven til at ion mus t be o bta ine d fr om o utd oor s. When dire ct ly co mm uni cat in g with the outdoors through vertical ducts, two permanent openings, located in the above manner , should be provided. Each opening should have a free area of not less tha ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 7

    7 For all side wall terminated, horizontally vented power vent, direct vent, and power direct vent gas fueled water heaters installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7 ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 8

    8 FIGURE 5. U.S. POWER VENT CAUTION TO PREVENT EXHAUSTING PRODUCTS FROM CIRCULA TING T O THE AIR INT AKE IN WINDY/COLD AREAS, THE MAXIMUM PRACTICAL DIST ANCE BETWEEN THESE TWO TERMINALS IS RECOMMENDED. FIGURE 6. U.S. DIRECT VENT CAUTION TO PREVENT EXHAUSTING PRODUCTS FROM CIRCULA TING T O THE AIR INT AKE IN WINDY/COLD AREAS, THE MAXIMUM PRACTICAL D ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 9

    9 IMPORT ANT The vent system must terminate so that proper clearances are maintained as cited in local codes or the current editions of the National Fuel Gas Code, ANSI Z223.1/NFP A 54. Do no t te rmi nat e the exh aus t ven t te rmi nal over publ ic area wher e co nde nsa te or vapor can cause nuisance or hazard. Plan the vent system layout so tha ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 10

    10 5. Glue the intake vent terminal to the section of the pipe. 6. Slide the wall plate over the pipe to stop against intake vent terminal. 7. Place a bead of caulking (not supplied) around the gap between the pipe and the wall. Place some of the caulking on the back of the plate to hold it against the wall after installation. 8. If the vent pipe i ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 11

    11 NOTE: for W ater Heaters in loca tions with high ambient temperatures (above 100°F or 38°C) and/or insufcient dilution air , it is recommended that CPVC or ABS pipe and ttings ( MUST USE SUPPLIED VENT TERMINAL ) be used. 4. It is important that condensate not be allowed to buildup in the exhaust vent pipe . T o pre vent this from happeni ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 12

    12 LOW GAS PRESSURE SWITCH (SEE FIGURE 12) The Low Gas Switch (LGS) is a single-pole, normally open pressure switch that will close its contacts when a rising pressure of 5.0 in. (1.25Kpa) W .C. is encountered. The contacts will open when the pressure falls below the xed set point of 4.8"WC (1.18Kpa) for natural gas models and 8.5"WC ( ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 13

    13 W ARNING T H E H E A T E R I S N O T I N T E N D E D F O R O P E R AT I O N AT H I G H E R T H A N 10. 5" ( 2. 5 9 K Pa) WATER CO LU M N SUP PL Y G A S PR ES SU R E. H I G HE R G AS S U P PL Y PR E S S U R ES R EQ U I R E S U PP L EM EN TAL R E D U CI N G SERV ICE REGU L A TIO N. E X PO SUR E TO HI GH ER G AS S UPPL Y PR E S SU R E M AY CAU ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 14

    14 DISCONNECT THE APPLIANCE AND ITS MANUAL GAS SHUTOFF V AL VE FROM THE GAS SUPPL Y PIPING SYSTEM DURING ANY SUPPL Y PRESSURE TESTING EXCEEDING 1/2 PSIG (3.45Kpa). GAS SUPPL Y LINE MUST BE CAPPED WHEN DISCONNECTED FROM THE HEA TER. FOR TEST PRESSURES OF 1/2 PSIG (3.45Kpa) OR LESS, THE APPLIANCE NEED NOT BE DISCONNECTED, BUT MUST BE ISOLA TED FROM T ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 15

    15 CA N CAUS E TH E CO NTR OLL ER TO M ALF UN CTIO N. A HIG H QUA LIT Y P OWER CON DI TIO NER MUST B E I NST AL LED IF THE AB OVE C ON DIT IO NS E X IST . MA LFU NCT IO NS CAU SED BY A PO OR E LECTRI CA L SU PPL Y AR E NOT C OVER ED U ND ER YOUR W A R R A N T Y. T he c o n t ro l l e r i s w ir e d to t h e he a te r a s s h o wn i n Fi g ur e 15 . ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 16

    16 USING THE ELECTRONIC CONTROLLER 1. Overview Interaction with the water heater controller is done through an up, a down, and three operation buttons. These buttons are illustrated to the right. Operation of the three lower buttons is dened immediately above them on the screen. The [UP] and [DN] buttons are used to navigate through the menus an ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 17

    17 3. Adjusting the Operating Set Point The Operating Set Point of this water heater determines the regulated temperature for the water in the tank. This parameter is adjusted in the T emperature menu. Items in this menu allow you to monitor dif ferent tem - perature readings in the tank along with adjusting the Operating Set Point and Differential ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 18

    18 4. Changing the Display Units The display interface to the heater has the option of selecting between de - grees Fahrenheit and degrees Celsius for temperature displays. This can be found in the “Display Settings” menu. Also in this menu, you may adjust how the backlight operates and the contrast of the LCD screen. ACTION: From the Main Menu ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 19

    19 ACTION: T o get to the current fault information screen, press Menu. DISPLA Y : ACTION: Press the DOWN button to highlight "current Fault" and press Select. DISPLA Y : ACTION: Press the DOWN button for more information. DISPLA Y : 7. Viewing the Fault History The controller for this water heater will store a history of ten of the last ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 20

    20 W I T H A R I S K O F F I R E O R E X P L O S I O N . S E E T H E F R O N T PA G E F O R STEPS TO B E T A K EN. D O N O T U S E T H I S H E AT E R I F A N Y P A R T H A S B E E N U N D E R W A TER. IMMEDIA TEL Y CALL A QU ALIFIE D SER VICE TE CHNICIAN TO IN SPECT TH E H E A T ER A N D TO R EPL ACE AN Y PART OF TH E CO NTRO L SY STEM AN D ANY GAS ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 21

    21 W ARNING UNDER NO CIRCUMST ANCES SHOULD THE INPUT EXCEED THE RA TE SH OWN ON THE HEA TER R A TI NG PLA TE . O VER FIRING COU LD RESUL T IN DAMAGE OR SOOTING OF THE HEA TER. CA THODIC PROTECTION CAUTION HYDROGEN GAS CAN BE PRODUCED IN A HOT W A TER SYSTEM SE RV ED BY T H IS HE A TE R TH A T HA S NO T BE EN USE D FO R A L O NG PERIOD OF TIME (GENE ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 22

    22 199 MODELS. OPERA TING INSTRUCTIONS TURN OFF GAS TO APPLIANCE FOR YOUR SAFETY READ BEFORE OPERA TING W ARNING: If you do not follow these instructions exactly , a fire or e xp l o s io n may result causing property damage, personal injury or loss of life. OPERA TING INSTRUCTIONS TURN OFF GAS TO APPLIANCE ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 23

    23 Sed imen t a nd lime sca le removal may be acc omp lish ed thro ugh the c l e a n ou t o p e n i n g f ur n i sh e d o n t h e h e a t e r, s e e Fi g u r e 25 . T h e h e a te r m u s t b e d r a i n e d , s e e D R A I N I N G , b e f o r e r e m o v i n g c l e a n o u t c o v e r on t ank. FIGURE 16. T o dissolve and remove the more stubborn ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 24

    24 DRAIN V AL VE AND ACCESS P ANELS The heaters are equipped with a 3/4" drain valve. An access panel covers the cleanout opening in the tank which is sealed by a gasket and cover , gure 25. RELIEF V AL VE At least twice a year , the temperature and pressure relief valve should be checked to ensure that it is in operating condition. T o che ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 25

    25 ONE TEMPERA TURE - ONE HEA TER HORIZONT AL ST ORAGE T ANK FORCED CIRCULA TION WITH OR WITHOUT BUILDING RECIRCULA TION DANGER TEMPERA TURE SETTING SHOULD NOT EXCEED SAFE TEMPERA TURE A T FIXTURES. SEE W A TER TEMPERA TURE CONTROL W ARNING ON P AGE 4 . I F H I GH E R P R EH E AT T E M P E R ATU R E S AR E NECESSARY TO OBT AIN ADEQUA TE BOOSTER OUT ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 26

    26 * PIPE RELIEF V AL VE T O OPEN DRAIN. NOTE: I F T E M P E R E D W A T E R I S RECIRCULA TED, RETURN LINE SHOULD BE CONNECTED A T POINT “A”. INST ALL IN ACCORDANCE WITH LOCAL CODES. TWO TEMPERA TURE - ONE HEA TER HIGH TEMPERA TURE WITH OR WITHOUT BUILDING RECIRCULA TION DANGER TEMPERA TURE SETTING SHOULD NOT EXCEED SAFE TEMPERA TURE A T FIXTU ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 27

    27 TWO TEMPERA TURE - TWO HEA TERS HIGH TEMPERA TURE WITH OR WITHOUT BUILDING RECIRCULA TION TWO TEMPERA TURE - THREE HEA TERS (TWO PRE-HEA TERS/ONE BOOSTER HEA TER) WITH OR WITHOUT BUILDING RECIRCULA TION MUST BE IDENTICAL HEA TERS FOR MUL TIPLE HEA TER INST ALLA TION SEE MANIFOLD KIT SPECIFICA TIONS, P AGE 30. CAUTION: IF BUILDING CO LD WA TER SU ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 28

    28 * PIPE RELIEF V AL VE T O OPEN DRAIN ** 140°F (60°C) TO 150°F (66°C) SHOULD BE MAXIMUM WA TER TEMPERA TURE MAINT AINED IN THE PRE-HEA TERS. 120°F (49°C) SHOULD BE THE MINIMUM TEMPERATURE OF WATER IN THE PRE- HEATERS. CONNECT CIRCULA TING LINE FROM FIXTURES, IF USED, TO COLD WA TER SUPPL Y LINE OF PRE-HEA TER. C O N N EC T C IR C U L A TI N ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 29

    29 NOTE 1: TOGGLE SWITCH CONTROLS 180°F (82°C) WA TER CIRCULA TION. INST ALL ON OR CLOSE TO DISHWASHER. TOGGLE SWITCH MUST BE CLOSED (ON) DURING THE RINSE OPERA TION AND OPEN (OFF) WHEN DISHWASHER IS NOT OPERA TING OR WHEN ON LONG ST ANDBY . NOTE 2: INST ALL LINE TEMPERA TURE CONTROL IN AN UNINSULA TED TEE BEYOND THE DISHW ASHER T AKEOFF IN THE S ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 30

    30 MANIFOLD KITS Precision cut type “L” all copper State manifold kits assure water ow balance of all units. Without this balance, the full water heating and storage potential of the system cannot be achieved. Plus, the units with the higher water ow may have a shortened life. Dimensions shown are for minimum space occupied by the water h ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 31

    31 CHECKLIST AND SER VICE INFORMA TION IMPORT ANT The installer may be able to observe and correct certain problems which might arise when the unit is put into operation or when it is re-fired after a prolonged shutdown. HOWEVER, it is recommended that only qualified servicemen, using appropriate test equipment, be allowed to service the heater . B ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 32

    32 MOTOR WILL NOT RUN 1. Conrm 120V AC to the controller . Also, to verify correct polarity , check for 120 V AC between hot supply and ground. If there is no voltage, check for a loose connection where it connects to the controller . 2. If there is 120 volts to the controller , check for loose connections or a locked rotor . If the rotor cannot ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 33

    33 NOTES: ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 34

    34 NOTES: ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 35

    35 MODEL RUF LIMITED W ARRANTY The warrantor extends the following LIMITED W ARRANTY to the owner of this water heater . 1. THE T ANK If the glass-lined tank in this water heater shall prove upon examination by the warrantor to have leaked due to natural corrosion from potable water therein, during the rst THREE years after initial installation, ...

  • Reliance Water Heaters RUF 100 199 SERIES 101 - page 36

    36 ...

Fabricante Reliance Water Heaters Categoría Water Heater

Los documentos del dispositivo Reliance Water Heaters RUF 100 199 SERIES 101 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Reliance Water Heaters
- manuales de instrucciones RUF 100 199 SERIES 101
- hojas de producto Reliance Water Heaters
- folletos informativos
- o etiquetas energéticas Reliance Water Heaters RUF 100 199 SERIES 101
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Reliance Water Heaters RUF 100 199 SERIES 101.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Reliance Water Heaters RUF 100 199 SERIES 101, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Reliance Water Heaters RUF 100 199 SERIES 101. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Reliance Water Heaters RUF 100 199 SERIES 101.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Reliance Water Heaters RUF 100 199 SERIES 101, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Reliance Water Heaters RUF 100 199 SERIES 101. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Reliance Water Heaters RUF 100 199 SERIES 101.

El manual de instrucciones completo de Reliance Water Heaters debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Reliance Water Heaters RUF 100 199 SERIES 101 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Reliance Water Heaters RUF 100 199 SERIES 101, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Reliance Water Heaters RUF 100 199 SERIES 101 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Reliance Water Heaters RUF 100 199 SERIES 101 - que deben facilitarnos los primeros pasos durante el uso de Reliance Water Heaters RUF 100 199 SERIES 101
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Reliance Water Heaters RUF 100 199 SERIES 101
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Reliance Water Heaters RUF 100 199 SERIES 101 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Reliance Water Heaters RUF 100 199 SERIES 101?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Reliance Water Heaters RUF 100 199 SERIES 101, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Reliance Water Heaters RUF 100 199 SERIES 101 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)