Manual de instrucciones Net Optics none

57 de páginas 3.19 mb
Descargar

Pasar a la página of 57

Summary
  • Net Optics none - page 1

    User Guide "Smart Filtering" Appliance Doc. PUBDIRU Rev . 2, 9/08 ww w.netoptics.com 1 2 B A A B IDS Analyzer 2 Analyzer 1 RMON 1 RMON 2 Forensic *** Condential - DO NOT Distribute *** ...

  • Net Optics none - page 2

    PLEASE READ THESE LEGAL NOTICES CAREFULL Y . By using a Net Optics Director device you agree to the terms and conditions of usage set forth by Net Optics, Inc. No licenses, express or implied, are granted with respect to any of the technology described in this manual. Net Optics retains all intellectual property rights associated with the technolog ...

  • Net Optics none - page 3

    Director *** Condential - DO NOT Distribute *** Contents Chapter 1 Introduction .............................................................................................. 1 Key Features ............................................................................ 2 About this Guide ............................................................. ...

  • Net Optics none - page 4

    Director *** Condential - DO NOT Distribute *** Create Complex Filters ................................................................... 29 V iew lters ............................................................................ 3 0 W ork with congurable 10 Gigabit ports ..................................................... 3 1 Understan ...

  • Net Optics none - page 5

    1 *** Condential - DO NOT Distribute *** Director Chapter 1 Intr oduction Net Optics Director is a key component for building a comprehensive, consolidated monitoring infrastructure for both network management and security . It extends the range of visibility for data monitoring across converged data and digital voice networks, while eliminating ...

  • Net Optics none - page 6

    2 *** Condential - DO NOT Distribute *** Director K ey Fea tur es Ease of Use T ap, aggregation, regeneration, matrix switch, and lter functions in a single device • 19-inch rack frame, 1U high • Front-mounted connectors for quick and easy installation • LED indicators show Power , Link, and Activity status • Modular design for con ...

  • Net Optics none - page 7

    3 *** Condential - DO NOT Distribute *** Director About this Guide Please read this entire guide before installing Director . This guide applies to the following part numbers: Chassis Part Number Description DIR-3400 Director Main Chassis with 10 SFP monitor ports DIR-____ Director Main Chassis with 10 SFP monitor ports, -48VDC power DIR-7400 Di ...

  • Net Optics none - page 8

    4 *** Condential - DO NOT Distribute *** Director Director Ar chitecture The fo llowing diag ram shows a schematic v iew of the architecture of the Dir ector device shown as a Matri x Switch wit h ltering. The black dots indicate aggregating Matrix Switch connections between Network Ports and Monitor Ports. K e y : Network or Span port Monito ...

  • Net Optics none - page 9

    5 *** Condential - DO NOT Distribute *** Director The input s are divide d int o t hree g roups: two D NMs p lus th e 10Gb E port s. In -li ne DNM model s supp ort 6 in-li ne lin ks, whi le Spa n DNM models supp ort 12 Sp an por ts. The d iag ram sh ows on e in-l ine an d one Span DNM. B oth in -line an d Span DNMs are available with either Copp ...

  • Net Optics none - page 10

    6 *** Condential - DO NOT Distribute *** Director Typical Application The following diagram shows a typical application using Director to implement a comprehensive, consolidated monitoring infrastructure. ww w.netoptics.com 1 2 B A A B IDS Analyzer 2 Analyzer 1 RMON 1 RMON 2 Forensic Director-centric network monitoring infrastructure Figure 2: I ...

  • Net Optics none - page 11

    7 *** Condential - DO NOT Distribute *** Director In this installation, Director has ten additional Span ports and one in-line link that are available for expansion, when more links need to be monitored. Monitoring T ools St ill re fer ri ng to Fig ure 2, si x m on it ori ng too ls a re con nec te d to Dir ect or . Th ey inc lud e pr oto col an ...

  • Net Optics none - page 12

    8 *** Condential - DO NOT Distribute *** Director In-line Monitoring of 10 Gigabit Links T o create an in-line link on a 10 Gigabit network segment, use and external iBypass Switch or network T ap. These two methods are explained in the following sections. iBypass Switch Method One method for creating a fail-safe, passive in-line 10 Gigabit netw ...

  • Net Optics none - page 13

    9 *** Condential - DO NOT Distribute *** Director Director Front Panel The features of the Director front panel are shown in the following diagram. www.netoptics.com ™ Director 1 2 B A 1 6 2 7 3 8 5 10 4 9 A B In-Line 10/100/1000 10 100 1000 LINK ACT In-Line GigaBit 1 2 3 4 5 6 7 8 9 10 11 12 A B A B A B 10 SFP Monitor Ports 2 XFP Configurable ...

  • Net Optics none - page 14

    10 *** Condential - DO NOT Distribute *** Director Director Rear P anel The features of the Director rear panel are shown in the following diagram. Management Port RS232 INPUT OUTPUT SERIAL NUMBER XXXXXX Power Supply Module Managemen t Port RS-232 Port 2 XFP Daisy-chain 10GbE Ports SR, LR, or ER Fiber XFP Modules Redundant Hot-swappable Power Su ...

  • Net Optics none - page 15

    11 *** Condential - DO NOT Distribute *** Director Chapter 2 Installing Dir ector This chapter describes how to install and connect Director devices. The procedure for installing Director follows these basic steps: Plan the installation 1. Unpack and inspect the Director device 2. Install the DNM modules 3. Install the SFP and XFP modules 4. Rac ...

  • Net Optics none - page 16

    12 *** Condential - DO NOT Distribute *** Director Plan the Installation Before you begin the installation of your Director device, determine the following: Name that will identify the Director device • IP address of the Director device, or • a range of IP addresses if you are deploying multiple Director devices Net Mask for Director • IP ...

  • Net Optics none - page 17

    13 *** Condential - DO NOT Distribute *** Director Install Director Networ k Modules If the Director Network Modules (DNMs) are not already installed when you receive the unit, install them by sliding them into the DNM slots in the front panel. (If there is a plate covering the DNM slot, remove it by unscrewing two thumb- screws, and then instal ...

  • Net Optics none - page 18

    14 *** Condential - DO NOT Distribute *** Director Connect P ower to Director For power fault protection, Director is equipped with redundant power connections. If one power source becomes unavailable due to an interruption in AC power or failure of the power brick, the other power source keeps Director operating normally . If both power sources ...

  • Net Optics none - page 19

    15 *** Condential - DO NOT Distribute *** Director Launch terminal emulation software and set communication parameters to: 2. 1 15200 baud 8 data bits No parity 1 stop bit Noowcontrol The Net Optics CLI banner and login prompt are displayed in the T erminal Emulation software. ********************************************************** * ...

  • Net Optics none - page 20

    16 *** Condential - DO NOT Distribute *** Director Enter 4. netoptics as the password. For security , the password is not displayed as you type it. The Director CLI runs and the CLI sign-on banner and login prompt are displayed. login as: customer customer@10.60.4.8's password: Last login: Thu Sep 4 09:40:31 2008 from 10.30.1.62 *********** ...

  • Net Optics none - page 21

    17 *** Condential - DO NOT Distribute *** Director Congure Dir ector using the CLI Y ou should be logged into the Director CLI. The factory-set default values for Director are: Username: • admin Password: • netoptics IP Address: • 10.60.4.180 (address for remote CLI, and for Compass manager software, when available) Netmask: • 255.0.0 ...

  • Net Optics none - page 22

    18 *** Condential - DO NOT Distribute *** Director Assign a New Director IP Ad dress, Netmask, and Gateway IP Address If you are using the local RS-232 serial interface to access the CLI, then you need to congure the IP Address that Compass management software, when available, will use to communicate with Director . If Director must communica ...

  • Net Optics none - page 23

    19 *** Condential - DO NOT Distribute *** Director Tip! ___________________________________________________________________________________________________ Y ou can change the modes of multiple ports in a single command by specifying the ports in the portlist. Use a comma to separate items in the list, and use a dash (-) to indicate a range. For ...

  • Net Optics none - page 24

    20 *** Condential - DO NOT Distribute *** Director Using the CLI Help Command T o view CLI help information: Enter 1. Help at the "Net Optics:" prompt. The list of help topics is displayed. Net Optics> help ![#] - !number or up/down key for previous command commit - save local cong to hardware date - set system date del - delete ...

  • Net Optics none - page 25

    21 *** Condential - DO NOT Distribute *** Director Using the CLI Command Histor y Buffer Y ou can save a lot of typing by using the command history buf fer maintained by the CLI. The up- and down-arrow keys scroll forward and backward through the history buffer . T o execute a command again, simply scroll to that com- mand and press enter . Alte ...

  • Net Optics none - page 26

    22 *** Condential - DO NOT Distribute *** Director Connect Span P or ts to Director T o connect Director to the network using Span ports, be sure that at least one of your DNMs is a Span model. Use ports in that DNM to connect to the network. Span port numbering is shown in the following diagram. It is the same for Span DNMs and in-line DNMs. ww ...

  • Net Optics none - page 27

    23 *** Condential - DO NOT Distribute *** Director Connect Director W ith In-line Networ k Links T o connect Director to the network using an in-line installation, be sure that at least one of your DNMs is an in-line model. T ap port-pairs for each link are located side by side, with three links across the top row and three links across the bott ...

  • Net Optics none - page 28

    24 *** Condential - DO NOT Distribute *** Director ww w.netoptics.com ™ Director 1 2 B A 1 6 2 7 3 8 5 10 4 9 A B In-Line 10/100/1000 10 100 1000 LINK ACT In-Line GigaBit 123456789 10 11 12 A B A B A B In-line Network connections Figure 21: Connect Monitoring T ools to Director T o connect a monitoring tool to Director, simply plug the appropr ...

  • Net Optics none - page 29

    25 *** Condential - DO NOT Distribute *** Director Chapter 3 Conguring Filter s Using the CLI This chapter describes how to use the CLI to determine which monitoring tools are connected to which Network ports. It also explains how to create lters to limit the amount of trafc copied to Monitor ports, so the monitoring tools receive only ...

  • Net Optics none - page 30

    26 *** Condential - DO NOT Distribute *** Director When you dene a lter , you specify and action to be taken when the lter conditions are met. The action can be either drop or r edir (meaning redirect). If the action is drop , then packets which meet the lter criteria are dropped, that is, they are not copied to any Monitor port. If ...

  • Net Optics none - page 31

    27 *** Condential - DO NOT Distribute *** Director Network Port 1 Network Port 2 Monitor Port 3 + lter add in_ports=n1.1,n1.2 action=redir redir_por ts=m.3 T rafc aggregation Figure 23: R e gener ate T r afc to Any Set of Monitor P or ts Director can be used like a Regeneration T ap, copying trafc from a Network port (or aggregated g ...

  • Net Optics none - page 32

    28 *** Condential - DO NOT Distribute *** Director Create Filter s Filters process a trafc stream by selecting packets based on criteria in the packet header . A lter is dened using a lteradd command, which also species the Network ports and Monitor ports the lters apply to. The lteradd com mand species the fo ...

  • Net Optics none - page 33

    29 *** Condential - DO NOT Distribute *** Director ip_dst IP destination address • ip_dst_mask IP source address mask • ip_proto IP protocol • l4_src_port Layer 4 source port • l4_dst_port Layer 4 destination port • vlan VLAN number • Create Comple x Filter s Multiple lter parameters can be specied in a single lteradd ...

  • Net Optics none - page 34

    30 *** Condential - DO NOT Distribute *** Director Monitor Port 1 Network Port 5 lter add in_ports=n1.5 ip_proto=6 action=redir redir_ports=m.1 lter add in_ports=n1.5 ip_proto=17 action=redir redir_ports=m.1 Protoc ol = TC P Protoc ol = UDP + Logical OR lter connection Figure 29: View lter s T o view a list of all pending lters, e ...

  • Net Optics none - page 35

    31 *** Condential - DO NOT Distribute *** Director W or k with congur able 10 Giga bit por ts The two congurable 10 Gigabit XFP ports on the front panel are designated t.1 (on the left) and t.2 (on the right). They can be used in network port lists and monitor port lists. The 10 Gigabit ports are congured for Network or Monitor as requi ...

  • Net Optics none - page 36

    32 *** Condential - DO NOT Distribute *** Director lter add in_ports=n1.11 action=redir redir_por ts=t.2 lter add in_ports=n1.1-n1.4 action=redir redir_por ts=t.1 XFP Port 2 XFP Port 1 Network Port 11 Network Port 1 Network Port 4 Network Port 2 Network Port 3 + Congurable 10 Gigabit XFP ports used as Monitor ports (with aggregation) Fi ...

  • Net Optics none - page 37

    33 *** Condential - DO NOT Distribute *** Director Under stand lter interactions It is important to understand that Director uses Content Addressable Memory (CAM) technology to implement lters. As each lter is dened, it is stored in the next available entry in the CAM. Each packet header is compared in the CAM, and the CAM returns th ...

  • Net Optics none - page 38

    34 *** Condential - DO NOT Distribute *** Director Have we achieved our goal of sending all the TCP trafc to Monitor Port 2? Not quite. What happens when an TCP packet arrives from 192.186.10.0? It matches the lter at CAM address 1, so it is copied to Monitor Port 1. But that is all that happens; it does not go to Monitor Port 2. The ow ...

  • Net Optics none - page 39

    35 *** Condential - DO NOT Distribute *** Director Note: __________________________________________________________________________________________________ Instead of lteradd , you can use a lter ins command to dene lters. The only difference is that lter ins allows you to specify the lter's ID, which is its posit ...

  • Net Optics none - page 40

    36 *** Condential - DO NOT Distribute *** Director Under stand pending and activ e lter s T o understand the actions of lter commands such as ltercommit,lterdiscard, and lter delete, it is helpful to visualize the pending lter list and the CAM that holds the active lters. The previous section explained how ...

  • Net Optics none - page 41

    37 *** Condential - DO NOT Distribute *** Director Pending lter list Address Filter 1 n1.1 ip_proto=UDP action=drop 2 n1.1 m.1 CAM Address Filter 1 n1.1 ip_proto=UDP action=drop 2 n1.1 m.1 After lter sync Figure 41: Use 3. lter add,lterins, and lter del commands to change lters as desired. Pending lter list Ad ...

  • Net Optics none - page 42

    38 *** Condential - DO NOT Distribute *** Director Be aware of these similar pairs of commands: lterdiscard • clears the pending lter list, while lterclear clears the CAM lterlist • shows the pending lter list, while lterrunning shows the CAM ltercommit • copies the pending lter list to th ...

  • Net Optics none - page 43

    39 *** Condential - DO NOT Distribute *** Director Chapter 4 Daisy-c haining Multiple Dir ector Chassis This chapter describes how to expand the capacity of Director by daisy-chaining multiple Director chassis. The complete set of chassis becomes a single logical system with up to 380 total ports. By using long-reach ER links, chassis can be phy ...

  • Net Optics none - page 44

    40 *** Condential - DO NOT Distribute *** Director A ppendix A Dir ector Specica tions Specications, c hassis Mechanical Dimensions: 1.6” high x 15.65” deep x 17” wide Mounting: Surface or 19” rack mount (1U) W eight: TBA Connectors Network Port Slots: (2) Director Network Module (DNM) Monitor Ports: (10) SFP Congurable 10Gigabi ...

  • Net Optics none - page 45

    41 *** Condential - DO NOT Distribute *** Director Specications, DNM Copper Interface (12) RJ45 Network Ports 10/100/1000Mbps (6) In-line links or (12) Span ports depending on model 22-24 A WG unshielded twisted pair cable, CA T5e or better recommended Fiber Optic Interface (12) Gigabit SX, LX, or ZX Network Ports, LC type (6) In-line links o ...

  • Net Optics none - page 46

    42 *** Condential - DO NOT Distribute *** Director A ppendix B Command Line Interface Tip! ___________________________________________________________________________________________________ The command line interface (CLI) is not case sensitive. ____________________________________________________________________________________________________ ...

  • Net Optics none - page 47

    43 *** Condential - DO NOT Distribute *** Director Command Sub-Command Parameters Example and description lter add ipv6=< y | n > in_ports=<network_portlist>* <qual>=<value> action=< redir | drop > redir_ports=<monitor_portlist> Notes: T h e command may include any number of <qual>, up to the limit of ...

  • Net Optics none - page 48

    44 *** Condential - DO NOT Distribute *** Director Command Sub-Command Parameters Example and description lter (continued) list ipv6=< y | n > lter list Parameters: ipv6=y for IPv6 addressing; ipv6=n for IPv4 ad- dressing (defaults to IPv4 if parameter is omitted) Displays all pending lters (with lter IDs) running ipv6=< y | ...

  • Net Optics none - page 49

    45 *** Condential - DO NOT Distribute *** Director Command Sub-Command Parameters Example and description passwd passwd Interactively changes the password of the SSH user account ping <address>* ping 10.1.1.4 Parameters: <address> is an IP address Pings the specied IP address to check for connectivity port set ports=<portlist&g ...

  • Net Optics none - page 50

    46 *** Condential - DO NOT Distribute *** Director Command Sub-Command Parameters Example and description sysip commit sysip commit Activates pending changes dened with sysip set set ipaddr=<address> netmask=<netmask> gw=<gateway> sysip ipaddr=192.168.1.2 netmask=255.255.0.0> Parameters: <address> is the IP address ...

  • Net Optics none - page 51

    47 *** Condential - DO NOT Distribute *** Director Command Sub-Command Parameters Example and description user This command is only available at root level show user show Lists all the currently dened user accoounts This command is only available at root level add name=<username>* pw=<password> priv=<level> Notes: All three ...

  • Net Optics none - page 52

    48 *** Condential - DO NOT Distribute *** Director Filter parameter s Switches and lters are dened using the lteradd and lter ins commands. The lteradd command syntax is: lter add in_ports=< portlist > <lter_parameter_list> action=<redir|drop> redir_ports=< portlist > The <lter ...

  • Net Optics none - page 53

    49 *** Condential - DO NOT Distribute *** Director A ppendix C Pr otocol Number s The ofcial Assigned Internet Protocol Numbers list is maintained by the Internet Assigned Numbers Authority and can be found at http://www .iana.org/assignments/protocol-number s. The list as of April 18, 2008 is reproduced in the following table (without refere ...

  • Net Optics none - page 54

    50 *** Condential - DO NOT Distribute *** Director Num Keyword Protocol 55 MOBILE IP Mobility 56 TLSP Transport Layer Security Protocol using Kryptonet key management 57 SKIP SKIP 58 IPv6- ICMP ICMP for IPv6 59 IPv6- NoNxt No Next Header for IPv6 60 IPv6-Opts Destination Options for IPv6 61 any host internal protocol 62 CFTP CFTP 63 any local ne ...

  • Net Optics none - page 55

    51 *** Condential - DO NOT Distribute *** Director Num Keyword Protocol 1 15 L2TP Layer T wo T unneling Protocol 1 16 DDX D-II Data Exchange (DDX) 1 17 IA TP Interactive Agent T ransfer Protocol 1 18 STP Schedule Transfer Protocol 1 19 SRP SpectraLink Radio Protocol 120 UTI UTI 121 SMP Simple Message Protocol 122 SM SM 123 PTP Performance T rans ...

  • Net Optics none - page 56

    52 *** Condential - DO NOT Distribute *** Director Limitations on W ar ranty and Liability Net Optics of fers a limited warranty for all its products. IN NO EVENT SHALL NET OPTICS, INC. BE LIABLE FOR ANY DAMAGES INCURRED BY THE USE OF THE PRODUCTS (INCLUDING BOTH HARDW ARE AND SOFTW ARE) DE - SCRIBED IN THIS MANUAL, OR BY ANY DEFECT OR INACCURAC ...

  • Net Optics none - page 57

    © 2008 by Net Optics, Inc. All Rights Reserved. www .netoptics.com ...

Fabricante Net Optics Categoría Network Router

Los documentos del dispositivo Net Optics none que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Net Optics
- manuales de instrucciones none
- hojas de producto Net Optics
- folletos informativos
- o etiquetas energéticas Net Optics none
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Net Optics none.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Net Optics none, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Net Optics none. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Net Optics none.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Net Optics none, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Net Optics none. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Net Optics none.

El manual de instrucciones completo de Net Optics debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Net Optics none - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Net Optics none, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Net Optics none que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Net Optics none - que deben facilitarnos los primeros pasos durante el uso de Net Optics none
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Net Optics none
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Net Optics none en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Net Optics none?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Net Optics none, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Net Optics none probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen