    Cope l and Scroll ® C ompre ss or Module Installation, O pera tion & Mainten ance Manual Model F amily SZ O22 SZV22 ...

  • Emerson SZO22 - page 2

    ...

  • Emerson SZO22 - page 3

    Single-Compressor Module T ABLE OF CONTENTS i 2008SSD-34 (5/1 1) T ABLE OF CONTENTS C ompressor m odule N omeNCla ture ............................................................................................. iv i mport aNt s afety i Nforma tioN .................................................................................................... ...

  • Emerson SZO22 - page 4

    Single-Compressor Module T ABLE OF CONTENTS ii 2008SSD-34 (5/1 1) 4.2 Maintenance T ools ...................................................................................................................... 18 4.3 Oil Service ........................................................................................................................... ...

  • Emerson SZO22 - page 5

    Single-Compressor Module T ABLE OF CONTENTS ii 2008SSD-34 (5/1 1) Single-Compressor Module T ABLE OF CONTENTS iii 2008SSD-34 (5/1 1) FIGURES Figure 1 Compressor Module Components ........................................................................................................ 3 Figure 2 Copeland Scroll ® Compressor Cross Section ........... ...

  • Emerson SZO22 - page 6

    Single-Compressor Module Compressor Module Nomenclature iv 2008SSD-34 (5/1 1) C ompressor m odule N omeNCla ture Model Max Delivery Pressure (PSIG) Max Flow (MCFD) Drive HP High Press Switc h Setting (PSIG) Low Press Switc h Setting High Te m p Setting °F (°C) Oil Thermal Bypass V alve Setpoint °F (°C) Gas Bypass Va l ve Module W eight (Lbs.) S ...

  • Emerson SZO22 - page 7

    Single-Compressor Module Important Safety Information 1 2008SSD-34 (5/1 1) Single-Compressor Module Compressor Module Nomenclature iv 2008SSD-34 (5/1 1) i mport aNt s afety i Nforma tioN This manual contains important instructions for installation, operation and maintenance of your Copeland Scroll ® Compressor Module. W ARNING The Compressor Modul ...

  • Emerson SZO22 - page 8

    Single-Compressor Module Important Safety Information s afety s ymbols u sed iN t his m aNual SAFETY ALERT SYMBOL When you see this symbol on the Compressor Module or in this manual, look for one of the following words and be aware of the potential for personal injury or property damage. W ARNING A W arning describes hazards that CAN or WILL cause ...

  • Emerson SZO22 - page 9

    3 2008SSD-34 (5/1 1) Single-Compressor Module Introduction 1.0 i NtroduCtioN The Copeland Scroll ® SZO22 Compressor Module comes equipped with one Copeland Scroll ® Compressor designed for Class I, Division II applications. The Compressor Module is designed for assembly into a Compressor Package ready for service in the eld; the completed hous ...

  • Emerson SZO22 - page 10

    Single-Compressor Module Introduction 1.2 The Compressor The Compressor refers to the Copeland Scroll ® Compressor . Figure 2 shows a cross-section of a Compressor and its key components. Figure 2 Copeland Scroll ® Compressor Cross Section (not shown: Encapsulated Stator) 1.3 The Compressor Package The Compressor Package consists of the Compresso ...

  • Emerson SZO22 - page 11

    5 2008SSD-34 (5/1 1) Single-Compressor Module Installation 2.0 i Nst alla tioN 2.1 Installation Guidelines 2.1.1 Required Component—Inlet Gas Scrubber An appropriate inlet gas scrubber is REQUIRED to remove liquids from the gas prior to compression. If there is potential for liquid slugging, a suitable trap must be installed to prevent liquid fro ...

  • Emerson SZO22 - page 12

    6 2008SSD-34 (5/1 1) Single-Compressor Module Installation NOTE: Required Component – High Pressure Discharge Gas Bypass V alve T o eliminate redundancy , the high pressure discharge gas bypass (recycle) valve was removed from some of the scroll modules. Packagers will need to install pressure relief downstream of our module. See table on page iv ...

  • Emerson SZO22 - page 13

    7 2008SSD-34 (5/1 1) 6 2008SSD-34 (5/1 1) Single-Compressor Module Installation 2.4 Installation Clearance and Dimensions Allow sufcient clearance on all sides for service access, especially for gas and electrical connections at the rear of the Compressor Module. Check applicable national and local electrical codes. Cooling air ow is back to ...

  • Emerson SZO22 - page 14

    8 2008SSD-34 (5/1 1) Single-Compressor Module Installation 2.5 Process and Instrumentation Diagrams (P&IDs) Figure 5 Compressor Module Gas and Oil Flow Diagram and Safety Shutdowns Single Compressor Module Gas & Oil Flow Diagram & Safety Shutdowns (Gas bypass valve shown is optional) ...

  • Emerson SZO22 - page 15

    9 2008SSD-34 (5/1 1) 8 2008SSD-34 (5/1 1) Single-Compressor Module Installation 2.6 Electrical Controls 2.6.1 General Considerations All shutdown devices are dry contact switches rated Class I, Division II that are wired to a terminal box for connection to the packager supplied control circuit. The common wires on all switches are connected togethe ...

  • Emerson SZO22 - page 16

    10 2008SSD-34 (5/1 1) Single-Compressor Module Installation R ED Bl ue Wh it e Y e ll ow +24VD C DC c o m m on N o co n n ecti o n feed b ack 0-10VD C sp eed si g n al 2.6.2 Oil Cooler Fan Control The Compressor Module temperature is controlled by managing module oil ow and temperature. The module’s precise temperature control is critical to s ...

  • Emerson SZO22 - page 17

    11 2008SSD-34 (5/1 1) 10 2008SSD-34 (5/1 1) Single-Compressor Module Installation Figure 8 Optional Customer-Installed High T emperature Fan Control System • Compressor requirements: 0.8 to 2 GPM (3.0-755 LPM) ow rate • Thermal oil bypass valve, standard setting: 200°F (93°C) / 250°F model specic • Thermal bypass valve operation (val ...

  • Emerson SZO22 - page 18

    12 2008SSD-34 (5/1 1) Single-Compressor Module Installation 2.6.3 Compressor Module Motor Protection V ariable Speed Compressor Module Protection • The VFD provides overload protection for the compressor . • Module capacity can be changed by varying the typical Compressor speed, ranging from 2400 to 4800 rpm. Figure 10 Motor Control ...

  • Emerson SZO22 - page 19

    13 2008SSD-34 (5/1 1) 12 2008SSD-34 (5/1 1) Single-Compressor Module Installation 2.6.4 Electrical Requirements Figure 1 1 T ypical Compressor Module Electrical Requirements 1 2 3 4 Op ti on al if mo re th an on e co mp re ss or mo du le us ed Po we r to Co mp resso rs 24 VD C C ooling Fa n 24 V Di screte Input s fr om S cr oll Mod ule 1 1 T able 2 ...

  • Emerson SZO22 - page 20

    14 2008SSD-34 (5/1 1) Single-Compressor Module Installation 2.6.5 Wiring Figure 12 Control Circuit T erminations Control Wiring T erminations ...

  • Emerson SZO22 - page 21

    15 2008SSD-34 (5/1 1) 14 2008SSD-34 (5/1 1) Single-Compressor Module Installation 2.6.6 V ariable Frequency Drive (VFD) T erminations Refer to Product Bulletin on V ariable Frequency Drive Applications for details on VFD terminations and typical VFD parameters. 3.0 o pera tioN 3.1 Initial Startup - Compressor Module The following inspections should ...

  • Emerson SZO22 - page 22

    16 2008SSD-34 (5/1 1) Single-Compressor Module Operation 3.1.2 Post-Startup Checklist Perform these checks AFTER starting the Compressor Module: DURING INITIAL OPERA TION, PERFORM THESE CHECKS: ___ 1. Compressor Module builds pressure on initial startup; no unusual mechanical noise. ___ 2. Oil level is correct at minimum and maximum speeds. ___ 3. ...

  • Emerson SZO22 - page 23

    17 2008SSD-34 (5/1 1) 16 2008SSD-34 (5/1 1) Single-Compressor Module Operation 4.0 m aiNteNaNCe 4.1 Routine Maintenance Perform the maintenance procedures in T able 5 at least once per year or more often if needed. Oil consumption varies by application and during initial operation. Monitor the oil level routinely to determine a consistent pattern o ...

  • Emerson SZO22 - page 24

    18 2008SSD-34 (5/1 1) Single-Compressor Module Maintenance 4.2 Maintenance T ools Figure 15 shows the tools needed for maintenance of the Compressor Module. Contact the Packager to obtain a maintenance tool kit. These are typical air conditioning and refrigeration service tools. Figure 13 Maintenance T ools CAUTION When pressure is applied to the o ...

  • Emerson SZO22 - page 25

    19 2008SSD-34 (5/1 1) 18 2008SSD-34 (5/1 1) Single-Compressor Module Maintenance 4.3 Oil Service The oil level indicated on the rst-stage oil separator site glasses varies with inlet and discharge pressures and operating speed. • New oil is clear , it may be necessary to use a ashlight to verify the correct oil level. • The oil level shou ...

  • Emerson SZO22 - page 26

    20 2008SSD-34 (5/1 1) Single-Compressor Module Maintenance • Scavenge line orice or screen is restricted. Clean or replace. • Insufcient back pressure. Conrm 50-60 psig or higher backpressure when the compressor is running. • No specic cause found. Replace oil separator block assembly , scavenge line and secondary oil separator el ...

  • Emerson SZO22 - page 27

    21 2008SSD-34 (5/1 1) 20 2008SSD-34 (5/1 1) Single-Compressor Module Maintenance 4.4 Cleaning the Inlet Screen The 30-mesh screen in the inlet block must remain unobstructed for optimal ow rate. If the ow rate is lower than expected even when the Compressor is running properly , this screen may be obstructed. Figure 14 Gas Inlet Block and Scr ...

  • Emerson SZO22 - page 28

    22 2008SSD-34 (5/1 1) Single-Compressor Module Maintenance 4.6 Changing the Second-Stage Separator Element T o replace the second-stage separator element: 1. T urn of f and isolate the Compressor from all power sources. 2. T urn of f the gas supply . 3. V ent the system to 0 psig. Follow applicable safety procedures and codes. 4. Loosen the separat ...

  • Emerson SZO22 - page 29

    23 2008SSD-34 (5/1 1) 22 2008SSD-34 (5/1 1) Single-Compressor Module Maintenance 5.2 Platform Symptoms Diagnosis Use the following guidelines to troubleshoot operating problems. T able 6 Platform troubleshooting guidelines Problem Recommended Actions Low Gas Flow • Low inlet pressure • Insufcient gas supply • High temperature • Bypass va ...

  • Emerson SZO22 - page 30

    24 2008SSD-34 (5/1 1) Single-Compressor Module Maintenance 6.0 s peCifiCa tioNs T able 7 Compressor Module Specications General Information Inlet pressure range Model specic - refer to application envelope Outlet pressure range 70 to 275 psig (depends on model—see page iv ) Mechanical Description Module weight Approximately 350 lb. (160kg) ...

  • Emerson SZO22 - page 31

    Single-Compressor Module Material Data Safety Sheet 25 2008SSD-34 (5/1 1) 24 2008SSD-34 (5/1 1) a ppeNdix a - m a terial d a t a s afety s heet The information in this material safety data sheet should be provided to all who use, handle, store, transport or are otherwise exposed to this product. CPI believes the information in this document to be r ...

  • Emerson SZO22 - page 32

    Single-Compressor Module Material Data Safety Sheet 26 2008SSD-34 (5/1 1) a.6 f ire aNd e xplosioN h azards Flash Point (by Cleveland Open Cup) 320-530°F (160-276°C) Flammable Limits Not established Auto-Ignition T emperature No data HMIS Ratings Health 0 Flammability 1 Reactivity 0 NFP A Ratings Not established Extinguishing Media Dry chemical; ...

  • Emerson SZO22 - page 33

    Single-Compressor Module Material Data Safety Sheet 26 2008SSD-34 (5/1 1) ...

  • Emerson SZO22 - page 34

    EmersonClim ate .com Vilter M anufacturing LLC P .O. Bo x 8904 Cud ahy , WI 53110-8904 P 414 744 0111 F 414744 1769 www .vilte r .com Copeland Scroll and Eme rson are trademarks of Eme rson Electric Co. or one of its affiliated c ompanies. ©2011 Emerson Climate T echnoligies, Inc. All rights rese rved. Printed in the USA. 2008SSD-34-R2 ...

Fabricante Emerson Categoría Air Compressor

Los documentos del dispositivo Emerson SZO22 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Emerson
- manuales de instrucciones SZO22
- hojas de producto Emerson
- folletos informativos
- o etiquetas energéticas Emerson SZO22
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Emerson SZO22.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Emerson SZO22, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Emerson SZO22. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Emerson SZO22.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Emerson SZO22, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Emerson SZO22. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Emerson SZO22.

El manual de instrucciones completo de Emerson debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Emerson SZO22 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Emerson SZO22, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Emerson SZO22 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Emerson SZO22 - que deben facilitarnos los primeros pasos durante el uso de Emerson SZO22
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Emerson SZO22
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Emerson SZO22 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Emerson SZO22?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Emerson SZO22, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Emerson SZO22 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)