Installation, Operating, and Maintenance Instructions For Use With Positive Pressure Chillers SAFETY CONSIDERA TIONS Positive pressure storage systems are designed to pro- vide safe and reliable service when operated within de- sign specifications. When operating this equipment, use good judgment and safety precautions to avoid damage to equipment ...
-
Carrier 19XB - page 2
CONTENTS Page SAFETY CONSIDERA TIONS ...................1 INTRODUCTION ..............................2 INST ALLA TION ............................. 2-10 Complete Pre-Installation Checks .............2 • IDENTIFY UNIT • INSPECT SHIPMENT Mount the Pumpout Unit .....................3 • MOUNTING ON THE CHILLER • FLOOR MOUNTING Rig the Storage T ...
-
Carrier 19XB - page 3
T able 1 — Positive Pressure System Assembly Numbers POSITIVE PRESSURE SYSTEM ASSEMBL Y NUMBER PUMPOUT UNIT ASSEMBL Y NO. REFRIGERANT COMPRESSOR MOTOR (V -Ph-Hz) MAXIMUM RLA LRA STORAGE T ANK 19XB04280205 19EA42-748 R-22 208-3-60 13.2 63.5 28 cu ft 19XB04280206 19EA44-748 R-22 230-3-60 1 1.5 57.5 28 cu ft 19XB04280207 19EA46-748 R-22 400/460-3-50 ...
-
Carrier 19XB - page 4
CONDENSER W A TER CONNECTIONS (FIELD PIPING) REFRIGERANT INLET V AL VE VENT V AL VE CONTROL BOX (WIRING BY CONTRACTOR) COMPRESSOR VA LV E S VA LV E S 19EA PUMPOUT UNIT 19EA CONTROL BOX (INTERIOR) 19EA PUMPOUT UNITS Fig. 1 — 19XB Positive Pressure Storage System 4 ...
-
Carrier 19XB - page 5
* 3 ⁄ 8 -16 bolts × 1-in. lg; 4 required. Fig. 2 — 19EA Pumpout Unit: T ypical Chiller Mount Fig. 3 — Pumpout Unit Contact Surfaces and Dimensions ELECTRICAL CONNECTION OPTION LIST TRADE SIZE QTY LOCA TION 1 ⁄ 2 ( 1T O P 3 ⁄ 4 ( 1 BOTTOM 1 ( 1 MIDDLE 1 1 ⁄ 4 ( 1 MIDDLE 5 ...
-
Carrier 19XB - page 6
T able 2 — Physical Data 19EA Pumpout Unit ENGLISH (SI) Pumpout Unit Weight* lb (kg) 210 (95) Pumpout Condenser W ater Flow Rate gpm (L/s) 5 to 7 (.32 to .44) Pumpout Condenser W ater Pressure Drop psig (kPa) 6 to 10.7 (41.4 to 73.8) Maximum Entering Condenser W ater T emperature F (C) 85 (29) Maximum Leaving Condenser W ater T emperature F (C) 1 ...
-
Carrier 19XB - page 7
T able 3 — 19XB Storage T ank Rated Dry Weight and Refrigerant Capacity English SIZE CODE T ANK OD (in.) DR Y WEIGHT* (lb) MAXIMUM REFRIGERANT CAP ACITY (lb) ASHRAE/ANSI 15 UL 1963 R-22 R-134a R-22 R-134a 0428 24.00 2380 1842 1860 1704 1716 0452 27.25 3460 3527 3563 3264 3286 SI SIZE CODE T ANK OD (mm) DR Y WEIGHT* (kg) MAXIMUM REFRIGERANT CAP AC ...
-
Carrier 19XB - page 8
DIMENSIONS ENGLISH (ft-in.) T ANK SIZE A B CDE F G H J K LM NP R S T 0428 10- 5 9-10 4-9 2-4 3 ⁄ 4 1-2 3 ⁄ 8 3-1 3 ⁄ 16 4-1 1 3-8 1 ⁄ 8 3- 8 2-9 7 ⁄ 16 3-2 0-3 1 ⁄ 2 4-8 3 ⁄ 4 1-7 7 ⁄ 8 1-7 5 ⁄ 16 3-7 3 ⁄ 4 5-0 1 ⁄ 4 0452 14-1 1 1 ⁄ 4 14- 4 1 ⁄ 2 5-0 7 ⁄ 8 2-8 1 ⁄ 2 1-4 1 ⁄ 4 3-4 7 ⁄ 16 7- 2 1 ⁄ 4 4-0 3-1 1 7 ⁄ ...
-
Carrier 19XB - page 9
GENERAL PIPING CONNECTION SIZES CONNECTION SIZE (in.) Refrigerant T ransfer Connections 1 ⁄ 2 ODS (female) Condenser W ater Cooling Connectors 1 ⁄ 2 NPT (female) Safety Relief Head Pumpdown Condenser 3 ⁄ 8 Flare (male) ODS — Outside Diameter , Sweat LEGEND Factory-Supplied T ubing Field-Supplied T ubing Field-Supplied T ubing (Multiple Chil ...
-
Carrier 19XB - page 10
T able 4 — Relief Devices STORAGE T ANK SIZE RELIEF V AL VE OUTLET SIZE QUANTITY REQUIRED F ACTOR lb air min Kg air min 28 1 in. NPT Female Connector 2 31.4 14.2 52 1 in. NPT Female Connector 2 52.3 23.7 LEGEND Ground Field Wiring Factory Wiring Contactor T erm. Overload T erm. Pumpdown T erm. Pumpdown Comp’r . T erm. Fig. 7 — 19XB Pumpout Sy ...
-
Carrier 19XB - page 11
CONTROLS AND COMPONENTS Figure 1 shows the major components of the PPS system. Pumpout Unit — The pumpout unit consists of a spring- mounted direct motor-driven reciprocating compressor , a water- cooled refrigerant condenser , an oil separator , suction and discharge valves to control refrigerant flow , and prewired safety and control devices. ...
-
Carrier 19XB - page 12
NOTE: During this operation, maintain water circulation through the chiller cooler and condenser vessels to prevent tube freeze-up. DISTILLING THE REFRIGERANT — Refrigerant vapor is transferred from the chiller cooler vessel or pumpout stor- age tank through the pumpout condenser , condensed to a liq- uid, and pumped to the chiller condenser vess ...
-
Carrier 19XB - page 13
e. Open valve 5 fully after the chiller pressure rises above the freezing point of the refrigerant. Let the storage tank and chiller pressure equalize. Open refrigerant charg- ing valve 7 and storage tank charging valve 10 to let liquid refrigerant drain into the chiller . V A L V E 1 a 1 b2345 6 781 0 1 1 CONDITION C C C 2. T ransfer remaining ref ...
-
Carrier 19XB - page 14
3. Remove any remaining refrigerant. a. T urn on chiller water pumps. b. T urn on pumpout condenser water . c. Place valves in the following positions: V A L V E 1 a 1 b23 4567 81 0 1 1 CONDITION C C C C C d. Run the pumpout compressor until the chiller pres- sure reaches 60 psig (414 kPa), [30 psig (207 kPa)]; then, shut of f the pumpout compresso ...
-
Carrier 19XB - page 15
d. Close valve 1a. e. T urn of f pumpout compressor . f. Close valves 1b, 3, and 4. V A L V E 1 a 1 b 23458 1 1 CONDITION C C CCCCC C g. T urn of f pumpout condenser water . h. T urn of f chiller water pumps and lock out chiller compressor . T ransfer All Refrigerant to Chiller Cooler V essel: 1. Push refrigerant into the chiller cooler vessel. a. ...
-
Carrier 19XB - page 16
PUMPOUT COMPRESSOR OIL CHARGE — Use oil con- forming to Carrier specifications for reciprocating compres- sor use. Oil requirements are listed in T able 6. T able 6 — Pumpout Compressor Oil Requirements REFRIGERANT ISO VISCOSITY CARRIER SPECIFICA TION NO. CARRIER P ART NO. R-22 86 PP49-7 PP23BZ101 R-134a 68 PP47-31 PP23BZ103 The total oil char ...
¿Tienes una pregunta acerca de Carrier 19XB?
Utiliza el formulario que se encuentra abajo
Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Carrier 19XB, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Carrier 19XB probablemente compartirá una forma de solucionarlo.