    381333–067 K 50 Hanove r Road, F lorham Park, New J ersey 07932–1591 USA For sales or service call 1 800 800–2726 (A SCO ) www.ascopower .com AS CO PO WER TECH NO LOGI E S CA NA DA PO Box 1238, 17 Airport R oad, Brantf ord, O ntario, Can ada N 3T 5T3 Operator’s Manual Seri es 300 Automatic T ransfer S witc hes E–d esi g n, 260 an d 400 A ...

  • Emerson 400A - page 2

    ...

  • Emerson 400A - page 3

    Nameplate and Catalog Number Identificati on The T rans fer Swi tch name plate i nclude s data for e ach speci fic ASCO Series 300 A TS. Use the A TS only with in the limits show n on this namep late. A typical Catalo g Num ber is shown b elow with it s elements expla ine d. The exampl e is for a Ser ie s 300 A TS with switched neutr al , 3 pol e, ...

  • Emerson 400A - page 4

    ...

  • Emerson 400A - page 5

    SECT ION 1 INST ALLA TION 1 --- 1 Series 300 A utom atic T ransfer Switc hes are factory w ired and tested. Install ation requires skid removal then sec ur- ing the enclosure to the supporting foundati on. Suppo rtin g Fo undat ion The su ppor ting fo undation fo r the enc los ure m ust b e level and straig ht. R efer to the applic able en clos ure ...

  • Emerson 400A - page 6

    INST ALLA TION (cont inued) 1 --- 2 Engine Starting Contacts The engine control c onta ct connec ti ons are located on the t ransfe r switch. Connect si gnal wires t o appropri at e term– inals as speci fied i n T a ble A, shown in Figure 1–2. T able A. Engine start connectio ns. When norma l so urce fails T erminal s on tra nsfer switch contac ...

  • Emerson 400A - page 7

    INST ALLA TION (cont inued) 1 --- 3 F unctio nal T est The F unctional T est consists of thr ee chec ks: manual operation, v oltage check s, and el ectrical operation. NOT ICE Do these checks in the order presented to avoid damaging the auto matic transfer s witch. R ead all instructions on the W iring Diagram and labels affixed to the autom atic t ...

  • Emerson 400A - page 8

    INST ALLA TION (cont inued) 1 --- 4 observe these l ights Figure 1–5. Standard control s and indicato rs. 2–V o l t a g e C h e c k s First check nameplate on tra nsfer swi tch; rated voltage m u s tb et h es a m ea sn o r m a la n de m e r g e n c yl i n ev o l t a g e s . Use ext reme caution when using a meter to measure volta ges in the fo ...

  • Emerson 400A - page 9

    INST ALLA TION (cont inued) 1 --- 5 p r e s st h i sb u t t o n observe these l ights Figure 1–6. Standard control s and indicato rs. 3 – Electrica l Opera tion Th i s pr oce du re wi ll che ck t he e le ctr ica l o pe ra ti o n o f t he A utomatic T ransfer Switc h. Close th e transfe r switc h encl osure door a nd tighten t he screws befo re ...

  • Emerson 400A - page 10

    Hol d 15 sec .t o start t he engine generator and to transf er the load to emergency . Press to cancel the active exercise period (sto ps engine now or afte r cooldow n) Se e page 5– 1. Hol d 5 sec .t os e t 20 min. engine ex ercise perio d immediately (engine starts) and weekly thereaf ter . ³ blinks sl owly when button is r eleased (set) and d ...

  • Emerson 400A - page 11

    SECT ION 3 TEST ING & SERVIC E 3 --- 1 PREV ENTIV E MAIN TENAN CE F or high rel iabil ity and long l ife for the A TS: Ope rate t he sw itc h at l east o nce a mo nth .P e r f o r m t h i s 4–step Electrical Operat ion T e st (te st with load t ransfer). T r ansfer Swi tch T est 1. Press and ho ld the door -mounted T ra nsfer T est button unt ...

  • Emerson 400A - page 12

    TEST ING & SERVIC E (continued) 3 --- 2 MANUAL L OAD TR ANSFER This pr oced ure w ill m anual ly tr ansfer th e load if th e cont ro lle r is d i sco nne ct ed . Do no t manually operate the transfer switch until bot h power so urces are disconnected: open bot h circuit breakers . 1. Open normal and emergency source ci rcuit brea kers. 2. Use t ...

  • Emerson 400A - page 13

    SECT ION 4 ADJUST MENTS 4 --- 1 Ti me De l ay A d j u st m e n t Standard ti me delays are set to customer specificati ons (if none specif ied, st andard factory set tings are used). T o change a setting, follow proc edure on page 4-2. Use T abl e 4-1 as a gu ide to time del ay values and their c or- responding adjustment DIP switch or potentiomete ...

  • Emerson 400A - page 14

    ADJUST MENTS (continued) 4 --- 2 NOT ICE Do not make any set ting changes while the contro ller is energized. How to Change a Setti ng 1. Prev ent the transfer switch from operating b y discon- nec ting one s ourc e first, then the o ther, as fol low s: a. If the transfer s witch is in the No rmal p osition, ope n t he e mer gen cy so urce ci r cui ...

  • Emerson 400A - page 15

    SECTION 5 CONTROL FEA TURES – ENGINE EXER CISERS 5 --- 1 These timer s periodic ally exer cise the em ergenc y engine-g enerator p lant. They can b e set to exercise w ith or withou t load tr ansfer, or they can b e compl etely disab led. The engine-gen erator shoul d be exercised u nder load on ce a week for a minimum time period of 20 minutes, ...

  • Emerson 400A - page 16

    CONTRO L F EATURES (continued) 5 --- 2 Opt ion al Ac ce ssory 11BG – SOURCE AV AILABIL ITY SIG NAL & P ROGRAMMA BLE EN GINE EX ERCIS ER MOD ULE 2–line display 3 buttons connectio ns for source ava ila bilit y signal co ntacts Figure 5–2. Accessory 11BG module ( mounted behind operato r interface and connected to the co ntroll er) incl ude ...

  • Emerson 400A - page 17

    Fa s t/ Sl o w A d j u st Dayl ight Savi ng Time A dju st Date Time Start T Ime Engine Exerciser Run TIm e CONTRO L F EATURES (continued) 5 --- 3 How to Set Option a l Progra mm ab le En gin e Exe rcis er (p art o f Acc. 11BG mo dule) Haza rdous vol tage ca pabl e of causin g shock, burns, o r death is used in this t ransfer switch. Deenergize bo t ...

  • Emerson 400A - page 18

    CONTRO L F EATURES (continued) 5 --- 4 INPHASE M ONITOR FOR M OTOR LOAD TR ANSF ER Inphase monitori ng logic con trols tr ansfer and retransfe r of motor loads, so that inrush current s do not exceed normal starti ng currents. It a voids nuisance tripping of cir cuit breakers and m echanic al damag e to mot or co up li ngs . The Motor Load T ransfe ...

  • Emerson 400A - page 19

    CONTRO L F EATURES (continued) 5 --- 5 OPTIONAL STR IP HEA TER ( Accessory 44) A cc essory 44 Str ip Heater is design ed to keep ambient temp eratures within the A utomatic T ransfer Switc h en closu re a t a ccep ta ble le ve ls. Th i s acce sso ry co nsi s ts of a mounting bracket with strip heat er, thermosta t, and terminal block. A transformer ...

  • Emerson 400A - page 20

    INDEX Printed in U .S.A. Copy right - - - ASC O Power T echn ologies, L.P . 2011 A accessories, 5–2, 5–5 auxil iary cir cuits , 1–2 B battery , 4–2, 5–1 buttons, push, 3–1 bypass time delay, 1–5, 2–1, 3–1 C cable lugs, preparation, 1–1 cat alo g nu mber, cove r cleaning, 3–1 connections engine control contact, 1–2 line, 1– ...

Fabricante Emerson Categoría Switch

Los documentos del dispositivo Emerson 400A que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Emerson
- manuales de instrucciones 400A
- hojas de producto Emerson
- folletos informativos
- o etiquetas energéticas Emerson 400A
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Emerson 400A.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Emerson 400A, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Emerson 400A. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Emerson 400A.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Emerson 400A, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Emerson 400A. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Emerson 400A.

El manual de instrucciones completo de Emerson debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Emerson 400A - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Emerson 400A, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Emerson 400A que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Emerson 400A - que deben facilitarnos los primeros pasos durante el uso de Emerson 400A
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Emerson 400A
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Emerson 400A en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Emerson 400A?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Emerson 400A, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Emerson 400A probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen