Manual de instrucciones Nordyne B5SM -090

16 de páginas 1.72 mb
Descargar

Pasar a la página of 16

Summary
  • Nordyne B5SM -090 - page 1

    LIGHT COMMERCIAL AIR HANDLER Installation Instructions B5SM -090/120 SERIES Horizontal Application - Rear View Horizontal Application - Fr ont View V ertical Application Please read this information thor oughl y and become familiar with the capabilities and use of y our appliance before attempting to operate or maintain this unit. Keep this literat ...

  • Nordyne B5SM -090 - page 2

    2 Important Safety Information ....................................3 General Information ...................................................4 Bef ore Y ou Install this Unit .........................................4 Locating the Air Handler ............................................4 Field Connections f or Electrical P ower Supply ..........4 Air ...

  • Nordyne B5SM -090 - page 3

    3 IMPORT ANT SAFETY INFORMA TION Saf ety markings are used frequently throughout this manual to designate a degree or le v el of seriousness and should not be ignored. W ARNING indicates a potentially hazardous situation that if not av oided, could result in personal injur y or death. CA UTION indicates a potentially hazardous situation that if not ...

  • Nordyne B5SM -090 - page 4

    4 GENERAL INFORMA TION B5SM air handlers are shipped from the f actor y ready f or installation in a horizontal position. The units can be easily re- confi gured in the fi eld for v er tical applications. The return air opening is interchangeable betw een the bottom of the unit and the top panel simply by s witching the fi lter-rack with the ret ...

  • Nordyne B5SM -090 - page 5

    5 AIR HANDLER INST ALLA TION P ackaging Remo v al Remov e the shipping crate and User’ s Manual from the equipment. T ake care not to damage the tubing connections when removing the crate . Minimum Clearance Requirements This air handler must be installed with ample clearance f or easy access to the air fi lters, blo wer assemb ly , and, control ...

  • Nordyne B5SM -090 - page 6

    6 • The B5SM-120 air handler has a dual circuit coil and the B5SM-090 has a single circuit coil. • The B5SM-120 air handler is charged through ser vice v alves on the end of the liquid tube f or each circuit. These must be remo ved bef ore brazing the line sets . The B5SM-090 is charged through a ser vice v alve inside the unit, which should no ...

  • Nordyne B5SM -090 - page 7

    7 ELECTRICAL WIRING W ARNING: T o av oid risk of electrical shock , personal injury , or death, disconn ect all electrical power to the unit before per forming an y maintenance o r s e r v i c e . T h e u n i t m a y h a v e m o r e t h a n o n e electrical suppl y . Lab el all wires prior to disconnection when ser vicing the unit. Wiring errors ca ...

  • Nordyne B5SM -090 - page 8

    8 ST ARTUP AND ADJUSTMENTS Pre-Start Check List Prior to star t-up, complete the f ollo wing inspection:  V erify the unit is lev el and condensate can drain. Check condensate drain line(s) f or proper slope and trap .  V er ify the air handler is mounted securely .  V er ify the surrounding area and top of the unit is free from obstructio ...

  • Nordyne B5SM -090 - page 9

    9 Figure 3. Proper Belt T ension 1/4 inch 1 foot Pulley Alignment Inspect the pulley alignment betw een the motor sheav e and blo wer pulle y . If a misalignment occurs, adjust the location of the motor sheav e b y loosening the set-screw in the stationar y f ace of the motor sheav e. Relocate the sheav e assemb ly on the motor shaft to ensure the ...

  • Nordyne B5SM -090 - page 10

    10 13 5/8" 15 9/16" 17 11/16" 17 13/16" 4 3/16" 4 3/8" 5 11/16" 8 3/16" Air Flow Electrical Connections 2 7/32" 3/4" 1 1/4" 18 13/16" Supply Duct 22 1/16" 19 3/8" 57" Center to Center Field Installed Hanging Rods 28 1/2" C L of Unit 3" C L of Gravity 23" Retur ...

  • Nordyne B5SM -090 - page 11

    11 Figure 5. B5SM Physical Dimensions f or V er tical Installations 23" Return Duct Opening 5 1/16" 53 1/4" Cabinet Height 53" Return Duct Opening 57" Filter Rack Frame 60 1/4" Cabinet Width 18 13/16" Supply Duct Opening 22 1/16" 19 3/8" 27 3/8" Cabinet Depth (without Filter Rack) 2 16 1/4" Sup ...

  • Nordyne B5SM -090 - page 12

    12 Model Motor Sheave P osition External Static Pressures (Inches Water Column) 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw CFM RPM Kw B5SM- 090 (2HP) 60 Hz Fully Closed 4182 666 1.28 3961 667 1.20 3706 668 1.11 3436 669 1.03 3081 669 0.93 2738 672 0.83 1 T ur n Open 38 ...

  • Nordyne B5SM -090 - page 13

    13 SINGLE PHASE THREE PHASE G C W2 W1 O/B Y R G C W2 W1 O/B Y R L2 L1 G L3 L2 L1 G L1 L2 G FIELD SUPPL Y CONNECTIONS L1 L2 L3 G FIELD SUPPL Y CONNECTIONS L1 L2 T1 T2 L1 L2 T1 T2 L3 T3 208-230/460V 460 208-230 460 208 - 230 Electrical Configurations 1. Three phase units are factory wired for 460V/60Hz or 380V/50Hz operation. 2. T o reverse motor r o ...

  • Nordyne B5SM -090 - page 14

    14 Figure 7. T ypical Air conditioner Thermostat Connections BLOWER MO TOR GND T O FIELD SUPPLIED DISCONNECT SINGLE ST AGE HEA T/COOL THERMOST A T OUTDOOR SECTION FREEZEST A T SINGLE ST AGE HEA T/COOL THERMOST A T - NO ECONOMIZER AIR HANDLER SECTION TERMINAL BOARD G C W2 W1 O Y R C Y R RC G Y W L1 L2 L3 NOTE: C & W2 t o be connected to electric ...

  • Nordyne B5SM -090 - page 15

    15 Figure 8. T ypical Heat Pump Thermostat Connections BLOWER MO TER GND BLACK BLACK GREEN BRO WN T O FIELD SUPPLIED DISCONNECT SINGLE ST AGE HEA T PUMP THERMOST A T OUTDOOR SECTION NO TE 1 NO TE 2 FREEZEST A T TYPICAL HEA T PUMP THERMOST A T CONNECTION (NO ECONOMIZER) AIR HANDLER SECTION TERMINAL BOARD G C W2 O R Y W1 C Y R G Y E R O B L1 L2 L3 O ...

  • Nordyne B5SM -090 - page 16

    7090950 Specifi cations and illustrations subject to change without notice or incurring obligations. Printed in U.S .A. (01/10) Installed by: Date Installed: Maintenance T ask WM S A A A ir Filters Inspect, c lean or replace as required. x Condensate Drain(s) & Pan Clean condensate drain pan x Inspect the f low of condensate through the drain ...

Fabricante Nordyne Categoría Air Conditioner

Los documentos del dispositivo Nordyne B5SM -090 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Nordyne
- manuales de instrucciones B5SM -090
- hojas de producto Nordyne
- folletos informativos
- o etiquetas energéticas Nordyne B5SM -090
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Nordyne B5SM -090.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Nordyne B5SM -090, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Nordyne B5SM -090. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Nordyne B5SM -090.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Nordyne B5SM -090, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Nordyne B5SM -090. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Nordyne B5SM -090.

El manual de instrucciones completo de Nordyne debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Nordyne B5SM -090 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Nordyne B5SM -090, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Nordyne B5SM -090 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Nordyne B5SM -090 - que deben facilitarnos los primeros pasos durante el uso de Nordyne B5SM -090
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Nordyne B5SM -090
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Nordyne B5SM -090 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Nordyne B5SM -090?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Nordyne B5SM -090, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Nordyne B5SM -090 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)