Manual de instrucciones Cabletron Systems Expansion module 6H122-08

170 de páginas 0.51 mb
Descargar

Pasar a la página of 170

Summary
  • Cabletron Systems Expansion module 6H122-08 - page 1

    9032159-02 6H122-08 Smar tSwitch 6000 Interface Module User’ s Guide 7 8 6H122-08 FAST ENET COM CPU 100 Mbs 2 3 4 5 6 1 RESET 1X 2X 3X 4X 5X 6X ...

  • Cabletron Systems Expansion module 6H122-08 - page 2

    ...

  • Cabletron Systems Expansion module 6H122-08 - page 3

    6H122-08 User’ s Guide i NOTICE Cabletron Systems reserves the right to mak e changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes ha v e been made. The hardware, firmware, or softw are described in this man ...

  • Cabletron Systems Expansion module 6H122-08 - page 4

    Notice ii 6H122-08 User’ s Guide INDUSTRY CANADA NOTICE This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limi ...

  • Cabletron Systems Expansion module 6H122-08 - page 5

    Notice 6H122-08 User’ s Guide iii CABLETRON SOFTWARE PROGRAM LICENSE 1. LICENSE . You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions of this License Agreement. Y ou may not copy , reproduce or transmit any part of the Program e xcept as permitted by the Copyright Act of the ...

  • Cabletron Systems Expansion module 6H122-08 - page 6

    Notice iv 6H122-08 User’ s Guide DECLARATION OF CONFORMITY Application of Council Directi ve(s): 89/336/EEC 73/23/EEC Manufacturer’ s Name: Cabletron Systems, Inc. Manufacturer’ s Address: 35 Industrial Way PO Box 5005 Rochester, NH 03867 European Representati ve Name: Mr. J. Solari European Representati ve Address: Cabletron Systems Limited ...

  • Cabletron Systems Expansion module 6H122-08 - page 7

    6H122-08 User’ s Guide v CONTENTS CHAPTER 1 INTR ODUCTION 1.1 Using This Guide ......................................................................... 1-1 1.2 Structure of This Guide ................................................................ 1-1 1.3 6H122-08 Overview ..................................................................... 1- ...

  • Cabletron Systems Expansion module 6H122-08 - page 8

    Contents vi 6H122-08 User’ s Guide 3.5 Connecting to the Network ........................................................... 3-5 3.5.1 Connecting Twisted Pair Cables to Ports 1 Through 6 ... 3-5 3.5.2 Connecting a Twisted Pair Segment to the FE-100TX.... 3-7 3.5.3 Connecting a Fiber Optic Segment to the FE-100FX and FE-100F3 ..................... ...

  • Cabletron Systems Expansion module 6H122-08 - page 9

    Contents 6H122-08 User’ s Guide vii 5.12 Module Selection Screen ........................................................... 5-34 5.12.1 Selecting a Module ....................................................... 5-35 5.13 Module Menu Screen ................................................................ 5-36 5.14 Module Configuration Menu Screen ...

  • Cabletron Systems Expansion module 6H122-08 - page 10

    Contents viii 6H122-08 User’ s Guide 5.23 Port Redirect Function Screen ................................................... 5-78 5.23.1 Changing Source and Destination Ports ....................... 5-80 5.24 Broadcast Suppression Screen ................................................. 5-81 5.24.1 Setting the Threshold ........................... ...

  • Cabletron Systems Expansion module 6H122-08 - page 11

    6H122-08 User’ s Guide 1-1 CHAPTER 1 INTR ODUCTION W elcome to the Cabletron Systems 6H122-08 SmartSwitch 6000 Interface Module User’s Guide . This guide describes the 6H122-08 Interface Module and pro vides information concerning network requirements, installation, troubleshooting, and the use of Local Management. 1.1 USING THIS GUIDE Read thr ...

  • Cabletron Systems Expansion module 6H122-08 - page 12

    Chapter 1: Introduction 1-2 6H122-08 User’ s Guide Chapter 5 , Local Management , describes ho w to access Local Management and use the Local Management screens to manage the 6H122-08 and 6C105 chassis. Appendix A , Specifications , contains information on functionality and operating specifications, connector pinouts, en vironmental requirement ...

  • Cabletron Systems Expansion module 6H122-08 - page 13

    Structure of This Guide 6H122-08 User’ s Guide 1-3 Figure 1-1 The 6H122-08 2159-01 7 8 6H122-08 FAST ENET COM CPU 100 Mbs 2 3 4 5 6 1 RESET 1X 2X 3X 4X 5X 6X Reset Button System LED Port Status LEDs Network Ports 1-6 Optional Fast Ethernet Module Ports 7 and 8 COM Port ...

  • Cabletron Systems Expansion module 6H122-08 - page 14

    Chapter 1: Introduction 1-4 6H122-08 User’ s Guide 1.3 6H122-08 OVERVIEW The 6H122-08 is a Fast Ethernet interf ace module for Cabletron Systems 6C105 chassis that has six RJ45 switched ports and two optional F ast Ethernet Interface Module ports (100B ASE-TX and 100B ASE-FX) that provide T wisted Pair , Multimode, and Single Mode Fiber Optic cab ...

  • Cabletron Systems Expansion module 6H122-08 - page 15

    6H122-08 Overview 6H122-08 User’ s Guide 1-5 1.3.3 Full Duplex Switc hed Ethernet (FDSE) Each switched Fast Ethernet port on the 6H122-08 supports 10/100 Mbps operation and can be configured to operate in Full Duplex Switched Ethernet (FDSE) mode. FDSE allo ws each Fast Ethernet port to pro vide up to 200 Mbps of bandwidth. 1.3.4 Management Mana ...

  • Cabletron Systems Expansion module 6H122-08 - page 16

    Chapter 1: Introduction 1-6 6H122-08 User’ s Guide 1.3.7 LANVIEW Diagnostic LEDs LANVIEW diagnostic LEDs serve as an important troubleshooting aid by providing an easy w ay to observe the status of indi vidual ports and ov erall network operations. Chapter 4 pro vides details about the 6H122-08 LANVIEW LEDs. 1.3.8 Y ear 2000 Compliant The 6H122-0 ...

  • Cabletron Systems Expansion module 6H122-08 - page 17

    Local Management Features 6H122-08 User’ s Guide 1-7 1.4 LOCAL MANAGEMENT FEATURES Local Management provides the tools that allo w management of the 6H122-08, the Fast Ethernet Interf ace Modules, and the 6C105 chassis. Local Management for the 6H122-08 provides the features detailed in Sections 1.4.1 through 1.4.6. 1.4.1 Distrib uted Chassis Man ...

  • Cabletron Systems Expansion module 6H122-08 - page 18

    Chapter 1: Introduction 1-8 6H122-08 User’ s Guide 1.4.4 P or t Redirect Function The port redirect function, also referred to as “Port Mirroring, ” is a troubleshooting tool used to map traf fic from a single source port or multiple source ports to a destination port(s) within the chassis. This feature functions at the bit le vel, which all ...

  • Cabletron Systems Expansion module 6H122-08 - page 19

    Optional Features 6H122-08 User’ s Guide 1-9 1.4.6 Additional Local Mana g ement Functions Local Management also allo ws the following tasks to be performed: • Manage any module installed in the 6C105 via a single terminal connection. • Assign an IP address and subnet mask to the 6H122-08 and 6C105 chassis. • Select a default gate way . • ...

  • Cabletron Systems Expansion module 6H122-08 - page 20

    Chapter 1: Introduction 1-10 6H122-08 User’ s Guide 1.6 DOCUMENT CON VENTIONS The follo wing con ventions are used throughout this document: NO TE Note symbol. Calls the reader’ s attention to any item of inf or mation that ma y be of special impor tance. TIP Tip symbol. Conv eys helpful hints concer ning procedures or actions. ! CA UTION Cauti ...

  • Cabletron Systems Expansion module 6H122-08 - page 21

    Getting Help 6H122-08 User’ s Guide 1-11 1.7 GETTING HELP For additional support related to this de vice or document, contact the Cabletron Systems Global Call Center: Before calling the Cabletron Systems Global Call Center, have the following information ready: • Y our Cabletron Systems service contract number • A description of the failure ...

  • Cabletron Systems Expansion module 6H122-08 - page 22

    Chapter 1: Introduction 1-12 6H122-08 User’ s Guide 1.8 RELATED MANUALS The follo wing manuals may help the user to setup and manage the 6H122-08: Cabletron Systems HSIM-A6DP User’ s Guide Cabletron Systems HSIM-F6 User’ s Guide Cabletron Systems HSIM-FE6 User’ s Guide Cabletron Systems HSIM-W6 User’ s Guide Cabletron Systems HSIM-W84 Use ...

  • Cabletron Systems Expansion module 6H122-08 - page 23

    6H122-08 User’ s Guide 2-1 CHAPTER 2 NETW ORK REQUIREMENTS Before installing the 6H122-08 or Fast Ethernet Interf ace Modules (FE-100TX, FE-100FX, or FE-100F3), re view the requirements and specifications referred to in this chapter concerning the follo wing: • SmartT runk ( Section 2.1 ) • 10B ASE-T T wisted Pair Netw ork ( Section 2.2 ) ? ...

  • Cabletron Systems Expansion module 6H122-08 - page 24

    Chapter 2: Network Requirements 2-2 6H122-08 User’ s Guide 2.3 100B ASE-TX NETW ORK The six fixed ports of the 6H122-08, and an FE-100TX installed in ports 7 or 8, provide an RJ45 connection that supports Cate gory 5 UTP cabling with an impedance between 85 and 111 ohms. The de vice at the other end of the twisted pair segment must meet IEEE 802 ...

  • Cabletron Systems Expansion module 6H122-08 - page 25

    6H122-08 User’ s Guide 3-1 CHAPTER 3 INSTALLATION This chapter cov ers the follo wing items: • Unpacking the 6H122-08 ( Section 3.2 ) • Installing options ( Section 3.3 ) • Installing the 6H122-08 into the 6C105 chassis ( Section 3.4 ). • Connecting to the network ( Section 3.5 ) • Completing the installation ( Section 3.6 ) 3.1 REQUIRE ...

  • Cabletron Systems Expansion module 6H122-08 - page 26

    Chapter 3: Installation 3-2 6H122-08 User’ s Guide 3.3 INSTALLING OPTIONS If the 6H122-08 will be installed with an optional Fast Ethernet Interf ace Module refer to Appendix C for installation instructions. 3.4 INSTALLING THE 6H122-08 INTO THE 6C105 CHASSIS The 6H122-08 can be installed in any of the 5 slots that are a v ailable. T o install a m ...

  • Cabletron Systems Expansion module 6H122-08 - page 27

    Installing the 6H122-08 into the 6C105 Chassis 6H122-08 User’ s Guide 3-3 4. Remove the module from the plastic bag. (Save the bag in the event the module must be reshipped.) Observe all precautions to prevent damage from Electrostatic Discharge (ESD). 5. Examine the module for damage. If any damage exists, DO NOT install the module. Immediately ...

  • Cabletron Systems Expansion module 6H122-08 - page 28

    Chapter 3: Installation 3-4 6H122-08 User’ s Guide Figure 3-1 Installing an Interface Module 1 2 3 45 PS1 PS2 Plastic Locking T ab Slot Number 2159-02 2159-01 7 8 COM CPU 6E122-08 FAST ENET 100 Mbs 2 3 4 5 6 1 RESET 1X 2X 3X 4X 5X 6X Circuit Card Card Guides Metal Back-Panel Plastic Locking T ab ...

  • Cabletron Systems Expansion module 6H122-08 - page 29

    Connecting to the Netw ork 6H122-08 User’ s Guide 3-5 3.5 CONNECTING TO THE NETW ORK This section provides the procedures for connecting T wisted Pair and fiber optic segments from the netw ork or other devices to the 6H122-08. Ports 1 through 6 on the 6H122-08 ha ve RJ45 connectors for T wisted Pair connections. Ports 7 and 8 support FE-100TX, ...

  • Cabletron Systems Expansion module 6H122-08 - page 30

    Chapter 3: Installation 3-6 6H122-08 User’ s Guide . Figure 3-2 6H122-08 T wisted P air Connection 3. Verify that a link exists by checking that the port RX LED is ON (flashing amber, blinking green, or solid green). If the RX LED is OFF and the TX LED is not blinking amber, perform the following steps until it is on: a. V erify that the de vice ...

  • Cabletron Systems Expansion module 6H122-08 - page 31

    Connecting to the Netw ork 6H122-08 User’ s Guide 3-7 Figure 3-3 Cable Pinouts - (RJ45) Cr ossover Cable c. Ensure that the Twisted Pair connection meets the dB loss and cable specifications outlined in Cabletron Systems Cabling Guide. Refer to Section 1.8 , Related Manuals , for information on obtaining this document. If a link is not establishe ...

  • Cabletron Systems Expansion module 6H122-08 - page 32

    Chapter 3: Installation 3-8 6H122-08 User’ s Guide Figure 3-4 FE-100TX Crosso ver Switch Connect an FE-100TX to a T wisted P air segment as follo ws: 1. Ensure that the device connected to the other end of the segment is powered ON. 2. Connect the Twisted Pair segment to the module by inserting its RJ45 connector into the RJ45 port on the module ...

  • Cabletron Systems Expansion module 6H122-08 - page 33

    Connecting to the Netw ork 6H122-08 User’ s Guide 3-9 3.5.3 Connecting a Fiber Optic Segment to the FE-100FX and FE-100F3 The FE-100FX and FE-100F3 ha ve an SC style network port (see Figure 3-5 ). Cabletron Systems supplies fiber optic cable that uses SC style connectors that are ke yed to ensure proper crossing ov er of the transmit and recei ...

  • Cabletron Systems Expansion module 6H122-08 - page 34

    Chapter 3: Installation 3-10 6H122-08 User’ s Guide 2. Insert one end of the SC connector into the FE-100FX or FE-100F3 installed in the 6H122-08. See Figure 3-5 . 3. At the other end of the fiber optic cable, attach the SC connector to the other device. Figure 3-5 FE-100FX and FE-100F3 P or t 4. Verify that a link exists by checking that the por ...

  • Cabletron Systems Expansion module 6H122-08 - page 35

    Completing the Installation 6H122-08 User’ s Guide 3-11 3.6 COMPLETING THE INSTALLATION After installing the 6H122-08 and any optional F ast Ethernet Interface Modules the module is no w ready to be set up through Local Management. Refer to Chapter 5 to configure the module and 6C105 chassis. ...

  • Cabletron Systems Expansion module 6H122-08 - page 36

    Chapter 3: Installation 3-12 6H122-08 User’ s Guide ...

  • Cabletron Systems Expansion module 6H122-08 - page 37

    6H122-08 User’ s Guide 4-1 CHAPTER 4 T R OUBLESHOOTING This chapter provides information concerning the follo wing: • Using the LANVIEW diagnostic and status monitoring system • T roubleshooting network and module operational problems • Using the RESET b utton 4.1 USING LANVIEW The 6H122-08 uses Cabletron Systems b uilt-in visual diagnostic ...

  • Cabletron Systems Expansion module 6H122-08 - page 38

    Chapter 4: T roub leshooting 4-2 6H122-08 User’ s Guide Figure 4-1 LANVIEW LEDs 2159-07 7 8 COM CPU 6H122-08 FAST ENET 100 Mbps 2 3 4 5 6 1 RESET 1X 2X 3X 4X 5X 6X CPU LED Receive (RX) T ransmit (TX) 10/100 Mbps Operation Receive (RX) T ransmit (TX) ...

  • Cabletron Systems Expansion module 6H122-08 - page 39

    Using LANVIEW 6H122-08 User’ s Guide 4-3 T able 4-1 LANVIEW LEDs LED Color State Recommended Action CPU Off P ower off . P ower up chassis . Red Blinking . Hardware f ailure has occurred. Contact the Cabletron Systems Global Call Center . Solid . Resetting, nor mal po wer up reset. No action. Amber Blinking . Crippled. Contact the Cabletron Syste ...

  • Cabletron Systems Expansion module 6H122-08 - page 40

    Chapter 4: T roub leshooting 4-4 6H122-08 User’ s Guide T able 4-2 P or t 1-6 10/100 LED Indications 4.2 FE-100TX LED The optional FE-100TX for the 6H122-08 has one LED labeled 10/100. The 10/100 LED together with the recei ve LED allo ws the user to determine the link status and the operating speed of the Fast Ethernet Interface Module. The 10/1 ...

  • Cabletron Systems Expansion module 6H122-08 - page 41

    FE-100TX LED 6H122-08 User’ s Guide 4-5 Figure 4-2 FE-100TX LED T able 4-3 FE-100TX LED Indications NO TE A link e xists if the associated por t (por t 7 or 8) Receive (RX) LED is on. No link e xists if the associated por t (por t 7 or 8) Receiv e (RX) LED is off. LED Color Description 10/100 Off No link or no cable attached. FE-100TX is f orced ...

  • Cabletron Systems Expansion module 6H122-08 - page 42

    Chapter 4: T roub leshooting 4-6 6H122-08 User’ s Guide 4.3 T ROUB LESHOOTING CHECKLIST If the 6H122-08 is not working properly , refer to T able 4-4 for a checklist of possible problems, causes, and recommended actions to resolve the problem. T able 4-4 T roubleshooting Chec klist Prob lem P ossible Cause Recommended Action All LEDs are OFF . Lo ...

  • Cabletron Systems Expansion module 6H122-08 - page 43

    Using the RESET Button 6H122-08 User’ s Guide 4-7 4.4 USING THE RESET BUTTON The RESET b utton located near the upper plastic locking tab of the module (refer to Figure 4-3) resets the 6H122-08 processor without af fecting the NVRAM. Figure 4-3 RESET Button T o reset the 6H122-08 processor , press and release the RESET button. The module processo ...

  • Cabletron Systems Expansion module 6H122-08 - page 44

    Chapter 4: T roubleshooting 4-8 6H122-08 User’ s Guide ...

  • Cabletron Systems Expansion module 6H122-08 - page 45

    6H122-08 User’ s Guide 5-1 CHAPTER 5 LOCAL MANAGEMENT This chapter explains ho w to set up a management terminal to access 6H122-08 Local Management. It also explains ho w to use the Local Management screens and commands. 5.1 OVERVIEW Local Management for the 6H122-08 consists of a series of management screens that allo w the management of the mo ...

  • Cabletron Systems Expansion module 6H122-08 - page 46

    Chapter 5: Local Management 5-2 6H122-08 User’ s Guide 5.2 LOCAL MANAGEMENT KE YBOAR D CON VENTIONS All ke y names appear as capital letters in this manual. T able 5-1 explains the ke yboard con ventions and the ke y functions that are used. T able 5-1 Ke yboard Con ventions Ke y Function ENTER K ey RETURN K ey These are selection ke ys that perf ...

  • Cabletron Systems Expansion module 6H122-08 - page 47

    Management T erminal Setup 6H122-08 User’ s Guide 5-3 5.3 MANAGEMENT T ERMINAL SETUP Use one of the follo wing systems to access Local Management: • An IBM or compatible PC running a VT series emulation software package • A Digital Equipment Corporation VT100 type terminal • A VT type terminal running emulation programs for the Digital Equi ...

  • Cabletron Systems Expansion module 6H122-08 - page 48

    Chapter 5: Local Management 5-4 6H122-08 User’ s Guide Figure 5-1 Management T erminal Connection 2159-10 1 23 4 5 PS1 PS2 6H122-08 F AST ENET CPU 100 Mbs 2 1 RESET 7 8 6E122-08 ETHERNET COM CPU 100 Mbs 2 3 4 5 6 1 RESET 1X 2X 3X 4X 5X 6X RJ45 COM Port RJ45-to-DB9 PC Adapter to PC UTP Cable with RJ45 Connectors ...

  • Cabletron Systems Expansion module 6H122-08 - page 49

    Management T erminal Setup 6H122-08 User’ s Guide 5-5 5.3.2 Connecting an Uninterruptible P ower Suppl y If the 6C105 chassis is connected to an American Po wer Con version (APC) Uninterruptible Po wer Supply (UPS) for protection from a loss of po wer , a connection from the COM port of a module to the UPS can be made to monitor the status of the ...

  • Cabletron Systems Expansion module 6H122-08 - page 50

    Chapter 5: Local Management 5-6 6H122-08 User’ s Guide Figure 5-2 Uninterruptible P ower Supply (UPS) 2159-10 1 23 4 5 PS1 PS2 6H122-08 F AST ENET CPU 100 Mbs 2 1 RESET 7 8 6E122-08 ETHERNET COM CPU 100 Mbs 2 3 4 5 6 1 RESET 1X 2X 3X 4X 5X 6X UPS Device DB9 Port RJ45 COM Port RJ45-to-DB9 PC Adapter UTP Cable with RJ45 Connectors ...

  • Cabletron Systems Expansion module 6H122-08 - page 51

    Management T erminal Setup 6H122-08 User’ s Guide 5-7 5.3.3 Management T erminal Setup P arameters T able 5-2 lists the setup parameters for the local management terminal. T able 5-2 VT T erminal Setup Display Setup Men u Columns -> Controls -> A uto Wrap -> Scroll -> T e xt Cursor -> Cursor Style -> 80 Columns Inter pret Contro ...

  • Cabletron Systems Expansion module 6H122-08 - page 52

    Chapter 5: Local Management 5-8 6H122-08 User’ s Guide T elnet Connections Once the module or chassis has a v alid IP address, the user can establish a T elnet session with Local Management from any TCP/IP based node on the network. T elnet connections to the 6H122-08 require the community name passwords assigned at the SNMP Community Names scree ...

  • Cabletron Systems Expansion module 6H122-08 - page 53

    Accessing Local Management 6H122-08 User’ s Guide 5-9 5.4 ACCESSING LOCAL MANAGEMENT Access to Local Management is controlled through the Passw ord screen, Figure 5-3 . Whene ver a connection is made to the 6H122-08 the Passw ord screen displays. Before continuing, the user must enter a password which is compared to the pre viously stored passwor ...

  • Cabletron Systems Expansion module 6H122-08 - page 54

    Chapter 5: Local Management 5-10 6H122-08 User’ s Guide • If an in valid passw ord is entered, the terminal beeps and the cursor returns to the beginning of the passw ord entry field. • Entering a v alid password causes the associated access le vel to display at the bottom of the screen and the Main Menu screen to appear . • If no acti vit ...

  • Cabletron Systems Expansion module 6H122-08 - page 55

    Accessing Local Management 6H122-08 User’ s Guide 5-11 Figure 5-4 802.1D Switching Mode, LM Screen Hierarc hy Figure 5-5 802.1Q Switching Mode, LM Screen Hierarc hy Module Menu Password Main Menu SNMP Community Names Chassis Menu General Configuration SNMP T raps Chassis Environmental Port Redirect Function Module Configuration Menu Module Spec ...

  • Cabletron Systems Expansion module 6H122-08 - page 56

    Chapter 5: Local Management 5-12 6H122-08 User’ s Guide Figure 5-6 SecureFast VLAN Mode , LM Screen Hierarch y 5.4.2 Selecting Local Management Menu Screen Items Select items on a menu screen by performing the follo wing steps: 1. Use the arrow keys to highlight a menu item. 2. Press ENTER. The selected menu item displays on the screen. 5.4.3 Exi ...

  • Cabletron Systems Expansion module 6H122-08 - page 57

    Accessing Local Management 6H122-08 User’ s Guide 5-13 Using the Return Command T o e xit a Local Management using the RETURN command, proceed as follo ws: 1. Use the arrow keys to highlight the RETURN command at the bottom of the Local Management screen. 2. Press ENTER . The previous screen in the Local Management hierarchy displays. 3. Exit fro ...

  • Cabletron Systems Expansion module 6H122-08 - page 58

    Chapter 5: Local Management 5-14 6H122-08 User’ s Guide 5.5 THE MAIN MENU SCREEN The Main Menu Screen is the access point for all Local Management screens for the module and the 6C105 chassis. Figure 5-7 sho ws the Main Menu screen. Figure 5-7 Main Menu Screen The follo wing explains each Main Menu screen selection as sho wn in Figure 5-7 : CHASS ...

  • Cabletron Systems Expansion module 6H122-08 - page 59

    Chassis Menu Screen 6H122-08 User’ s Guide 5-15 MODULES The MODULES menu item provides access to the Module Selection screen that is used to select indi vidual modules in the chassis for management purposes. Access the Module Selection screen by using the arro w keys to highlight the MODULES menu item and pressing ENTER. The Module Selection scre ...

  • Cabletron Systems Expansion module 6H122-08 - page 60

    Chapter 5: Local Management 5-16 6H122-08 User’ s Guide The follo wing briefly explains each screen accessible from the Chassis Menu screen. CHASSIS CONFIGURA TION The Chassis Configuration screen allo ws the user to configure operating parameters for the 6C105 chassis. For details, refer to Section 5.7 . SNMP COMMUNITY NAMES The SNMP Communit ...

  • Cabletron Systems Expansion module 6H122-08 - page 61

    Chassis Configuration Screen 6H122-08 User’ s Guide 5-17 Access the Chassis Configuration screen from the Chassis Menu screen by using the arro w keys to highlight the CHASSIS CONFIGURA TION menu item and pressing ENTER. The Chassis Configuration screen, Figure 5-9 , displays. Figure 5-9 Chassis Configuration Screen The follo wing briefly ex ...

  • Cabletron Systems Expansion module 6H122-08 - page 62

    Chapter 5: Local Management 5-18 6H122-08 User’ s Guide Subnet Mask (Modifiab le) Displays the subnet mask for the chassis. A subnet mask “masks out” the network bits of the IP address by setting the bits in the mask to 1 when the network treats the corresponding bits in the IP address as part of the network or subnetw ork address, or to 0 i ...

  • Cabletron Systems Expansion module 6H122-08 - page 63

    Chassis Configuration Screen 6H122-08 User’ s Guide 5-19 Screen Loc kout Time (Modifiab le) Contains the maximum number of minutes that the Local Management application displays a module’ s screen while aw aiting input or action from a user . For e xample, if the number 5 is entered in this field, the user has up to five minutes to respond ...

  • Cabletron Systems Expansion module 6H122-08 - page 64

    Chapter 5: Local Management 5-20 6H122-08 User’ s Guide 3. Press ENTER. If the IP address is a valid format, the cursor returns to the beginning of the IP address field. If the entry is not valid, the Event Message Line displays “INVALID IP ADDRESS OR FORMAT ENTERED”. Local Management does not alter the current value and refreshes the IP addr ...

  • Cabletron Systems Expansion module 6H122-08 - page 65

    Chassis Configuration Screen 6H122-08 User’ s Guide 5-21 5.7.3 Setting the Chassis Date The 6C105 is year 2000 compliant, so the Chassis Date may be set beyond the year 1999. T o set the chassis date, perform the follo wing steps: 1. Use the arrow keys to highlight the Chassis Date field. 2. Enter the date in an MM/DD/YYYY format. 3. Press ENTER ...

  • Cabletron Systems Expansion module 6H122-08 - page 66

    Chapter 5: Local Management 5-22 6H122-08 User’ s Guide 4. Use the arrow keys to highlight the SAVE command at the bottom of the screen and press ENTER. If the time entered is a v alid format, the Event Message Line at the top of the screen displays “SA VED OK”. If the entry is not v alid, Local Management does not alter the current v alue an ...

  • Cabletron Systems Expansion module 6H122-08 - page 67

    Chassis Configuration Screen 6H122-08 User’ s Guide 5-23 If the time entered is within the 1 to 30 minutes range, the Event Message Line at the top of the screen displays “SA VED OK”. If the entry is not v alid, Local Management does not alter the current setting, but it does refresh the Screen Lockout T ime field with the previous v alue. ...

  • Cabletron Systems Expansion module 6H122-08 - page 68

    Chapter 5: Local Management 5-24 6H122-08 User’ s Guide 5.8 SNMP COMM UNITY NAMES SCREEN The SNMP Community Names menu item allo ws the user to set Local Management community names. Community names act as passwords to Local/Remote Management and provide security access to the 6C105. Access to the 6C105 is controlled by enacting any of three dif f ...

  • Cabletron Systems Expansion module 6H122-08 - page 69

    SNMP Comm unity Names Screen 6H122-08 User’ s Guide 5-25 Figure 5-11 The SNMP Community Names Screen The follo wing explains each SNMP Community Names screen field: Comm unity Name (Modifiab le) Displays the user -defined name through which a user accesses 6C105 management. Any community name assigned here acts as a passw ord to Local/Remote M ...

  • Cabletron Systems Expansion module 6H122-08 - page 70

    Chapter 5: Local Management 5-26 6H122-08 User’ s Guide super -user This community name permits read-write access to the 6C105 MIB objects and allo ws the user to change all modifiable parameters including community names, IP addresses, traps, and SNMP objects. 5.8.1 Establishing Comm unity Names The password used to access Local Management at t ...

  • Cabletron Systems Expansion module 6H122-08 - page 71

    SNMP T raps Screen 6H122-08 User’ s Guide 5-27 5.9 SNMP T RAPS SCREEN Since the 6C105 is an SNMP compliant de vice, it can send messages to multiple Network Management Stations to alert users of status changes. The SNMP T raps screen is sho wn in Figure 5-12 . Access the SNMP T raps screen from the Chassis Menu screen by using the arro w keys to ...

  • Cabletron Systems Expansion module 6H122-08 - page 72

    Chapter 5: Local Management 5-28 6H122-08 User’ s Guide Enable Traps (T oggle) Enables transmission of the traps to the network management station with the associated IP address. This field toggles between YES and NO. 5.9.1 Configuring the T rap T able T o configure the T rap table, proceed as follows: 1. Using the arrow keys, highlight the ap ...

  • Cabletron Systems Expansion module 6H122-08 - page 73

    Chassis En vir onmental Screen 6H122-08 User’ s Guide 5-29 5.10 CHASSIS EN VIRONMENTAL SCREEN The Chassis En vironmental menu item allows the user to vie w chassis en vironmental information. Access the Chassis En vironmental Information screen from the Chassis Menu screen by using the arro w keys to highlight the CHASSIS ENVIR ONMENT AL menu ite ...

  • Cabletron Systems Expansion module 6H122-08 - page 74

    Chapter 5: Local Management 5-30 6H122-08 User’ s Guide 5.11 P OR T REDIRECT FUNCTION SCREEN The Port Redirect Function screen, Figure 5-14 , allo ws the user to set each one of the modules in the chassis (1 through 5), and the ports of the corresponding module installed, as a source or destination port. A port can be set to ha ve one or more des ...

  • Cabletron Systems Expansion module 6H122-08 - page 75

    P or t Redirect Function Screen 6H122-08 User’ s Guide 5-31 Figure 5-14 P or t Redirect Function Screen The follo wing definitions briefly explain each field of the Port Redirect Function screen. Sour ce Module (Read-Only) Displays which modules are currently set as source modules. Sour ce P or t (Read-Only) Displays which ports are currently ...

  • Cabletron Systems Expansion module 6H122-08 - page 76

    Chapter 5: Local Management 5-32 6H122-08 User’ s Guide Sour ce P or t [ n ] (Selectab le) Allo ws a selected port [ n ] to be configured as a source port. Destination Module [ n ] (Selectab le) Allo ws a selected module [ n ] to be configured as a destination module. Destination P or t [ n ] (Selectab le) Allo ws a selected port [ n ] to be co ...

  • Cabletron Systems Expansion module 6H122-08 - page 77

    P or t Redirect Function Screen 6H122-08 User’ s Guide 5-33 5.11.2 Changing Sour ce and Destination P or ts Add or delete source/destination module and port entries as follo ws: 1. Use the arrow keys to highlight the Source Module field. 2. Press the SPACE bar or BACKSPACE one or more times to increment or decrement the module number displayed in ...

  • Cabletron Systems Expansion module 6H122-08 - page 78

    Chapter 5: Local Management 5-34 6H122-08 User’ s Guide 5.12 MODULE SELECTION SCREEN The Module Selection screen is the access point to Local Management for all modules installed in the SmartSwitch 6000 chassis. By selecting a module, the Module Menu for the selected de vice displays. Figure 5-15 sho ws the Module Selection screen. Figure 5-15 Mo ...

  • Cabletron Systems Expansion module 6H122-08 - page 79

    Module Selection Screen 6H122-08 User’ s Guide 5-35 Serial # (Read-only) Indicates the serial number of the module. The serial number of the de vice is necessary when calling the Cabletron Systems Global Call Center . Har dware Re vision (Read-only) Reflects the hardware v ersion of the module. 5.12.1 Selecting a Module T o select an indi vidual ...

  • Cabletron Systems Expansion module 6H122-08 - page 80

    Chapter 5: Local Management 5-36 6H122-08 User’ s Guide 5.13 MODULE MENU SCREEN The Module Menu screen is the access point for all Local Management screens for the 6H122-08. Figure 5-16 sho ws the 6H122-08 Module Menu screen. Figure 5-16 Module Menu Screen The follo wing explains each Module Menu screen field as sho wn in Figure 5-16 : MODULE CO ...

  • Cabletron Systems Expansion module 6H122-08 - page 81

    Module Configuration Menu Screen 6H122-08 User’ s Guide 5-37 MODULE ST A TISTICS The Module Statistics screen provides statistics and performance information for the 6H122-08. For details about this screen, refer to Section 5.25 . NETW ORK T OOLS The Network T ools function resides on the 6H122-08 and consists of a series of commands that allo w ...

  • Cabletron Systems Expansion module 6H122-08 - page 82

    Chapter 5: Local Management 5-38 6H122-08 User’ s Guide Figure 5-17 Module Configuration Menu Screen The follo wing briefly explains each screen accessible from the Module Configuration Menu screen: GENERAL CONFIGURA TION The General Configuration screen allo ws the user to monitor and configure operating parameters for the 6H122-08. For det ...

  • Cabletron Systems Expansion module 6H122-08 - page 83

    Module Configuration Menu Screen 6H122-08 User’ s Guide 5-39 SWITCH CONFIGURATION The Switch Configuration screen provides basic setup options for modifying the switching functions of the modules. For details, refer to Section 5.18 . ETHERNET INTERFACE CONFIGURATION The Ethernet Interface Configuration screen indicates the link status, current ...

  • Cabletron Systems Expansion module 6H122-08 - page 84

    Chapter 5: Local Management 5-40 6H122-08 User’ s Guide 5.15 GENERAL CONFIGURATION SCREEN The General Configuration screen, Figure 5-18 , allo ws the user to set the system date and time, IP address and subnet mask, the default gate way , the TFTP Gate way IP address, the Operational Mode, the Management Mode, and the COM port configuration. Th ...

  • Cabletron Systems Expansion module 6H122-08 - page 85

    General Configuration Screen 6H122-08 User’ s Guide 5-41 IP Address (Modifiab le) This field allo ws the IP address to be set for the 6H122-08. T o set the IP address, refer to Section 5.15.1 . Subnet Mask (Modifiab le) Displays the subnet mask for the module. A subnet mask “masks out” the network bits of the IP address by setting the bit ...

  • Cabletron Systems Expansion module 6H122-08 - page 86

    Chapter 5: Local Management 5-42 6H122-08 User’ s Guide Screen Loc kout Time (Modifiab le) Contains the maximum number of minutes that the Local Management application displays a module’ s screen while aw aiting input or action from a user . For e xample, if the number 5 is entered in this field, the user has up to five minutes to respond to ...

  • Cabletron Systems Expansion module 6H122-08 - page 87

    General Configuration Screen 6H122-08 User’ s Guide 5-43 Management Mode (T oggle) This field toggles between DISTRIBUTED and ST AND ALONE. In DISTRIBUTED mode, Local Management is entered via the 6C105 password screen, and all chassis configuration screens are a v ailable to the user . All other modules installed in the chassis that are set f ...

  • Cabletron Systems Expansion module 6H122-08 - page 88

    Chapter 5: Local Management 5-44 6H122-08 User’ s Guide Clear NVRAM (T oggle) This allo ws the user to reset NVRAM to the factory default settings. All user -entered parameters, such as IP address and Community Names are then replaced with 6H122-08 default configuration settings. F or details, refer to Section 5.15.13 . IP Fragmentation (T oggle ...

  • Cabletron Systems Expansion module 6H122-08 - page 89

    General Configuration Screen 6H122-08 User’ s Guide 5-45 Figure 5-19 Configuration W arning Screen 5. Use the arrow keys to highlight the YES command. Press ENTER. The changes are saved and the module reboots. 5.15.2 Setting the Subnet Mask If the management workstation that is to recei ve SNMP traps from the 6H122-08 is located on a separate s ...

  • Cabletron Systems Expansion module 6H122-08 - page 90

    Chapter 5: Local Management 5-46 6H122-08 User’ s Guide 4. Use the arrow keys to highlight the SAVE command, then press ENTER. The warning screen shown in Figure 5-19 displays. 5. Use the arrow keys to highlight the YES command and press ENTER. The changes are saved and the module reboots. 5.15.3 Setting the Default Gatewa y If the SNMP managemen ...

  • Cabletron Systems Expansion module 6H122-08 - page 91

    General Configuration Screen 6H122-08 User’ s Guide 5-47 3. Press ENTER. If the TFTP gateway IP address entered is a valid format, the cursor returns to the beginning of the TFTP Gateway IP Address field. If the entry is not valid, the Event Message Line displays “INVALID TFTP GATEWAY IP ADDRESS OR FORMAT ENTERED”. Local Management does not ...

  • Cabletron Systems Expansion module 6H122-08 - page 92

    Chapter 5: Local Management 5-48 6H122-08 User’ s Guide 5.15.6 Setting the Module Time T o set the module clock, perform the follo wing steps: 1. Use the arrow keys to highlight the Module Time field. 2. Enter the time in an 24-hour format, HH:MM:SS. 3. Press ENTER to set the system clock to the time in the input field. 4. Use the arrow keys to h ...

  • Cabletron Systems Expansion module 6H122-08 - page 93

    General Configuration Screen 6H122-08 User’ s Guide 5-49 5.15.8 Setting the Screen Loc kout Time The screen lockout time can be set from 1 to 30 minutes with a def ault of 15 minutes. T o set a ne w lockout time, perform the follo wing steps: 1. Use the arrow keys to highlight the Screen Lockout Time field. 2. Enter a number from 1 to 30. 3. Pre ...

  • Cabletron Systems Expansion module 6H122-08 - page 94

    Chapter 5: Local Management 5-50 6H122-08 User’ s Guide 2. Press the SPACE bar to step to the appropriate operation mode, ( 802.1D SWITCHING , 802.1Q SWITCHING , or SECURE FAST VLAN ). 3. Use the arrow keys to highlight the SAVE command, then press ENTER. The warning screen shown in Figure 5-19 displays. 4. Use the arrow keys to highlight the YES ...

  • Cabletron Systems Expansion module 6H122-08 - page 95

    General Configuration Screen 6H122-08 User’ s Guide 5-51 5.15.11 Configuring the COM P or t The 6H122-08 COM port supports the follo wing applications: • Local Management connections • American Po wer Con version Uninterruptible Po wer Supply (UPS) connections T o configure the COM port, proceed as follo ws: 1. Use the arrow keys to highli ...

  • Cabletron Systems Expansion module 6H122-08 - page 96

    Chapter 5: Local Management 5-52 6H122-08 User’ s Guide Figure 5-20 COM P or t W arning Screen 3. Use the arrow keys to highlight YES . Press ENTER. 4. If you ENABLED the port, proceed to Section 5.15.12 . If you DISABLED the port, use the arrow keys to highlight SAVE at the bottom of the screen, then press ENTER. When the message “SAVED OK” ...

  • Cabletron Systems Expansion module 6H122-08 - page 97

    General Configuration Screen 6H122-08 User’ s Guide 5-53 5.15.12 Changing the Com P or t Application After enabling the COM port as described in Section 5.15.11 , you can select one of the applications supported by the COM port: LM, and UPS. The default application is LM. T o change the COM port application: 1. Use the arrows keys to highlight t ...

  • Cabletron Systems Expansion module 6H122-08 - page 98

    Chapter 5: Local Management 5-54 6H122-08 User’ s Guide 5.15.13 Clearing NVRAM Clearing NVRAM allo ws the user to clear all user-entered parameters, such as IP address and Community Names from NVRAM. Clear NVRAM as follo ws: 1. Use the arrow keys to highlight the Clear NVRAM field. 2. Use the SPACE bar to toggle the field to YES . 3. Use the arro ...

  • Cabletron Systems Expansion module 6H122-08 - page 99

    SNMP Comm unity Names Screen 6H122-08 User’ s Guide 5-55 5.15.14 Enabling/Disab ling IP Fragmentation T o enable or disable IP fragmentation, proceed as follo ws: 1. Use the arrow keys to highlight the IP Fragmentation field. 2. Press the SPACE bar to choose either ENABLED or DISABLED . 3. Use the arrow keys to highlight the SAVE command. 4. Pres ...

  • Cabletron Systems Expansion module 6H122-08 - page 100

    Chapter 5: Local Management 5-56 6H122-08 User’ s Guide Access the SNMP Community Names screen from the Module Configuration Menu screen by using the arro w keys to highlight the SNMP COMMUNITY N AMES menu item and pressing ENTER. The SNMP Community Names screen, Figure 5-22 , displays. Figure 5-22 SNMP Community Names Screen The follo wing expl ...

  • Cabletron Systems Expansion module 6H122-08 - page 101

    SNMP Comm unity Names Screen 6H122-08 User’ s Guide 5-57 read-write This community name allo ws read and write access to the 6H122-08 MIB objects, excluding security protected fields for super -user access only . super -user This community name permits read-write access to the 6H122-08 MIB objects and allo ws the user to change all modifiable p ...

  • Cabletron Systems Expansion module 6H122-08 - page 102

    Chapter 5: Local Management 5-58 6H122-08 User’ s Guide 5.17 SNMP T RAPS SCREEN Since the 6H122-08 is an SNMP compliant de vice, it can send messages to multiple Network Management Stations to alert users of status changes. The SNMP T raps screen is sho wn in Figure 5-23 . Access the SNMP T raps screen from the Module Configuration Menu screen b ...

  • Cabletron Systems Expansion module 6H122-08 - page 103

    SNMP T raps Screen 6H122-08 User’ s Guide 5-59 Trap Community Name (Modifiab le) Displays the Community Name included in the trap message sent to the Network Management Station with the associated IP address. Enable Traps (T oggle) Enables transmission of the traps to the network management station with the associated IP address. This field tog ...

  • Cabletron Systems Expansion module 6H122-08 - page 104

    Chapter 5: Local Management 5-60 6H122-08 User’ s Guide 5.18 SWITCH CONFIGURATION SCREEN The Switch Configuration screen, Figure 5-24 , provides the basic setup options to modify switch operations in your network. Access the Switch Configuration screen from the Module Configuration Menu screen by using the arro w keys to highlight the SWITCH C ...

  • Cabletron Systems Expansion module 6H122-08 - page 105

    Switch Configuration Screen 6H122-08 User’ s Guide 5-61 Figure 5-24 Switch Configuration Screen The follo wing describe each field of the Switch Configuration screen: Switch Address (Read-Only) Displays the base MA C address of the switch. Number of Ports (Read-Only) Displays the total number of switched ports on the module. Type of STA (Sele ...

  • Cabletron Systems Expansion module 6H122-08 - page 106

    Chapter 5: Local Management 5-62 6H122-08 User’ s Guide Port # (Read-Only) Lists each switch port on the module. If the number of ports is greater than eight, then the additional ports are listed on subsequent screens. MAC Address (Read-Only) Displays the hardware address assigned to each listed port. State (Read-Only) Disabled: Management disabl ...

  • Cabletron Systems Expansion module 6H122-08 - page 107

    Switch Configuration Screen 6H122-08 User’ s Guide 5-63 3. Use the arrow keys to highlight the SAVE command at the bottom of the screen. 4. Press ENTER. The message “SAVED OK” is displayed. 5.18.2 Setting the Age Time T o set the Age T ime, proceed as follo ws: 1. Use the arrow keys to highlight the Age Time field. 2. Enter the desired Age T ...

  • Cabletron Systems Expansion module 6H122-08 - page 108

    Chapter 5: Local Management 5-64 6H122-08 User’ s Guide 5.19 ETHERNET INTERFACE CONFIGURATION Access the Ethernet Interface Configuration screen from the Module Specific Configuration Menu screen by using the arro w keys to highlight the ETHERNET INTERF A CE CONFIGURA TION menu item and pressing ENTER. The Ethernet Interface Configuration scr ...

  • Cabletron Systems Expansion module 6H122-08 - page 109

    Ethernet Interface Configuration 6H122-08 User’ s Guide 5-65 Link Status (Read-Only) Indicates whether or not there is a physical connection from a particular port to another 10B ASE-T , 100B ASE-TX/FX, or 100B ASE-TXFD/FXFD de vice. One of the follo wing values is displayed: • Link – There is a link signal present and a v alid physical conn ...

  • Cabletron Systems Expansion module 6H122-08 - page 110

    Chapter 5: Local Management 5-66 6H122-08 User’ s Guide Advertised Ability (Selectable) During auto-negotiation, the FE-100TX “tells” the de vice at the other end of the segment what its capabilities are. The capabilities of a port with an FE-100TX installed, are 10B ASE-T , 10B ASE-TFD (full duplex mode), 100B ASE-TX and 100B ASE-TXFD (full ...

  • Cabletron Systems Expansion module 6H122-08 - page 111

    Ethernet Interface Configuration 6H122-08 User’ s Guide 5-67 2. Use the SPACE bar to select the desired mode. Press ENTER. If any mode other than Auto-Negotiation is selected, the port only operates in the chosen mode and auto-negotiation is disabled. 3. Use the arrow keys to highlight the SAVE command. Press ENTER. The message “SAVED OK” di ...

  • Cabletron Systems Expansion module 6H122-08 - page 112

    Chapter 5: Local Management 5-68 6H122-08 User’ s Guide 5.19.4 Configuring an FE-100FX or FE-100F3 Interface f or P or t 7 or 8 When an FE-100FX or FE-100F3 is installed in port 7 or 8, it must be manually set to operate in the same technology as the de vice at the other end of the connected segment. Section 5.19.5 pro vides instructions for man ...

  • Cabletron Systems Expansion module 6H122-08 - page 113

    Module Specific Configuration Menu Screen 6H122-08 User’ s Guide 5-69 5.20 MODULE SPECIFIC CONFIGURATION MENU SCREEN The Module Specific Configuration Menu screen, Figure 5-26 , allo ws the user to select one of five screens to configure ports or check system resources specific to the 6H122-08. Access the Module Specific Configuration Me ...

  • Cabletron Systems Expansion module 6H122-08 - page 114

    Chapter 5: Local Management 5-70 6H122-08 User’ s Guide Figure 5-26 Module Specific Configuration Menu Screen The follo wing explains each field of the Module Specific Configuration Menu screen: SYSTEM RESOURCES The System Resources screen displays the amount of FLASH memory , DRAM, and NVRAM installed, details ho w much memory is av ailable ...

  • Cabletron Systems Expansion module 6H122-08 - page 115

    Module Specific Configuration Menu Screen 6H122-08 User’ s Guide 5-71 BR O ADCAST SUPPRESSION The Broadcast Suppression screen allo ws the user to set a desired limit of recei ve broadcast frames per port per second. F or details, refer to Section 5.24 . 802.1Q VLAN CONFIGURA TION This menu item will only display if the module has been configu ...

  • Cabletron Systems Expansion module 6H122-08 - page 116

    Chapter 5: Local Management 5-72 6H122-08 User’ s Guide 5.21 SYSTEM RESOUR CES SCREEN The System Resources screen, Figure 5-27 , provides information concerning the processor used in the 6H122-08 and the amount of FLASH memory , DRAM, and NVRAM that is installed and how much of this memory is a vailable. Access the System Resources screen from th ...

  • Cabletron Systems Expansion module 6H122-08 - page 117

    System Resour ces Screen 6H122-08 User’ s Guide 5-73 DRAM Installed (Read-only) Indicates the amount of DRAM installed in the 6H122-08 and ho w much of it is currently a vailable. NVRAM Installed (Read-only) Indicates the amount of NVRAM installed in the 6H122-08 and ho w much of it is currently a vailable. Current Switch Utilization (Read-only) ...

  • Cabletron Systems Expansion module 6H122-08 - page 118

    Chapter 5: Local Management 5-74 6H122-08 User’ s Guide 5.22 FLASH DOWNLOAD SCREEN The Flash Do wnload screen, shown in Figure 5-28 , allo ws the user to clear the information stored in the 6H122-08 FLASH memory and do wnload a new image file from a TFTP server . Before do wnloading a new image to the module, load the image onto the network TFTP ...

  • Cabletron Systems Expansion module 6H122-08 - page 119

    Flash Download Screen 6H122-08 User’ s Guide 5-75 The follo wing briefly explains each field of the Flash Do wnload screen: Download Method (Selectab le) This field steps through TFTP , RUNTIME and BOOTP . If set for BOO TP , the module sends out a BootP request to determine the IP address of the TFTP server and the filename of the image to b ...

  • Cabletron Systems Expansion module 6H122-08 - page 120

    Chapter 5: Local Management 5-76 6H122-08 User’ s Guide If TFTP or RUNTIME is selected as the do wnload method ( Figure 5-28 ), the follo wing two additional fields appear: Download Server IP (Selectab le) The IP address of the TFTP serv er to be used for the FLASH do wnload is entered in this field. Download File Name (Selectab le) The complet ...

  • Cabletron Systems Expansion module 6H122-08 - page 121

    Flash Download Screen 6H122-08 User’ s Guide 5-77 5.22.2 Image File Download Using R UNTIME Set the 6H122-08 to do wnload to FLASH using R UNTIME as follows: 1. Use the arrow keys to highlight the Download Method field. 2. Use the SPACE bar to select RUNTIME . 3. Use the arrow keys to highlight the Reboot After Download field. 4. Use the SPACE ba ...

  • Cabletron Systems Expansion module 6H122-08 - page 122

    Chapter 5: Local Management 5-78 6H122-08 User’ s Guide 5.22.3 Image File Download Using BootP Set the 6H122-08 to do wnload to FLASH using BootP as follows: 1. Use the arrow keys to highlight the Download Method field. 2. Use the SPACE bar to select BOOTP . 3. Use the arrow keys to highlight the TFTP Gateway IP Addr field. Set the IP address of ...

  • Cabletron Systems Expansion module 6H122-08 - page 123

    P or t Redirect Function Screen 6H122-08 User’ s Guide 5-79 Access the Port Redirect Function screen from the Module Specific Configuration Menu screen by using the arro w keys to highlight the POR T REDIRECT FUNCTION menu item and pressing ENTER. The Port Redirect Function screen displays. Figure 5-29 P or t Redirect Function Screen The follo ...

  • Cabletron Systems Expansion module 6H122-08 - page 124

    Chapter 5: Local Management 5-80 6H122-08 User’ s Guide Err ors (T oggle) Allo ws the user to configure the source ports to either send errored frames to selected destination ports, or to drop errored frames, and send only v alid traf fic to the destination ports. The def ault setting of this field is ON. Status (T oggle) Allo ws you to add or ...

  • Cabletron Systems Expansion module 6H122-08 - page 125

    Br oadcast Suppression Screen 6H122-08 User’ s Guide 5-81 5.24 BR OADCAST SUPPRESSION SCREEN The Broadcast Suppression screen, Figure 5-30 , allo ws the user to set a desired limit of recei ve broadcast frames per port per second. Access the Broadcast Suppression screen from the Module Specific Configuration screen by using the arro w keys to h ...

  • Cabletron Systems Expansion module 6H122-08 - page 126

    Chapter 5: Local Management 5-82 6H122-08 User’ s Guide The follo wing explains each field of the Broadcast Statistics screen: POR T # (Read-only) Identifies the number of the port. T otal RX (Read-Only) Displays the total number of broadcast frames recei ved. P eak Rate (Read-Only) Displays the number of broadcast frames recei ved per second. ...

  • Cabletron Systems Expansion module 6H122-08 - page 127

    Module Statistics Menu Screen 6H122-08 User’ s Guide 5-83 5.24.2 Setting the Reset P eak Switch T o set the Reset Peak Switch field to YES or NO , proceed as follows: 1. Use the arrow keys to highlight the Reset Peak field for the selected port. 2. Press the SPACE bar to select YES or NO . 3. Use the arrows keys to highlight the SAVE command at ...

  • Cabletron Systems Expansion module 6H122-08 - page 128

    Chapter 5: Local Management 5-84 6H122-08 User’ s Guide Figure 5-31 Module Statistics Menu Screen The Module Statistics Menu screen displays the follo wing menu items: SWITCH ST A TISTICS The Switch Statistics screen lists the number of frames recei ved, transmitted, filtered, and forwarded by each interf ace. INTERF A CE ST A TISTICS The Interf ...

  • Cabletron Systems Expansion module 6H122-08 - page 129

    Switch Statistics Screen 6H122-08 User’ s Guide 5-85 5.26 SWITCH STATISTICS SCREEN The Switch Statistics screen, Figure 5-32 , lists the number of frames recei v ed, transmitted, filtered, and forw arded by each interf ace, including backplane interfaces. Access the Switch Statistics screen from the Module Statistics Menu screen by using the arr ...

  • Cabletron Systems Expansion module 6H122-08 - page 130

    Chapter 5: Local Management 5-86 6H122-08 User’ s Guide The Switch Statistics screen displays the follo wing items: Po r t # (Read-Only) Identifies the interface or port number . Frames Rcvd (Read-Only) Displays the number of frames recei ved by the interface. Frames Txmtd (Read-Only) Displays the number of frames transmitted by the interface. F ...

  • Cabletron Systems Expansion module 6H122-08 - page 131

    The Interface Statistics Screen 6H122-08 User’ s Guide 5-87 5.27 THE INTERFACE STATISTICS SCREEN The Interface Statistics screen is used to gather MIB-II statistics for all of the 6H122-08 interfaces (ports 1 through 6, optional F ast Ethernet Interface Modules and all backplane interf aces). Access the Interface Statistics screen by using the ar ...

  • Cabletron Systems Expansion module 6H122-08 - page 132

    Chapter 5: Local Management 5-88 6H122-08 User’ s Guide Name (Read-only) The Name field displays the type of interface for which statistics are being displayed. InOctets (Read-only) This field displays the total number of octets (bytes) that ha ve been recei ved on the interface. This includes all octets from bad frames, and framing characters. ...

  • Cabletron Systems Expansion module 6H122-08 - page 133

    The Interface Statistics Screen 6H122-08 User’ s Guide 5-89 OutNonUnicast (Read-only) This field displays the total number of frames transmitted to a broadcast or multicast address. OutDiscar ds (Read-only) The OutDiscards field displays the total number of outbound frames that were discarded, e ven though the frames contained no errors. This ? ...

  • Cabletron Systems Expansion module 6H122-08 - page 134

    Chapter 5: Local Management 5-90 6H122-08 User’ s Guide Link Status (Read-only) This field displays the current link status of the interface. This field will read either “Link” or “No Link”. Duplex Mode (Read-only) This field indicates whether the interface is operating in normal or full duplex mode. This field will read either “Sta ...

  • Cabletron Systems Expansion module 6H122-08 - page 135

    RMON Statistics Screen 6H122-08 User’ s Guide 5-91 5.28 RMON STATISTICS SCREEN RMON statistics for each interface, on a interf ace-by-interface basis, are vie wed through the RMON Statistics screen shown in Figure 5-34 . Access the RMON Statistics screen by using the arro w keys to highlight the RMON ST A TISTICS menu item on the Module Statistic ...

  • Cabletron Systems Expansion module 6H122-08 - page 136

    Chapter 5: Local Management 5-92 6H122-08 User’ s Guide The follo wing definitions explain each field of the RMON Statistics screen: RMON Index (Read-only) This field displays the current Ethernet interface for which statistics are being sho wn. The 6H122-08 has an embedded RMON agent that gathers statistics for each interface on the module. D ...

  • Cabletron Systems Expansion module 6H122-08 - page 137

    RMON Statistics Screen 6H122-08 User’ s Guide 5-93 Multicasts (Read-only) The Multicasts field displays the total number of good frames recei ved that were directed to a multicast address. The v alue of this field does not include frames directed to the broadcast address. CRC Align Err ors (Read-only) This field displays the number of frames w ...

  • Cabletron Systems Expansion module 6H122-08 - page 138

    Chapter 5: Local Management 5-94 6H122-08 User’ s Guide T otal Octets (Read-only) This field displays the total number of octets (bytes) of data, including those in bad frames, recei ved on this interface. 64 Octets (Read-only) Displays the total number of frames including bad frames, recei ved that were 64 bytes in length (excluding framing bit ...

  • Cabletron Systems Expansion module 6H122-08 - page 139

    RMON Statistics Screen 6H122-08 User’ s Guide 5-95 5.28.1 Displa ying RMON Statistics T o display the statistics for an y index, proceed as follo ws: 1. Use the arrow keys to highlight the Index [XX] field at the bottom of the screen. 2. Press the SPACE bar to increment (or press the DEL [delete] key to decrement) the index number. 3. Press ENTER ...

  • Cabletron Systems Expansion module 6H122-08 - page 140

    Chapter 5: Local Management 5-96 6H122-08 User’ s Guide 5.29 NETW ORK T OOLS The Network T ools function resides on the 6H122-08 and allo ws the user to access and manage network de vices. Access the Network T ools screen by using the arro w ke ys to highlight the NETWORK T OOLS menu item in the Module Menu screen and pressing ENTER. The Network ...

  • Cabletron Systems Expansion module 6H122-08 - page 141

    Netw ork T ools 6H122-08 User’ s Guide 5-97 The commands are presented in the follo wing format: command: Syntax: Sho ws the required command format. It indicates where ar guments, if any , must be specified. Description: Briefly describes the command and its uses. Options: Lists any additional fields in the appropriate format that may be adde ...

  • Cabletron Systems Expansion module 6H122-08 - page 142

    Chapter 5: Local Management 5-98 6H122-08 User’ s Guide Each ARP cache entry lists the network interface that the de vice is connected to, the de vice’ s network addr ess or IP address, the de vice’ s physical addr ess or MA C address, and the media type of connection to the de vice. Media types are displayed as numbers, which stand for the f ...

  • Cabletron Systems Expansion module 6H122-08 - page 143

    Netw ork T ools 6H122-08 User’ s Guide 5-99 bridge: Syntax: bridge [EN ABLE/DISABLE] [IFNUM/ALL] Description: The bridge command allo ws each bridge port to be enabled or disabled at the user’ s request, either one at a time or all at once. Specifying a single interface number will af fect the bridging status of that interface, while specifying ...

  • Cabletron Systems Expansion module 6H122-08 - page 144

    Chapter 5: Local Management 5-100 6H122-08 User’ s Guide defr oute: Syntax: defroute [interface number] [IP address] Description: The defroute command allo ws the user to view , set or delete the default IP route to a managed de vice through the specified interface. Options: Not Applicable Example: -> defroute 2 147.152.42.32 # Default route ...

  • Cabletron Systems Expansion module 6H122-08 - page 145

    Netw ork T ools 6H122-08 User’ s Guide 5-101 netstat: Syntax: netstat [option] Description: The netstat command provides a display of general network statistics for the managed de vice. The netstat command must be used with one of the two display options. Options: -i Displays status and capability information for each interface -r Displays routin ...

  • Cabletron Systems Expansion module 6H122-08 - page 146

    Chapter 5: Local Management 5-102 6H122-08 User’ s Guide reset: Syntax: reset Description: The reset command allo ws a soft reset of the de vice. The user will be queried to confirm the reset command to insure against unwanted resets. Options: Not Applicable Example: ! CA UTION The Network T ools connection to the module will be ter minated upon ...

  • Cabletron Systems Expansion module 6H122-08 - page 147

    Netw ork T ools 6H122-08 User’ s Guide 5-103 show: Syntax: sho w [PR O TOCOL] [T ABLE] Description: The sho w command displays information concerning v arious components of the device. Protocols currently supported are IP , IPX, DECnet, and AppleT alk. Components of those protocols that are currently supported are ARP caches, route tables, FIB ta ...

  • Cabletron Systems Expansion module 6H122-08 - page 148

    Chapter 5: Local Management 5-104 6H122-08 User’ s Guide tracer oute: Syntax: traceroute [IP address] Description: The traceroute command generates a TRA CER OUTE request to a specified IP address and provides a display of all ne xt-hop routers in the path to the de vice. If the device is not reached, the command displays all next-hop routers to ...

  • Cabletron Systems Expansion module 6H122-08 - page 149

    Netw ork T ools 6H122-08 User’ s Guide 5-105 telnet: Syntax: telnet [IP address] [Port #] Description: The telnet command allo ws the user to communicate with another host (that supports T elnet connections) using the T elnet protocol. The user must specify the remote host using its IP address. The [IP address] field is mandatory . If no Port nu ...

  • Cabletron Systems Expansion module 6H122-08 - page 150

    Chapter 5: Local Management 5-106 6H122-08 User’ s Guide link_trap: Syntax: link_trap [enable/disable/status] [POR T/all] Description: The link_trap command allo ws link traps to be enabled or disabled when specifying a single port, or simultaneously when specifying “all” or no ports. When one or all ports are specified to enable, disable, o ...

  • Cabletron Systems Expansion module 6H122-08 - page 151

    6H122-08 User’ s Guide A-1 APPENDIX A SPECIFICATIONS This appendix provides operating specifications for the Cabletron Systems 6H122-08 Interface Modules. Cabletron Systems reserv es the right to change these specifications at any time without notice. A.1 DEVICE SPECIFICATIONS A.2 PH YSICAL PROPERTIES A.3 EN VIRONMENTAL REQUIREMENTS Processor: ...

  • Cabletron Systems Expansion module 6H122-08 - page 152

    Appendix A: Specifications A-2 6H122-08 User’ s Guide A.4 INPUT/OUTPUT P OR TS 6H122-08 Specifications A.5 COM P OR T PINOUT ASSIGNMENTS The COM port is a serial communications port that supports Local Management or connection to a UPS. The COM port has the follo wing pin assignments: Ports 1 through 6 Fast Ethernet 10/100 Mbps (100B ASE-TX com ...

  • Cabletron Systems Expansion module 6H122-08 - page 153

    Regulatory Compliance 6H122-08 User’ s Guide A-3 A.6 REGULATORY COMPLIANCE Safety The 6H122-08 meet the safety requirements of UL 1950, CSA C22.2 No. 950, EN 60950, IEC 950 and 73/23/EEC. Electr omagnetic Compatibility (EMC) The 6H122-08 meet the requirements of FCC Part 15, EN 50082-1, EN 55022, VCCI V -3, CSA C108.8, AS/NZS 3548 and 89/336/EEC. ...

  • Cabletron Systems Expansion module 6H122-08 - page 154

    Appendix A: Specifications A-4 6H122-08 User’ s Guide ...

  • Cabletron Systems Expansion module 6H122-08 - page 155

    6H122-08 User’ s Guide B-1 APPENDIX B FE-100TX, FE-100FX AND FE-100F3 SPECIFICATIONS The 6H122-08 supports three Fast Ethernet Interf ace Modules: • FE-100TX • FE-100FX • FE-100F3 This appendix provides the specifications for these modules. B.1 FE-100TX The FE-100TX uses an RJ45 connector supporting Category 5 Unshielded T wisted P air (UT ...

  • Cabletron Systems Expansion module 6H122-08 - page 156

    Appendix B: FE-100TX, FE-100FX and FE-100F3 Specifications B-2 6H122-08 User’ s Guide B.2 FE-100FX The FE-100FX sho wn in Figure B-2 uses an SC style connector that supports multimode fiber optic cabling. Specifications for the FE-100FX are listed belo w . Figure B-2 FE-100FX Table B-1 Transmitter Power Cable T ype W orst Case Budget T ypical ...

  • Cabletron Systems Expansion module 6H122-08 - page 157

    FE-100F3 6H122-08 User’ s Guide B-3 B.3 FE-100F3 The FE-100F3 sho wn in Figure B-3 uses an SC style connector that supports single mode fiber optic cabling. Specifications for the FE-100F3 are listed in T able B-2 belo w . Figure B-3 FE-100F3 Table B-2 Transmitter Power Cable T ype W orst Case Budget T ypical Budget 8/125 µm fiber >10.0 dB ...

  • Cabletron Systems Expansion module 6H122-08 - page 158

    Appendix B: FE-100TX, FE-100FX and FE-100F3 Specifications B-4 6H122-08 User’ s Guide ...

  • Cabletron Systems Expansion module 6H122-08 - page 159

    6H122-08 User’ s Guide C-1 APPENDIX C OPTIONAL INSTALLATIONS AND MODE SWITCH BANK SETTINGS This appendix cov ers the follo wing items: • Required tools ( Section C.1 ) • Locations, functions, and settings for the mode switches ( Section C.2 ) • Installing Optional Fast Ethernet Interf ace Modules ( Section C.3 ) C.1 REQUIRED T OOLS Y ou nee ...

  • Cabletron Systems Expansion module 6H122-08 - page 160

    Appendix C: Optional Installations and Mode Switch Bank Settings C-2 6H122-08 User’ s Guide Figure C-1 sho ws the location of the mode switches and the switch settings for normal operation. Figure C-1 6H122-08 Mode Switch Location/Component La yout Switch definitions and positions are as follo ws: • Switches 1 through 4 – For Cabletron Syste ...

  • Cabletron Systems Expansion module 6H122-08 - page 161

    Setting the Mode Switch 6H122-08 User’ s Guide C-3 • After changing the position of switch 6 and restarting the module, the 6H122-08 requests a ne w image download until the y either receiv e a ne w image or the RESET button on the front panel is pressed. When the RESET b utton is pressed, the 6H122-08 continues trying to contact a BootP server ...

  • Cabletron Systems Expansion module 6H122-08 - page 162

    Appendix C: Optional Installations and Mode Switch Bank Settings C-4 6H122-08 User’ s Guide C.3 INSTALLING OPTIONAL F AST ETHERNET INTERFACE MODULES Figure C-2 sho ws the location of the Fast Ethernet Interface Module connectors on the 6H122-08 board for port slots 7 and 8. Figure C-2 6H122-08 Fast Ethernet Interface Module Connector Location Opt ...

  • Cabletron Systems Expansion module 6H122-08 - page 163

    Installing Optional F ast Ethernet Interface Modules 6H122-08 User’ s Guide C-5 T o install a F ast Ethernet Interface Module in port slot 7 or 8 of the 6H122-08, proceed as follo ws: 1. Remove the coverplate from the port slot where the Fast Ethernet Interface Module will be installed. To remove a coverplate, refer to Figure C-3 and proceed as f ...

  • Cabletron Systems Expansion module 6H122-08 - page 164

    Appendix C: Optional Installations and Mode Switch Bank Settings C-6 6H122-08 User’ s Guide Figure C-3 Coverplate Remo val 2. Remove the screw from the rear standoff. Save the screw. 3. See Figure C-4 . Gently pull the faceplate of the 6H122-08 forward to allow room for the Fast Ethernet Interface Modules to be aligned over the connector. 4. Care ...

  • Cabletron Systems Expansion module 6H122-08 - page 165

    Installing Optional F ast Ethernet Interface Modules 6H122-08 User’ s Guide C-7 Figure C-4 Installing the Fast Ethernet Interface Module 5. Press down firmly on the Fast Ethernet Interface Module until the pins slide all the way into the motherboard connector. Ensure that the Fast Ethernet Interface Module seats flush on the standoffs. 6. Secure ...

  • Cabletron Systems Expansion module 6H122-08 - page 166

    Appendix C: Optional Installations and Mode Switch Bank Settings C-8 6H122-08 User’ s Guide ...

  • Cabletron Systems Expansion module 6H122-08 - page 167

    6H122-08 User’ s Guide Index-1 Numerics 100BASE-TX cable length 2-2 10BASE-T connection 3-5 requirements 2-1 802.1Q VLAN Configuration 5-16, 5-71 A Access policy 5-25, 5-56 B Broadcast Suppression screen 5-81, 5-82, 5-83 C Cable specifications 100BASE-FX MMF 2-2 100BASE-TX network 2-2 10BASE-T network 2-1 Chassis Configuration screen 802.1Q VLAN ...

  • Cabletron Systems Expansion module 6H122-08 - page 168

    Index Index-2 6H122-08 User’ s Guide module date 5-41 module time 5-41, 5-47, 5-48 Module Uptime 5-42 Operational Mode 5-42, 5-49 screen lock-out time 5-42, 5-49 screen refresh time 5-41, 5-48 subnet mask 5-20, 5-41, 5-45 TFTP Gateway IP Addr 5-46 H Help related manuals 1-12 I Installation Fast Ethernet Interface Module C-4 Interface Statistics s ...

  • Cabletron Systems Expansion module 6H122-08 - page 169

    Index 6H122-08 User’ s Guide Index-3 R RESET button 4-7 RMON Statistics screen 5-91, 5-95 S Safety A-3 Screen lock-out time 5-19, 5-22, 5-42, 5-49 Screen refresh time 5-22, 5-48 Screens Broadcast Suppression screen 5-81 Chassis Environmental Screen 5-29 Chassis Menu screen 5-15 Device Menu screen 5-36 Flash Download screen 5-74 General Configurat ...

  • Cabletron Systems Expansion module 6H122-08 - page 170

    Index Index-4 6H122-08 User’ s Guide ...

Fabricante Cabletron Systems Categoría Switch

Los documentos del dispositivo Cabletron Systems Expansion module 6H122-08 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Cabletron Systems
- manuales de instrucciones Expansion module 6H122-08
- hojas de producto Cabletron Systems
- folletos informativos
- o etiquetas energéticas Cabletron Systems Expansion module 6H122-08
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Cabletron Systems Expansion module 6H122-08.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Cabletron Systems Expansion module 6H122-08, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Cabletron Systems Expansion module 6H122-08. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Cabletron Systems Expansion module 6H122-08.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Cabletron Systems Expansion module 6H122-08, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Cabletron Systems Expansion module 6H122-08. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Cabletron Systems Expansion module 6H122-08.

El manual de instrucciones completo de Cabletron Systems debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Cabletron Systems Expansion module 6H122-08 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Cabletron Systems Expansion module 6H122-08, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Cabletron Systems Expansion module 6H122-08 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Cabletron Systems Expansion module 6H122-08 - que deben facilitarnos los primeros pasos durante el uso de Cabletron Systems Expansion module 6H122-08
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Cabletron Systems Expansion module 6H122-08
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Cabletron Systems Expansion module 6H122-08 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Cabletron Systems Expansion module 6H122-08?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Cabletron Systems Expansion module 6H122-08, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Cabletron Systems Expansion module 6H122-08 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)