    1 INSTALLATION INSTRUCTIONS APPLICA TION MANUAL AND INST ALLA TION INSTRUCTIONS THIS UNIT IS DESIGNED FOR OEM INSTALLATION ALL INITIAL INSTALLATIONS MUST BE APPROVED BY THE SALES DEPT. ROT AR Y COMPRESSOR SYSTEM MODELS Air Conditioners 39626.501 & 39626.506 Heat Pump s 39726.501 & 39726.506 SYSTEM MODELS SELF-CONT AINED AIR CONDITIONER & ...

  • Dometic 39726.501 - page 2

    INSTALLATION INSTRUCTIONS 2 TABLE OF CONTENTS: 1.0 SAFETY INSTRUCTIONS ........................................................................... PAGE 3 2.0 APPLICATION MANUAL ............................................................................. PAGE 4 2.1 AIR DISTRIBUTION ................................................................... ...

  • Dometic 39726.501 - page 3

    3 INSTALLATION INSTRUCTIONS 1.0 SAFETY INSTRUCTIONS This manual has safety information and instruc- tions to help users eliminate or reduce the risk of accidents and injuries. RECOGNIZE SAFETY INFORMA TION This is the safety-alert symbol. When you see this symbol in this manual, be alert to the potential for personal injury . Follow recommended pre ...

  • Dometic 39726.501 - page 4

    INSTALLATION INSTRUCTIONS 4 2.1 AIR DISTRIBUTION 2.1.1 GENERAL INFORMATION The purpose of an air conditioning system is to provide environmental conditions in a space to keep its occupants comfortable. The basic elements of a simple forced circulation air system consists of a cooling unit, a centrifugal blower, a temperature sensing device controll ...

  • Dometic 39726.501 - page 5

    5 INSTALLATION INSTRUCTIONS 2.1.5 AIR FLOW AND FRICTION Air flows in a duct system from a region of high pressure to a region of lower pressure. The blower creates the pressure differential which causes the air flow through the duct system. The point of highest pressure in the system is at the outlet of the blower. The point of lowest pressure in t ...

  • Dometic 39726.501 - page 6

    INSTALLATION INSTRUCTIONS 6 ITEM 1 Sharp Angle ITEM 4 Long Radius Bend ITEM 2 Rounded Outer Corner ITEM 5 Splitters, or turning vanes installed in sharp angle bend ITEM 3 Rounded Corners ITEM 6 Splitters in rounded corner bend EDDIES EDDIES ABRUPT EXPAN- SION SMALL DUCT EDDY LOSSES LARGE DUCT FIG. 2.9 Abrupt expansion results in excessive pressure ...

  • Dometic 39726.501 - page 7

    7 INSTALLATION INSTRUCTIONS 4. Sudden contractions in air stream 5. Sudden expansions in air stream 2.1.7 REGISTERS, DIFFUSERS, AND GRILLE SELEC- TION One of the most important considerations in designing a conditioning system is the selection of the registers, diffus- ers and grills. Even though a system delivers the required amount of conditioned ...

  • Dometic 39726.501 - page 8

    INSTALLATION INSTRUCTIONS 8 It is the responsibility of the installer to en- sure the duct work will not collapse or bend during and after installation. Dometic Corpo- ration will not be liable for any structural dam- age due to improperly insulated, sealed or collapsed duct work. CAUTION Dometic Corporation will not be held liable for roof structu ...

  • Dometic 39726.501 - page 9

    9 INSTALLATION INSTRUCTIONS 2.5.0 MOUNTING IN COACH The dual basement air conditioner and heat pump are designed for under the floor installation. It is the vehicle manufacturer's responsibility to provide an installation space which will allow for cutouts and mounting of the unit without cutting vital frame structures. The frame and structura ...

  • Dometic 39726.501 - page 10

    INSTALLATION INSTRUCTIONS 10 System Model 39726.501 & 39726.506* Nominal BTU Capacity 26,000 Volts/Phase/Hertz (each circuit) 115 AC / 1 / 60 Run Amps Comp (Circuit 1 =10.0) (Circuit 2 = 9.8) LRA Compressor (Circuit 1 = 59.0) (Circuit 2 = 59.0) Total Blwr/Fan Motor Run Amps 8.5 (Circuit 1) Total Blwr/Fan Motor LRA Amps 18.0 (Circuit 1) Duct Sta ...

  • Dometic 39726.501 - page 11

    11 INSTALLATION INSTRUCTIONS C HERM HERM C 3108345.061 FIELD WIRING FIELD WIRING FACTORY WIRING FACTORY WIRING P4 P3 P5 NC P6 COM K6 COM NO K1 F1 P1 P2 NO T3 NC T1 3 AMP FUSE 3 AMP FUSE CIRCUIT CIRCUIT MOTOR COND. BLOWER COND. BLOWER EVAP . BLOWER EVAP . BLOWER MOTOR COMPRESSOR R C S OL COMPRESSOR S C OL R = WIRE NUT = WIRE NUT ELEC. BOX BLKHD SENS ...

  • Dometic 39726.501 - page 12

    INSTALLATION INSTRUCTIONS 12 3.1 GENERAL INFORMATION 3.1.1 THIS UNIT IS DESIGNED FOR: A. Installation in a recreational vehicle at the time the vehicle is manufactured. B. Heating operation in a MILD GEOGRAPHICAL AREA where the heat loss is minimal. C. Turning "OFF" the heat pump and switching to furnace (aux. heat) when the outside tempe ...

  • Dometic 39726.501 - page 13

    13 INSTALLATION INSTRUCTIONS Where the return air must be provided through louvers or mesh screen, the FREE AREA percentage of the material used shall be taken into consideration when making this determination. An example of how to determine FREE AREA is included in "3.2.2. Outside Coil". B . Grills (See FIG. 3.4) Note: The return air gri ...

  • Dometic 39726.501 - page 14

    INSTALLATION INSTRUCTIONS 14 3.3 ELECTRICAL WIRING E. Circuit #2 should be wired through the on-board generator or a separate power cord dedicated to Circuit #2. Note: A standard 30 amp hookup will not power both Circuit 1 and Circuit 2 and the coach's other major appliances. 3.3.2 SUPPLY WIRE CONNECTION A. Connect main power supply Cir. #1 to ...

  • Dometic 39726.501 - page 15

    15 INSTALLATION INSTRUCTIONS B. Route a dedicated DC supply line (18-22 AWG copper conductors) from the Converter or Battery to the unit's electrical box. Connect with wire nuts positive (+) DC to the red wire; Negative (-) DC to the black wire. C. Route thermostat wires from the furnace (if applicable) to the electrical box and attached them ...

  • Dometic 39726.501 - page 16

    INSTALLATION INSTRUCTIONS 16 6. If an Energy Management System - EMS (load shed) is to be used with the control, two wires must be routed to the electrical control box. The signal required for this function is a normally open relay contact. When the EMS calls for the com- pressor to shut off, the relay contacts should close. Make sure that at least ...

Fabricante Dometic Categoría Air Conditioner

Los documentos del dispositivo Dometic 39726.501 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Dometic
- manuales de instrucciones 39726.501
- hojas de producto Dometic
- folletos informativos
- o etiquetas energéticas Dometic 39726.501
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Dometic 39726.501.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Dometic 39726.501, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Dometic 39726.501. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Dometic 39726.501.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Dometic 39726.501, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Dometic 39726.501. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Dometic 39726.501.

El manual de instrucciones completo de Dometic debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Dometic 39726.501 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Dometic 39726.501, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Dometic 39726.501 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Dometic 39726.501 - que deben facilitarnos los primeros pasos durante el uso de Dometic 39726.501
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Dometic 39726.501
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Dometic 39726.501 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Dometic 39726.501?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Dometic 39726.501, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Dometic 39726.501 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)