    FIREPLACE INSER T & FREEST ANDING MODEL 81 NON-CA T AL YTIC UNIT Buck Stove FEATURES PREPARATIONS INSTALLATION OPERATION MAINTENANCE SAFETY SAFETY NOTICE IF THIS HEATER IS NOT PROPERLY INSTALLED, A H OUSE FIRE MAY RESULT. FOR YOUR SAFE TY, FOLLOW THE INSTALLA TION INSTRUCTIONS. CONTACT THE AUTHORIT Y HAVING JURISDICTION (SUCH AS MUNICIPAL BUILD ...

  • New Buck Corporation 81 - page 2

    ...

  • New Buck Corporation 81 - page 3

    T ABLE OF CONTENTS Wood Stove Description ........................................................................................................ ....... 2 Important Instructions ........................................................................................................ ........... 3 SECTION I: Introduction ........................... ...

  • New Buck Corporation 81 - page 4

    EP A COMPLIANCE ST A TUS The Model 81 heater meets U.S. Environmental Protection A gency’s Emission limits for wood heaters sold after July 1, 1992. U nder specific conditions this heater has been shown to deliver heat at rates ranging from approximately 10,000 to 45,000 BTU/hr for the Model 81. MODEL 81 WOOD ST OVE 1. Secondary air tubes 2. Blow ...

  • New Buck Corporation 81 - page 5

    INST ALLA TION, OPERA TION, AND MAINTENANCE INSTRUCTIONS MODEL 81 READ THIS FIRST IMPOR T ANT INSTRUCTIONS W ARNING THESE UNITS GENERATE A LOT OF HEAT , SO TREAT THEM WITH CARE. HOT WHILE IN OPERATION . KEEP CHILDREN, CLOTHI NG AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS. READ AL L INSTRUCTIONS BEFORE INSTALLING AND USING THE APPLIANCE. FAILUR ...

  • New Buck Corporation 81 - page 6

    CAUTION YOUR CHIMNEY MUST BE CORRECTL Y SIZED . A CHIMNEY THAT IS TOO SMALL OR LARGE IN DIAMETER OR TOO SHORT, CAN CAUSE YOUR ST OVE TO SPILL SMOKE WHEN THE DOOR IS OPENED. SECTION I INTRODUCTION Your Buck Stove is non-catalytic unit designed to meet the most stringent emissions stand ards without the use of a catalytic combustor. This effect is ac ...

  • New Buck Corporation 81 - page 7

    SECTION II MASONR Y INSER T INST ALLA TION The Model 81 may be installed using an all mas onry fireplace built in accordance with the Uniform Building Code and National Fire Prot ection Association (NFPA). The first step in this type of installation is to determine acceptability of fire place and chim ney for use with a woodstove. Both construction ...

  • New Buck Corporation 81 - page 8

    MINIMUM CLEARANCES Floor Protection: When installing freestanding heater , a floor protector must be us e. Floor protection m ust be 3/8” minimum thickness non-combustib le material or equivalent. How to use alternate materials and how to ca lculate equivalent thickn ess An easy means of determining if a proposed altern ate floor protector meet s ...

  • New Buck Corporation 81 - page 9

    POSSIBLE TOOLS NEEDED FOR INST ALLA TION If you decide to install your own stove, there are several hand tools you may need to do the job. If you do not already have them, they are r eadily available at mo st hardware stores. Caulking gun Large adjustable wrench (may not be needed) Drop cloths or newspapers Vacuum cleaner or whisk broom Flashlight ...

  • New Buck Corporation 81 - page 10

    OPTION (B) REMOVE DAMPER OR WIRE IT OPEN AIRTIGHT INSULATED CLEAN- OUT BLOCK-OFF PLATE OR DAMPER ADAPTER SEAL TRIM PANELS WITH INSULATION OR HIGH TEMPERATURE CAULK STAINLESS STEEL CHIMNEY CONNEC- TOR MUST EXTEND 1’ PAST THE BLOCK-OFF PLATE OR TO THE FLUE LINER NOTE: Follow installation instruction with Direct Connection Kit. (Kit sold separately) ...

  • New Buck Corporation 81 - page 11

    INST ALLA TION PROCEDURE (Use a chimney connector or a Listed Direct or Positive Connect) (See Pag e 8.) POSITIONING HEATER When position ing heater, the following conditions MUST be met! (See Figure 2). 1. The front of damper openi ng must be positioned BEHIND rear edge of lintel to ensur e proper dr aft. (See Figure 2). 2. Center hea ter in the f ...

  • New Buck Corporation 81 - page 12

    NOTE: Mount top trim panel so that it sits in front of top of side trim panels. 9. Obtain brass trim kit provided wi th insert kit and sli p over top a nd sides of trim panels. Top ends of brass may need to be trimmed to fit (See Figure 4). 10. Using insulation provided, pe el and stick to back of pa nels overlapping fireplace dimens ions by 1" ...

  • New Buck Corporation 81 - page 13

    CAUTION THE UNIT IS PAINTED WITH A SPECIALLY FORMULATED HIGH TEMPERATURE PAINT THAT CURES DURING THE FIRST TWO OR THREE FIRINGS. YOU MAY NOTICE A SLI GHT SMOKING EFFECT AND AN ODOR OF BURNING PAINT WHEN YOU BUILD THE FI RST FIRES. THIS IS NORMAL AND IS NOT A CAUSE FOR ALARM. IN SOME CASES, THESE FUMES WILL ACTIVATE A SMOKE ALARM . OPEN ING A WINDOW ...

  • New Buck Corporation 81 - page 14

    SECTION III PRE-F AB INSER T INST ALLA TION The Model 81 may be installed into any UL listed pre-fabricated firepla ce that is large enough to accept it. NOTE: When installing Model 81 into a Pre-Fab Zero-Clearance fireplace, a UL-1777 LINER must be installed the Full Length of chim ney and attached to flue exit of insert. NOTE: The ash lip, smoke ...

  • New Buck Corporation 81 - page 15

    Page 13 SECTION IV RESIDENTIAL FREEST ANDING INST ALLA TION Select an installation location t hat will give best air flow from front of heater to remainder of home. PREP ARING STOVE FOR INST ALLA TION 1. Inspect unit for any obvious physical damage. 2. Plug power cord into a 115V AC outlet to test mo tor and fan. Do not run cord under unit or in hi ...

  • New Buck Corporation 81 - page 16

    AL TERNA TE FLOOR PROTECT ORS MA TERIAL Floor Protection: When installing freestanding heater , a floor protector must be us e. Floor protection m ust be 3/8” minimum thickness non-combustib le material or equivalent. How to use alternate materials and how to ca lculate equivalent thickn ess An easy means of determining if a proposed altern ate f ...

  • New Buck Corporation 81 - page 17

    Chimney This model is designed for connection to an y listed 2100º UL103 HT chimneys and parts. Follow chimneys manufacturer's instructions carefully. NOTE: This Room Heater must be converted to (1) a chimney com plying with requirements for Type HT chimneys in Standard forchimn eys, Factory-Built, Re sidential, Type and Building Heating Appl ...

  • New Buck Corporation 81 - page 18

    three (3) sheet metal screws or rivets. Ne xt, install an optional New Buck Corporation chimney connector to flue ex it of heater. (See Figure 6). 4. Install Single Wall Connector and chimney sy stem per m anufacturer’s written operating in- structions. See manufact urer’s list of tested pip es in this manual. Figure 6 Figure 7 B. Wall Exit Int ...

  • New Buck Corporation 81 - page 19

    maintaining clearances to ceiling as noted in Figu re 7. This will giv e you center of hole for chimney penetration. 4. After locating center of pe netration, install tee box and chimney as per chimney manufacturer's specifications. 5. Connect chimney collar to tee-box using #24 ga . minimum blued or black steel connector pipe. (DO NOT USE GAL ...

  • New Buck Corporation 81 - page 20

    NOTE: In addition, a connector to a masonry chimney shall extend through wall to inner face or liner but not beyond and shall be firmly cem ented to masonry. EXCEPTION: A thimble may be used to facilitate rem oval of chimney connector for cleaning, in which case, thimble shall be perm anently cemen ted in place with high-tem perature cement. 2. Onc ...

  • New Buck Corporation 81 - page 21

    OPTIONA L Figure 8 Close Clearance Installation using: (1) 6" Simpson Dura-Vent single wall chim ney connector Dura Black and 6" Simpson Dura-Vent 2100 Deg Ht. “Type DP” chimney. (2) 6" Metal Fab Type single wall connector- 6" Metal Fab 2100 HT chimney. (3) 6” Ameritec single wall connector - 6” Ameritec 2100 degree HT c ...

  • New Buck Corporation 81 - page 22

    FINAL CHECK 1. Recheck specified clearances. 2. Remove all foreign material from firebox area. 3. Open primary air draft. NOTE: Plug power cord into a 115V AC outlet. Set switch to “Manual” and rheostat to “High” position to ensure motor operates proper ly. Route cord to prevent dam age to cord insulation from heat and sharp objects. Keep c ...

  • New Buck Corporation 81 - page 23

    CLEARANCES FOR MODEL 81 MINIMUM CLEARANCES TO COMBUSTIBLES FREEST ANDING Figure 9 A B C D E F G MODEL 81 23" 23" 25" 16" 16” 8” 8” NOTE: All clearances are to combustibles witho ut low clearance shields and using single wall pipe and minimum floor protector. Clearances above may be reduced. Follow NFPA-211 codes if availab ...

  • New Buck Corporation 81 - page 24

    CLEARANCES FOR MODEL 81 MINIMUM CLEARANCES TO COMBUSTIBLES SINGLE W ALL CHIMNEY CONNECTOR AND OPTIONAL SHIELDS, MOBILE HOME AND ALCOVE INST ALLA TIONS Figure 10 A B C D E F G MODEL 81 12" 16" 12.5" 12" 16’ 8” 8” NOTE: All clearances are to combustibles using single wall pipe and all low clearance shields and minimum floor ...

  • New Buck Corporation 81 - page 25

    INST ALLA TION OF (OPTIONAL) CLOSE CLEARANCE SHIELDS 1. Center rear close clearance shield with back of stove. Mark rear of stove, using reference holes in rear shield. Using self-tapp ing screws , drill four holes in lo cations marked. Remove screws and attach rear shield to back of stove. (See figure 11a). 2. Insert front end of side shield behin ...

  • New Buck Corporation 81 - page 26

    Page 24 SECTION V FREEST ANDING MOBILE HOME INST ALLA TION FOR MINIMUM CLEARANCES SEE P AGE 21. Floor Protection: When installing freestanding heater , a floor protector must be us e. Floor protection m ust be 3/8” minimum thickness non-combustib le material or equivalent. How to use alternate materials and how to ca lculate equivalent thickn ess ...

  • New Buck Corporation 81 - page 27

    Page 25 T OOLS FOR INST ALLA TION Drop cloth, 3/32" Metal drill bit, 5/16" magnetic socket chuck adapter, 5/ 16" wrench (box or so cket) or adjustable wrench, Jigsaw with masonry, metal and wood blades WARNING: DO NOT INSTALL IN A SLEEPING ROOM PREP ARING STOVE FOR INST ALLA TION 1. Remove protective plastic wrapping from unit, inspe ...

  • New Buck Corporation 81 - page 28

    3. Place unit on pad m aking sure minimumum clearance specifications are met. For minimum clearance to combustibles (See Page 22). 4. Lightly mark with a pencil loca tion of pedestal on protective pad. 5. Next, remove four (4) screws holding heat er to stand. Position h eater out of way of installation area. 6. Check that pedestal stand is still al ...

  • New Buck Corporation 81 - page 29

    Ceiling Exit (Using Close Clearance Listed Chimney) 1. Suspend a plumb bob from ceiling above unit so th at weig ht is hanging in center of flue exit. (A small weight on a stri ng will serve as a plumb bob). Mark ceiling where string is suspended to locate center of chimney hole. 2. After locating center of hole, install ceiling support box, chimne ...

  • New Buck Corporation 81 - page 30

    (a) Chimney pipe is 3' higher than r oof at point where it penetrates roof. (b) Chimney pipe height is at least 2' higher than any part of roof within 10' of chimney. (See Page 27, Figure 12). 4. Next, install a New Buck Corporation chimney connector to flue of heater or use 3 “Ell” brackets and secure to to p of heater and pipe. ...

  • New Buck Corporation 81 - page 31

    4. Place crumpled p ieces of newspaper in stove. Light it and close door. Ensure that stove draws properly through primary draft. 5. Check for smoke leaks around door. 6. Open door and check for smoke escaping from front of stove. Smoki ng usually indicates a defective or poorly positioned chimney. Som e chi mneys with a marginal draft can be prehe ...

  • New Buck Corporation 81 - page 32

    The chimney and chimney connector should be in spected once every two months. Any build- up of soot should be removed to prevent risk of a chimney fire. To rem o ve chimney or chimney connector: Remove screws or fasteners. Rem ove pipe and clean with steel brush. Replace chimney or chimney connector and re place screws and/or fasteners. CAUTION NEV ...

  • New Buck Corporation 81 - page 33

    BUILDING A FIRE 1. Open door. 2. Open primary air control loca ted on right side of stove unde r hearth. (See Page 25, Figure 14). To close, push all the wa y in. To open, pull all the wa y out. Adjustments to airflow may be made by positioning ha ndle anywhere in between. 3. Twist two pieces of non-colored newspaper into a roll and place them on f ...

  • New Buck Corporation 81 - page 34

    ROOM AIR BLOWER OPERA TION Your heater is equipped with a room air blower. For operati on and wiring (See Figure 14). For your convenience, your heater is equipped with a rheostat with which you are able to select the air flow. The auto and manual switch will allow you to select the position at which thermostat will function. Auto-position: After h ...

  • New Buck Corporation 81 - page 35

    SECTION VIII TROUBLESHOOTING PROBLEM 1. Sluggish heater 2. High Fuel Consumption 3. Back puffing 4. Smoke rollout when heater door is opened POSSIBLE CAUSE 1. Obstruction in chimney 2. Improperly sealed trim kit or direct connect kit 3. Wet or unseasoned wood being burned. 4. Poor chimney draft 1. Improper regulation of draft or inlet air 2. Improp ...

  • New Buck Corporation 81 - page 36

    REPLACEMENT P AR TS FOR THE MODEL 81 1. Air Control Bar MF 810084 2. Door Handle Assembly PA 910096 3. Door Latch PC 910098 4. Door Handle Washer PO 91WASH 5. Front door bushing PO 910102 6. Door Gold PC 212400G 7. Door Black PC 212400 8. Off/Auto/Man Fan Switch PE RC211RB 9. Thermostat 110 disc PE 400132 10. Power Cord PE 400240 11. Strain Relief ...

  • New Buck Corporation 81 - page 37

    NEW BUCK CORPORA TION (NBC) "LIMITED W ARRANTY" FOR THE BUCK STOVE PLEASE READ THIS W ARRANTY CAREFULL Y PRODUCTS COVERED This warranty covers the new Buck Stove h eating unit, so long as it is owned by the original purchaser, including optional and standard accessori es purchased at the sa me tim e, subject to terms, limitations, and con ...

  • New Buck Corporation 81 - page 38

    ...

  • New Buck Corporation 81 - page 39

    If for any reason you are dissatisfied with the suggested procedures, you may contact us in writing at: New Buck Corporation Customer Service Department P. O. Box 69 Spruce Pine, NC 28777 CONDITIONS AND EXCLUSIONS (A) Replacement of parts may be in the form of new or fully reconditioned parts, at NBC's option. (B) There is no other express wa ...

Fabricante New Buck Corporation Categoría Home Security System

Los documentos del dispositivo New Buck Corporation 81 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos New Buck Corporation
- manuales de instrucciones 81
- hojas de producto New Buck Corporation
- folletos informativos
- o etiquetas energéticas New Buck Corporation 81
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones New Buck Corporation 81.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje New Buck Corporation 81, instrucciones de servicio, instrucciones cortas o instrucciones de usuario New Buck Corporation 81. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto New Buck Corporation 81.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo New Buck Corporation 81, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar New Buck Corporation 81. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de New Buck Corporation 81.

El manual de instrucciones completo de New Buck Corporation debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual New Buck Corporation 81 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice New Buck Corporation 81, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de New Buck Corporation 81 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo New Buck Corporation 81 - que deben facilitarnos los primeros pasos durante el uso de New Buck Corporation 81
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con New Buck Corporation 81
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de New Buck Corporation 81 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de New Buck Corporation 81?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con New Buck Corporation 81, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con New Buck Corporation 81 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)