Manual de instrucciones Maretron Run Indicator Module RIM100

17 de páginas 0.47 mb
Descargar

Pasar a la página of 17

Summary
  • Maretron Run Indicator Module RIM100 - page 1

    Revision 1.0 Page i ® ® RIM100 Run Indicator Module User’s Manual Revision 1.0 Copyright © 2008 Maretron, LLP All Rights Reserved Maretron, LLP 9014 N. 23 rd Ave #10 Phoenix, AZ 85021-7850 http://www.maretron.com Maretron Manual Part #: M002001 ...

  • Maretron Run Indicator Module RIM100 - page 2

    RIM100 User's Manual Page ii Revision 1.0 Revision History Revision Description 1.0 Original document ...

  • Maretron Run Indicator Module RIM100 - page 3

    Revision 1.0 Page iii ® ® Table of Contents 1  Introduc tion .................................................................................................................. ......... 1  1.1  Firmware Revi sion .................................................................................................... 1  1.2  RIM100 Feat ...

  • Maretron Run Indicator Module RIM100 - page 4

    ...

  • Maretron Run Indicator Module RIM100 - page 5

    Revision 1.0 Page 1 ® ® 1 Introduction Congratulations on your purchase of the Maretron Run Indicator Module (RIM100). Maretron has designed and built your RIM100 to the hi ghest standards for years of dependable and accurate service. Maretron’s RIM100 monitors both AC and DC electr ical circuits and reports, over an NMEA 2000 ® network, wheth ...

  • Maretron Run Indicator Module RIM100 - page 6

    RIM100 User's Manual Page 2 Revision 1.0 3. Mount the RIM100 (Section 2.3 ) 4. Connect the RIM100 (Section 2.4 ) 5. Configure the RIM100 (Section 2.5 ) 2 Installation 2.1 Unpacking the Box When unpacking the box containing the Maretron RIM100, you shoul d find the following items: 1 – RIM100 – Run Indicator Module 1 – Parts Bag containin ...

  • Maretron Run Indicator Module RIM100 - page 7

    Revision 1.0 Page 3 ® ® 2.3 Mounting the RIM100 Attach the RIM100 securely to the vessel usi ng the included stainle ss steel mounting screws or other fasteners as shown in Figure 1 below . Figure 1 – Mounting the RIM100 2.4 Connecting the RIM100 The RIM100 requires two types of elec trical connections: 1) the NMEA 2000 ® connection (refer to ...

  • Maretron Run Indicator Module RIM100 - page 8

    RIM100 User's Manual Figure 2 – NMEA 2000 ® Connector Face Views 2.4.2 Monitored Load Connections The RIM100 monitored load connections are made by connecting to the 12-pin terminal strip on the top of the unit. First, remove the four screws at the co rners of the unit detaching the splash guard from the unit. On the bottom of the splash gu ...

  • Maretron Run Indicator Module RIM100 - page 9

    ® ® WARNING: The voltages present on AC circui ts can cause electrocution. Before making any electrical connections to the RIM100, ensure that power is removed from all AC circuits that will be connected to the RIM100. Only restore AC power after all connections have been made to the RIM100 and the splash guard has been re-installed. WARNING: Use ...

  • Maretron Run Indicator Module RIM100 - page 10

    RIM100 User's Manual Power Switch RIM100 Screw Terminals Monitored DC Load + To DC - Breaker Panel Fuse Fuse User-Supplied Components 1 2 5 4 3 6 7 8 9 10 11 12 V1+ V2- V2+ V1- V3+ V3- V4+ V4- V5+ V5- V6+ V6- Figure 4 – DC Load Connection Diagram 2.4.3 Checking Connections Once the NMEA 2000 ® connection and load connecti on(s) to the RI M1 ...

  • Maretron Run Indicator Module RIM100 - page 11

    Revision 1.0 Page 7 ® ® 2.5.2 Channel #1 - #6 Mode You must configure the RIM100 as to whether a particular ch annel should be enabled. The allowable values for this parameter are as follows: • “Enable” (default) – Use this value if t he channel is being used to monitor a load. • “Disable” – Use this value if no load circuit is co ...

  • Maretron Run Indicator Module RIM100 - page 12

    RIM100 User's Manual Page 8 Revision 1.0 • Check the security of the c able connected to the NMEA 2000 ® co nnector, and tighten if necessary. • Check the security of all of the load connections on t he top of the unit and tighten if necessary. 4 Troubleshooting If you notice unexpected operation of the Mare tron RIM100, follow the troubl ...

  • Maretron Run Indicator Module RIM100 - page 13

    Revision 1.0 Page 9 ® ® 5 Technical Specifications As Maretron is constantly impr oving its products, all specificat ions are subject to change without notice. Maretron products are designed to be accurate and reliable; however , they should be used only as aids to navigation and not as a replacem ent for tradition al navigation aids and techniqu ...

  • Maretron Run Indicator Module RIM100 - page 14

    RIM100 User's Manual Page 10 Revision 1.0 Environmental Parameter Value IEC 60945 Classification Exposed Degree of Protection IP64 Operating Temperature -25°C to 55°C Storage Temperature -40°C to 70°C Relative Humidity 93%RH @40° per IEC60945-8.2 Vibration 2-13.2Hz @ ±1mm, 13.2- 100Hz @ 7m/s 2 per IEC 60945-8.7 Solar Radiation Ultraviole ...

  • Maretron Run Indicator Module RIM100 - page 15

    ® ® 7 Installation Template Please check the dimensions before using the fo llowing diagram as a template for drilling the mounting holes because the printing proc ess may have distorted the dimensions. Figure 5 – Mounting Surface Template Revision 1.0 Page 11 ...

  • Maretron Run Indicator Module RIM100 - page 16

    RIM100 User's Manual Page 12 Revision 1.0 8 Maretron (2 Year) Limited Warranty Maretron warrants the RI M100 to be free from defects in m aterials and workm anship for t wo (2) years from the date of original purchase. If within the applicable per iod any such products sh all be proved to Maretron’s satisfaction to fail to meet the above lim ...

  • Maretron Run Indicator Module RIM100 - page 17

    Revision 1.0 Appendix A – NMEA 2000 Interfacing Page A1 ® ® Appendix A – NMEA 2000 ® Interfacing RIM100 NMEA 2000 ® Periodic Data Transmitted PGNs PGN 127501 – Binary Switch Bank Status The RIM100 uses this PGN to transmit the stat e of each of the connected switch inputs Field 1: Indicator Bank Instance – This field id entifies the par ...

Fabricante Maretron Categoría Network Card

Los documentos del dispositivo Maretron Run Indicator Module RIM100 que obtenemos del fabricante se pueden dividir en varios grupos. Entre ellos están::
- dibujos técnicos Maretron
- manuales de instrucciones Run Indicator Module RIM100
- hojas de producto Maretron
- folletos informativos
- o etiquetas energéticas Maretron Run Indicator Module RIM100
Todos son importantes, pero lo más importante desde el punto de vista del usuario de un dispositivo lo encontraremos en el manual de instrucciones Maretron Run Indicator Module RIM100.

Un conjunto de documentos determinado como manual de instrucciones se divide también en tipos más detallados, tales como: instrucciones de montaje Maretron Run Indicator Module RIM100, instrucciones de servicio, instrucciones cortas o instrucciones de usuario Maretron Run Indicator Module RIM100. Dependiendo de la situación debes buscar el documento que necesitas. En nuestra página puedes consultar el manual de instrucciones más popular del producto Maretron Run Indicator Module RIM100.

Manuales de instrucciones parecidos

El manual de instrucciones del dispositivo Maretron Run Indicator Module RIM100, ¿cómo debería ser?
El manual de instrucciones, también determinado como el manual de usuario o simplemente instrucciones, es un documento técnico que tiene como objetivo ayudar a los usuarios a utilizar Maretron Run Indicator Module RIM100. Las instrucciones normalmente las realiza un escritor técnico pero en un lenguaje comprensible para todos los usuarios de Maretron Run Indicator Module RIM100.

El manual de instrucciones completo de Maretron debe contener unos elementos básicos. Una parte de ellos es menos importante, como por ejemplo: la portada / la página principal o las páginas de autor. Sin embargo, lo demás debe facilitarnos la información más importante desde el punto de vista del usuario.

1. Introducción y pistas sobre cómo orientarse con el manual Maretron Run Indicator Module RIM100 - Al principio de cada manual se deben encontrar las indicaciones acerca de la manera de usar un manual de instrucciones. Debe contener información sobre dónde encontrar el índice Maretron Run Indicator Module RIM100, preguntas frecuentes o problemas más comunes – son los apartados más buscados por los usuarios de cada manual de instrucciones.
2. Índice - listados de todos los consejos acerca de Maretron Run Indicator Module RIM100 que encontraremos en el documento
3. Consejos de uso de las funciones básicas del dispositivo Maretron Run Indicator Module RIM100 - que deben facilitarnos los primeros pasos durante el uso de Maretron Run Indicator Module RIM100
4. Troubleshooting - una secuencia sistematizada de acciones que nos ayudará a diagnosticar los problemas más importantes con Maretron Run Indicator Module RIM100
5. FAQ - las preguntas frecuentes
6. Datos de contacto Información acerca de cómo encontrar los datos de contacto del fabricante / servicio de Maretron Run Indicator Module RIM100 en cada país si no somos capaces de solucionar el problema por nuestra cuenta.

¿Tienes una pregunta acerca de Maretron Run Indicator Module RIM100?

Utiliza el formulario que se encuentra abajo

Si con la ayuda del manual de instrucciones encontrado no has podido solucionar tu problema con Maretron Run Indicator Module RIM100, haz una pregunta utilizando el formulario que se encuentra abajo. Si alguno de los usuarios ha tenido un problema parecido con Maretron Run Indicator Module RIM100 probablemente compartirá una forma de solucionarlo.

Copia el texto de la imagen

Comentarios (0)