-
American Water Heater BCG3 - page 1
COMMERCIAL GAS W A TER HEA TERS Instruction Manual PRINTED 061 2 318819-002 PLACE THESE INSTRUCTIONS ADJACENT TO HEA TER AND NOTIFY OWNER T O KEEP FOR FUTURE REFERENCE. ? ...
-
American Water Heater BCG3 - page 2
2 17 ? ...
-
American Water Heater BCG3 - page 3
3 SAFE INST ALLA TION, USE AND SERVICE ? ...
-
American Water Heater BCG3 - page 4
4 GENERAL SAFETY INFORMA TION Fire Hazard Do not install water heater on carpeted floo r. Do not operate water heater if flood damaged. For continued protection against risk of fire: Fire or Explosion Hazard Read instruction manual before installing, using or servicing water heater . Av oid all ignition sources if you smell gas. Do not store or use ...
-
American Water Heater BCG3 - page 5
5 PRECAUTIONS ...
-
American Water Heater BCG3 - page 6
6 ? ...
-
American Water Heater BCG3 - page 7
7 THE ELIMINA TOR (SELF-CLEANING SYSTEM) ? ...
-
American Water Heater BCG3 - page 8
8 ROUGH IN DIMENSIONS RECOVER Y CAP ACITIES GAS AND ELECTRICAL CHARACTERISTICS FRONT VIEW TOP VIEW BACK VIEW F TOP OUTLET 1 1/2” NPT TOP INLET 1 1/2” NPT T ABLE 1. ROUGH-IN-DIMENSIONS ? ...
-
American Water Heater BCG3 - page 9
9 ...
-
American Water Heater BCG3 - page 10
10 INSULA TION BLANKET Do not obstruct water heater air intake with insulating blanket. Gas and carbon monoxide detectors are available. Install water heater in accordance with the instruction manual. Breathing carbon monoxide can cause brain damage or death. Always read and understand instruction manual. Breathing Hazard - Carbon Monoxide Gas ? ...
-
American Water Heater BCG3 - page 11
11 Breathing Hazard - Carbon Monoxide Gas Breathing carbon monoxide can cause brain damage or death. Always read and understand instruction manual. Under no circumstances should the input exceed the rate shown on the water heater ’s rating label. Overfiring could result in damage to the water heater and sooting. Gas and carbon monoxide detectors ...
-
American Water Heater BCG3 - page 12
12 ...
-
American Water Heater BCG3 - page 13
13 HO T WA TER OUTLET TO TA NK INLET CHECK VA LV E MIXING VA LV E COLD WA TER INLET TEMPERED WA TER OUTLET 12” TO 15” (30-38 cm) CHECK VA LV E FIGURE 10. D I SH WAS H I NG M ACH I N ES ? ...
-
American Water Heater BCG3 - page 14
14 ...
-
American Water Heater BCG3 - page 15
15 ? ...
-
American Water Heater BCG3 - page 16
16 MUL TIPLE HEA TER MANIFOLD ? ...
-
American Water Heater BCG3 - page 17
17 ? ...
-
American Water Heater BCG3 - page 18
18 TYPE B GAS VENT Multiple Gas Fired T ank-T ype Heaters ? ...
-
American Water Heater BCG3 - page 19
19 MODEL (A)BCG3100T2506NOX Input: 250,000 Btu/hr T otal V ent Height (Feet) V ent Connector Size: 6 inches 6 8 10 15 20 30 50 100 Input Btuh/hr Rise V ent Connector Diameter (Inches) ? ...
-
American Water Heater BCG3 - page 20
20 W A TER HEA TER INST ALLA TION T&P V AL VE DISCHARGE PIPE Explosion Hazard Te mperature-Pressure Relief Va lv e must comply with ANSI Z21.22- CS A 4.4 and ASME code. Properly sized temperature- pressure relief valve must be installed in opening provided. Can result in overheating and excessive tank pressure. Can cause serious injury or death ...
-
American Water Heater BCG3 - page 21
21 INST ALLA TION DIAGRAMS - TOP INLET/OUTLET USAGE ? ...
-
American Water Heater BCG3 - page 22
22 HEA TER WIRING ? ...
-
American Water Heater BCG3 - page 23
23 GAS PIPING ? ...
-
American Water Heater BCG3 - page 24
24 PRIOR TO ST ART UP ? ...
-
American Water Heater BCG3 - page 25
25 CHECKING THE INPUT ...
-
American Water Heater BCG3 - page 26
26 SEQUENCE OF OPERA TION ? ...
-
American Water Heater BCG3 - page 27
27 SEQUENCE OF OPERA TION FLOW CHART FIGURE 24. ...
-
American Water Heater BCG3 - page 28
28 CHECK THE IG NITER AS SEMBL Y AN D MAI N BURNE RS ...
-
American Water Heater BCG3 - page 29
29 Explosion Hazard Te - ? ...
-
American Water Heater BCG3 - page 30
30 T A NK CLEA NOUT PROCEDUR E ...
-
American Water Heater BCG3 - page 31
31 ? ...
-
American Water Heater BCG3 - page 32
32 ...
-
American Water Heater BCG3 - page 33
33 ...
-
American Water Heater BCG3 - page 34
34 COMPLAINT CAUSE REMEDY USER QUALIFIED SERVICE AGENCY *W ater not hot enough temperature ? ...
-
American Water Heater BCG3 - page 35
35 W A TER PIPING DIAGRAMS N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi ce v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t r ...
-
American Water Heater BCG3 - page 36
36 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o ...
-
American Water Heater BCG3 - page 37
37 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o ...
-
American Water Heater BCG3 - page 38
38 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o ...
-
American Water Heater BCG3 - page 39
39 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o ...
-
American Water Heater BCG3 - page 40
40 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o ...
-
American Water Heater BCG3 - page 41
41 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o ...
-
American Water Heater BCG3 - page 42
42 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . MUL TI FLUE (2 UNITS) TWO TEMPERA TURE LEGEND TEMPERA TURE ...
-
American Water Heater BCG3 - page 43
43 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . MUL TI FL UE (2 UNITS) WITH BOOSTER TWO TEMPERA TURE LEGEND ...
-
American Water Heater BCG3 - page 44
44 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . MUL TI-FL UE (3 UNITS) LEGEND TEMPERA TURE & PRESSURE R ...
-
American Water Heater BCG3 - page 45
45 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o ...
-
American Water Heater BCG3 - page 46
46 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o ...
-
American Water Heater BCG3 - page 47
47 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . MUL TI FL UE FLUE (4 UNITS) LEGEND TEMPERA TURE & PRESS ...
-
American Water Heater BCG3 - page 48
48 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o ...
-
American Water Heater BCG3 - page 49
49 N OTES : 1. P re f erred piping diagram . 2. T he t empera t ure and pre ss ure relie f valve se tt ing shall no t exceed pressure ra t ing o f any componen t in t he sys t em . 3. S ervi c e v al v es are s hown f or ser v icing uni t. Howeve r , local codes shall govern t heir usage . 4. T he T ank T empera t ure Con t rol should be wired t o ...
-
American Water Heater BCG3 - page 50
50 MANIFOLD KITS MANIFOLD KITS TWO UNIT MANIFOLD KIT (P ART NO. 9003426205) THREE UNIT MANIFOLD KIT (P ART NO. 9003427205) FOUR UNIT MANIFOLD KIT (P ART NO. 9003428205) MODEL DIMENSION "A" BCG3 70T12 0 5NOX 63" BCG3 80T150 6NOX 68" BC G3 10 0T 18 0 6N OX 72" BCG3 95T199 6NOX 72" BC G3 10 0T 1 99 6N OX 72" A/BC G3 ...
-
American Water Heater BCG3 - page 51
W ARRANTY Commercial Limited W arranty ? ...
-
American Water Heater BCG3 - page 52
? ...
Avez-vous une question à propos de American Water Heater BCG3?
Utiliser le formulaire ci-dessous
Si vous n’avez pas résolu votre problème avec American Water Heater BCG3, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec American Water Heater BCG3 il est probable qu’il a envie de partager la façon de le résoudre.