    Installation instructions and Owner’s Manual 1 UNVENTED LP-GAS FIRE D ROOM HEA TER Blue Flame Heaters Plaqu e Heate rs Mod el # Bur n Rate Mod el # Bur n Rate MH BF 10 LP /H SB F1 0L P/ TS BF 10 LP 10,0 00 Bt u/hr MH I R 1 0 L P /H S I R 1 0 L P/ T S I R 1 0 LP 10,0 00 Bt u/hr MH BF 2 0L PT / HS BF 2 0L PT / TS BF 2 0L P T 20,0 00 Bt u/hr MH I R ...

  • Enerco MHBF10LP - page 2

    2 Installation instructions and Owner’s Manual 70575 Rev . E 04/07 This appliance may be installed in an aftermarket* permanently manufactured (mobile) home, where not prohibited by local codes.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with any other gas. *Aftermar ...

  • Enerco MHBF10LP - page 3

    Installation instructions and Owner’s Manual 3 Product Features Figure 1 SAFETY DEVICE This heater has a pilot with an Oxygen Depletion Sensor (ODS) safety shut off system. The ODS/pilot shuts off the heater if there is not enough fresh air . IGNITION SYSTEM PIEZO: BF10LP/ IR10LP – The heater is equipped with a piezo manual ignitor . This syste ...

  • Enerco MHBF10LP - page 4

    4 Installation instructions and Owner’s Manual 70575 Rev . E 04/07 installed in that space, and an unconfined space as a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8 m 3 per kW) of the aggregate input rating of all appliances installed in that space. Rooms communicating directly with the space in which the applian ...

  • Enerco MHBF10LP - page 5

    Installation instructions and Owner’s Manual 5 Figure 3. V entilation from Out doors If necessary , provide extra fresh air by using ventilation grilles or ducts. Connect these items directly to the outdoors or sp aces open to the out doors. These include attics* and crawl spaces. Follow the National Fuel Gas Code NFP A 54/ ANSI Z223.1, Section 5 ...

  • Enerco MHBF10LP - page 6

    6 Installation instructions and Owner’s Manual 70575 Rev . E 04/07 Figure 4 F ASTENING HEA TER TO W ALL Mounting Bracket The mounting bracket in located on the back panel of heater (see figure 5). It has been taped there for shipping. Remove mounting bracket from back panel. Figure 5 Removing Front Panel of Heater 1. Remove three screws on bottom ...

  • Enerco MHBF10LP - page 7

    Installation instructions and Owner’s Manual 7 1. Drill holes at marked locations using 5/16” drill bit. For solid walls (concrete or masonry), drill at least 1” deep. 2. Fold wall anchor as shown in figure 8 below . Figure 8. 3. Insert wall anchor (wings first) into hole. T ap anchor flush to wall. 4. For thin walls (1/2” or less) insert r ...

  • Enerco MHBF10LP - page 8

    8 Installation instructions and Owner’s Manual 70575 Rev . E 04/07 W ARNING: This appliance requires a 3/8” NPT (National Pipe Thread) inlet connection to the pressure regulator . Use of floor mounting feet will require you to use a 3/8 NPT street elbow to make gas connection. CAUTION: Never connect heater directly to the Propane supply . This ...

  • Enerco MHBF10LP - page 9

    Installation instructions and Owner’s Manual 9 Pressure T esting Heater Gas Connections: 1. Make sure that the heater supply piping system is connected and has been leak tested as described above. 2. Make sure control knob of heater is in OFF position. 3. Open equipment shutoff valve (see figure 13). 4. Open propane/LP supply valve. 5. Check all ...

  • Enerco MHBF10LP - page 10

    10 Installation instructions and Owner’s Manual 70575 Rev . E 04/07 C . Use only your hand to push in or turn the gas control knob. Never use tools. If knob will not push in or turn by hand, don’t try to repair it; call a qualified service technician or gas supplier . Force or attempted repair may result in a fire or explosion. D. Do not use th ...

  • Enerco MHBF10LP - page 11

    Installation instructions and Owner’s Manual 11 TO TURN OFF GAS T O APPLIANCE SHUTTING OFF HEA TER: 1. Turn control knob clockwise to the OFF position. 2. Turn off all electrical power to the appliance if servicing is to be preformed. 3. Turn off equipment shutoff valve. SHUTTING OFF BURNER ONL Y (PILOT ST A YS LIT) 1. Turn control knob clockwise ...

  • Enerco MHBF10LP - page 12

    12 Installation instructions and Owner’s Manual 70575 Rev . E 04/07 8. When the pilot is lit, turn control knob counter- clockwise to heating level. The main burner should light. 9. T o select the desired heat level, turn the tem- perature setting knob counterclockwise to between 1 & 5. THERMOST A T CONTROL OPERA TION FOR IR20LPT / IR30LPT : ...

  • Enerco MHBF10LP - page 13

    Installation instructions and Owner’s Manual 13 Figure 24a Figure 24b CLEANING AND MAINTENANCE W ARNING: T urn off heater and let cool before servicing. CAUTION: Y ou must keep control areas, burner and circulation air passageways of heater clean. Inspect these areas of heater before use. Have the heater inspected yearly by a qualified service pe ...

  • Enerco MHBF10LP - page 14

    14 Installation instructions and Owner’s Manual 70575 Rev . E 04/07 TROUBLESHOOTING NOTE: All troubleshooting items are listed in order of operation and likely occurrence. W ARNING: Only a qualified service person should service and repair heater . CAUTION: Never use a wire needle, or similar object to clean ODS/pilot. This can damage ODS/pilot u ...

  • Enerco MHBF10LP - page 15

    Installation instructions and Owner’s Manual 15 TROUBLESHOOTING W ARNING: If you smell gas: • Shut off gas supply • Do not try to light any appliance • Do not touch any electrical switch; do not use any phone in your building • Immediately call you gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If yo ...

  • Enerco MHBF10LP - page 16

    16 Installation instructions and Owner’s Manual 70575 Rev . E 04/07 SPECIFICA TIONS IR10 LP IR20LPT IR30LPT BTU (Available) 10,000 20,000 30,000 T ype of Gas LP-Gas Only LP-Gas Only LP-Gas Only Ignition Piezo Battery ignitor (1-AA) Battery ignitor (1-AA) Pressure Regulator Setting 10 Inches of W ater 10 Inches of W ater 10 Inches of W ater Inlet ...

  • Enerco MHBF10LP - page 17

    Installation instructions and Owner’s Manual 17 REPLACEMENT P ARTS Note: use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty . P ARTS UNDER W ARRANTY Contact authorized dealer from whom you purchased this product. If they are unable to supply original replacement part(s), call the number ...

  • Enerco MHBF10LP - page 18

    18 Installation instructions and Owner’s Manual 70575 Rev . E 04/07 Thermostat models 2 20-2 36 39 38 35 16 21 20-1 16-1 16-2 33-2 6 8 26 30 29 17 34 24 3-5 22-3 31-1 31-1 19 13 23 18 10 32 12 3-3 3-1 3-2 3-4 11 1-2 1-4 31-3 31-2 22-2 33-1 22-1 25 9 5 1-3 1-1 27-1 28-1 IR20LPT IR30LPT 5 6 15 17 13 14 30 12 2 42 9 7 24 26 23 25 22-1 33-2 22-3 22-1 ...

  • Enerco MHBF10LP - page 19

    Installation instructions and Owner’s Manual 19 IR20L P T BF20L P T IR30LPT BF 30LPT 1 70600 70600 70605 70605 Cabinet As sem bly 1 1-1 70601 70601 70 606 706 06 Cabinet, Pa nel , Top 1 1-2 70603 70603 70 603 706 03 Cabinet, Pa nel , Right 1 1-3 70602 70602 70 607 706 07 Cabinet, Pa nel , Back 1 1-4 70704 70704 70 704 707 04 Cabinet, Pa nel , Lef ...

  • Enerco MHBF10LP - page 20

    20 Installation instructions and Owner’s Manual 70575 Rev . E 04/07 ** Not sold separately – Must purchase Assembly * Items not shown 29 70 683 70683 7 068 3 7068 3 Fan 1 30 70 684 70684 70684 70684 Fan Motor 1 31-1 70685 70685 7068 5 70685 Fan Mo unti ng Bracket 2 31-2 70686 70686 7068 6 70686 Fan V enturi 1 31-3 70687 70687 7068 7 70687 Fan C ...

  • Enerco MHBF10LP - page 21

    Installation instructions and Owner’s Manual 21 NON-Thermostat models 33-1 22-1 1-1 3-1 3-3 3-2 3-6 3-5 26 7 8 23 24 13 1-4 1-2 1-3 6 15 14 42 5 22-3 22-2 20-2 16-2 16-1 16 2 20-1 BF10LP 27-2 16-2 16-1 16 21 20-2 40 38 36 20-1 22-2 35 29-1 33-1 22-1 1-4 1-2 1-1 1-3 23 2 24 5 10 13 42 3-1 3-3 3-2 3-4 3-5 26 7 8 22-3 IR10LP 6 4 43 44 44 ...

  • Enerco MHBF10LP - page 22

    22 Installation instructions and Owner’s Manual 70575 Rev . E 04/07 P ARTS LIST Non-Thermostat model IR10LP , BF10LP , IR10 LP , BF10LP This list contains replacement part s used in your heater . When ordering part s, follow the instructions listed under Replacement Parts on page 17 of this manual. ITEM PA R T N O . DESCRIPTION QTY . IR10LP BF10L ...

  • Enerco MHBF10LP - page 23

    Installation instructions and Owner’s Manual 23 36 70336 -- - Bracket, Bottom, Plenum Assembly 1 38 70677 --- Burner Plaques, 10 2 40 70678 --- Plaque Gasket, 10 2 42 70337 70337 Control V alve Knob 1 43 70318 Plenum Assembly 1 44 70597 70597 3/8" FPT x 3/8" MPT Elbow * 70352 - -- Right Burner gas tube 1 * 70353 --- Left burner gas tube ...

  • Enerco MHBF10LP - page 24

    24 Installation instructions and Owner’s Manual 70575 Rev . E 04/07 W ARRANTY INFORMA TION Keep this warranty Model _______________________ Serial No. ____________________ Date Purchased _______________ Always specify model and serial numbers when communicating with the factory . We reserve the right to amend these specifications at any time with ...

Fabricant Enerco Catégorie Work Light

Les documents que nous recevons du fabricant de l'appareilEnerco MHBF10LP peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Enerco
- manuels d’utilisations MHBF10LP
- fiches produit Enerco
- dépliants
- ou étiquettes-énergie Enerco MHBF10LP
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Enerco MHBF10LP.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Enerco MHBF10LP, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Enerco MHBF10LP. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Enerco MHBF10LP.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Enerco MHBF10LP, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Enerco MHBF10LP par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Enerco MHBF10LP.

Le manuel d’utilisation complet Enerco, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Enerco MHBF10LP - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Enerco MHBF10LP, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lEnerco MHBF10LP qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Enerco MHBF10LP - qui devraient nous aider dans les premières étapes lors de l'utilisation Enerco MHBF10LP
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Enerco MHBF10LP
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Enerco MHBF10LP dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Enerco MHBF10LP?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Enerco MHBF10LP, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Enerco MHBF10LP il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)