Brookstone BWM-2110 - page 1
U V S A N I T I Z I N G . P U R I F I E D WAR M M I ST . Germ-F r ee Humidifier 636126_I NS0210_GermFreeHumidifier_5”W x4.75”H_Output:100%_Prints:1/1,Blk Model Number BWM-211D ...
-
Brookstone BWM-2110 - page 2
1 T AB LE OF C ONTE NTS W a r n i n g s a n d C a u t i o n s .................................................. 2 - 6 L o c a t i o n o f C o n t r o l s ..................................................... 7 - 8 O p e r a t i o n .............................................................. 9 - 1 0 F i l l i n g t h e W a t e r T a n k ........ ...
-
Brookstone BWM-2110 - page 3
2 CA UTION • T O R E DU C E TH E R IS K O F E LECTRI C SH OC K, DO N OT R E M OVE COVE R. TH E R E AR E N O SE RVI C EAB LE P ARTS I N SI DE. • T O R E DU C E TH E R IS K O F FI R E OR E LECTRI C SH O CK, D O N OT EX POSE TH IS U N IT TO R AI N OR M OI STU R E. The lightning flash with arrow-head symb ol within an equilateral triangle is intend ...
-
Brookstone BWM-2110 - page 4
DANG E R T o reduce the risk of electric shock, burns, fire or injury: 1. Do not use while bathing or in a shower. 2. Do not place or store unit where it can fall or be pulled into a tub or sink. 3. Do not place in, drop or submerge in water or other liquid. 4. Do not reach for unit that has fallen into water. Unplug it immediately . 5. Care should ...
-
Brookstone BWM-2110 - page 5
8. Never block the air openings of the unit with materials such as clothing, plastic bags or papers, or place it on a soft surface such as a bed or couch, where the air openings may be blocked. 9. Do not overload electrical outlet. Use only the power source as indicated. 10. Do not carry this unit by cord or use cord as handle. 11. Never operate th ...
-
Brookstone BWM-2110 - page 6
I M P ORT ANT SAF EG UAR DS CA UTI O N: B ECAUS E H IG H TE M PE RA TU R E S AR E G E N E RA TE D I N TH I S H U M I D I F I E R, BASI C S AF ETY P R E CAUTIO N S S H O U LD A L WA YS B E FO LL OWE D, ES P E C IALL Y WH E N C H I L DR E N A R E P R E S E NT . W hen using electrical appliances, these basic safety precautions must be followed: 1. DO ...
-
Brookstone BWM-2110 - page 7
13. AL W A Y S place the unit on a firm, flat, level, water-resistant surface and arrange the power cord so that the product is unlikely to be upset. 14. DO NOT clean the product or service the UV bulb without disconnecting the power cord. 15. Before connecting to electric power outlet, check your electrical power supply . It must be 120 volts AC ( ...
-
Brookstone BWM-2110 - page 8
L O CA TION OF P ARTS AN D C ONTROLS 1. W ater T ank 2. T ank Handle 3. Medication Cup 4. Mist Outlet Grille 5. Mineral Absorption Pad 6. Hot W ater Reservoir 7 . Base 8. Base Drain Cap & Gasket 9. Digital Control Panel 10. Cold W ater Reservoir 11. T ank Cap with Gaske t 7 6 5 4 3 2 1 11 10 9 8 7 ...
-
Brookstone BWM-2110 - page 9
DIG IT AL CONTROL P AN E L 636126_I NS0210_GermFreeHumidifier_5”W x4.75”H_Output:100%_Prints:1/1,Blk 8 1. P ower/ Mode Button 2. P ower Indicator Light 3. Replace UV Bulb Indicator Light 4. Refill T ank Indicator Light 5. Humidity Level Button 6. Mode Screen Indicator 7 . Set Humidity Screen Indicator 8. Percent Humidity Screen Indicator 5 6 7 ...
-
Brookstone BWM-2110 - page 10
OP E RA TI NG I N STR UCTION S Carefully unpack humidifier and remove all packing material. NOTE: W hen you unpack your humidifier, you may find it has droplets of water on some surfaces. This is normal as every unit is tested prior to shipping. AB O UT P OWE R / M O D E POWER / MO DE button can be pushed to either O FF , H I or L O mode. On H I, h ...
-
Brookstone BWM-2110 - page 11
OP E RA TION 1. Place the base of the unit on a firm, flat, level and water-resistant surface. 2. Fill the WA TE R T AN K according to the instructions on the next page and place it on the humidifier base. 3. Plug the power cord firmly and completely into the wall outlet. 4. P ush POWER / MO DE switch to either the H I or L O position. Push S ET H ...
-
Brookstone BWM-2110 - page 12
F I LL I NG TH E W A TE R T AN K R E F I LL WH E N LIT—W hen illuminated, the water tank needs refilling. “R E F” will also be indicated in the MO D E window at this time. If still illuminated after full tank is placed on base, see TRO U B LESHO O TI NG section. 1. Before filling the WA TE R T AN K, push POWE R / M OD E switch until OF F appe ...
-
Brookstone BWM-2110 - page 13
W AR N I NG: D O NOT use any liquid medication other than those specifically recommended for use with a steam vaporizer or warm mist humidifier . DO N O T pour medication directly into the M I ST O UTLET G R I LLE openings nor add it to the water in the tank or tray. M I N E RAL AB SOR PTION P AD I N STR UC TION S W arm mist humidifiers do not spre ...
-
Brookstone BWM-2110 - page 14
CLEAN I NG AN D MAI NTE NANCE W ater contains minerals and other particles. During operation, most of these minerals will remain in the water reservoir . Gradual buildup of deposits will coat the hot water reservoir and reduce its efficiency . The importance of routine cleaning and care cannot be over-emphasized. Hard water contains more minerals a ...
-
Brookstone BWM-2110 - page 15
5. Pour ab out 1 cup of white vinegar into either reservoir and allow it to soak for only 20 to 3 0 minutes. 6. Hold the base of the humidifier over the sink and tilt it on its side to empty the vinegar. Fill the cold and hot water reservoirs with clean, warm water to remove all traces of the vinegar. Remove any buildup of minerals in the hot water ...
-
Brookstone BWM-2110 - page 16
R E P LACI NG UV B U LB If the R E PLACE UV B U LB WH E N LIT signal light is illuminated during normal use, the bulb must be replaced with the same special 3.5W bulb, E UV-13B. The UV bulb will operate at maximum output for approximately 2,000 hours. The UV bulb may operate longer than 2,000 hours but at a reduced output. T o keep your humidifier ...
-
Brookstone BWM-2110 - page 17
8. T ake a repl acem ent 3.5 W UV bulb that you purc hase d from K az Inc orpo rate d or anot her supp lier and ch ange the bulb . T o prol ong the life of the bulb , limi t your dir ect co ntac t with the glas s of the bul b by usin g a cloth or tissue to screw it into pla ce. Mai l quest ions or com ment s to: Ka z, Inc orpo rate d, Cons umer Rel ...
-
Brookstone BWM-2110 - page 18
I M P ORT ANT NOTE: Even though you will not receive maximum germicidal effects, you can still use your humidifier until the replacement bulb arrives. NOTE: Y ou may hear a rattling sound and notice a small, round object inside your bulb. This is normal. Y our bulb is fully operational. NOTE: Discard the old UV bulb cartridge at a household hazardo ...
-
Brookstone BWM-2110 - page 19
S P ECI F ICA TION S Output per Da y: . . . . . . . . . . . . . . . . . . . . . . . . 2 G allons Electrical usage:. . . . . . . . . . . . . . . . . . . . . . . . 26 0W High, 130W Low W eight (without water): . . . . . . . . . . . . . . . . . 6.34 lbs W ater T ank Capacity: . . . . . . . . . . . . . . . . . . . 2.1 Gallons Dimensions (approximately) ...
-
Brookstone BWM-2110 - page 20
TROU B LE S HO O TI NG IS S U E PO S S I B LE CA US E SO LUTI O N Unit does not mist. Unit is not plugged in. P ower failure. W ater tank is empty . P ower switch not turned on. Unit still on R E F I LL after refilling tank. Float on b ottom of tank “hangs up” . W ater tank not properly situated on base. Humidity level set is achieved. Plug in ...
-
Brookstone BWM-2110 - page 21
636126_I NS0210_GermFreeHumidifier_5”W x4.75”H_Output:100%_Prints:1/1,Blk TROU B LE S HO O TI NG (Continued) IS S U E PO S S I B LE CA US E SO LUTI O N W ater leaks from main unit. Moist air output low. Base Drain Cap and Gasket, tank cap or tank cap gasket are missing or improperly positioned. Mineral buildup in hot water reservoir. Tighten ca ...
-
Brookstone BWM-2110 - page 22
ON E (1) YEAR LI M ITE D W AR RANT Y Brookstone ® warrants this product against defects in materials and/or workmanship under normal use for a period of ON E (1) YEAR from the date of purchase by the original purchaser (“W arranty Period”). If a defect arises and a valid claim is received within the W arranty P eriod, at its option, Brookstone ...
-
Brookstone BWM-2110 - page 23
but Brookstone, in so far as permitted by law , provides these products “as is. ” This warranty does not apply to: a) damage caused by failure to follow instructions relating to product’s use or the installation of components; b) damage caused by accident, abuse, misuse, fire, floods, earthquake or other external causes; c) damage caused by s ...
-
Brookstone BWM-2110 - page 24
63612 6 Rev. 0710 31I M211D192 Merrimack, New Hampshire USA 03 054 • 8 00-846-3 000 • www .Brookstone.com ...
Avez-vous une question à propos de Brookstone BWM-2110?
Utiliser le formulaire ci-dessous
Si vous n’avez pas résolu votre problème avec Brookstone BWM-2110, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Brookstone BWM-2110 il est probable qu’il a envie de partager la façon de le résoudre.