    INST ALLA TION, OPERA TION, & MAINTENANCE F AN COIL AIR CONDITIONERS Supersedes: Form 1 15.20-NOM3 (105) Form 1 15.20-NOM3 (1006) ***** W ARNING T O INST ALLER, SERVICE PERSONNEL AND OWNER ***** Altering the product or replacing parts with non authorized factory parts voids all warranty or implied warranty and may result in adverse operational ...

  • York YVF/YVS - page 2

    YORK INTERNA TIONAL 2 FORM 1 15.20-NOM3 (1006) T ABLE OF CONTENTS FIG. 1 – VERTICAL UNITS ONL Y - YVC, YWC, YVF , YVS AIR FLOW FIG. 1 – VERTICAL UNITS ONL Y - YVC, YWC, YVF , YVS AIR FLOW Reference Documents: • IOM for YH (Horizontal Units) Form 1 15.20-NOM3 (Latest) • IOM for YSHW , YSHX Form1 15.22-NOM5 (Latest) • IOM for YSVW , YSVX Fo ...

  • York YVF/YVS - page 3

    3 YORK INTERNA TIONAL INST ALLA TION FORM 1 15.20-NOM3 (1006) RECEIVING Material in this shipment has been inspected at the factory and released to the transportation agency in good condition. When received, a visual inspection of all cartons should be made immediately . Any evidence of rough handling or apparent damage should be noted on the deliv ...

  • York YVF/YVS - page 4

    YORK INTERNA TIONAL 4 FORM 1 15.20-NOM3 (1006) INST ALLA TION WIRING All wirin g must comply wit h the lo cal and nation al code requirements . Units are provided with wiring diagram s and nameplate data to provide information required for necessary field wiring. For power wiring a control box is provided on the cabinet for connection of power sup ...

  • York YVF/YVS - page 5

    5 YORK INTERNA TIONAL INST ALLA TION FORM 1 15.20-NOM3 (1006) H L ( L 1 ) N ( L 2 ) P O W E R S U P P L Y G R D 1 2 3 4 1 2 3 4 T B 1 -1 T B 1- 2 T B 3 -1 T B 3 -2 T B 2 -2 T B 2 -4 T B 2 -3 T B 1 -4 T B 2-1 H E A T O F F C O O L ME D H I H E A T C O O L L O T B 3 -3 T B 2 -5 MO T O R C V A L V E S T H E R MIS T O R ( U N IT - MT D ) T B 1 -1 T B 1 ...

  • York YVF/YVS - page 6

    YORK INTERNA TIONAL 6 FORM 1 15.20-NOM3 (1006) INST ALLA TION Many valve packa ges will not phys- ically allow all compon ents to fit over an auxiliary drain pan. It is the installers responsibility to ensure ad- equate condensation prevention. The installer must also ensure that there is no condensate drippage onto elec- trical components beneath ...

  • York YVF/YVS - page 7

    7 YORK INTERNA TIONAL INST ALLA TION FORM 1 15.20-NOM3 (1006) FIG. 7 - F AN COIL UNITS - DIRECT DRIVE, MODEL YVS & YVF 19 19-3/8 CONTROL ACCESS DOOR A RETURN AIR OPENING 8-1/8 8-1/8 1/2 1/2 1/2 DIA. MTG. HOLES 2 EACH SIDE 5/16 DIA. MTG. HOLES 2 EACH SIDE OPTIONAL BACK FRESH AIR INT AKE DAMPER AND INSECT SCREEN (SEE DET AIL) *DIMENSIONS MA Y V A ...

  • York YVF/YVS - page 8

    YORK INTERNA TIONAL 8 FORM 1 15.20-NOM3 (1006) INST ALLA TION FIG. 8 - F AN COIL UNITS - DIRECT DRIVE, MODEL YVC UNIT SIZES 10 & 12 Have two openings 2" apart centered on center line C L 16 2-1/2 1/2 *DIMENSIONS V ARY FOR UNITS WITH NON ST ANDARD V AL VE P ACKAGES ALL DIMENSIONS ARE IN INCHES SUPPL Y & RETURN W A TER CONNECTIONS 1/2 DI ...

  • York YVF/YVS - page 9

    9 YORK INTERNA TIONAL INST ALLA TION FORM 1 15.20-NOM3 (1006) FIG. 9 - F AN COIL UNIT DIMENSIONS - DIRECT DRIVE, MODEL YWC LDO10324 GENERAL DIMENSIONS IN INCHES MODEL A C D E COIL CONN SIZE COOLING HEA TING 3 YWC 27-1/2 25-1/2 26-1/2 22-3/4 5/8 O.D. SWEA T 5/8 O.D. SWEA T 4 YWC 35-1/2 33-1/2 34-1/2 31-3/4 6 YWC 43-1/2 41-1/2 42-1/2 39-3/4 8 YWC 51- ...

  • York YVF/YVS - page 10

    YORK INTERNA TIONAL 10 FORM 1 15.20-NOM3 (1006) INST ALLA TION SUPPL Y & RETURN W A TER CONNECTIONS 1/2 DIA. MTG HOLES 2 EACH SIDE WIDTH HEIGHT RETURN AIR OPENING (RIGHT HAND UNIT SHOWN) (RIGHT HAND UNIT SHOWN) A MODEL DR YW ALL CUTOUT DIMENSIONS MODEL HEIGHT WIDTH MINIMUM HEIGHT ABOVE FLOOR (A) 3YWC 28" 42" 6" 4YWC 28 50" 6 ...

  • York YVF/YVS - page 11

    1 1 YORK INTERNA TIONAL INST ALLA TION FORM 1 15.20-NOM3 (1006) F AN COILS ST ART - UP CHECKLIST Fan INSPECTION - The fan should be inspected and cleaned, in conjunction with maintenance of the motor and bearings. It is important to keep the wheel clean in order to avoid imbalance and vibration. ❑ Check tightness of fan bearing locking collar . ? ...

  • York YVF/YVS - page 12

    MAINTENANCE MOTOR The blower motor should be cleaned annually and if it has oiling ports, it should be oiled with a good grade of SAE 20 oil. Normally a few drops of oil in each bearing is sufficient. If motor service is required, it can be removed in the following manner: 1. Disconnect electrical power to the unit at the discon- nect switch and l ...

Fabricant York Catégorie Air Conditioner

Les documents que nous recevons du fabricant de l'appareilYork YVF/YVS peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques York
- manuels d’utilisations YVF/YVS
- fiches produit York
- dépliants
- ou étiquettes-énergie York YVF/YVS
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation York YVF/YVS.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation York YVF/YVS, manuels d’entretien, brefs manuels ou manuels de l’utilisateur York YVF/YVS. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit York YVF/YVS.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil York YVF/YVS, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser York YVF/YVS par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs York YVF/YVS.

Le manuel d’utilisation complet York, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel York YVF/YVS - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières York YVF/YVS, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lYork YVF/YVS qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil York YVF/YVS - qui devraient nous aider dans les premières étapes lors de l'utilisation York YVF/YVS
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de York YVF/YVS
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service York YVF/YVS dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de York YVF/YVS?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec York YVF/YVS, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec York YVF/YVS il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)