Manuel d’utilisation IBM Modbus Plus

22 pages 0.03 mb
Télécharger

Aller à la page of 22

Summary
  • IBM Modbus Plus - page 1

    Modbus Plus X-Link Driver User’s Guide Version 1.22 50 Northland Road Waterloo, Ontario, CANADA N2V 1N3 Tel: (519) 725- 5136 Fax: (519) 725-1515 www.sstech.on.ca ...

  • IBM Modbus Plus - page 2

    Modbus Plus X-Link Driver User’s Guide 36 Publication Revision: 1.22 Publication Date: January 15, 1999 This document applies to the Modbus Plus X-Link Driver (SA85.DRV). Copyright © 1999 SST, a division of Woodhead Canada Limited All rights reserved. No portion of this document may be reproduced in any form without the prior written permission ...

  • IBM Modbus Plus - page 3

    Modbus Plus X-Link Driver User’s Guide 37 Contents 1. Introduction ........................................................... 39 1.1 What is the Modbus Plus Driver? ............................. 39 1.2 Why Do I Need This Manual? .................................. 40 1.3 How Do I Use This Manual? .................................... 41 1.4 Where ...

  • IBM Modbus Plus - page 4

    Modbus Plus X-Link Driver User’s Guide 38 ...

  • IBM Modbus Plus - page 5

    Introduction 39 1 Introduction 1.1 What is the Modbus Plus Driver? The Modicon Modbus Plus X-Link driver allows the X-Link to transfer data to or from devices on the Modicon Modbus Plus network. ...

  • IBM Modbus Plus - page 6

    Modbus Plus X-Link Driver User’s Guide 40 1.2 Why Do I Need This Manual? This manual describes the communication requirements and capabilities of the Modbus Plus driver, the configuration parameters for the driver and the mappings possible for the Modicon PLCs. It provides troubleshooting information and technical specifications that can be refer ...

  • IBM Modbus Plus - page 7

    Introduction 41 1.3 How Do I Use This Manual? The following conventions will help you better understand and use the material in this manual. Text you type appears in Courier font. For example, “Type mkdir C:XLINK to make a new X-Link directory.” Menu Names are italicized. You choose menu options. For instance, “Choose the X -Link/New... comm ...

  • IBM Modbus Plus - page 8

    Modbus Plus X-Link Driver User’s Guide 42 1.4 Where Can I Find More Help? If you have a question or problem that the manuals or on-line help do not address, you can contact X-Link Technical Support by mail, fax or email, or by phone during regular business hours (EST). X-Link Technical Support SST, a division of Woodhead Canada Limited 50 Northla ...

  • IBM Modbus Plus - page 9

    Communication 43 2 Communication Once configured, the X-Link emulates a station on the Modbus Plus network. It can send messages to other stations and receive messages from other stations. This section outlines the requirements and compatibilities of this communication. ...

  • IBM Modbus Plus - page 10

    Modbus Plus X-Link Driver User’s Guide 44 2.1 Requirements To communicate to the Modbus Plus network, the X-Link requires a Modicon SA85 card. The X-Link Modbus Plus driver supports either the redundant or non-redundant version of the SA85. Installation and cabling requirements are detailed in the SA85 user manual, Modicon IBM Host Based Devices ...

  • IBM Modbus Plus - page 11

    Configuration 45 3 Configuration When you download a driver to the X-Link, you must set configuration parameters to control the interface between the driver and the required hardware. This section details the configuration parameters for the Modbus Plus driver. ...

  • IBM Modbus Plus - page 12

    Modbus Plus X-Link Driver User’s Guide 46 3.1 Configuration Parameters The Modbus Plus driver is distributed in the file SA85.DRV. Once the SA85.DRV is loaded into the X -Link, the following parameters are required: Card Segment The memory address for the SA85 card. The card requires 2K of memory in the range of C000 to EF80. Default is D000, sec ...

  • IBM Modbus Plus - page 13

    Mappings 47 4 Mappings Once the X-Link has been loaded, you can create mappings to transfer data from one network to the other. This section outlines the mapping options supported by the Modbus Plus driver. For information on what mappings are or how they work, please refer to the X-Link User's Guide . ...

  • IBM Modbus Plus - page 14

    Modbus Plus X-Link Driver User’s Guide 48 4.1 Data Ty pes and Lengths The Modbus Plus Driver supports three X-Link data formats; Bits and Integers, as well as Floats. The Modbus Plus protocol does not support floating point. The driver will truncate any floating point numbers before transmission, and expand the integer numbers to floating point a ...

  • IBM Modbus Plus - page 15

    Mappings 49 4.2 Source Accesses The Modbus Plus driver supports four possible source accesses. The first source defines a local address which allows any device on the Modbus Plus network to write the data to the X-Link. This type of source is ideal for data that changes infrequently, but must be forwarded immediately, such as errors or exceptions. ...

  • IBM Modbus Plus - page 16

    Modbus Plus X-Link Driver User’s Guide 50 4.3 Destination Accesses The Modbus Plus driver supports three possible destination accesses. The first destination defines a local address which allows any device on the Modbus Plus network to read the data from the X-Link. This type of destination can be used to allow a PLC to read back the data it has ...

  • IBM Modbus Plus - page 17

    Mappings 51 4.4 Local Addresses When a mapping is created which allows a PLC to access data within the X -Link, a local address dialog box must be completed. The information required to complete a local address definition is the class of data to access (Coils, Input Status, Input Registers or Holding Registers) and the offset into the data table. I ...

  • IBM Modbus Plus - page 18

    Modbus Plus X-Link Driver User’s Guide 52 4.6 Status Counters The status counters are maintained within the Modbus Plus driver for logging events and errors. The Status menu allows you to monitor some of these counters. As well, the status counters can be accessed as a data source for mappings. The Modbus Plus driver status counters include count ...

  • IBM Modbus Plus - page 19

    Troubleshooting 53 5 Troubleshooting If you cannot communicate with your X-Link, refer to the troubleshooting section in the X-Link User's Guide. If you can communicate with your X-Link, but cannot monitor the status of your Modbus Plus driver, you most likely have the memory address set incorrectly. Refer to your SA85 User Manual to confirm y ...

  • IBM Modbus Plus - page 20

    Modbus Plus X-Link Driver User’s Guide 54 ...

  • IBM Modbus Plus - page 21

    Specification 55 6 Specification 6.1 Driver CMOS Storage Requirements Driver Code and Parameters 16 Kbytes Each Global Data Read Address 4 bytes Each Global Data Write Address 3 bytes Each Internal Address 5 bytes Each External Address 10 bytes Each Status Counter Address 2 bytes ...

  • IBM Modbus Plus - page 22

    Modbus Plus X-Link Driver User’s Guide 56 ...

Fabricant IBM Catégorie Computer Drive

Les documents que nous recevons du fabricant de l'appareilIBM Modbus Plus peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques IBM
- manuels d’utilisations Modbus Plus
- fiches produit IBM
- dépliants
- ou étiquettes-énergie IBM Modbus Plus
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation IBM Modbus Plus.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation IBM Modbus Plus, manuels d’entretien, brefs manuels ou manuels de l’utilisateur IBM Modbus Plus. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit IBM Modbus Plus.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil IBM Modbus Plus, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser IBM Modbus Plus par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs IBM Modbus Plus.

Le manuel d’utilisation complet IBM, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel IBM Modbus Plus - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières IBM Modbus Plus, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lIBM Modbus Plus qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil IBM Modbus Plus - qui devraient nous aider dans les premières étapes lors de l'utilisation IBM Modbus Plus
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de IBM Modbus Plus
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service IBM Modbus Plus dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de IBM Modbus Plus?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec IBM Modbus Plus, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec IBM Modbus Plus il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)