    IMPORTANT: Read and understand this manual before assembling, start- ing or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference. R POR T ABLE FORCED AIR HEA TERS OWNER’S MANUAL Heater Sizes: 35,000 70,000 100,000 150,000 Btu/Hr Models: BY35CEB, BY70CEB, BY100CEB, and BY150CEB ...

  • Desa BY150CEB - page 2

    2 103618 POR T ABLE FORCED AIR HEA TERS R Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nau- sea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These ...

  • Desa BY150CEB - page 3

    3 103618 OWNER’S MANUAL PRODUCT IDENTIFICA TION Side Cover Lower Shell Fuel Cap Hot Air Outlet Upper Shell Flame-Out Control Reset Button Power Cord Figure 2 - 100/150,000 Btu/Hr Models Fuel Tank Fan Guard Lower Shell Side Cover Fuel Tank Upper Shell Hot Air Outlet Handle Fan Guard Air Filter End Cover Fuel Cap Figure 1 - 35/70,000 Btu/Hr Models ...

  • Desa BY150CEB - page 4

    4 103618 POR T ABLE FORCED AIR HEA TERS R FUELS Do not use heavy fuels such as No. 2 fuel oil or No. 2 Diesel. Using heavy fuels will result in: • clogged fuel filter and nozzle • carbon build up on spark plug • use of non-toxic anti-icer in fuel during very cold weather IMPORTANT: Use a KEROSENE ONLY container. Be sure storage container is ...

  • Desa BY150CEB - page 5

    5 103618 OWNER’S MANUAL Electronic Ignitor Fan Fuel Filter Air For Fuel System Air For Combustion And Heating Fuel Spark Plug Combustion Chamber Intake Air Filter Motor Air Pump Air Line To Burner Burner Head Clean Heated Air Out Cool Air In Output Air Filter Nozzle Fuel Tank THEOR Y OF OPERA TION The Fuel System: The air pump forces air through ...

  • Desa BY150CEB - page 6

    6 103618 POR T ABLE FORCED AIR HEA TERS R STORING, TRANSPOR TING, OR SHIPPING Note: If shipping, transport companies re- quire fuel tanks to be empty. 1. Drain fuel tank. Note: Some models have drain plug on underside of fuel tank. If so, remove drain plug to drain all fuel. If heater does not have drain plug, drain fuel through fuel cap open- ing. ...

  • Desa BY150CEB - page 7

    7 103618 OWNER’S MANUAL TROUBLESHOOTING WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur. REMEDY 1. See Pump Pressur e Adjustment , pa ge 10. 2. See Air Output, Air Intake and Lint F il- ters , page 10. 3. See Fuel F ilter , page 8. 4. See Nozzle , page 11. 5. Clean photocell len ...

  • Desa BY150CEB - page 8

    8 103618 POR T ABLE FORCED AIR HEA TERS R Figure 9 - Fuel Filter Removal, 35/70,000 Btu/Hr Models Upper Shell Removal 1. Remove screws and lock washers along each side of heater using 5/16" nut- driv er . These scre ws attach upper and lower shells together . 2. Lift upper shell off. 3. Remove fan guard. Fuel Filter (35/70,000 Btu/Hr Models) 1 ...

  • Desa BY150CEB - page 9

    9 103618 OWNER’S MANUAL Spark Plug (35,000 Btu/Hr Model) 1. Remove upper shell (see page 8). 2. Remove fan (see page 13). 3. Remove fuel and air line hoses from nozzle assembly . 4. Remove spark plug wire from spark plug. 5. Remove two screws using 5/16" nut- driver and remove burner strap. 6. Place hex-body of spark plug into vise and tight ...

  • Desa BY150CEB - page 10

    10 103618 POR T ABLE FORCED AIR HEA TERS R Air Output, Air Intake, and Lint Filters 1. Remove upper shell (see page 8). 2. Remove filter end cover screws using 5/16" nut-dri ver . 3. Remov e filter end cover . 4. Replace air output and lint filters. 5. W ash or replace air intake filter (see Pr eventative Maintenance Sc hedule, page 6). 6. ...

  • Desa BY150CEB - page 11

    11 103618 OWNER’S MANUAL Nozzle (35,000 Btu/Hr Model) 1. Remove upper shell (see page 8). 2. Remove fan (see page 13). 3. Remove fuel and air line hoses from nozzle assembly . 4. T urn nozzle assembly 1/4 turn to left and pull toward motor to remove. 5. Place plastic hex-body into vise and lightly tighten. 6 . Carefully remove nozzle from the noz ...

  • Desa BY150CEB - page 12

    12 103618 POR T ABLE FORCED AIR HEA TERS R Pump Rotor (Procedure if rotor is binding) 1. Remove upper shell (see page 8). 2. Remove filter end cover screws using 5/16" nut-dri ver . 3. Remove filter end cover and air filters. 4. Remove pump plate screws using 5/16" nut-dri ver . 5. Remove pump plate. 6. Remov e rotor, insert, and blade ...

  • Desa BY150CEB - page 13

    13 103618 OWNER’S MANUAL Fan IMPORTANT: Remove fan from motor shaft before removing motor from heater. The weight of the motor resting on the fan could damage the fan pitch. 1. Remove upper shell (see page 8). 2. Use 1/8" allen wrench to loosen set- screw which holds fan to motor shaft. 3. Slip fan of f motor shaft. 4. Clean fan using a soft ...

  • Desa BY150CEB - page 14

    14 103618 POR T ABLE FORCED AIR HEA TERS R ILLUSTRA TED PA R T S BREAKDOWN 35,000 Btu/Hr Model 18-1 18-2 18-18 18-4 18-5 18-6 18-7 18-8 18-9 18-10 18-11 18-12 18-13 18-14 18-15 18-16 18-17 18-3 Motor and Pump Assembly 1 2 3 4 5 6 7 8 9 11 22 13 13 15 16 17 18 19 20 21 22 39 43 23 24 26 27 28 29 30 31 32 35 36 37 38 22 14 10 11-1 11-2 11-3 11-4 11-5 ...

  • Desa BY150CEB - page 15

    15 103618 OWNER’S MANUAL KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 M51104-01 Handle 1 2 098511-54 Upper Shell 1 3 102432-01 Screw/Lockwasher, 1/2" 6 4 098512-43 Combustion Chamber 1 5 M51108-01 Heat Shield 1 6 M11084-29 Screw, #10-16 x 3/4" 2 7 M16660 Photocell Bracket 1 8 M10908-2 Screw, #6-32 x 3/8" 2 9 HA3019 Photocell Assembl ...

  • Desa BY150CEB - page 16

    16 103618 POR T ABLE FORCED AIR HEA TERS R 1 2 4 3 5 6 7 8 10 11 12 12 14 15 17 20 18 19 21 21 24 28 29 30 31 32 34 38 37 11 13 9 33 35 36 42 43 39 40 23 44 11 41 45 26 25 16 22 27 ILLUSTRA TED PA R T S BREAKDOWN 70,000 Btu/Hr Model 10-6 10-3 10-2 10-4 10-5 10-7 10-1 Motor and Pump Assembly Burner Head Assembly 18-1 18-2 18-18 18-4 18-5 18-6 18-7 1 ...

  • Desa BY150CEB - page 17

    17 103618 OWNER’S MANUAL P ARTS LIST 70,000 Btu/Hr Model This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 M51104-01 Handle 1 2 098511-54 ...

  • Desa BY150CEB - page 18

    18 103618 POR T ABLE FORCED AIR HEA TERS R ILLUSTRA TED PA R T S BREAKDOWN 100,000 Btu/Hr Model 8-1 8-2 8-4 8-3 8-5 8-7 8-6 1 2 3 4 5 7 8 9 10 11 12 13 14 15 17 20 25 26 9 30 31 33 34 35 36 37 38 39 40 41 6 42 9 21 22 23 24 43 44 27 28 16 19 18 47 46 45 29 32 Burner Head Assembly Motor and Pump Assembly 13-1 13-2 13-3 13-4 13-5 13-6 13-7 13-8 13-13 ...

  • Desa BY150CEB - page 19

    19 103618 OWNER’S MANUAL KEY PART PART NO. NUMBER DESCRIPTION QTY. 1 098511-138 Upper Shell 1 2 102432-01 Screw/Lockwasher, 1/2" 8 3 098512-31 Combustion Chamber 1 4 M16660 Photocell Bracket 1 5 HA3019 Photocell Assembly 1 6 M27417 Drain Plug 1 7 M10908-2 Screw, #6-32 x 3/8" 2 8 ** Burner Head Assembly 1 8-1 100735-15 Nozzle 1 8-2 M1065 ...

  • Desa BY150CEB - page 20

    20 103618 POR T ABLE FORCED AIR HEA TERS R ILLUSTRA TED PA R T S BREAKDOWN 150,000 Btu/Hr Model 8-1 8-2 8-4 8-3 8-5 8-7 8-6 1 2 3 4 5 7 8 9 10 11 12 13 14 15 17 20 25 26 9 30 31 33 34 35 36 37 38 39 40 41 6 42 9 21 22 23 24 45 44 27 28 16 19 18 43 48 47 46 29 32 8-8 Burner Head Assembly Motor and Pump Assembly 13-1 13-2 13-3 13-4 13-5 13-6 13-7 13- ...

  • Desa BY150CEB - page 21

    21 103618 OWNER’S MANUAL P ARTS LIST 150,000 Btu/Hr Model This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. **Not available as an assembly, order parts separately. KEY PART PART NO. ...

  • Desa BY150CEB - page 22

    22 103618 POR T ABLE FORCED AIR HEA TERS R ACCESSORIES Purchase accessories from your local dealer. HEAVY DUTY WHEELS AND HANDLE KIT - HA1202 For heavy duty applications. Makes your heater even more portable and convenient. For 35/70,000 Btu/Hr models. AIR GAUGE KIT - HA1180 For all models. Special tool to check pump pressure. STANDARD WHEELS AND H ...

  • Desa BY150CEB - page 23

    23 103618 OWNER’S MANUAL EC CONFORMITY DECLARA TION SGB YOUNGMAN Stanestreet, Slingfold, Horsham West Sussex Rh13 7RD United Kingdom (UK) Manufacturer: DESA International, Inc. 2701 Industrial Drive Bowling Green, KY 42101 U.S.A. Kerosene Portable Forced Air Heaters Model Numbers: BY35CEB, BY70CEB, BY100CEB, BY150CEB It is declared that these mod ...

  • Desa BY150CEB - page 24

    W ARRANTY AND REP AIR SERVICE CERTIFICATE OF GENERAL EQUIPMENT - LIMITED 1 YEAR WARRANTY Printed in U.S.A. EVENT IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY. Any transportation charges, costs of installation, duty, taxes or any other charges whatsoev ...

Fabricant Desa Catégorie Electric Heater

Les documents que nous recevons du fabricant de l'appareilDesa BY150CEB peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Desa
- manuels d’utilisations BY150CEB
- fiches produit Desa
- dépliants
- ou étiquettes-énergie Desa BY150CEB
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Desa BY150CEB.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Desa BY150CEB, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Desa BY150CEB. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Desa BY150CEB.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Desa BY150CEB, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Desa BY150CEB par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Desa BY150CEB.

Le manuel d’utilisation complet Desa, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Desa BY150CEB - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Desa BY150CEB, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lDesa BY150CEB qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Desa BY150CEB - qui devraient nous aider dans les premières étapes lors de l'utilisation Desa BY150CEB
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Desa BY150CEB
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Desa BY150CEB dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Desa BY150CEB?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Desa BY150CEB, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Desa BY150CEB il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)