Manuel d’utilisation Verona VEFSGE 365 ND

28 pages 3.12 mb
Télécharger

Aller à la page of 28

Summary
  • Verona VEFSGE 365 ND - page 1

    IMPORT ANT - PLEASE READ AND FOLLOW ✓ Before beginning, please r ead these instructions completely and carefully . ✓ Do not remove permanently af fixed labels, warnings, or plates from the product. This may void the warranty . ✓ Please observe all local and national codes and ordinances. ✓ Please ensure that this pr oduct is pro ...

  • Verona VEFSGE 365 ND - page 2

    2 ✓ Do not stor e or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. ✓ WHA T TO DO IF YOU SMELL GAS: • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • lmmediately call your gas supplier from a neighbor's phone. Follow ...

  • Verona VEFSGE 365 ND - page 3

    3 DA T A PLA TE CONVERSION LABEL This appliance is designed and manufactured solely for the cooking of domestic (household) food and in not suitable for any none domestic application and therefor e should not be used in a commercial envir onmement. The appliance guarantee will be void if the appliance is used within a none domestic environnement i. ...

  • Verona VEFSGE 365 ND - page 4

    4 W ARNING! THIS APPLIANCE HAS TO BE INST ALLED BY A QUALIFIED INST ALLER. Improper installation, adjustment, alteration, services, or maintenance can cause injury or pr operty damage. Consult a qualified installer , service agent, or the gas supplier . IMPORT ANT : The use of suitable protective clothing/gloves is r ecommended when handling, insta ...

  • Verona VEFSGE 365 ND - page 5

    5 GENERAL INFORMA TION 1. Installation must conform with local codes or , in the absence of local codes, with the National Fuel Gas Code , ANSI Z223.1-Latest Edition. 2. Installation in manufactured (mobile) home: installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 [formerly the Federal Sta ...

  • Verona VEFSGE 365 ND - page 6

    6 installation  PROXIMITY TO SIDE CABINETS 1. This range may be installed directly adjacent to existing 36" (914 mm) high base cabinets. Range dimensions: • width: 35” 7/8 (911 mm) • depth: 23” 31/32 (609 mm) • height (without backguard / island trim): MIN 35” 7/16 (900-mm) MAX 37” 13/32 (950 mm) • backguard (height): 8” ( ...

  • Verona VEFSGE 365 ND - page 7

    7 A B D C GAS AND ELECTRIC CONNECTION Dotted line showing the position of the range when installed * : Depending on feet regulation Area for GAS connection Area for ELECTRICAL connection Fig. 1.2  Rif. inch mm A 5” 1/8 ÷ 7” 3/32 (*) 130 ÷ 180 (*) B 23” 5/8 600 C 5” 1/8 ÷ 7” 3/32 (*) 130 ÷ 180 (*) D 12” 1/4 311 ...

  • Verona VEFSGE 365 ND - page 8

    8 (457 mm) 18" min. 30" min. (762 mm) (914 mm) 36" 0" (0 mm) 0" (0 mm) 20" min. (500 mm) 11" 13/16 min. (300 mm) 13" max. (330 mm) (457 mm) 18" min. 30" min. (762 mm) (914 mm) 36" 0" 0" (0 mm) (0 mm) 20" min. (500 mm) 11" 13/16 min. (300 mm) 13" max. (330 mm) OVEN VENT ...

  • Verona VEFSGE 365 ND - page 9

    9  Fig. 1.3c PROXIMITY TO SIDE CABINETS RANGE WITH ISLAND TRIM (457 mm) 18" min. 30" min. (762 mm) (914 mm) 36" 0" 0" (0 mm) (0 mm) 20" min. (500 mm) 13" max. (330 mm) 11" 13/16 min. (300 mm) 12" min. (305 mm) (457 mm) 18" min. 30" min. (762 mm) (914 mm) 36" 0" (0 mm) 0" (0 mm ...

  • Verona VEFSGE 365 ND - page 10

    10 10  Fig. 1.4 FITTING THE ADJUST ABLE FEET The adjustable feet must be fitted to the base of the cooker before use. Rest the rear of the cooker on a piece of the polystyr ene packaging exposing the base for the fitting of the feet. A TTENTION: Most important! Pay special attention not to damage the range dur - ing this operation. Fit the 4 leg ...

  • Verona VEFSGE 365 ND - page 11

    11 11  ASSEMBLING THE BACKGUARD OR THE ISLAND TRIM It is mandatory to install the backguard or the island trim • Assemble the backguard or the island trim as shown in figure 1.8 or 1.9 and fix it by scr ew- ing the 5 screws “ A ” (which ar e already fixed on the back of the cooktop). • Do not remove the 3 spacers " B " already ...

  • Verona VEFSGE 365 ND - page 12

    12 12 ANTI-TIP ST ABILITY DEVICE INST ALLA TION INSTRUCTIONS 1. The anti-tip bracket has to be attached as shown on figure below , it has to be fixed on the rear wall by no. 2 (two) suitable scr ews (supplied with the anti-tip kit). 2. After fixing the anti-tip bracket, slide range into place. Be sure the anti-tip bracket is fully inserted in the s ...

  • Verona VEFSGE 365 ND - page 13

    13 13 Gas supply line Shutoff valve “open” position To range Fig. 2.1 All gas connections must be made according to national and local codes. This gas supply (service) line must be the same size or greater than the inlet line of the appliance. Sealant on all pipe joints must be resistant to te action of LP/Pr opane gas. The range is equipped fo ...

  • Verona VEFSGE 365 ND - page 14

    14 14  PRESSURE REGULA TOR INST ALLA TION LOCK Arrow 1 2 3 A STEP 2 Assemble the “A” bracket to the extension pipe. Fig. 2.2a Fig. 2.2b STEP 1 Mount the 1/2” NPT (conical) male connector to the pressur e regulator and tighten by using a wrench. Do not over tighten the connector . Over tightening may crack regulator . ...

  • Verona VEFSGE 365 ND - page 15

    15 15 STEP 3 Assemble the 1/2” NPT connector + pressur e regulator gr oup to the extension pipe interposing the gasket supplied. The regulator cover must be or diented toward the fr ont side of the range. IMPORT ANT : use two spanners to tighten the connection. Regulator cover Fig. 2.2c  B B STEP 4 Insert the extension pipe + pressur e regulat ...

  • Verona VEFSGE 365 ND - page 16

    16 C STEP 6 Fix the “C” bracket on the back of the range by the 2 (two) screws supplied with the kit for gas connection. The regulator cover must be or diented toward the front side of the range.  Fig. 2.2f STEP 5 Assemble the extension pipe + pressur e regulator group to the range manifold interposing the gasket supplied. The regulator cove ...

  • Verona VEFSGE 365 ND - page 17

    17 Connector Pressur e regulator 1/2” G cylindrical (ISO 228-1) female 1/2” NPT (conical) male 1/2” NPT female 1/2” NPT female 1/2” G cylindrical (ISO 228-1) male Extension pipe male pipe fitting Gasket Range manifold Manifold male pipe fitting 1/2” G cylindrical (ISO 228-1) male Extension pipe female pipe fitting 1/2” G cylindrical ( ...

  • Verona VEFSGE 365 ND - page 18

    18  Fig. 2.4 TEST POINT ADAPTER The T est Point adapter is available from the After -Sales Service. c) Any conversion requir ed must be performed by your dealer or a qualified licensed plumber or gas service company . Please provide the service person with this manual before work is started on the range. (Gas conversions ar e the responsibility ...

  • Verona VEFSGE 365 ND - page 19

    19 1 2 NA TURAL GAS REGULA TION LP/PROP ANE REGULA TION A component Fig. 2.5 REGULA TOR COVER Pressur e regulator CONVERSION TO LP/PROP ANE GAS Every range is provided with a set of injectors for the various types of gas. Select the injectors to be replaced accor ding to the “INJECTORS T ABLE”. The nozzle diameters, expressed in hundr edths of ...

  • Verona VEFSGE 365 ND - page 20

    20  OPERA TIONS TO BE PERFORMED WHEN SUBSTITUTING THE INJECTORS ✓ Remove the gratings and the bur ner covers; ✓ Using a wrench substitute the nozzle injectors “ J ” (figs. 2.6a - 2.6b - 2.6c) with those most suitable for the kind of gas for which it is to be used. The burner are conceived in such a way so as not to requir e the regulatio ...

  • Verona VEFSGE 365 ND - page 21

    21 SETTING THE BURNER MINIMUM When switching from one type of gas to another , the minimum flow rate must also be correct: the flame should not go out even when passing suddenly fr om maximum to minimum flame. T o regulate the flame follow the instructions below: Semirapid and triple ring burners – Light the burner – Set the gas valve to positi ...

  • Verona VEFSGE 365 ND - page 22

    22 electrical connection  ELECTRICAL REQUIREMENTS • This appliance must be properly installed and grounded by a qualified technician in accordance with the National Electrical Code ANSI/NFP A No.70 (latest edition) and local electrical code requir ements. IN CANADA: Electrical installation must be in accordance with the curr ent CSA C22.1 Cana ...

  • Verona VEFSGE 365 ND - page 23

    23  T erminal Block Access Plate Screws Fig. 3.1 Power Co rd Bracket Hole D 1" 9/64 (29 mm) Power Wi re s Power Co rd Tighten the Power Co rd by using a suitable Strain Relief T erminal Block Ground strap Neutral Wi re Power Wi re s Power Co rd Tighten the Power Co rd by using a suitable Strain Relief T erminal Block Neutral Wi re Grounding ...

  • Verona VEFSGE 365 ND - page 24

    24 3-Wir e Conduit Installation (See Figures 3.1, 3.5 and 3.6) 1. Remove the T erminal Block Access Plate on the back of the range by unscrewing the 6 fixing Scr ews (fig. 3.1). 2. Feed 1/2” (1.3 cm) trade size Conduit through the hole in the Conduit Bracket and secure to the Conduit Bracket with a Conduit Clamp . 3. Remove the 3 wire terminal nu ...

  • Verona VEFSGE 365 ND - page 25

    25  WIRING DIAGRAM A B L1 CF L2 N OF ST GE BE TE P7 TPL OT LF CE P1 P6 P5 P4 P3 P-E61(1) P8(1) E61(2) IC P-PR ST -CF AS 2 1 PR P-PR ISG P-E61(1) EARTH L1 - L2 = 240V L1 - N = 120V L2 - N = 120V P8(2) A B E61(1) OF LF OT P-E61(2) P2 P1 P2 P-E61(2) ST P7 TPL P6 P5 P4 P3 GE BE TE CE Cod.0422408 ELECTRIC DIAGRAM KEY PR Electronic pr ogrammer E61(1) ...

  • Verona VEFSGE 365 ND - page 26

    26 ...

  • Verona VEFSGE 365 ND - page 27

    27 ...

  • Verona VEFSGE 365 ND - page 28

    Cod. 1104641 - ß1 The manufacturer cannot be held r e spon sible for possible inaccuracies due to printing or transcription errors in the present booklet. The manufacturer r e serves the right to make all modifications to its products deemed necessary for manufactur e or commercial r easons at any moment and without prior notice, without jeopardis ...

Fabricant Verona Catégorie Double Oven

Les documents que nous recevons du fabricant de l'appareilVerona VEFSGE 365 ND peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Verona
- manuels d’utilisations VEFSGE 365 ND
- fiches produit Verona
- dépliants
- ou étiquettes-énergie Verona VEFSGE 365 ND
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Verona VEFSGE 365 ND.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Verona VEFSGE 365 ND, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Verona VEFSGE 365 ND. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Verona VEFSGE 365 ND.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Verona VEFSGE 365 ND, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Verona VEFSGE 365 ND par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Verona VEFSGE 365 ND.

Le manuel d’utilisation complet Verona, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Verona VEFSGE 365 ND - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Verona VEFSGE 365 ND, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lVerona VEFSGE 365 ND qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Verona VEFSGE 365 ND - qui devraient nous aider dans les premières étapes lors de l'utilisation Verona VEFSGE 365 ND
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Verona VEFSGE 365 ND
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Verona VEFSGE 365 ND dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Verona VEFSGE 365 ND?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Verona VEFSGE 365 ND, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Verona VEFSGE 365 ND il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)