    Okeanito C O K -E36SX C O K-E42SX C O K -E48SX U s e , C a r e , a n d I n s t a lla t ion G u id e MAY07.0101 ww w .zephyronline.com Model number: Serial number: Date of Purchase: Sales Dealer: © Zep hyr Corpo ration. ...

  • Zephyr COK-E36SX - page 2

    www .zephyronline.com ...

  • Zephyr COK-E36SX - page 3

    Ta b l e o f C o n t e n t s 1 SAFET Y NOTICE .............................................. LIST OF MA TERIALS ....................................... INST ALLA TION Ducting Calculation Sheet ............................... Mounting Height and Clearance ..................... Ducting ................................................................. ...

  • Zephyr COK-E36SX - page 4

    www .zephyronline.com Im p or tan t s afety N o t i c e 2 TO R E D U C E T H E R I S K O F F I R E O R E L E C T R IC SH OC K, D O N O T USE T H IS FAN W ITH ANY S O L ID- S T A TE SP E E D CONTRO L DE V I C E . TO R E DU C E T H E R IS K O F F I R E, E L E C T R I C SH O C K, O R INJ U R Y T O P E R S ON S, O B S E RVE T H E FO L LO W I N G: a. Us ...

  • Zephyr COK-E36SX - page 5

    Li s t of M a t e r ia l s 3 MODEL: COK-ExxS 1 - Hood 1 - Bae Filter (2 on 48” model) 2 - 50W 120V Halogen Light Bulbs G U-10 2 - 40W 120V Appliance Bulbs 1 - Utensil Rail 2 - T elescopic Duct Covers 1 - Ceiling Mounting Bracket (pre attac hed to duct cover) 1 - W all Mounting Bracket 1-H A R D W A R EP A C K E T 7 - 2” W ood Screws 7 - Anch ...

  • Zephyr COK-E36SX - page 6

    www .zephyronline.com 4 I ns t a lla t io n - Duct wo rk C a lcula t io n S he e t Duct pieces To t a l Equivalent number length x used = 31 / 4 ”x1 0 ” Rect., straight 1 F t. x ( ) = Ft. 7” Round, straight 1 Ft. x ( ) = Ft. 31 / 4 ”x1 0 ” Rect. 90 0 elbow 15 Ft. x ( ) = Ft. 31 / 4 ”x1 0 ” Rect. 45 0 elb ow 9 Ft. x ( ) = Ft. 31 / 4 ? ...

  • Zephyr COK-E36SX - page 7

    5 I ns t a l l a t i o n - M o unt i ng H e i ght & C l e a ra nc e DUC T I N G 36" M in 96"-Max 124 ” M in 28"-Max 36" Min 32"-Max 52" 14 1/2" Minimum mount height between range top to hood bot- tom should be no less than 28". Maximum mount height should be no higher than 36". It is important to i ...

  • Zephyr COK-E36SX - page 8

    Installation - Ducting www .zephyronline.com side wall cap with gravity damper Soffit or crawl space Roof Pitch w/ Flashing & Cap 6 Soffit or crawl space External Blower External Blower W ARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics, or garages. All exhaust must be ducted t ...

  • Zephyr COK-E36SX - page 9

    7 I n s t a lla tion - Sp ec ific at ion s R I H P E Z Y B N G I S E D G N E H C O G O L 19 3 / 4” 19 3/4” 10” 36” , 42” , 48 ” 22 5 / 8” 11 7 / 8” 95 ° 16 5/8” 13 3 / 8” 14 1 / 2” 15” 5" - 3 6 " 8" - 42" 31 / 2 " - 4 8 " 6" 9 3/16” ” 6 1 / 5 O 8 5/16” ” 8 / 1 4 R ” 2 3 / 1 1 4 R ...

  • Zephyr COK-E36SX - page 10

    www .zephyronline.com I ns t a lla t io n - In t e r n a l B l ow e r 8 The internal blower kit consists of the blower and capacitor box with wiring. 1. Position blower as shown. 2. Att ach blower to ange as shown using the provided 1/2” 5x15mm screws with washers. 3. P osition capacitor bo x as shown. 4. Secure capacitor bo x to hood using th ...

  • Zephyr COK-E36SX - page 11

    I n s t a lla tion - I n te r n al B lower 9 5. Remove existing grounding screw and att ach grounding wire from capacitor bo x. 6. Re-attach grounding screw to nish installation of capacitor box. Refer to Fig-A on previous page. 7 . Attach short capacitor connector to blower connector. 8. Att ach long capacitor connector to control board connect ...

  • Zephyr COK-E36SX - page 12

    www .zephyronline.com 10 I ns t a lla t io n - P re p a ring E xt e rn a l B lo we r The external blower kit consists of an 8” collar , and external blower wiring box. T he external blower is purchased separately . A T TE NTI O N The following are intructions on preparing your hood for installation with e xternal blower model CB E-1000. F or inst ...

  • Zephyr COK-E36SX - page 13

    11 6. Position cover onto external blower wiring box. 7 . Secure cover to box with provided screw . 8. Attach connector from external blower wiring bo x to control board box connector inside hood. 9. Attach grounding wire from external blower wiring bo x to grounding screw of the junction bo x. Refer on Fig-A in diagram below . 10. Final view of ex ...

  • Zephyr COK-E36SX - page 14

    A B min 28” max 36” C/L C/L 14 1/2” Duct Cover Ceiling Bracket 7 1/2” Attach screws to ceiling bracket C/L C 21” Duct Cover Ceiling Bracket www .zephyronline.com 1. Measure from cooking surface to hood bottom, level and mark line A. 2. Plum and mark center line. 3. Mark mounting height, line B (14 1/2” from line A). This is the top of t ...

  • Zephyr COK-E36SX - page 15

    13 In s t a l l a t i on - Mo u n t i n g H o o d gap between bracket and wall To p Bottom 1. Place wall brac ket on line C. P osition t o p of wall brac ket so it is even with the 21” mounting spread. Make sure bracket is atta c hed to wall as shown in the diagram. T he top of the wall bra c ket should have a gap between it and the wall. T he bo ...

  • Zephyr COK-E36SX - page 16

    www .zephyronline.com 14 I ns t a lla t io n - A t t a c hing U t e ns il R a il 1. Attac h utensil rail to hood canopy . A small hole has been pre-drilled into the canopy to provide a starting point to attach the rst utensil rail post. A fter the rst post is lined up with the hole, gently slide the rest of the rail onto the canopy . (note: b ...

  • Zephyr COK-E36SX - page 17

    15 2 3 4 6 1 5 The standard Baffle Filters are required to be cleaned frequently and as recommended in order to maintain blower efficiency . If improperly maintained, residue from cooking will sift through filters and cause damage to hood blowers and other sensitive components; and possibly clog duct work and create a fire hazard. Blower On/Off Dis ...

  • Zephyr COK-E36SX - page 18

    16 Filter Clean Reminder (Standard Bae Filters tted): A set of bae lters are tted by the factory . These Bae Filters are intended to lter out residue from cooking. T hey need not be replaced on a regular basis but are required to be kept clean. The Filter Clean Reminder function in the microprocessor will automatically indicate ...

  • Zephyr COK-E36SX - page 19

    17 M a i n t e n a n c e - C l e a n i n g S urface M aintenance : C l ean p eriodicall y w i t hh ot s oap y wate r a n d c l ean cotto n c l ot h . Do n ot use co rr os iv e o r ab r as iv e deter g en t , o r stee l woo l /scourin g p a ds whi c i i h will s cra t c h an d d amag e surface . F or h ea vi er so il use liquid de g rease r . A fte ...

  • Zephyr COK-E36SX - page 20

    18 Replacing Light Bulbs: CA UTION: Light bulbs become extremely hot when turned on. DO NO T tou c h bulbs until swit c hed o and cooled. T ouc hing hot bulbs may cause serious burns. Make sure all power is turned o and bulbs are not hot. Remove bulb by pressing both ends of the metal retaining clip togethe r , the light so c ket will now pro ...

  • Zephyr COK-E36SX - page 21

    19 T ro uble S ho o t ing After installation, the unit doesn’t work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the lights are not. The hood is not venting out properly . Filter is vibrating. After hood has been installed for a period of time, it stopped working. 1. The power source is not turned ON. 2 ...

  • Zephyr COK-E36SX - page 22

    20 www .zephyronline.com Part Desc r iption P art# Halogen Bulb G U-10, 120V, 50W Z0B-0020 Incadescent Bulb T29 127V 40 W Z0B-0003 Internal Blower, 600 cfm CBI-600 External Blower, 1000 cfm CBE-1000 Duct Cover Extension Kit Z1C-00OK Accessory Desc r iption P art# List of Parts and Accessories ...

  • Zephyr COK-E36SX - page 23

    www.zephyronline.com Warranty One Y ear Service Repair W arranty: F or one year from date of original purchase, we will provide free of charge, service lab or to repair any failed parts or components due to manufacturing defects. T wo Y ears Parts W arr anty: F or two years from date of original purchase, we will provide free of charge, nonconsumab ...

Fabricant Zephyr Catégorie Ventilation Hood

Les documents que nous recevons du fabricant de l'appareilZephyr COK-E36SX peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Zephyr
- manuels d’utilisations COK-E36SX
- fiches produit Zephyr
- dépliants
- ou étiquettes-énergie Zephyr COK-E36SX
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Zephyr COK-E36SX.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Zephyr COK-E36SX, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Zephyr COK-E36SX. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Zephyr COK-E36SX.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Zephyr COK-E36SX, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Zephyr COK-E36SX par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Zephyr COK-E36SX.

Le manuel d’utilisation complet Zephyr, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Zephyr COK-E36SX - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Zephyr COK-E36SX, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lZephyr COK-E36SX qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Zephyr COK-E36SX - qui devraient nous aider dans les premières étapes lors de l'utilisation Zephyr COK-E36SX
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Zephyr COK-E36SX
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Zephyr COK-E36SX dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Zephyr COK-E36SX?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Zephyr COK-E36SX, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Zephyr COK-E36SX il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)